Neosys Product catalogue

Similar documents
SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Water systems. Providing indoor climate comfort

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

APPLICATION GUIDE NEOSYS. AIR COOLED CHILLER & HEAT PUMP kw NEOSYS-AGU-1602-E.

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AQUASNAP JUNIOR 30RHV

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

PRODUCT GUIDE

Modular Air-cooled Chillers

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Advance Split

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

KELVIN Clim F497. Kelvin air conditioning

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Aquaflair TRAC-TRAF-TRAH

Galletti Water chillers and heat pumps catalogue

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

HYDRONIC RESIDENTIAL

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

PYXIS U PYXIS U. rcgroupairconditioning

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Air cooled industrial chillers

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

Ultimate energy saving technology

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

pyxis u pyxis ua NEW rcgroupairconditioning

LZT High efficiency air to water heat pumps with E.V.I. compressors

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

LZA High efficiency air to water heat pumps with HP compressor

50A KP 70A KP 90A KP 120A KP 150A KP 210A

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

ELFOEnergy Extended Inverter

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

30RH B Nominal cooling capacity kw Nominal heating capacity kw

.2 Section Waste Management and Disposal.

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Blue Box Epsilon Echos +

Do you want a versatile solution

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Prices and technical information for Applied Systems. Pricelist Applied Systems

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

30RB A /30RQ


Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Installation Operation Maintenance

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Air-to-water scroll chillers

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

Water-cooled chillers with High Speed Centrifugal Compressors

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Be sustainable while protecting your business

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

Transcription:

00/0 Neosys Product catalogue Providing indoor climate comfort

NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled and hot water for all applications with fan coils, chilled beams, air handling units, floor heating or chilled ceiling use in office buildings, hotels, administrations,... Sustainable performance Extended qualification tests (vibration tests, run tests, field tests) to ensure superior reliability. High efficiency aluminium micro channel heat exchanger (MCHX) with improved corrosion resistance for moderate marine or urban applications (Cooling only version). Specific MCHX coil design with high mechanical fin resistance that offers easy cleaning with high pressure air or water washers for extended life cycle. Compressor and hydraulic enclosure, V-coil design to protect the unit against climatic aggressions (e.g. UV light, hail). Exclusive Compliant Scroll compressor design with both axial and radial compliance to increase compressor operation tolerance of liquid refrigerant, substantially improving durability and reliability. Exclusive fan design with hybrid ceramic bearings to maximise the service-life of motors and to reduce noise level. Quiet performance Unique design with compressors, pump(s) and fan acoustic enclosure to reduce radiated noise emissions. Variable speed driven fans using external rotor technology associated with high performance aluminium fan blades of the latest generation. Elimination of intrusive fan start/stop noise that is irritating to the human ear. Active Acoustic Attenuation System (A ) to meet changing building load requirements while automatically adjusting the air flow to meet night and day sound level constraints (Time schedule with time zones per day). Start-up and service performance Complete hydraulic module with single or twin, low or high pressure pump (options) that includes all necessary equipment for quick connection: pump(s), regulating valve, expansion vessel with pressure gauge, pressure tapping points, water filter, air vent, pressure relief valve and victaulic connections. 00V, 0 Hz, phases power supply (without neutral) with a single point of power connection. Main on/off switch included as standard. Air spring powered Butterfly electrical panel with top opening provding protection to service engineers against rain or snow during coissioning and maintenance operations. Energy performance High Seasonal Energy Efficiency Ratio in cooling and heating mode (ESEER above ; EER up to,; COP up to,) for improved energy consumption all around the year Aluminium micro channel heat exchanger offering outstanding system efficiency (Cooling only version). RA refrigerant for optimized system performance. Energy savings due to lower system minimum water content buffer tank elimination reducing the time to reach setpoint. Architectural integration State of the art design with hidden compressors, fans and pump for perfect architectural integration. Flat top, aesthetic grilles, very low unit height (< m) for discrete installation on a roof reducing the requirement of costly cladding solutions around the unit. * Quality makes the difference : year warranty on parts. This warranty only applies on compressors, fans, exchanger coils. Subject to LENNOX warranty policy and to maintenance contract by an accredited LENNOX company. General Product Catalogue 0-00 Non contractual photos

General data NEOSYS NAC 00 0 0 00 0 0 0 0 Cooling mode Cooling capacity () kw 0 0 0 EER (),,,,,,,, ESEER (),,,,,0,,, Electrical data Voltage Refrigeration circuit V/Ph/Hz 00//0 Number of circuit Compressor Evaporator Type AISI stainless steel plate brazed with copper heat exchanger Capacity steps % Condenser Type Microchannel Aluminium Tube & Fins - Air cooled Pressure drop Pressure drop () kpa,,,,,,,, Hydraulic connections Type Victaulic Diameter In/Out Inches " " Acoustic Global sound power level () db(a) 0 Operating limits Min. outlet water temperature Max. Intlet water temperature Min. difference water inlet/outlet Max. difference water inlet/outlet Min. outside air temperature Max. outside air temperature 0 NEOSYS NAH 00 0 0 00 Cooling mode Cooling capacity () kw EER (),,,, ESEER (),00,,, Heating mode Heating capacity () kw COP,,,0, Electrical data Voltage Refrigeration circuit V/Ph/Hz 00//0 Number of circuit Compressor Evaporator Type AISI stainless steel plate brazed with copper heat exchanger Capacity steps % Pressure drop Pressure drop () kpa,,,, Hydraulic connections Type Victaulic Diameter In/Out Inches " Acoustic Global sound power level () db(a) Operating limits Min. Outlet water temp Cooling Max. inlet water temperature Min. outside air temp Cooling Max. outside air temp Cooling Max. Outlet water temp Heating Max. Outdoor air Temp Heating 0 0 - () All data are at Eurovent condition. () ESEER according to EN Eurovent calcultaion method General Product Catalogue 0-00 Non contractual photos

NEOSYS Integrated hydraulic module 0 0 0 Water filter (supplied loose) 0 0 0 0 Air purge Pressure tap 0 0 Pump 0 0 0 0 0 0 Safety valve with manometer Espansion vessel Electronic flow switch 0 Plate heat exchanger 0 0 0 Setting valve Pressure tap and drain valve Return temperature sensor Supply temperature sensor Pump pressure curves Single / Double pump - Low pressure 0 0 kpa 00 0 0 0 0 NAC/NAH 0/0/0 NAC/NAH 00/0 NAC/NAH 0 0 0 NAC/NAH 0 0 m /h 0 0 0 0 0 0 0 0 0 0 NAC/NAH 00 Single / Double pump - High pressure 0 kpa 0 00 0 0 0 0 00 0 0 0 NAC/NAH 0/0 NAC/NAH 00/0/0 NAC/NAH 0 0 0 0 0 m /h 0 0 0 0 0 0 0 0 0 0 0 NAC/NAH 0 NAC/NAH 00 General Product Catalogue 0-00 Non contractual photos

C Physical data A B NEOSYS NAC 00 0 0 00 0 0 0 0 A 0 0 0 0 0 0 0 0 B C kg 0 0 00 Weight without water NAH 00 0 0 00 0 0 0 0 B C NEOSYS A Weight without water kg Please consult us Options Rear coil guard Heavy anti-corrosion coil treatment Anti-freeze protection Soft-starter Power factor correction Winter cooling operation down to - Brine operation down to - Hydraulic module with low-pressure single pump Hydraulic module with low-pressure twin pump Hydraulic module with high-pressure single pump Hydraulic module with high-pressure twin pump Water filter (supplied loose) Victaulic connection sleeve (supplied loose) DC0 remote comfort display (supplied loose) DS0 service display (supplied loose) Modbus counication interface LonWorks counication interface Bacnet counication interface Adalink supervision (available during 00) BE 0 extension board for additional I/O Anti-vibration mounts General Product Catalogue 0-00 Non contractual photos ADALINK supervision

www.lennoxeurope.com Due to Lennox s ongoing coitment to quality, the Specifications, Ratings and Dimensions are subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency PCA GL-00-E