Project: Municipal theatre Rüsselsheim Fire dampers with spring return actuators and smoke detection

Similar documents
Building system automation. How to use

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Safe area; Zone 1 and Zone 2

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Product overview. Alarm indicator, operator and display panels

SUPREMATouch. Modular Fire & Gas Detection System

Parameterisable compact fault annunciator with permanent display

Engineering Guideline. pac- Carriers Type Universal

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

SUPREMATouch. Modular Fire & Gas Detection System

The integral solution for. Air Handling Units. Technology & Evolution

FC700A Fire detection control unit

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Fire damper actuators. Selection and integration.

Automation at first hand. years

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Original operating instructions Safety switch with guard locking AC901S AC902S

21-light Remote Annunciator. Owner s Manual

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Panel Mounted Fault Annunciator Series

The Next Generation Machine Protection System

Fire and Gas Monitoring Panel ST7-HV

Project: Municipal swimming pool Plauen. Author: Heiko Peters Viktor Schauberger ( ) Austrian natural scientist and inventor

D7024 Fire Alarm Control Panel

Integrated Security Solutions

Intelligent Security & Fire Ltd

Different types of Fire Alarm System

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

Industrial Grade Gas Detection Detecting The Difference

RS485 MODBUS Module 8AI

High Efficiency Burner Controls Beyond Efficiency June 7, 2016

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Signal Processing System ME30 infobox

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Frequently asked questions: Intelligent Transmitter Series

Integrated Security Solutions

Instrumentation Products and Applications

THE NEXT SMART HOME GENERATION

Panel Mounted Fault Annunciator Series

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

INTELLIGENT HOME AUTOMATION IS JUST THAT SIMPLE

Insulation fault evaluator EDS460-DG

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Modular Fire Panel 5000 Series Just as flexible as your plans

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

B.E.G. LUXOMAT net. DALISYS Intelligent Lighting Control and more

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Universal fault annunciator for panel mounting

System 9000TS Sequence of Events Recorder

One giant leap for safety: AZM400.

Dräger REGARD 3900 Series Control System

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

For Complete Fire and Gas Solutions

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

Dehumidifying Dryers DP DP 615 Series

Burner control unit BCU 370

Speed and Frequency Seite 1 von 7

Window facia fault annunciators

Remote alarm indicator and test combination MK2430

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

LF /2. Fire Alarm Control Panel. Features:

Electronic controllers. Comfort embellishes everyday life

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

explosion protection automation global partner of the process industry

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

On the job around the clock 24/7: Fire detection systems

Synova TM product catalog.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

IntesisBox BACnet/IP Server - Notifier ID3000 series

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

KEMPER ThermoSystem. For further information on KTS use the QR code!

AU MX Digital Loop Card Installation Instructions

Solution F2. Fire Alarm Control Panels one step ahead.

Helios in a new dimension.

TrueAlarm Analog Sensing

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

SUPREMATouch Modular Fire & Gas Detection System

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Transcription:

Project: Municipal theatre Rüsselsheim Fire dampers with spring return actuators and smoke detection in building services automation ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 1

Why is there a bus in the theatre? In the past the technical systems in buildings lagged behind industrial technology by many years. Nowadays the common parallel wiring is very often used for modification and set-up of electrical installations even in huge buildings. But especially for the modernisation of buildings it is important to use a field bus system which enables the use of existing installation systems in the building with minimum wiring efforts. Especially for new building complexes a system which saves cable ducts and reduces environmental damage due to fire by up to 80 % due to reduced cable lengths is more and more often required. AS-Interface (AS-i) - is such a field bus system which reduces environmental damage due to fire considerably and saves costs. AS-Interface is used in automation technology world-wide, which is shown by the number of more than 1 million slaves used. For almost a decade this system has been used in small and in big installations, especially in areas susceptible to interference. Especially for building automation AS-i benefits from its considerable advantages: cost savings, easy to use and considerably reduced environmental damage due to fire. System set-up in the project The control concept is based on the AS-Interface field bus system. All fire dampers are divided into five AS-i lines and are connected with one AS-i master per line via the yellow flat cable. These AS-i masters are in the controller (with 1 or 2 masters) which is the central control unit of the AS-Interface. The smoke sensing devices are also connected to the field bus via the flat cable. The field bus connection of dampers and smoke sensing devices is made by means of AS-i isolation displacement connection. Each controller in the project has a second RS485 interface in addition to its RS232 programming interface. All four controllers are interconnected via this interface. One controller is the master controller and enables the exchange of data with the remote (slave) controllers. In the individual controllers all functions of the dampers are programmed with the plc programming language (to IEC 61131-3) and thus preprocessed. Only defined signals are exchanged with the higher system (building services control system). The programming in the higher building services control system is considerably reduced and less expensive. ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 2

AS-i connection of the fire damper Figure 1: fire damper with spring return actuator and AS-i connection via the classic 2I/2O module All fire dampers have been equipped with spring return actuators by Belimo in the factory. The dampers are equipped with the AS-i modules and directly delivered to the construction site by the manufacturer TROX. The actuator and the upper part of the AS-i module are connected via plug and socket connection. For installation on the construction site only the yellow and/or the black flat cable are inserted in the profiled ducts of the lower part. By screwing the upper part onto the lower part the contact between the module and the flat cable and thus the controller is made. AS-i connection of the smoke sensing devices in the field In the factory the TROX smoke sensing devices of type RM-O-VS are also premounted on an air duct with AS-i connection. By means of isolation displacement connection the yellow and the black flat cable are connected with the housing of the AS-RM module which is mounted at the air duct. The smoke sensing device is supplied with voltage via the AS-i module installed in the housing which enables a test function of the smoke sensing device via AS-Interface. Moreover the operating state of the smoke sensing device, the airflow monitoring, soiling warning (> 70%) and smoke alarm of the ventilation system can be indicated to the AS-i controller and thus to the higher control systems via the AS-i module. When smoke is detected, all dampers or damper groups are brought into the safe state (position CLOSED) via the AS-i controller. Figures 2a a. 2b: smoke sensing device with AS-i connection ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 3

Connection to building services control system Figure 3: Data transfer via relay contact (4I/4O modules) Visualisation options To guarantee a fast and inexpensive connection to the building services control system, relay contacts were selected for signal transfer. Relay contacts of the building services control system transfer commands to the master controller and relay contacts of the AS-i control cabinet modules (4I/4O) transfer group fault messages and individual status messages to the buiding services control system. The complete ventilation system is divided into eight subinstallations which have their own group fault messages and building services control system commands. The second interface of the controller enables easy serial connection to higher systems. For these defined interfaces, such as Profibus-DP, Interbus, DeviceNet, Modbus, (LON is being developed at present) ifm electronic gmbh already offers an AS-i controller or AS-i gateway which has already been used in many projects. Illuminated push-buttons have been selected to indicate the individual states of the fire dampers. The state "damper open" is indicated by a green permanent light. The state "damper closed" is indicated by a red permanent light. If a damper moves, a green light flashes. A failure of a damper results in red flashing light. All fault messages remain stored until they have been acknowledged. By pressing a button, one damper is moved in the manual mode or a group of dampers is moved in the automatic mode. There is also a test LED and a test/fault indication for each smoke sensing device. The state of fire dampers can also be visualised by PC or touch screen (via RS232C), indication and operating panel (via RS232C), LED/push-button module TROX type AS-MO (via RS485) or via the higher building services control system. Figure 4: panel with illuminated push-buttons for each damper ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 4

Considerably shorter cable lengths Each cable laid in the installation results in a number of subsequent costs. Cables have to be fixed, require cable ducts, must be stripped and connection errors are made easily. AS-i offers a two-wire tree structure and can be branched at any position. It is thus possible to save considerable cable lengths. In this project approx. 30 km NYM cables would have been necessary for parallel wiring. The use of AS-i reduces this to only approx. 800 m AS-i flat cable. Not only the cables but also the described subsequent costs could be reduced. Figure 5: Comparison of conventional wiring and AS-Interface with the example of a flat cable branching Problem of heat resistance (E30 / E90) Figure 2: channel with fire protection housing Even under difficult conditions because of rigid fire protection specifications AS-Interface (AS-i) can be used without problems. AS-i module lower parts with SC connection enable use of standard round cables (> with increased functional endurance in case of fire (E30/E90)). The cable types can be mixed since the module lower parts are suited for flat cables by means of the SC connection as well as round cables. For desmoking flaps test showed that the modules plus cable have a better heat resistance than the actuators. The yellow flat cable can also be laid in the Procan channels at any time. Especially in the applications with increased fire protection requirements, the bus system pays off thanks to the considerable reduction in cables. ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 5

Advantages of AS-i in this project faster installation reduced material requirements for cables fewer cable ducts fewer terminal chambers reduced cabling, easier installation faster set-up diagnostic functions failure detection of dampers shorter maintenance thanks to display panel set-up and installation without higher system signal preprocessing relieves the building services control system all functions even without higher system extension of installation possible without changes in the control cabinet We would like to thank all companies and persons involved for the good cooperation. Instead of a tangle of cables.. simply AS-i. ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 6

Companies involved: Object: Stadttheater Rüsselsheim Tel.: +49 6142 83 26 20 Am Treff 7 Contact: Mrs. Winkler D-65428 Rüsselsheim General supervision: Hochbauamt Stadt Rüsselsheim & IBG Ing-Büro Taunusstr. 11 Franz-Dietz-Str. 11 D-65424 Rüsselsheim 61440 Oberursel Tel.: +49-6142 - 83-0 Tel.: +49 6171 982 036 Contact: Mr Schneider Contact: Mr Gernet Planning and implementation of ventilation systems and AS-i connections: Helmut Herbert GmbH & Co. Tel.: +49 6251 5960-36 Bensheimer Straße 23 D-64683 Einhausen Contact: Mr Bartelt Connection to building services control systems and control cabinet concept: Haitech Automations GmbH Tel.: +49 9374 9712-0 Elsava Straße 171 D-63863 Eschau Contact: Mr Martin Supplier of fire dampers with AS-i connection: Gebrüder Trox GmbH Tel.: +49 69 531 086 Vertriebsgruppe Süd-West e-mail: vgsw.nlf@troxtechnik.de D-60433 Frankfurt/Main Contact: Mr Gaber The following ifm employees were involved in the project: Mr Kluge ifm Essen VBP1 Tel.: +49 7062 9595-10 Mr Gundermann ifm Essen VBP1 Tel.: +49 7062 9595-23 Mr Schreiter ifm Essen Tel.: +49 201 2422-243 Mr Strauss ifm NL we Tel.: +49 201 36475-34 If you have any questions regarding this project report or if you are interested in other reports please contact: ifm electronic gmbh Sales specialists engineering offices Seestraße 5/1 D-74232 Abstatt Tel.: +49 70 62 / 95 95-0 Fax: +49 2 01 / 24 22-16 54 E-mail: ProjektService@ifm-electronic.com www.ifm-electronic.com ifm electronic gmbh Assembly and Process Automation Process Industry KIP - gu Page 7

Project scheme Municipal theatre, Rüsselsheim Central control cabinet: Master controller, AC1012 AS-i dual power supply, AC1212 24VDC power supply, DN2013 Repeater, AC1015 AS-i power supply, AC1206 Control cabinet SS-2: Remote controller, AC1011 AS-i dual power supply, AC1212 24VDC power supply, DN2013 Repeater, AC1015 AC2801: Relay modules for data transfer to higher system AC2351: Unit with 8 illuminated push-buttons (25 units) Control cabinet SS-3: Remote controller, AC1011 AS-i dual power supply, AC1212 24VDC power supply, DN2013 Repeater, AC1015 RM RM Control cabinet SS-4: Remote controller, AC1011 AS-i dual power supply, AC1212 24VDC power supply, DN2013 Repeater, AC1015 RM Controlling via software RM This is only a scheme. Since the size of the plant and the local conditions are not exactly known the system must be set up according to the requirements on site. Repeater AC1015 Smoke sensing devices ifm electronic gmbh essen Environmental Technology and Building System Autom. Project: Municipal theatre, Rüsselsheim Plan: Intelligent wiring system AS-Interface Date: Created by: KIE - me Plan no.: egea_6