TTB582PMP Barcode: Ref. No.: 55753

Similar documents
DIRTY WATER SUBMERSIBLE PUMP

submersible water pumps

DIRTY WATER SUBMERSIBLE PUMP KIT

2 IN 1 SUBMERSIBLE PUMP

PJ130S High Pressure Cleaner

SUBMERSIBLE WATER PUMP

CLEAN WATER SUBMERSIBLE PUMP

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

DIRTY WATER SUBMERSIBLE PUMP

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

SUBMERSIBLE DIRTY WATER PUMP

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

CLEAN WATER SUBMERSIBLE WATER PUMP

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

APW-VAP-150P High Pressure Cleaner Operator Manual

WET & DRY VACUUM 1250W 12L WARRANTY INSTRUCTION MANUAL SPECIFICATIONS VWD-1212 WHAT S IN THE BOX

Instruction Manual Refrigerator-freezer

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Installation and operating instruction. Aircirculation Heater. Phoenix 2.8

FHA 1100 A1 Domestic Water Pump

Portable Electric Patio Heater User's manual

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

Submersible Garden Pump USER'S MANUAL

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

DOMINATOR IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

OPERATION & MAINTENANCE INSTRUCTIONS

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

6000, 8000, & 15000

SUBMERSIBLE WATER PUMPS

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

CONSTANT PRESSURE PUMP

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38

Air Dehumidification System. Instruction Book CLI-DH8D

Vacuum cleaner Instruction manual

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

WET & DRY VACUUM 1500W 30L WARRANTY INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au VWD-1530 WHAT S IN THE BOX

INSTRUCTIONS AND WARRANTY

OPERATING INSTRUCTIONS

K 2 Basic. Operating Instructions. Please read the operating instructions carefully before using the unit (05/17)

NV3610N NV7210N NV9610N.

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

SHIATSU MASSAGE CUSHION

INSTRUCTIONS AND WARRANTY

VADA - Rain2Main Automatic Rainwater Controller

OPERATING INSTRUCTIONS

Lifting Station Type ABS Sanimax

1300W Pressure Washer RACHP133A

Air Purification System. Instruction Book CLI-AP10-W

V80-H Multistage Pump Instruction Manual

CONSTANT PRESSURE PUMP

High Pressure Washer 130

Air Purification System. Instruction Book CLI-AP20

WET & DRY WORKSHOP VAC

Hair dryer INSTURCTION MANUAL. Model No.: RCY-82

OPERATION AND MONTAGE MANUAL ROOF FANS

POTABLE PRESSURE PUMP

Sip Vacuum Cleaner 1400/35 Wet & Dry

OPERATING INSTRUCTIONS

200W Frostwatch Radiant Heater Operation Manual

INTRODUCTION SPECIFICATIONS. Pump Flow Curve

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

INSTRUCTION BOOKLET. Suits all KTF816 models

Hair dryer INSTURCTION MANUAL. Model No.: RCY-170

INSTALLATION INSTRUCTIONS: these are intended for the qualified technician who must carry out the installation, hook-up and testing of the appliance.

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

INSTRUCTION MANUAL MODEL: 690E

EVAPORATIVE AIR COOLER

IM-H Hand Held Vacuum Cleaner. Instruction Manual Model Ref: H14 / Cat Number: DN909

Rechargeable Trimmer. Rechargeable Trimmer Instructions

EHG2000. ORIGINAL INSTRUCTIONS Heat Gun

HEAT RECOVERY AIR HANDLING UNIT

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

Please read and keep manual to ensure safe and effective use of this Appliance HOUSEHOLD USE ONLY

2 BURNER LP GAS STOVE OPERATING INSTRUCTIONS

Radiant Heater. Instruction Manual QH-200 N13275

SAFETY AND OPERATING MANUAL

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Compact Pressure Washer 100

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

7 Fin Oil Filled Radiator

Contents. Safety instructions. Device elements. Colour coding. Hazard levels

40cm Wall Fan With Pull Cord Operation

PERFORMANCE SLIMMING BELT

General safety precautions English

electric KNIFE ZX863X

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

ORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L

English Instruction Manual. Sandwichmaker 2 in 1. KORONA electric GmbH, Sundern/Germany

OPERATION AND MONTAGE MANUAL ROOF FANS

Multifunction. Vax model number:

Electric Can Opener USER GUIDE

IM-H12A Hand Held Vacuum Cleaner. Instruction Manual Model Ref: H12 / Cat Number: DN907

Product Code: Cordless Patio Weed Sweeper INSTRUCTION MANUAL. Please retain for reference.

Hair dryer User's manual

Power Wash 2000W Car. User Guide. HPW2C-ZA hoover.za.com. Version 1.0

Transcription:

Original Instructions_DFT_TTB582PMP(XKS-751PW)_V1_131114 TTB582PMP Barcode: 01045598 Ref. No.: 55753

Submersible Pump TTB582PMP

This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the product. Cleaning and user maintenance shall not be made by children without supervision. If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a safety hazard. Pump safety warnings This product is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 ma. Prevent access of children with appropriate measures. Do not use when people are in the water. Do not operate the pump without water. Make sure that no marine animals (e.g. fish) are extracted by the product. Have in mind that pollution of the liquid could occur due to leakage of lubricants. Protect the electrical connections and cords from heat, oil, sharp edges and moisture. Protect the product from frost and running dry. Avoid circulation of aggressive fluids of abrasive materials. Do not use the power cord or the float switch cable to transport or secure the product. Fix a rope to the handle for submerging, lifting or securing Check and clean the outlet and the inlet of the pump when needed. Do not pump liquids with sand or other abrasive substances. It causes increased wear and reduces the pumps output. The product is designed for clear water with a diameter of suspended impurities not exceeded 30mm. The product should be used for pumping water temperature below 35 C, do not use the product for other liquids (hydrocarbons, oils, corrosive liquids, flammable liquids ). Never use the product in case of danger of frost. The product is not designed for continuous

use. Please rest it for 10 min after each 1 hour running. General safety warnings Familiarise yourself with the operation, adjustments and functions. Internalise and follow the safety and operation instructions in order to avoid possible risks and hazards. Contact a qualified person or your dealer if you have questions after reading the instruction manual. Store the instruction manual so that it is accessible for all users. Also relay it when giving the product to others. Do not attempt to modify the product in any way. Only use attachments and accessories recommended by the manufacturer. Use the product only in accordance with this instruction manual. Misuse and incorrect handling will lead to hazards for people and property. Do not use the product if damage is visible. Check the power cord, plug, attached hoses and casing before each use. Faulty products must be repaired or proper disposed of. Disconnect the product from the power supply immediately if the cord or the product supply immediately if the cord or the product is damaged or if a breakdown occurs. Have the product repaired only by a qualified specialist. Improper repairs can lead to electric shocks or other accidents. Pull the plug rather than the power cord to disconnect the product from the power supply. Do not let the power cord hang over edges, do not squeeze or bend it. Use extensions cords that correspond with the technical requirements of this product if using an extension cord in unavoidable. When operating products outdoors, use an extension cord suitable for outdoor use.

13500 yywxx Manufacturing date code:year of manufacturing (20yy) and week of manufacturing (Wxx) 7 8

750 W 13500 l/h max. 8 m max. 7 m approx. 5.9 kg Ø 25 mm (outter thread) for connector Ø 38 mm (outter thread) for adaptor

upper Fasten a rope (not provided) to the handle (1) and submerge the product carefully into the water reservoir (Fig.4) Lift the pump by a rope(not provided) from the water reservoir after use. WARNING: Do not lift the pump by power cord.

16 18 20 24 25 26

750 TTB582PMP 7 10 NOTE: Make sure the cable length is not less than 50mm between float switch and clip.

NOTE: This product can be used to suck up water with a lower height (90mm: depending on the pump) but must be manually operated the float.

Submersible Pump TTB582PMP The Low Voltage Directive 2006/95/EC(until 19/04/2016) and 2014/35/EU (from 20/04/2016) EN 60335-1:2012+A11:2014 The EMC Directive 2004/108/EC (until 19/04/2016) and 2014/30/EU (from 20/04/2016) Date: 08/01/2016 Submersible Pump TTB582PMP