ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

Similar documents
WATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION

Kompressoren. Oil Water Separators OWS

Adsorption Dryers for Compressed Air

ADSORPTION DRYING: WHY?

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Adsorption Air Dryers

Adsorption Dryers. AD 7 to 1300

Compressed Air Products

Adsorption Dryers. AD 7 to 1300

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

CPP condensate separator series. High-performance products. Designed for you!

Adsorption Dryers. DB 05 to 130

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30

Series 57 WATER/OIL SEPARATORS

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Heatless Desiccant Compressed Air Dryers

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

Adsorption air dryers ADS 1 215

DGH Series Global Air Treatment

Rotary screw compressors. kw 2, ,5 bar 10 BRIO

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Filters & Centrifugal Separators

P3X Series Membrane dryers

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

Dryer Systems Heatless Regenerating Purification Packages

Atlas Copco. Condensate management. OSC & OSD Oil/water separator series

CDH Series Heatless Desiccant Dryers CFM

Downstream Equipment. Intelligent Air Technology

High Efficiency Compressed Air Dryers. Adsorption Dryers Classical System INTELLIGENT AIR TECHNOLOGY

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY


Rotary screw compressors

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

Membrane Technologies DMD Series Dryers ESM Series Dryers

Adsorption Air Dryers

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Installation & Maintenance Instructions SEPREMIUM 350. Oil /water separator 05/09

ES2000 Series. Oil / Water Separators ENGINEERING YOUR SUCCESS. mb air systems ltd

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Single Tower Heat Reactivated Desiccant Air Dryer

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

Dryer Systems. Breathing Air Units

Dryer Systems Heatless Regenerating Adsorption Dryers

Technical Specification

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Product Data Sheet Adsorption Dryer DPS (A)

CMMD Series Membrane Air Dryer

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

Modular Adsorption Dryers

A-DRY Heatless adsorption compressed air dryers

Cooling with compressed air partial flow: the Heat Regenerating Adsorption Dryer EVERDRY FRP

BULLETIN: APPL-QAF-133R1

ENGLISH. Installation & Maintenance Instructions

White paper Compressed air drying

NEVER CHANGE ORIGINAL COMPONENTS WITH ALTERNATIVES.

Combination Dryer HYBRITEC

Leading Innovation in Compressed Air Treatment CTS SERIES ELIMINATOR II OIL WATER SEPARATORS

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

PNEUDRI MiDAS - Mini Dry Air System

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

Dry compressed air finally exits via a validated GL after-filter preventing the migration of particles into the downstream compressed air network.

Rotary screw compressors

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

AIRROLLAIR COMPRESSORS

Dryer Systems Heatless Regenerating Adsorption Dryers

High quality compressed air from generation to application

Chapter 9: The basics of air preparation

OIL FREE WATER INJECTED SCREW COMPRESSOR WIS 40-75

PNEUDRI MiDAS A totally clean and dry compressed air system (CDA)

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

DESICCANT AIR DRYERS. BD + CD + CD series

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

Dryer Systems Heatless Regenerating Adsorption Dryers

PNEUDRI High Efficiency Compressed Air Dryers.

CONDENSATE MANAGEMENT

DESICCANT AIR DRYERS. BD + CD + CD series

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Membrane Dryers KMM Series

Quality air solutions. Refrigerant Dryers Adsorption Dryers Filters Oil-Water Separators Accessories

Modular Adsorption Dryers

HEATLESS DESICCANT AIR DRYERS

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Adsorptions dryers. ecodry K-MT multitronic

Dryer Systems Heat Regenerating Adsorption Dryers

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

HIGH QUALITY COMPRESSED AIR FROM GENERATION TO APPLICATION A GUIDE TO THE ISO 8573 AND ISO SERIES OF COMPRESSED AIR QUALITY STANDARDS

Operating Instruction. Condensate separator CC 35

Product Data Sheet Adsorption Dryer DPS

REFRIGERATION AIR DRYERSDW DW 2-420

Hydra-D. Ultra-high purity desiccant air dryers. Engineering GREAT Solutions

domnick hunter PNEUDRI DME012-RX - DME080-RX USER GUIDE Original Language

Compressed Air Dryers

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

F o r Te x t i l e I n d u s t r y

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Transcription:

ADSORPTION DRYERS For all applications which require perfectly dry compressed air : high quality air for laboratories, food processing, robotics, telecommunications, laser applications electronic instrumentation and control compressed air systems operated at temperatures of less than +3 C sawmills, ready-mix concrete plants, quarries, chemical and pharmaceutical industries ALC adsorption dryers provide high efficiency continuous operation. Upline and downline filtration with automatic purge are fitted as standard, enabling the dryers to provide dry, dust-free air. Advantages of "ALC" dryers : Dependable continuous operation at maximum capacity Desiccant changes colour when saturated, enabling the dew point to be monitored Low pressure drop Columns pressurised regularly and progressively, ensuring constant output pressure and long desiccant life Tough, compact epoxy-coated steel casing High quality silencers keep noise levels below 78 db(a) Upline filtration: 0.01 micron with submicron filter, downline filtration: 1 micron Simplicity and low maintenance costs. No-mess desiccant cartridges are quick to replace. ALC DOC 05E - 04.05

Adsorption dryers, heat-less regeneration 1 Submicron filter 9 5 2 Left drying vessel 3 Right drying vessel 2 3 4 Wet compressed air (in) 5 Dry compressed air (out) Shuttle valve 7 Solenoid valve 4 8 Silencer 1 7 7 9 Micron filter 8 8 The dryer comprises two desiccant bed columns. When one column is drying, the other is in the regeneration phase. Damp compressed air entering the dryer is directed through a two-way valve to the bottom of one of the columns. The drying phase works from the bottom up, then the air is directed to the second two-way valve which draws off a small amount of dehydrated air in order to eliminate, at atmospheric pressure, the humidity in the other column.* The unit is progressively and regularly depressurised through silencers located under the dryer, avoiding any atmospheric pollution and keeping the exhaust noise level low *The air used by the column in the regeneration phase accounts for approx. 15% of the flow rate entering the dryer (this regeneration flow rate must be taken into account when selecting which model of dryer to install). Article code Inlet flow rate Outlet flow rate Regeneration flow rate Registered office : Prevost SAS Parc d activités des Glaisins - B.P. 208 FR - 74942 ANNECY-LE-VIEUX CEDEX - FRANCE Tel. 00 33 (0)4 50 4 04 45 - Fax 00 33 (0)4 50 4 00 10 Dew point under pressure m 3 /h m 3 /h m 3 /h C Fem. Gas BSP bar (at 7 bar) Connection Delta P Dimensions Weight E mail : sales@prevost-ltd.com Web : www.prevost-ltd.com Electrical consumption mm W x D x H Kg W ALC 5.9 5.00 0.90-40 1/4" 0.01 137x237x53 13 47 ALC 10 9.7 8.20 1.50-40 1/4" 0.02 137x237x53 13 47 ALC 17 17.5 14.90 2.0-40 1/4" 0.08 137x237x53 17 47 ALC 22 22.4 19.00 3.40-40 1/4" 0.11 137x237x941 19 47 ALC 33 33.4 28.40 5.00-40 1/4" 0.2 137x237x941 24 47 ALC 5 5.1 47.70 8.40-40 3/4" 0.07 198x32x824 37 47 ALC 77 77.4 5.80 11.0-40 3/4" 0.11 198x32x824 43 47 ALC 121 120.9 102.80 18.10-40 3/4" 0.32 198x32x1323 4 47 ALC 183 183.1 155.0 27.50-40 1 1/4" 0.20 477x415x132 110 4 ALC 241 241.4 205.20 3.20-40 1 1/4" 0.32 477x415x132 130 4 Flow rates expressed for an inlet pressure of 7 bar and an inlet temperature of 35 C - Ambient temperature: 25 C in accordance with standard ISO 7183 The following factors assist in selecting dryers for non-standard conditions of use Coefficient for different inlet pressures in bar Pressure (bar) 4 5 7 8 9 10 11 12 13 14 15 1 Flow rate coefficient 0.47 0.5 0.88 1.00 1.08 1.14 1.20 Contact your distributor for selection Coefficient for different air inlet temperatures in C Temp. ( C) +5 +30 +35 +40 +45 +50 Flow rate coefficient 1.00 1.00 1.00 0.88 0.70 0.0 Published by Prevost - This document may not be deemed contractually binding. To provide better service for customers, Prevost reserves the right to alter product characteristics without notice.

REFRIGERATED DRYERS Safe and easy operation The air that leaves a compressor contains water in the form of droplets or vapour and which can damage machinery and pneumatic tools. This problem can be averted by installing an air dryer. An air dryer uses a heat exchanger to lower the temperature of compressed air and condense the water contained in it. The condensed water is then discharged through a built-in drain. ALF dryers: unparalleled technology Original dual-condenser refrigeration circuit no fan no fan pressure switch energy effi cient Safe and easy to use, just like a home refrigerator maintains a stable dew point temperature of 3 C under all conditions operates at ambient temperatures ranging from 3 C to +45 C with no fl ow correction factor frost-free operation insensitive to dust quiet and clean low pressure drops ALF DOC05E-02.05

«ALF» ALTITUDE air dryers Dual-condenser dryers for R134a refrigerant - 1 outer static condenser: R134a / Ambient air - 1 condenser that removes chilled condensate from compressed air leaving the evaporator at 3 C Balanced heat transfer between the evaporator and the compressed air / R134a condenser ensures a stable dew point Compressed air outlet temperature 5 C higher than inlet temperature. - Dew point indicator - Protection rating: IP44 - Electrical supply: 230 V, 50 Hz - Condensate drain: timed solenoid valve - Min. pressure: 2 bar - Service pressure: 7 bar - Max. pressure: 1 bar - 2-year warranty - standard exchange subject to diagnosis by Prevost ALF air dryers Model Flow rate Connections Dimensions Weight Noise level Consumption Nm3/h BSP Gas female mm WxDxH kg db(a) kw ALF 30 30 3/8" 320x320x382 19 45 0,17 ALF 0 0 3/4" 394x38x58 28 51 0,28 ALF 80 80 3/4" 394x38x58 30 53 0,35 ALF 100 100 3/4" 500x500x58 41 53 0,43 ALF 10 10 3/4" 49x8x951 72 0 0,5 Flow rates given with an inlet pressure of 7 bar - Compressed air inlet temperature: 35 C in accordance with ISO 7183 Correction factors based on the inlet pressure and the air inlet temperature: Pressure (bar) 2 3 4 5 7 8 9 10 11 12 13 14 15 1 ALF30 to 100 0.70 0.80 0.87 0.92 0.9 1.00 1.03 1.05 1.07 1.08 1.10 1.11 1.12 1.13 1.14 ALF 10 0.2 0.72 0.82 0.90 0.9 1.00 1.04 1.07 1.10 1.13 1.15 1.17 1.19 1.20 1.21 inlet Temp. C +25 +30 +35 +40 +45 +50 +55 ALF30 to ALF10 1.0 1.24 1.00 0.82 0.9 0.59 0.50 Parc d activités des Glaisins - B.P. 208-74942 ANNECY-LE-VIEUX CEDEX FRANCE Tél. 00 33 (0)4 50 4 04 45 - Fax 00 33 (0)4 50 4 00 10 E.mail : sales@prevost-ltd.com - Web : www.prevost-ltd.com

ADSORPTION DRYERS For all applications which require perfectly dry compressed air : high quality air for laboratories, food processing, robotics, telecommunications, laser applications electronic instrumentation and control compressed air systems operated at temperatures of less than +3 C sawmills, ready-mix concrete plants, quarries, chemical and pharmaceutical industries ALC adsorption dryers provide high efficiency continuous operation. Upline and downline filtration with automatic purge are fitted as standard, enabling the dryers to provide dry, dust-free air. Advantages of "ALC" dryers : Dependable continuous operation at maximum capacity Desiccant changes colour when saturated, enabling the dew point to be monitored Low pressure drop Columns pressurised regularly and progressively, ensuring constant output pressure and long desiccant life Tough, compact epoxy-coated steel casing High quality silencers keep noise levels below 78 db(a) Upline filtration: 0.01 micron with submicron filter, downline filtration: 1 micron Simplicity and low maintenance costs. No-mess desiccant cartridges are quick to replace. ALC DOC 05E - 04.05

Adsorption dryers, heat-less regeneration 1 Submicron filter 9 5 2 Left drying vessel 3 Right drying vessel 2 3 4 Wet compressed air (in) 5 Dry compressed air (out) Shuttle valve 7 Solenoid valve 4 8 Silencer 1 7 7 9 Micron filter 8 8 The dryer comprises two desiccant bed columns. When one column is drying, the other is in the regeneration phase. Damp compressed air entering the dryer is directed through a two-way valve to the bottom of one of the columns. The drying phase works from the bottom up, then the air is directed to the second two-way valve which draws off a small amount of dehydrated air in order to eliminate, at atmospheric pressure, the humidity in the other column.* The unit is progressively and regularly depressurised through silencers located under the dryer, avoiding any atmospheric pollution and keeping the exhaust noise level low *The air used by the column in the regeneration phase accounts for approx. 15% of the flow rate entering the dryer (this regeneration flow rate must be taken into account when selecting which model of dryer to install). Article code Inlet flow rate Outlet flow rate Regeneration flow rate Registered office : Prevost SAS Parc d activités des Glaisins - B.P. 208 FR - 74942 ANNECY-LE-VIEUX CEDEX - FRANCE Tel. 00 33 (0)4 50 4 04 45 - Fax 00 33 (0)4 50 4 00 10 Dew point under pressure m 3 /h m 3 /h m 3 /h C Fem. Gas BSP bar (at 7 bar) Connection Delta P Dimensions Weight E mail : sales@prevost-ltd.com Web : www.prevost-ltd.com Electrical consumption mm W x D x H Kg W ALC 5.9 5.00 0.90-40 1/4" 0.01 137x237x53 13 47 ALC 10 9.7 8.20 1.50-40 1/4" 0.02 137x237x53 13 47 ALC 17 17.5 14.90 2.0-40 1/4" 0.08 137x237x53 17 47 ALC 22 22.4 19.00 3.40-40 1/4" 0.11 137x237x941 19 47 ALC 33 33.4 28.40 5.00-40 1/4" 0.2 137x237x941 24 47 ALC 5 5.1 47.70 8.40-40 3/4" 0.07 198x32x824 37 47 ALC 77 77.4 5.80 11.0-40 3/4" 0.11 198x32x824 43 47 ALC 121 120.9 102.80 18.10-40 3/4" 0.32 198x32x1323 4 47 ALC 183 183.1 155.0 27.50-40 1 1/4" 0.20 477x415x132 110 4 ALC 241 241.4 205.20 3.20-40 1 1/4" 0.32 477x415x132 130 4 Flow rates expressed for an inlet pressure of 7 bar and an inlet temperature of 35 C - Ambient temperature: 25 C in accordance with standard ISO 7183 The following factors assist in selecting dryers for non-standard conditions of use Coefficient for different inlet pressures in bar Pressure (bar) 4 5 7 8 9 10 11 12 13 14 15 1 Flow rate coefficient 0.47 0.5 0.88 1.00 1.08 1.14 1.20 Contact your distributor for selection Coefficient for different air inlet temperatures in C Temp. ( C) +5 +30 +35 +40 +45 +50 Flow rate coefficient 1.00 1.00 1.00 0.88 0.70 0.0 Published by Prevost - This document may not be deemed contractually binding. To provide better service for customers, Prevost reserves the right to alter product characteristics without notice.

"SPH" CONDENSATE TREATMENT UNITS All condensates from lubricated compressors have high hydrocarbon content and are harmful for the environment. It is illegal to discharge these condensates untreated. Treatment of effluents from lubricated compressors Role of treatment units: receive condensates from pollutant-generating facilities separate oils from water collect concentrated pollutants discharge treated water directly to the sewer system. Operation of SPH units: Pollutants are separated in two phases, passing in turn through: a polypropylene cartridge to absorb oil an activated carbon cartridge to absorb residual oil (oil vapour) Degree of separation: < 10 ppm, i.e. 10 mg/l accepted Advantages of SPH units: No separation chamber: no bacterial pollution stemming from stagnant water Separate all effluents, including stable emulsified oils* Collect condensates from all types of purge (manual, automatic, electronic) Separate mineral and synthetic oils** Filter element saturation test kit Overload indicator (on SPH 2100 models) * A special cartridge is required for polyglycol oils; consult us for details ** except SPH 110 which separates mineral oils only SPH DOC 05E - 04.05

1 5 2 7 3 4 SPH 480 Spécifications : SPH 110 SPH 480 SPH 2100 SPH EXT with SPH EXT 2100 extension Degree of separation < 20 ppm < 10 ppm < 10 ppm < 10 ppm Treatment capacity 0 to 108 m 3 /h 0 to 480 m 3 /H 0 to 2,100 m 3 /H 2,100 to 4,200 m 3 /H Decompression element 2 yes yes yes - Retention capacity of white polypropylene cartridge 3 litres 18 litres - Quantity of activated carbon 2 kg 4,50 kg 18 kg - Polypropylene cartridge saturation indicator 5 no yes yesi - Activated carbon cartridge 4 1 1 1 1 Condensate inlet 1 Ø 13, 3/8", 1/4" 2 x 1/2" 4 x 1/2" - Water outlet 7 Ø 13 1/2" 3 x 1/2" - Test valve and test kit yes* yes yes - Maintenance tap no no yes - Overload indicator no no yes - Body material PE PE PE PE Dimensions (H_W_D) 00 x 21 x 270 5 x 700 x 300 1155 x 1040 x 435 900 x 85 x 390- Weight 4,5 14 48 38 Compressor flow rate 0 to 108 m 3 /h 0 to 480 m 3 /h 0 to 2,100 m 3 /h 2 100 to 4,200 m 3 /h Article code SPH 110 SPH 480 SPH 2100 SPH EXT Spare pre-filter cartridge SPH 110 CAF SPH 480CAFW SPH 2100CAFW Spare activated carbon cartridge SPH 480CAFB SPH 2100CAFB SPH EXTCAFB Registered office : Prevost SAS Parc d activités des Glaisins - B.P. 208 FR - 74942 ANNECY-LE-VIEUX CEDEX - FRANCE Tel. 00 33 (0)4 50 4 04 45 - Fax 00 33 (0)4 50 4 00 10 E mail : sales@prevost-ltd.com Web : www.prevost-ltd.com * kit not included Published by Prevost - This document may not be deemed contractually binding. To provide better service for customers, Prevost reserves the right to alter product characteristics without notice.