PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

Similar documents
USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION FLANGE FINISH

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

80 Watts FLANGE FINISH

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

PROJECT INFORMATION PROJECT

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

SliverLED Round Downlight, 1 Regress SR11

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

BeveLED 2.1 PROJECT INFORMATION

PROJECT INFORMATION PROJECT DATE TYPE

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

DATE TYPE 40 DELIVERED PERFORMANCE

OPTIONAL LENS 2 FLANGE FINISH

Field changeable between Trimmed / Trimless / Millwork

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

1" Regress Trim DELIVERED PERFORMANCE - Downlight

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

SliverLED Round Adjustable, Wet Location SR21W

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

NanoLED NXT Cylinder LNRP3 Surface

Field changeable between Trimmed / Trimless / Millwork

BeveLED Cylinder LBRP6 Surface

True Zero Conceal - Z3SA-C 3 Square Adjustable

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

BeveLED Cylinder LBRP6 Pendant

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

BeveLED Mini Trimless Acoustical - B3RDP

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3SD 3 Square Downlight

BeveLED Mini - B3RA 3 Round Adjustable

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

BeveLED Mini - B3RD 3 Round Downlight

PROJECT DATE FLANGE FINISH

Micro Wall Wash Trimless - MWL

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke Square Downlight

Grüv Flare Regressed. Recessed Linear LED

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Evoke Square Downlight

Evoke Square Adjustable HP

Evoke Round Adjustable C3

Evoke 2.9" HP. 2.9" Square Downlight

Essenza. Square Downlights

Grüv Flare Regressed. Recessed Linear LED

Evoke Round Downlight

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

Essenza. Round Downlights

Evoke Square Adjustable HP

Evoke Square Adjustable C3M

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Adjustable C3

Hornet HP. Round Glass Downlight

IHOL-4DR / IRD400 4 Gravity LED Downlight

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Hornet HP. Square Glass Downlight

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Hornet HP. Semi-Recessed 4-Light Square Multiple

Velato. Recessed Slot Adjustable Multiples

Fino Healthcare. Asymmetric Wall Mount Indirect LED

ELEMENT LED Dimmer Compatibility Testing

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Classix 6" 6" Round Lens Wall Wash

Transcription:

Beve mini Trimless PROJECT INFORMATION PROJECT DOWNLIGHT 2411 Covered By US Patents 7,832,889, 8,684,570 and 9,671,091 DATE TYPE 1" REGRESS Beve mini Recessed Downlight - The Beve mini provides maximum delivered lumens and optical performance through the optimization of thermal, optical and science in the smallest possible aperture. 1" Regress DELIVERED PERFORMANCE Bevemini 14 Watts 20 Watts DOWNLIGHT 90+ 90+ 80+ HIGH 80+ HIGH Color Rendering Index CRI CRI CRI CRI Lumens per Watt 64 52 53 43 Source Lumens 1100 825 1500 1050 Delivered Lumens 900 725 1150 925 Color Consistency 2-Step MacAdam Ellipse Performance based on 3000K CCT MULTIPLIER 2700K 3000K 3500K 4000K 90+ 90+ 80+ HIGH 80+ HIGH 80+ 80+ Color Rendering Index CRI CRI CRI CRI CRI CRI Multiplier for Lumen Output 1.00 0.73 1.00.80 1.15 1.07 Bevel Finish 1 3 4" x 1 3 4" 3" x 3" HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 2411W - B1 - S - 10 - LSLD3-9014 - M2-27KS - 25 - NC1-277V - DIML2 - CB27 TRIM ORDERING INFORMATION TRIM OPTION 2411 Square Trimless Downlight 1 Regress 2411 HOUSING ORDERING INFORMATION ENGINE HOUSING CODE WATTAGE CODE COLOR REFLECTOR HOUSING TYPE LSLD3 M2 LSLD3 9014 14W, 900 lumens 9020 20W, 1150 lumens W Wet location 1 1 Wet location, use with B1 trims only. N/A with millwork BEVEL STYLE B1 1" Regress Bevel, Painted Die Cast AB1 1" Regress Bevel, Black Anodized Finish AC1 1" Regress Bevel, Clear Matte Anodized Finish M2 27KS 2700K, 80+ CRI 25 NC1 New Construction 30KS 3000K, 80+ CRI 25 beam CP Chicago Plenum 2 35KS 3500K, 80+ CRI 35 IC Insulation-Contact 35 beam 40KS 4000K, 80+ CRI Rated / Airtight 2 50 27KH 2700K, 90+ CRI FT Baby Flat 50 beam Housing 30KH 3000K, 90+ CRI New Construction 2 FTIC Baby Flat 2 Housing IC-Rated/Airtight (up to 14W maximum) FTA Baby Flat Adjustable Housing 2 2 Step MacAdam ellipse is standard for all LENS S Solite (provided standard) F Frosted S Solite (provided standard) F Frosted 2 Not available with EM. SELECT ONE VOLTAGE 120V 277V 120V 347V B1 BEVEL FINISH 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles) DIMMING OPTIONS For use with 120V or 277V DIML2 0-10V dim, 10% (provided standard) DIML4E Lutron 5 ECO, 5% 3 DIML4H Lutron H ECO, 1% Fade 3 DIML6A Eldo 0-10V, 0.1%, logarithmic / Lutron controls 3 DIML6B Eldo 0-10V, 0.1%, linear controls 3 DIML6E Eldo 0-10V, 1%, logarithmic/ Lutron controls 3 DIML6F Eldo 0-10V, 1%, linear controls 3 DIML7 Eldo DALI, 0.1% 3 For use with 120V only DIML3 Lutron A 2-wire, 1%, 120V only 3 DIML19 Phase 2-wire dimming, 1% 120V only For use with 347V only DIML15 0-10V dim, 1% 347 only 3, 4 3 N/A with FT or FTIC housings 4 N/A with FTA housing ACCESSORIES CB27 27 C-Channel Bars 6 CB52 52 C-Channel Bars 6 CM27 27 C-Channel Bars (use with FT or FTIC housing only) CM52 52 C-Channel Bars (use with FT or FTIC housing only) EML Emergency battery 5 EMLW Emergency battery, wet location 5 MLXX Millwork Adapter XX=Specify Color (Millwork not wet listed) 5 EM requires above ceiling access. For use with NC1 housing only. 6 Not available with FT or FTIC housings 2013., LLC. Revised 12/24/2018

Beve HOUSING INFORMATION mini Trimless DOWNLIGHT 2411 New Construction Housing - NC1 IC / Airtight - IC Chicago Plenum - CP 5 1 /2" 7 1 /2" 5/8" to 1 6 7 /8" 8 1 /2" 5/8-1 10 1 /8" 12" 15 1 /2" 1 1 /2" 19 1 /8" 17 5 /8" (Plan View) Baby Flat Housing - FT - Trimless 5 /8-1" Always 3 1 /2" 5 3 /4 Baby Flat Trimless IC-Rated/Airtight - FTIC (14W Maximum) 5 /8-1" Always 3 1 /2" Baby Flat Trimless Adjustable- FTA 4 1" 5 3 /4 10 7 /8 (Plan View) 14 1 /2 (Plan View) 10 7 /8 (Plan View) 14 1 /2 (Plan View) 10 14 1 /2 (Plan View) 18 3 /16 (Plan View) Baby Flat Millwork Baby Flat Housing - FT - Millwork IC-Rated/Airtight - FTIC (14W Maximum) 2 1 1 /2 3 1 /2 2" 1 1 /2 3 1 /2 Baby Flat Millwork Adjustable- FTA 4 1 1 /2 5 3 /4 5 3 /4 10 10 7 /8 (Plan View) 14 1 /2 (Plan View) 10 7 /8 (Plan View) 14 1 /2 (Plan View) 14 1 /2 (Plan View) 18 3 /16 (Plan View) 2013., LLC. Revised 12/24/2018

Beve SPECIFICATIONS mini Trimless DOWNLIGHT 2411 TRIM: 3" square aperture with a 1" regressed bevel, retained by two mounting clips. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized grey finishes. Also available in black anodized or clear matte anodized bevel. Custom colors available (provide RAL#). TRIM LENS: Trim is shipped with integral solite lens. Frosted lens available as an option. REFLECTOR: Interchangeable precision injection molded specular polycarbonate reflector optimized for 25, 35 or 50 beam distribution. FIELD REPLACEABLE LIGHT ENGINE: Available in 2 lumen packages: 14W (900 delivered lumens), 20W (1150 lm). Engine is field replaceable through the aperture without tools. COLOR: Beve mini is available in 4 color temperatures (2700K, 3000K, 3500K, 4000K). All color options are tightly binned for fixture-to-fixture color consistency within a 2-Step MacAdam Ellipse. 80+ color rendering index provided standard. 90+ CRI available for 2700K and 3000K CCTs. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum life. Ambient temperatures at fixture location should not exceed 40 C during normal operation. FIELD REPLACEABLE : 0-10V, 100%-10% solid state electronic constant current DIML2 dimmingdriver with a high power factor provided standard and sources 2mA. Specify 120V or 277V. Driver complies with IEEEC62.41 surge protection. DIMMING OPTIONS: Multiple dimming drivers available. See compatibility chart attached. Some on-time delay may be experienced depending on control system used Note: DIML6A and DIML6E logarithmic control are intended for use with Lutron control systems; DIML6B and DIML6F linear control are intended for use with non-lutron controls. DIML6 dimming drivers source 2mA. EMERGENCY: Emergency lighting battery pack with remote test switch requires above ceiling access for service. Bodine 17C provides 200mA for 90 minutes; delivers 450 lumens. EMLW wet location option is available with B1 trim only and requires remote test switch. EM option is available with NC1 housings only. HOUSING: All-Ways Square (covered by US Pat. No: US 7,832,889) housing allows alignment of square aperture (up to 20 rotation) after housing installation and prior to finish ceiling installation. (N/A with FTA housing). Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. IC-rated housings for use with 14W light engines only are rated for direct contact with insulation of R-42 or less. IC-rated housings for use with 20W light engines are rated for direct contact with insulation of R-30 or less. FT housing not for use with through-branch circuit wiring. NOTE: Millwork option requires dedicated millwork housing. It is not an accessory that can be added on to an existing trimless housing. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided standard. Nailer bars are extendible from 14 to 24 centers. If channel bars are specified for FT or FTIC housing, special reduced height channel bars (CM27 or CM52) will be provided. MAXIMUM CEILING THICKNESS: As per drawings above. Millwork option for 1 max wood. CEILING CUT OUT: Millwork: 3-5/16" x 3-5/16" FTA Trimless: 3-3/4 x 3-3/4 All other Trimless: 3-1/2 x 3-1/2 LISTINGS: Dry/Damp. Wet location option available with B1 trim only. Millwork dry/damp only. NRTL/ CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years Not for use in corrosive environment. Use of pressure washer voids warranty. For interior use only. Not for use with acoustical ceilings. Trimless for drywall installation only. Millwork option for non-spackle installations. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. 2013., LLC. Revised 12/24/2018

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D2 / DIML2 D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 0-10V D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. 2016., LLC. I2-264-2 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D3 / DIML3 D3 / DIML3 : Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF2-6ND-120-100% - 1% 1 8 1 4 Lutron Maestro Wireless 1000W dimmer MRF2-10ND-120-100% - 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD-6ND- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 13 1 6 Lutron Caseta Wireless Pro 1000W dimmer PD-10NXD- 100% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 100% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 100% - 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD-10ND- 100% - 1% 1 6 1 3 Lutron myroom DIN power module MQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-100% - 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 100% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 100% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-3100-, GRX-3500-100% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 26 1 13 Lutron GP dimming panels Various 100% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL-250-100%-1% 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE ONLY FOR SWITCHES WITH 2016., LLC. I2-264-3 Revised 03/22/2017

DIMMING WIRING SCHEMES: D4E / DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 5% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 5% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 5% 1 64 1 32 Lutron Quantum Various 100% 5% 1 64 1 32 DIMMING COMPATIBILITY D4E / DIML4E and D4H /DIML4H D4E / DIML4E : Lutron 5 Series EcoSystem Driver / Dimming Driver Wiring (Dims down to 5%) * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4H / DIML4H : Lutron H Series EcoSystem Driver with Fade to Black (dims down to 1%) D4H / DIML4H EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 1% 1 64 1 32 Lutron Quantum Various 100% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4E / DIML4E and D4H / DIML 4H EcoSystem CONTROLS E2 E1 ECOSYS BUS E2 E1 WALL CONTROL 2016., LLC. I2-264-4EH Revised 03/22/2017

DIMMING COMPATIBILITY D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% dimmer. Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-lutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron ilux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V DIMMING (NO RELAY) CLASS 2 CONTROL WIRES DIMMER: 0-10V RELAY DIMMER: 0-10V w/ POWER SWITCHING DIMMER: 0-10V w/ POWER SWITCHING DIML6A, 6B 0-10V DIMMING (NO RELAY) 2016., LLC. I2-264-6 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D7 / DIML7 and D7E D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) 2016., LLC. I2-264-7 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D15 / DIML15 D15 / DIML15 : 0-10V, 347V Dimming Driver Wiring (Dims down to 1%) 347V Only D15 / DIML15 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Output Range Per Dimmer* 347 Use source current per Acuity Synergy ISD-BC 100% - 1% fixture specification Douglas WPN-5721, WPN-5822 100% - 1% sheet to determine Hubbell Light Hawk2 LHD-IRS3-N347-xx 100% - 1% number of fixtures per Leviton Illumatech IP710-DLZ with 347V relay 100% - 1% dimmer. Max number Leviton Centura Fluorescent Control System 100% - 1% of fixtures is limited by Lutron Nova NFTV-* dimmer plus 347V relay 100% - 1% dimmer load rating. Lutron Diva DVTV-* dimmer plus 347V relay 100% - 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D15 / DIML15 0-10V DIMMING W/RELAY TO SWITCH POWER DIMMER: 0-10V NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIML2 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING NOTE: Quickship fixtures are shipped prewired for 0-10V dimming controls. If switched, nondimming operation is desired, cap off purple and gray wires separately at installation. Do NOT cap purple and gray wires together. 2016., LLC. I2-264-15 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D19 / DIML19 D19 / DIML19 : Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P 2016., LLC. I2-264-19 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D2 / DIML2 D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 0-10V D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. 2016., LLC. I2-264-2 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D19 / DIML19 D19 / DIML19 : Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P 2016., LLC. I2-264-19 Revised 03/22/2017