MUS INSTRUCTION FOR USE NFPA NFPA LADDER STRAP NFPA ESCAPE ANCHOR

Similar documents
MaxLite LED Vapor Tight Linear Fixture

User s Manual and Operating Instructions

INSTALLATION & OPERATING INSTRUCTIONS

OPERATION, SERVICE & PARTS MANUAL

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

PROFESSIONAL CURLING IRON with adjustable temperature settings and Auto Shut Off after 60 minutes

OPERATION, SERVICE & PARTS MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Owner s Manual for the Cordless Backpack

HD-26, HD-36, HD-48 Heated Displays

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

Compact Equipment Warranty Policy

SSS BPV- 40 Backpack Vacuum

THE BOARD 100IB / 200IB HOME IRONING BOARD INSTRUCTION MANUAL

User's Manual. and Warranty Information. ThyssenKrupp. ThyssenKrupp Access

6 Sheet Strip-Cut Shredder for Home/Office

Humidity Monitor model 01080

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

(The chances are you re never going to read me) Owner s Manual. Model S10E.

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

INSTALLATION MANUAL VISUAL PERFORMANCE RECTANGLE SPEAKERS. Introduction. Box Contents. Speaker Placement. Surround Speakers (5.

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

OWNER S MANUAL & WARRANTY

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

3-In-1 Heated Wrap WarmtH WHere you Need It lk rints:1/1,b _P rap eated W utput:100% _O _3-in-1 H S x4.75 H 97_IN 43 ize:5 W 73 S

36 WALL MOUNTED FIREPLACE


Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

Professional Warming Drawer and Warming Drawer Cabinet

Owner s Manual & Safety Instructions

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

OWNER'S MANUAL RSL MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local:

6-Quart Backpack Vacuum

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Installation & Operation Manual Ice Cream Freezers

Instruction Manual. Double Candy Apple Cooker

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 NEFE AM-1 ELECTRIC FIREPLACE MANTEL

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

High-Velocity Floor Fan

Hot Dog Roller Grills

Deluxe Ergo Comfort Rest

TrueClean ToteCleaner

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

Cordless CellularFabric Shade. owner's handbook

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

INSTRUCTION MANUAL HS-229G

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

MOTORCYCLE RADAR & LASER DETECTION SYSTEM TPX VISUAL ALERT MANUAL

Owner s. 18 Misting MF18W. To view

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

240 ASSEMBLY & OPERATION MANUAL

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

The Fry Guy Deep Fryer

RJ11-17-TI CORDLESS GLASS ELECTRIC KETTLE. CUSTOMER SERVICE:

Owner s Manual. PIR-1 IR Learner

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Specifications. Dimensions 32" x 10" x 15" Cage Wire Thickness 3 / 16 " Page 2 For technical questions, please call

Instruction Manual Refrigerated Counter Top Displays

Instruction Manual. Carmel Apple-Dip Warmer

Mini rad-d User's Manual - February 22, 2010

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

MODEL 891 FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: SHIPPING DIMENSIONS: - 19"W 19"D 28"H SHIPPING WEIGHT: - 46 LBS.

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

MaxLite LED High Bay Fixtures

Model NT20e Installation Guide

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

Thermometer with Probe model 00891A

Here is what comes in your box:

AIRRAM Vacuum USER GUIDE 1984/2144 SERIES

VX SERIES Wireless Thermostat with Occupancy Sensor

Patent Pending invent for New Construction

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Auto/Air Power Adapter for Dell Quick Installation Guide

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Remote Vehicle Control System

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Instruction Manual. Cheese Warmer with Pump

LETTER FROM THE FOUNDERS

GETZ MANUFACTURING PART # CYLINDER DRYER

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

TrueClean ToteCleaner

Raven Backpack Vacuum

IMPORTANT SAFETY INFORMATION:

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

Humidistat-Thermostat

OmniDry 2.9 Amp Centrifugal Air Mover

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

Transcription:

INSTRUCTION FOR USE MUS NFPA LADDER STRAP NFPA ESCAPE ANCHOR UL CERTIFIED TO NFPA 1983-2012 FLAME RESISTANCE OPTION DESIGN FEATURES NFPA Ladder Strap NFPA Escape Anchor Fire Innovations 830 Petaluma Blvd N Petaluma, California 94952 United States www.fireinnovations.com Designed to fit most firefighters, quickly adjustable. This strap can be used as a onelegged harness when attached to any of ire Innovations belts.

WARNING Activities involving the use of this equipment are inherently dangerous. You are responsible for your own actions and decisions. Before using this equipment, you must: Read and understand all instructions for use. Get specific training in its proper use. Become acquainted with its capabilities and limitations. Understand and accept the risks involved. Failure to follow these instructions could result in serious injury or death. USER INFORMATION User information shall be provided to the user of the product. NFPA Standard 1983 recommends separating the user information from the equipment and retaining it in permanent record. The standard also recommends making a copy of the User Information to keep with the equipment and that the information should be referred to before and after each use. Additional information regarding auxiliary equipment can be found in NFPA 1500, Standard of Fire Department Occupational Safety and Health Programs, and NFPA 1983, Standard on Life Safety Rope and Equipment for Emergency Services. INSPECTION Inspect the belt according to your department s policy for inspecting life safety equipment. Equipment should be inspected after each use by an inspector that meets your departments training standard for inspection of life safety equipment. Each user should be trained in equipment inspection and should do a cursory inspection before each use. Inspect the belt for frayed, cut or worn material. Buckles should look uniform with no cracks, chips or out of shape appearance. Look for excessive chaffing at the wear points; typically where the Kevlar webbing comes into contact with the metal buckles. Inspect the tool holders and ensure they are fastened or sewn securely to the belt and in the proper position. If the Harness/Belt is impact loaded, it should be inspected by a qualified inspector prior to being returned to service. In some cases, a visual inspection might not be able to determine if the equipment has been damage. Based on the history of the incident, if there is any doubt regarding the safety of the equipment, it should be removed from service and retired. REPAIR Fire Innovations requires that all repair work be done by the manufacturer. All other repair work or modifications may void the warranty and shall release Fire Innovations, LLC from all liability and responsibility as the manufacturer. MAINTENANCE Clean and dry this equipment after each use to remove any dust, debris and moisture. Do not expose the belt to flame or high temperatures. Do not store your Fire Innovations Firefighter belts in direct sunlight. SAMPLE LOG The log below suggests records that should be maintained by the purchaser or user of rescue equipment. EQUIPMENT INSPECTION & MAINTENANCE LOG Model: MUS Serial # Purchase Date: / / Date Event / Repair Inspected By Comments

CERTIFIED 1983, 2012 STANDARD LADDER STRAP ESCAPE ANCHOR PAT. #US 6,732,834 THIS BELT MEETS THE REQUIREMENTS OF NFPA 1983, STANDARD ON LIFE SAFETY ROPE AND EQUIPMENT FOR EMERGENCY SERVICES, 2012 EDITION, AND THE OPTIONAL FLAME RESISTANCE REQUIREMENTS OF NFPA 1983, TYPE LADDER STRAP, ESCAPE ANCHOR. MUS NFPA LADDER STRAP NFPA ESCAPE ANCHOR Understanding belt label details TO BE COMPLIANT WITH NFPA 1983 LADDER BELT STANDARD AND POSITION POINT THE FOLLOWING ADDITIONAL COMPONENTS MUST BE USED IN CONJUNCTION WITH THIS BELT. COMPONENT MODEL: MULTI-USE-STRAP (MUS) DIRECTIONS TO MAKE NFPA LADDER BELT: PLEASE REFER TO COMPONENT INSTRUCTIONS. 1. Fire Innovations part number. 2. The serial number is a required NFPA tracking ability. This number is unique for every belt manufactured. 3. The MUS is NFPA certified with optional carabibers or multiconfiguration straps. This section indicates which option is installed (01) Steel (02) 2 Stage Carabiner (03) 3 Stage Carabiner ( 04) Multi- Configuration Strap (05) Sewned-On strap. 4. Production date. 5. United Laboratories registration number. For the latest information about certification on Fire Innovations products, please refer to this number 3BFO when searching for UL registration. 6. Country of origin. Fire Innovations takes pride of the fact that we use only US made raw goods for our belts. Our belts are manufactured in California, United States. 3BF0 EMERGENCY SERVICES LIFE SAFETY BELT IN ACCORDANCE WITH NFPA 1983-2012 3BF0

NFPA LADDER STRAP NFPA ESCAPE ANCHOR MUS PRODUCT OVERVIEW The Multi-USE Strap / MUS is a certified NFPA 1983:2012 Fire Resistance (FR) Ladder Strap/Escape Anchor Belt. It is easy to use and makes an outstanding multi-function firefighter tool. This patented Multi-Use Strap as a NFPA ladder strap, a one leg harness, and various RIT and victim carries/drags. This strap can be neatly stowed inside an accessory pouch or a turnout pocket. HIGHLIGHTS A certified NFPA 1983:2012 Fire Resistance (FR) Ladder strap A one leg harness Used in RIT operations to drag a down firefighter NFPA Positioning Point (Safety strap) in an aerial platform/bucket NFPA Positioning Point (Safety strap) in roof ladder operations Tethering with another firefighter during search activities NFPA Escape anchor or change of direction strap (carabiner version) Place as a double leg harness VERSATILITY This strap can be neatly stowed inside an accessory pouch or a turnout pocket. Also, the end of the MUS is a NFPA Positioning Point. Additionally, the carabinered Multi-Use Strap (CMUS) is a NFPA Escape Anchor in the Basket position. Some of the patented features of the Multi-Use-Strap are the Adjustable Buckle, the Shane Ring, and a connection point ring. The use of these components allows several combinations for use in numerous applications.

NFPA LADDER STRAP The Multi-Use Strap is a NFPA Rated and certified to 1983-2012 ed (FR Option) Ladder Strap. It is also a NFPA Certified attachment and positioning point. 1 2 Climb to the desired rung of the ladder. Release the Multi-Use-Strap from the pouch. Wrap the strap around a rung located above the waist and below the shoulders. Clip the Multi-Use-Strap adjustment buckle on to the D-ring of the main belt or the O-ring of the Multi-Use- Strap. Adjust the Multi-Use-Strap to the desired tension by pulling on the tail of the Multi-Use-Strap located after the adjustment buckle. TO DISCONNECT: Loosen webbing at the adjustment buckle. Unclip from D or O-ring and remove the strap from around the rung. IMPORTANT Do not attempt to repack the Multi-Use-Strap in the pouch until you are safely on the ground. ONE-LEGGED HARNESS This patented Multi-Use Strap can be wrapped around leg for temporary storage and comfort while rappeling. IMPORTANT Activities involving the use of this equipment are inherently dangerous. You are responsible for your own actions and decisions. Before using this equipment, you must: Read and understand all instructions for use. Get specific training in its proper use. Become aquainted with its capabilitis and limitations. Undestand and accept the risks involved.

NFPA ESCAPE ANCHOR The Multi-Use Strap is a NFPA Rated and certified to 1983-2012 ed (FR Option) Escape Anchor in the Basket position. STORAGE OF THE MULTI-USE STRAP ACCESSORY POUCH The Multi-Use-Strap is lusualy stowed in an accessory pouch located over the left or right thigh. To deploy the Multi-Use-Strap, simply tear the pouch cover upwards, the strap will then drop allowing immediate usage. Shane Ring LOW-PROFILE ACCESSORY POUCH Deploy the Multi-Use-Strap by grasping the Shane Loop (2) on the Multi-Use-Strap and pull forward.

WARRANTY & RETURN POLICIES THESE ARE THE SOLE AND COMPLETE WARRANTY AND RETURN POLICIES FOR ALL PRODUCTS AND SETS FORTH THE EXCLUSIVE REMEDIES OF THE CUSTOMER. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED. IN NO EVENT SHALL FIRE INNOVATIONS BE LIABLE FOR DAMAGES IN EXCESS OF THE PRODUCT VALUE OR FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES TO PERSON OR PROPERTY ARISING OUT OF THE USE OR INABILITY TO USE OF SUCH PRODUCT; TO THE FULL EXTENT THE APPLICABLE LAW MAY DISCLAIM SUCH DAMAGES. RETURN POLICY Fire Innovations allows returns or exchanges on all non-customized merchandise. Returned merchandise must be delivered in as delivered condition without any use marks. We offer a 30 day window, following the receipt, for these returns with no restocking or handling fee. Following that 30 day window a 10% restocking and handling fee will be assessed. After 90 days, all returns will be issued a company credit for the amount of invoice minus 15% restocking and handling fee. Additionally, no returns are allowed for discontinued items over 30 days of receipt. The customer is required to obtain a RMA (Return Merchandise Authorization) prior to returning any merchandize. The customer is fully responsible for shipping costs. LIMITED WARRANTY Fire Innovations warrants all its products will be free from defects in construction and workmanship for 90 days from the date of purchase. Fire Innovations at its sole option may either repair or replace a defective product at no charge to the customer. A copy of customer purchase receipt and/or invoice may be required for warranty. CUSTOMER OBLIGATIONS It is the customer s obligation to fully understand all form, fit and function of the product(s). To obtain warranty service or return services, a customer must complete the warranty Review Request Form included with the product or available online and fax or mail it back to Fire Innovations. Once the form is reviewed, a RMA will be issued. The customer must return the product, shipping charges prepaid, along with the warranty request to the provided address. EXCLUSIONS The warranty and return policies do not cover any product which has suffered normal wear and tear, defects resulting from accidents, product misuse, product abuse, failure to follow product instructions, improper product maintenance, neglect, tampering with the product, alterations, unauthorized product repairs, fire, flood, chemicals, acts of God, and damage while in transit to Fire Innovations. Further, this warranty expressly does not cover any general or consequential damages to person or property other than the product, including but not limited to devices used in conjunction with the product. REPLACEMENT GUARANTEE PROGRAM If it is determined that the failure claimed is not covered by our warranty program, you may be eligible for our Replacement Guarantee Program. This program offers any customer that has product failure/damage within a two year period (proof of purchase maybe required) that is not covered by our warranty, a replacement product at a prorated discounted price. Replacement Program Prorated Discount Schedule 0-6 months 6 months-1 year 1 year 18 months 18 months-2 years 25% 20% 15% 10%

MUS NFPA LADDER STRAP NFPA ESCPAE ANCHOR Fire Innovations 830 Petaluma Blvd N Petaluma, California 94952 United States www.fireinnovations.com