INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

Refrigerated Air Dryer

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.

Refrigerated Air Dryers

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications

Refrigerated Air Dryer

Discrete type for different piping conditions VSH/VSU/VSB/VSC. Features

Membrane Air Dryer IDG10,IDG10H IDG20,IDG20H

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Refrigerated Air Dryer Large Size Series

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Refrigerated Air Dryers

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Valve timing. Atmospheric air

Refrigerated Air Dryer

Refrigerated Air Dryers

Membrane Air Dryer IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA

Refrigerated Air Dryers

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series

Crimping Press 82CE-061 Portable crimper for braided hoses

Karman Vortex Flow Meter KSL-5/10/30/50LN

Pressure Switches Precautions 1 Be sure to read this before handling.

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

TEMPERATURE CONTROLLERS

Vacuum Generators. Ejector for Various Piping Conditions

Multistage Ejector MODEL / Series / Product Number

Hollow Fiber Membrane Filter Type Air Drier Unit Type

Refrigerated Air Dryer

Filter and Regulator Combination Unit Series

Vacuum system component SELVACS

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

HP310-C EXTRACTOR 120V

Medium main line filter

A/C COMPRESSOR OIL CHECKING

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300

Electron Microscopy Sciences

Model Selection. Data. Selection Graph. Selection Graph (2) Piping Capacity by Tube I.D.

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

External Vacuum Controller with Blow-off Air and Relief Pressure Adjustment. External Vacuum Controller Series

COBRA -300H EXTRACTOR

Refrigerated Air Dryer

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Prevents condensation

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Manual Desiccant Dryer Numbering System

southbend OWNER'S MANUAL INSTALLATION USER'S GUIDE DIRECT STEAM TILTING KETTLE MODELS: KDLT, KDPT

Models: GW/R-T GW/R-2-T GW/R-3-T

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

Thanks for shopping with Improvements! Evaporative Air Cooler with Adjustable Flow Valve Item #437979

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

INSTALLATION INSTRUCTIONS

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

REFRIGERANT SERVICE TOOLS VACUUM PUMPS / ACCESSORIES

SECTION METERS AND GAUGES FOR HVAC PIPING

Refrigerated Air Dryer

% by up ctoond re-heater and

General System Layout Sketch

Installation, commissioning and servicing instructions

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Husky Diaphragm Pump Suction Kits

BASIL 6000 TUNNEL CAGE WASHER

Davies Carries Parts for MF & SF Series Glycol Feeders

DRYAIRE DESICCANT SYSTEM MODEL 6760

HYDRO-GUARD HG-1-BASIC/S ATMOSPEHERIC DISCHARGE DEVICE CONSTRUCTION FOR ABOVE GROUND INSTALLATIONS 1. GENERAL DESCRIPTION 2.

Manual Addendum For Dyna-Fog Hurricane ES

Refrigerated Air Dryer

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

TECH REPORT 200: Use of Water Traps and Drying Filter with the FX-5000 Tension System. Document: Water Trap and Drying Filter Tech Report, Rev. 8.

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Membrane air dryers MS-LDM1, MS series

High efficiency compressed air filtration. Truly Innovative Compressed Air Purification. LF Series

EH0554 Indoor Climate Control

INSTALLATION INSTRUCTION

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

THE THERMOSTATIC STEAM TRAP

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

INSTALLATION INSTRUCTIONS WARRANTY

PROPANE GAS HEATER MODEL NO: DEVIL 4000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS GC ISS 4

LOELubricators DSeries,NPT Technical Data

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

Vacuum Pad. New More shapes and sizes of pads. Applicable for various types of work pieces. Series ZP2. ø0.8 to ø15 P. 1 to 9. ø4 to ø125 P.

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Page 1 of 18. Part# /5/2013

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

Low dew point type. Discrete standard dew point type (SD3015-B) (SD3035-B) (SD3050-B) (SD3075/4050-B) (SD4075-B) (SD4100-B) (SD3015-A)

Transcription:

Separator for Vacuum Series M emoves water droplets from air by simply installing in vacuum lines. Prevents damage of vacuum pumps and ejectors. Ejector Z Z Z M MV EP elated separator for vacuum side port solenoid valve side Cleaning water Pad Courtesy of Steven Engineering, Inc.-30 yan Way, South San Francisco, C 94080-3-Main Office: (50) 588-0-Outside Local rea: (800) 58-0-www.stevenengineering.com 13

Separator for Vacuum Series M ohs Over % of water droplets can be removed through the use of a special water droplet removing element. The provision of a drain cock makes it possible to discharge the drain manually after breaking the vacuum. Even when the element is saturated with water, there is almost no drop in pressure (increase in resistance). The element can be replaced with a single touch. M 30 Body size 30 3/8 40 1/ 50 3/4 Thread type Nil c F G N NPT 00 /Combinations How to Order Port size 0 1/4 03 3/8 04 1/ 0 3/4 10 1 03 Combination available Pressure gauge position Nil None B Bracket Nil cock Metal bowl Nylon bowl guide (c 1/4) Flow: ight Left If ordering two options or more, indicate symbols numerically and alphabetically. Without valve function (It needs drain piping and piping for a stop valve like ball valves, etc.) Combination not available cock Metal bow Nylon bowl guide Flow: ight Left Symbol Nil Nil M3000 M4000 M5000 ecommended flow rate (l/min (N)) 00 300 500 Port size (Nominal size B) 1/4, 3/8 3/8, 1/ 3/4, 1 Mass (kg) 0.3 0. 1.1 Specifications Fluid Maximum operating pressure Minimum operating pressure Proof pressure mbient and fluid temperature Water drop removal ratio Element life ir 1.0 MPa 750 mmhg 1.5 MPa 5 to 0 C % years or when pressure drops to 0.0 MPa ccessory () pplicable model Bracket assembly (With mounting screws) M3000 M4000 M5000 F30P-050S F40P-050S F50P-050S 14 Courtesy of Steven Engineering, Inc.-30 yan Way, South San Francisco, C 94080-3-Main Office: (50) 588-0-Outside Local rea: (800) 58-0-www.stevenengineering.com

Separator for Vacuum Series M How to Order Bowl ssembly M C 30 Symbol 30 40 Body size pplicable body size M3000 M4000, 5000 0.01 0.005 0.001 0.0005 Nil Polycarbonate bowl (1) Metal bowl Nylon bowl (1) Note 1) The bowl assembly includes a bowl guard (Material: CE). Flow Characteristics Supply pressure (MPa) M5000 M4000 M3000 0.0001 10 50 100 500 1000 ir flow rate (l/min (N)) Construction Thread type (3) Nil c F G N NPT Note 3) Select in line with the thread type on the discharge cock guide (c 1/4) () Note ) Without valve function (It needs drain piping and piping for a stop valve like ball valves, etc.) Fluid: ir (pressurized) Measured pressure: Downstream release to atmosphere q q Z Z Z y r w e t w y r e M MV EP elated Component Parts No. Description 1 Body Material luminum die-casted Note Platinum silver coated eplacement Parts No. Description Material Part no. M3000 M4000 M5000 3 4 5 Element assembly Bowl assembly Note) O-ring O-ring Spacer M-EL3000 M-C30- C3SFP-0S 3073 M-EL4000 M-C40- C4SFP-0S 307433 M-EL5000 M-C40- C4SFP-0S 111710 30751 Note) efer to the above for How to Order Bowl ssembly. The spacer y is not included in the bowl assembly. Courtesy of Steven Engineering, Inc.-30 yan Way, South San Francisco, C 94080-3-Main Office: (50) 588-0-Outside Local rea: (800) 58-0-www.stevenengineering.com 15

MX.D LEVEL MX.D LEVEL Series M Dimensions M3000, 4000 L G K D F M Bracket () C space 40 E H Vacuum x port size Discharge guide (-) c 1/8 P 1/4 female thread without valve function Hexagon width across flats 4 M5000 L G K D F M Bracket () space 0 C B E H x port size Vacuum c 1/8 Port size M3000 M4000 M5000 1/4, 3/8 3/8, 1/ 3/4, 1 Note) ( ) is the case for metal bowl. C D B Note) 14 (15) 00 (03) 79 (81) 14 18 4 Bracket mounting dimensions E F G H K L M 1 17 3 41 50 40 54 3 35.5 8.5 11 8 10.5 13.3.3 3. (mm) With drain guide Note) 158 (10) 194 (195) 73 (74) 1 Courtesy of Steven Engineering, Inc.-30 yan Way, South San Francisco, C 94080-3-Main Office: (50) 588-0-Outside Local rea: (800) 58-0-www.stevenengineering.com

Series M Specific Product Precautions Be sure to read before handling. efer to front matters 38 and 39 for Safety Instructions and pages 844 to 84 for Vacuum Precautions. separator for vacuum port solenoid valve side Cleaning water on Design 1. When using with repeating positive pressure and negative pressure: Use at 0.1 MPa or less of positive pressure when the repeating tact is fast. The vessel may be hotter depending on the pressure and repeating tact conditions. Mounting 1. ir piping should be thoroughly flushed before mounting.. When piping and fittings, etc. are being screwed together, be certain that cutting chips from the pipe threads, sealing material, and other debris do not get inside the piping. Further, when pipe tape is used, leave 1.5 to thread ridges exposed at the end of the pipe. 3. The unit should be mounted vertically. 4. When piping is being installed, connect for work side and for ejector or vacuum pump. Ejector side Warning Bowl Capacity M3000 M4000, 5000 Operating Environment 1. Since the case material is polycarbonate, avoid using chemicals such as thinner, carbon tetrachloride, chloroform, aniline, cyclohexan, trichloroethylene, sulfric acid, lactic acid or watermiscible cutting fluid (alkaline), etc. Operation of the product in an atmosphere containing any of these chemicals should also be avoided. neutral detergent may be used for cleaning the bowl.. void use exposed to direct sunlight. 1. The element should be replaced after years of use, or before the pressure drops to 0.0 MPa (0. kgf/cm ). The spacer and O-ring should also be replaced at the same time that the element is replaced. Sometimes when the bowl is removed for a purpose other than replacing the element, the spacer may stick to the bowl and come off. In this case however, it may be returned to its installed position and used again.. age should be discharged by the time it reaches the upper limit. Furthermore, when drainage is to be discharged or the element replaced, first confirm that all equipment, etc is stopped, and return the interior of the bowl to atmospheric pressure before proceeding. 45 cm 3 105 cm 3 Z Z Z M MV EP elated Pad 5. When drainage is discharged automatically, install port solenoid valve and activate it in such an operation cycle like the drainage should be discharged by the time it reaches the upper limit. But when discharging it, return the case interior to atmospheric pressure before proceeding. Courtesy of Steven Engineering, Inc.-30 yan Way, South San Francisco, C 94080-3-Main Office: (50) 588-0-Outside Local rea: (800) 58-0-www.stevenengineering.com 17