TABLE OF CONTENTS RMXS-E8V1B

Similar documents
technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

TABLE OF CONTENTS ERSQ-AAY1

TABLE OF CONTENTS ERHQ BAV3

EEDEN technical data ERHQ AA. Altherma. Altherma

Air Conditioning Technical Data RZAG-MV1

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

Air Conditioning Technical Data RZASG-MV1

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

technical data air conditioning systems RZQ B8W1B Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

EEDEN technical data ERHQ AA

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

Air Conditioning Technical Data AZAS-MY1

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Service Manual. Air Cooled Refrigeration Condensing Unit

Air Conditioners. Technical Data RZQG-L

technical data air conditioning systems Indoor Units FCQ-C8VEB

Heating. Technical Data EEDEN ERRQ-AY1

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Air Conditioning. Technical Data EEDEN AZQS-BV1

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

TABLE OF CONTENTS EDLQ AA6V3

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

TABLE OF CONTENTS EBLQ01-016AA6V3

Digital Inverter 4 series 8 & 10HP

Air Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1

EDUS Heat Pump - D-Series

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air Conditioners. Technical Data FTXS-G

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Conditioning. Technical Data. VRV IV S-series heat pump EEDEN16-200_2 RXYSQ-TV1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

PUHZ-SHW140YHA PUHZ-SHW230YKA

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data EEDEN RXS-F8

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

R4H4. Product Specifications

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

DESIGN & TECHNICAL MANUAL

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

PURY-P200YMF-C, PURY-P250YMF-C CONTENTS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Water cooled VRV IV W-series

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

DESIGN & TECHNICAL MANUAL

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

TECHNICAL DATA & SERVICE MANUAL

R4H4. Product Specifications

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

AIR-CONDITIONER SERVICE MANUAL

DESIGN & TECHNICAL MANUAL

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

DESIGN & TECHNICAL MANUAL

REYQ72-456TTJU REYQ72-456TYDN R-410A

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

General Outline: Altherma

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

SERVICE MANUAL MUH-A18WV - MUH-A24WV - MUH-A30WV - E1. Wireless type Models HFC

N4H4. Product Specifications

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

Transcription:

Outdoor Units R-410A RMXS-E8V1B TABLE OF CONTENTS RMXS-E8V1B! 1 Features........................................................... 814 2 Specifications..................................................... 815 Nominal Capacity and Nominal Input.............................. 815 Technical Specifications........................................... 815 Electrical Specifications............................................ 817 Electrical data..................................................... 818 4 Options............................................................ 819 5 Capacity tables................................................... 820 Cooling capacity tables............................................ 820 Heating capacity tables............................................ 826 Capacity correction factor.......................................... 82 6 Dimensional drawing & centre of gravity...................... 84 Dimensional drawing............................................... 84 Centre of gravity................................................... 8 7 Piping diagram.................................................... 86 8 Wiring diagram.................................................... 87 Wiring diagram..................................................... 87 External connection diagram....................................... 88 9 Sound data........................................................ 89 Sound pressure spectrum.......................................... 89 Sound power spectrum............................................ 841 10 Installation......................................................... 842 Installation method................................................. 842 11 Operation range.................................................. 844 Split Sky Air Outdoor Units 81

i n y k 1 r 8 o t o 0- i d 1 l t 4 pu- Outdoor Units R-410A RMXS-E8V1B 1 Features BU S V A E S X M RS O The RMXS gives you a high-capacity multi split system which combines the power and easy installation of a VRV outdoor unit with the quiet operation of residential - use indoor units. The Super Multi Plus has more than enough power to drive up to 9 indoor units, including a 7,1 kw class unit. An inverter driven compressor allows the capacity to be adjusted precisely to match variations in room and outside temperatures. A 1-meter piping length means there are now no restrictions on the choice of installation position for indoor units, greatly improving planning flexibility. 1 814 Split Sky Air Outdoor Units

2 Specifications Outdoor Units R-410A RMXS-E8V1B 2-1 NOMINAL CAPACITY AND NOMINAL INPUT RMXS112E8V1B RMXS140E8V1B RMXS160E8V1B Nominal Capacity Cooling capacity Standard kw 11.2 14.0 15.5 Heating capacity Standard kw 12.5 16.0 17.5 For combination EER Nominal.20 2.75 2.87 indoor units + outdoor units COP Nominal.18.07.22 Max. number of connectable indoor units (BP to be connected) 6 8 9 Min. / Max. total capacity index of I/U to be connected 55/145.5 70/182 80/108 2-2 TECHNICAL SPECIFICATIONS RMXS112E8V1B RMXS140E8V1B RMXS160E8V1B Casing Colour Daikin White Material Paintable galvanized steel plate Dimensions Unit Height mm 1,45 Width mm 900 900 900 Depth mm 20 20 20 Packing Height mm 1,524 Width mm 980 980 980 Depth mm 420 420 420 Weight Unit kg 120 120 120 Packed Unit kg 10 10 10 Heat Exchanger Dimensions Length mm 857 857 857 Nr of Rows 2 2 2 Fin Pitch mm 2 2 2 Nr of Passes 10 10 10 Face Area m² 1,11 Nr of Stages 60 60 60 Tube type Hi-XSS(8) Fin Type Non-symmetric waffle louvre Treatment Corrosion resistant Fan Type Propeller Discharge direction Horizontal Quantity 2 2 2 Air Flow Rate Cooling m³/min 106 106 106 (nominal at 20V) Heating m³/min 102 105 105 Motor Quantity 2 2 2 Model Brushless DC motor Motor Speed (nominal) Cooling rpm 850/815 Heating rpm 820/785 840/805 840/805 Fan Motor Output W 70 70 70 Drive Direct Drive Compressor Quantity 1 1 1 Motor Model JT100G-VDL@T2 Type Hermetically sealed scroll compressor Speed rpm 6,480 Motor Output W 2.5.0.5 Crankcase W Heater Starting Method Direct on line Operation Range Cooling Min CDB -5-5 -5 Max CDB 46 46 46 Heating Min CWB -15-15 -15 Max CWB 20 20 20 Sound Level (nominal) Cooling Sound Power dba 67 68 70 Sound Pressure dba 51 52 54 Heating Sound Pressure dba 5 54 55 Sound Level (Night quiet) Sound Pressure dba Step 1: 47Step 2: 44Step : 41 2 Split Sky Air Outdoor Units 815

2 Specifications Outdoor Units R-410A RMXS-E8V1B 2 2-2 TECHNICAL SPECIFICATIONS RMXS112E8V1B RMXS140E8V1B RMXS160E8V1B Refrigerant Type R-410A Charge kg 4.0 4.0 4.0 Control Expansion valve (electronic type) Nr of Circuits 1 1 1 Refrigerant Oil Type Daphne FVC68D Charged Volume l 1.5 1.5 1.5 Piping connections Liquid (OD) Quantity 1 1 1 Type Flare connection Diameter (OD) mm 9.52 9.52 9.52 Gas Quantity 1 1 1 Type Braze connection Diameter (OD) mm 19.1 19.1 19.1 Drain Quantity Type Hole Diameter (OD) mm 26x Piping Length System total m 115 1 145 Piping Length Total OU - BP m 55 55 55 BP - IU m 60 80 90 1 room BP - IU m 15 15 15 Piping connections Height difference OU - BP m 0 0 0 OU - IU m 0 0 0 BP-BP/IU-IU m 15 15 15 Additional Refrigerant Charge kg/m Refer to installation manual Installation height difference Maximum m 0 0 0 Max. internunit level difference m 15 15 15 Heat Insulation Both liquid and gas pipes Defrost Method Reversed cycle Defrost Control Sensor for outdoor heat exchanger temperature Capacity Control Method Inverter controlled Capacity control Cooling Minimum 24 24 24 Maximum 100 100 100 Heating Minimum 24 24 24 Maximum 100 100 100 Safety Devices High pressure switch Fan motor thermal protector Inverter overload protector PC board fuse Standard Accessories Item Gas connection pipe Quantity Item Installation manual Quantity 1 1 1 Item Operation manual Quantity 1 1 1 Item Drain socket Quantity 1 1 1 Item Drain cap Quantity 2 2 2 Item Drain receiver Quantity Item Insulation Quantity 1 1 1 816 Split Sky Air Outdoor Units

2 Specifications Outdoor Units R-410A RMXS-E8V1B 2-2 TECHNICAL SPECIFICATIONS RMXS112E8V1B RMXS140E8V1B RMXS160E8V1B Notes * Nominal cooling capacities are based on : indoor temperature : 27 CDB, 19 CWB, outdoor temperature : CDB, equivalent piping length: outdoor - BP: 5m / BP - indoor: m / level difference: 0m. * Nominal heating capacities are based on : indoor temperature : 20 CDB, outdoor temperature : 7 CDB, 6 CWB, equivalent piping length: outdoor - BP: 5m / BP - indoor: m / level difference: 0m. The sound power level is an absolute value indicating the power which a sound source generates. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. Sound values are measured in a semi-anechoic room. 2- ELECTRICAL SPECIFICATIONS RMXS112E8V1B RMXS140E8V1B RMXS160E8V1B Power Supply Name V1 Phase 1N~ Frequency Hz 50 50 50 Voltage V 220-240 Voltage range Minimum V -10% Maximum V +10% Current Nominal running current (RLA) Cooling A 15.9 20.2 22.2 Starting current (MSC) A 15.9 20.2 22.2 Min. circuit amp (MCA) A 27.0 27.0 27.0 Max. fuse amps (MFA) A 2.0 2.0 2.0 Full load amps (FLA) A 0.+0.(Fan motor) Wiring connections For Power Supply Quantity Remark (including earth wiring) For connection with Quantity 2 2 2 indoor Remark F1+F2 Power Supply Intake Both BP unit and outdoor unit Notes RLA is based on following conditions: indoor temperature: 27 CDB/19 CWB, outdoor temperature: CDB Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits Maximum allowable voltage range variation between phases is 2%. Select wire size based on the value of MCA Instead of fuse, use circuit breaker. MFA is used to select circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). MSC means the maximum current during start up of the compressor 2 Split Sky Air Outdoor Units 817

Electrical data Outdoor Units R-410A RMXS-E8V1B Power supply Current RMXS112EVB RMXS140EVB RMXS160EVB Name V1 Phase 1N Frequency Hz 50 Voltage V 220-240 Nominal running current (RLA) A 15.9 20.2 22.2 Starting current (MSC) A 15.9 20.2 22.2 Min. Circuit Amps (MCA) A 27.0 Max. Fuse Amps (MFA) A 2.0 Voltage range Wiring connections Power supply intake Full Load Amps (FLA) A 0. + 0. (Fan motor) Min. V 198 Max. V 264 For power supply Quantity Remark Earth wire included For connection with BP Quantity 2 Remark F1+F2 Both BP unit and outdoor unit TW0401-2 SYMBOLS MCA : Min. Circuit Amps MFA : Max. Fuse Amps (see note 5) RLA : Rated Load Amps (A) FLA : Full Load Amps MSC : Starting current (see note 6) NOTES 1 RLA is based on the following conditions: Indoor temperature 27 CDB/19 CWB Outdoor temperature CDB 2 4 5 6 7 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits Maximum allowable voltage variation between phases is 2% Select wire size based on the larger value of MCA Instead of fuse, use circuit breaker MFA is used to select the circuit breaker and the ground fault circuit interrupter (earth leakage circuit breaker). MSC means the maximum current during start up of the compressor. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 818 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 4 Options RMXS-EV N Item RMXS112 RMXS140 RMXS160 1 Drain plug KKPJ5F180 2 Refnet joint KHRQ22M20TA Branch provider (2 rooms) BPMKS967B2 4 Branch provider ( rooms) BPMKS967B *Note: all options are kits 4TW26791-2B 4 Split Sky Air Outdoor Units 819

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-1 Cooling capacity tables RMXS112EV- Cooling capacity Combination % Outdoor air temp. CDB Indoor air temp.: CWB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052905 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. 820 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-1 Cooling capacity tables RMXS112EV- Cooling capacity Combination % Outdoor air temp. CDB Indoor air temp.: CWB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052905 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. Split Sky Air Outdoor Units 821

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-1 Cooling capacity tables RMXS140EV- Cooling capacity Combination % Outdoor air temp. CDB Indoor air temp.: CWB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052906 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. 822 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-1 Cooling capacity tables RMXS140EV- Cooling capacity Combination % Outdoor air temp. CDB Indoor air temp.: CWB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052906 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. Split Sky Air Outdoor Units 82

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-1 Cooling capacity tables RMXS160EV- Cooling capacity Combination % Outdoor air temp. CDB Indoor air temp.: CWB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052907 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. 824 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-1 Cooling capacity tables RMXS160EV- Cooling capacity Combination % Outdoor air temp. CDB Indoor air temp.: CWB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052907 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. Split Sky Air Outdoor Units 825

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-2 Heating capacity tables RMXS112EV- Heating capacity Combination % Outdoor air temp. CDB Indoor air temp.: CDB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052908 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. 826 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-2 Heating capacity tables RMXS112EV- Heating capacity Combination % Outdoor air temp. CDB Indoor air temp.: CDB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052908 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. Split Sky Air Outdoor Units 827

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-2 Heating capacity tables RMXS140EV- Heating capacity Combination % Outdoor air temp. CDB Indoor air temp.: CDB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052909 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. 828 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-2 Heating capacity tables RMXS140EV- Heating capacity Combination % Outdoor air temp. CDB Indoor air temp.: CDB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052909 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. Split Sky Air Outdoor Units 829

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-2 Heating capacity tables RMXS160EV- Heating capacity Combination % Outdoor air temp. CDB Indoor air temp.: CDB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052910 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. 80 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 5 Capacity tables 5-2 Heating capacity tables RMXS160EV- Heating capacity Combination % Outdoor air temp. CDB Indoor air temp.: CDB 14 C 16 C 18 C 19 C 22 C 24 C TC PI TC PI TC PI TC PI TC PI TC PI kw kw kw kw kw kw kw kw kw kw kw kw 5 D052910 Symbols: TC: Total capacity (kw) PI: Power input (kw) Notes: 1. This table shows outdoor unit cooling capacity and power input. 2. Q Is specified point.. PI of indoor units is not included in the table. Split Sky Air Outdoor Units 81

5 Capacity tables 5 - Capacity correction factor Outdoor Units R-410A RMXS-E8V1B Capacity correction factor by the length of refrigerant piping (Reference) Rate of change in capacity by the main piping length Rate of change in cooling capacity Main piping length 5 10 15 20 25 0 40 45 50 55 Rate of change in cooling capacity 100.0% 98.6% 97.2% 95.9% 94.7% 9.5% 92.% 91.2% 90.1% 89.1% 88.1% Rate of change in heating capacity Main piping length 5 10 15 20 25 0 40 45 50 55 Rate of change in heating capacity 100.0% 99.5% 99.1% 98.6% 98.2% 97.7% 97.% 96.9% 96.4% 96.0% 95.6% Rate of change in capacity by the main piping length 5 Rate of change in capacity (%) Rate of change in cooling capacity Rate of change in heating capacity Main piping length (m) L1 In both cases, the outdoor unit is in inferior or superior position for the indoor unit, the rate of change in capacity is the same. Rate of change in capacity by the branch piping length (1) Refrigerant piping connection diameter liquid J6.4 gas J15.9 Rate of change in capacity Piping length Cooling Heating 100.0% 100.0% 5 99.6% 99.9% 10 98.7% 99.6% 15 97.9% 99.% () Refrigerant piping connection diameter liquid J6.4 gas J9.5 Rate of change in capacity Piping length Cooling Heating 100.0% 100.0% 5 98.0% 98.8% 10 9.4% 96.0% 15 89.% 9.5% (2) Refrigerant piping connection diameter liquid J6.4 gas J12.7 Rate of change in capacity Piping length Cooling Heating 100.0% 100.0% 5 99.1% 99.5% 10 96.9% 98.2% 15 94.8% 97.0% Piping size for field connection (mm) (KW) RA SA liquid gas liquid gas 25 J9.5 J9.5 J6.4 50 J6.4 J12.7 60 J15.9 71 J15.9 J9.5 Notes 1 These figures illustrate the rate of change in capacity of a standard indoor unit system at maximum load (with the thermostat set to maximum) under standard conditions. Moreover, under partial load conditions there is only a minor deviation from the rate of change in capacity shown in the above figures. 2 With this outdoor unit, evaporating pressure constant control when cooling, and condensing pressure constant control when heating is carried out. System layout of piping Outdoor unit Piping length: L1 = 5m L2 = m BP unit Indoor unit 82 Split Sky Air Outdoor Units

5 Capacity tables 5 - Capacity correction factor Outdoor Units R-410A RMXS-E8V1B (1) Refrigerant piping connection diameter liquid: J6.4 gas: J15.9 Cooling Heating Rate of change in capacity (%) Branch piping length (m) L2 (2) Refrigerant piping connection diameter liquid: J6.4 gas: J15.9 Cooling Rate of change in capacity (%) Heating 5 Branch piping length (m) L2 () Refrigerant piping connection diameter liquid: J6.4 gas: J15.9 Cooling Heating Rate of change in capacity (%) Branch piping length (m) L2 Method of calculating cooling / heating capacity: Total capacity from capacity tables x (Rate of change in capacity by main piping length x rate of change in capacity by branch piping length). Split Sky Air Outdoor Units 8

Outdoor Units R-410A RMXS-E8V1B 6 Dimensional drawing & centre of gravity 6-1 Dimensional drawing RMXS-EV Hole for anchor bolt 4-M12 1 Gas pipe connection A 2 J9.5 flare Service port (in the unit) 4 Electronic connection and grounding terminal MS (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock hole J4) 7 Control wiring intake (knock hole J27) 8 Drain outlet model RMXS112E8V18 RMXS140E8V1B RMXS160E8V1B A J19.1 Brazing J19.1 Brazing J19.1 Brazing 6 TW0741 84 Split Sky Air Outdoor Units

Outdoor Units R-410A RMXS-E8V1B 6 Dimensional drawing & centre of gravity 6-2 Centre of gravity RMXS-EV 6 Position of foundation bolt 4D052604 Split Sky Air Outdoor Units 8

7 Piping diagram Outdoor Units R-410A RMXS-E8V1B RMXS-EV Electronic expansion valve Double pipe heat exchanger Electronic expansion valve Filter Heat exchanger Pressure regulating valve Filter Service port 4-way valve Capillary tube Service port Filter Low pressure sensor High pressure sensor Solenoid valve Filter Capillary tube Oil separator Filter Compressor 7 Accumulator High pressure switch Capillary tube Solenoid valve Stop valve (with service port on field piping side J 7.9mm flare connection) D052712 86 Split Sky Air Outdoor Units

8 Wiring diagram 8-1 Wiring diagram Outdoor Units R-410A RMXS-E8V1B RMXS-EV Cool / Heat selector S1S : Selector switch (Fan/Cool - Heat) S2S : Selector switch (Cool - Heat) Connector of option adaptor X7A : Connector (Note 4) (option adaptor power supply) A1P : Printed circuit board (Main) A2P : Printed circuit board (INV.) AP : Printed circuit board (Noise filter) A4P : Printed circuit board (C/H selector) BS1 BS5 : Push button switch (Mode, set, return, test, reset) C1 C4 : Capacitor DS1 : Dip switch E1HC : Crankcase heater F1U,F4U : Fuse (T 6.A/250V) F6U : Fuse (T 5.0A/250V) FINTH : Thermistor (fin) H1P H8P : Light emitting diode (service monitor orange) : Prepare test ----------- Flickering [H2P] : Malfunction detection--- Light up HAP Light emitting diode (service monitor green) (A1P) HBP : INV. pilot lamp (service monitor green) (A1P) K1M : Magnetic contactor (M1C) K2R : Magnetic relay (K1M) K1R : Magnetic relay (Y1S) K2R : Magnetic relay (Y2S) K4R : Magnetic relay (YS) K5R : Magnetic relay (E1HC) L1R : Reactor M1C : Motor (compressor) M1F : Motor (fan) (upper) M2F : Motor (fan) (lower) PS : Switching power supply Q1DI : Field earth leak detector (0mA) R1 : Resistor R2 : Resistor R1T : Thermistor (Air) R2T : Thermistor (Discharge) RT : Thermistor (Suction 1) R4T : Thermistor (Heat exchanger) R5T : Thermistor (Suction 2) R6T : Thermistor (subcooling HEX) R7T : Thermistor (Liquid pipe) S1NPH : Pressure sensor(high) S1NPL : Pressure sensor(low) S1PH : Pressure switch (High) V1R : Power module V2R,VR : Diode module V1T : IGBT X1M : Terminal strip (Power supply) X2M : Terminal strip (Control) Y1E : Electronic expansion valve (Main) YE : Electronic expansion valve (Subcool) Y1S : Solenoid valve (4 way valve) Y2S : Solenoid valve (Hot gas) YS : Solenoid valve (U/L circuit) Z1C Z7C : Noise filter (ferrite core) Z1F Z4F : Noise filter Outdoor Position of compressor terminal Wire entrance Notes: 1. This wiring diagram only applies to the outdoor unit 2. L: Live, N: Neutral, : Field wiring. : Terminal strip : Connector : Connection Protective earth : Relay connector : (screw) : Noiseless earth : Terminal 4. When using the option adaptor, refer to the installation manual 5. Refer to the wiring diagram sticker (on back of front plate) on how to use BS1 - BS5 and DS1, DS2 switch 6. Do not operate the unit by short-circuiting protection device S1PH 7. Refer to the installation manual for connection wiring to PB unit - outdoor unit transmission F1-F2 8. When using the central control system, connect outdoor-outdoor transmission F1-F2. 9. Colours: WHT: White / RED: Red / BLU: Blue / BRN: Brown / GRN: Green / YLW: Yellow Cool / Heat selector Cool C/H selector Heat Air control To BP unit (Note 8) BP unit To out/d unit (Note 9) Outdoor Component location (Back) (Note 4) (Front) 8 2TW27606-1A Split Sky Air Outdoor Units 87

8 Wiring diagram Outdoor Units R-410A RMXS-E8V1B 8-2 External connection diagram RMXS112-160EV Outdoor unit Power supply Fuse 2 wires cable Transmission line 2 wires cable Transmission line 2 wires cable Transmission line Power supply Power supply Power supply Fuse wires cable Power line Fuse wires cable Power line Fuse wires cable Power line BP units 8 4 wires cable Power line and transmission line Indoor units 4 wires cable Power line and transmission line 4 wires cable Power line and transmission line When the power source is suppled to each BP unit individually. NOTES 1 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. 2 Use copper conductors only. See wiring diagrams for details. 4 Install circuit breakers for safety. 5 All field wiring and components must be installed by a licensed electrician. 6 Units shall be grounded in compliance with applicable local national codes. 7 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. 8 Be sure to install the switch and the fuse to the power line of each equipment. Outdoor unit Power supply Fuse 2 wires cable Transmission line 2 wires cable Transmission line 2 wires cable Transmission line Power supply Fuse wires cable Power line wires cable Power line wires cable Power line BP units 4 wires cable Power line and transmission line 4 wires cable Power line and transmission line 4 wires cable Power line and transmission line Indoor units When the power source is connected in series between the units. 88 Split Sky Air Outdoor Units

9 Sound data 9-1 Sound pressure spectrum Outdoor Units R-410A RMXS-E8V1B RMXS112EV- Cooling RMXS112EV- Heating Octave band sound pressure level db:(0db = 0.0002 μ bar) Octave band sound pressure level db:(0db = 0.0002 μ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D05417A NOTES 1 The operating sound is measured in anechoic chamber, if it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound reflection. 2 Measuring place: anechoic room Octave band center frequency (Hz) Location of microphone 4D054141A NOTES 1 The operating sound is measured in anechoic chamber, if it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound reflection. 2 Measuring place: anechoic room Octave band center frequency (Hz) Location of microphone 9 RMXS140EV- Cooling RMXS140EV- Heating Octave band sound pressure level db:(0db = 0.0002 μ bar) Octave band sound pressure level db:(0db = 0.0002 μ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D05418A NOTES Octave band center frequency (Hz) 4D054142A NOTES Octave band center frequency (Hz) 1 The operating sound is measured in anechoic chamber, if it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound reflection. 2 Measuring place: anechoic room 1 The operating sound is measured in anechoic chamber, if it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound reflection. 2 Measuring place: anechoic room Location of microphone Location of microphone Split Sky Air Outdoor Units 89

9 Sound data 9-1 Sound pressure spectrum Outdoor Units R-410A RMXS-E8V1B RMXS160EV- Cooling RMXS160EV- Heating Octave band sound pressure level db:(0db = 0.0002 μ bar) Octave band sound pressure level db:(0db = 0.0002 μ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 9 4D05419A NOTES 1 The operating sound is measured in anechoic chamber, if it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound reflection. 2 Measuring place: anechoic room Octave band center frequency (Hz) Location of microphone 4D05414A NOTES 1 The operating sound is measured in anechoic chamber, if it is measured under the actual installation conditions, it is normally over the set value due to enviromental noise and sound reflection. 2 Measuring place: anechoic room Octave band center frequency (Hz) Location of microphone 840 Split Sky Air Outdoor Units

9 Sound data 9-2 Sound power spectrum Outdoor Units R-410A RMXS-E8V1B Sound power level (db) RMXS112EV Sound power level (db) RMXS140EV TW27607- NOTES Octave band center frequency (Hz) 1 dba = A-weighted sound power level (A-scale according to IEC) 2 Refernece acoustic intensity 0dB = 10E-6μW/m_ Measured according to ISO 744 TW27617- NOTES Octave band center frequency (Hz) 1 dba = A-weighted sound power level (A-scale according to IEC) 2 Refernece acoustic intensity 0dB = 10E-6μW/m_ Measured according to ISO 744 9 RMXS160EV Sound power level (db) TW27627- NOTES Octave band center frequency (Hz) 1 dba = A-weighted sound power level (A-scale according to IEC) 2 Refernece acoustic intensity 0dB = 10E-6μW/m_ Measured according to ISO 744 Split Sky Air Outdoor Units 841

10 Installation 10-1 Installation method Outdoor Units R-410A RMXS-E8V1B Required installation space The unit of the values is mm. 1. Where there is an obstacle on the suction side (a) No obstacle above 1 Stand-alone installation + Obstacle on the suction side only. (2) Where there is an obstacle on the discharge side (a) No obstacle above (1) Stand-alone installation (2) Series installation (2 or more) 500 or more 100 or more + Obstacle on both sides. 1000 or more (b) Obstacle above, too. 500 or less 100 or more 100 or more 100 or more 1 Stand-alone installation 1000 or more 10 2 Series installation (2 or more). + Obstacle on both sides 1000 or more 2 Series installation (2 or more). 500 or more 500 or less 200 or more 00 or more 1000 or more (b) Obstacle above, too. 500 or less 1000 or more 1000 or more 1 Stand-alone installation + Obstacle on the suction side,. 100 or more. Where there are obstacles on both suction and discharge sides: Pattern 1 + Obstacle on the suction side and both sides. 500 or less 1000 or more Where the obstacles on the discharge side is higher than the unit. (There is no height limit for obstructions on the intake side.) (a) No obstacle above. 1 Stand-alone installation. 150 or more 150 or more 150 or more 100 or more 500 or more 2 Series installation (2 or more). 2 Series installation (2 or more). + Obstacle on the suction side and both sides. 500 or less 1000 or more 1000 or more 00 or more 200 or more 00 or more 1000 or more 842 Split Sky Air Outdoor Units

10 Installation 10-1 Installation method Outdoor Units R-410A RMXS-E8V1B (b) Obstacle above, too 1 Stand-alone installation. The relations between H, A and L are as follows. L A 0<L 1/2 H 750 L H 1/2H<L H 1000 H < L Set the stand as:l<=h Close the bottom of the installation frame to prevent the discharged air from being bypassed. 2 Series installation (2 or more). The relations between H, A and L are as follows. L A 0<L 1/2 H 1000 L H 1/2H<L H 1250 H < L Set the stand as:l<=h Close the bottom of the installation frame to prevent the discharged air from being bypassed. Only two units can be installed for this series. Pattern 2 Where the obstacle on the discharge side is lower than the unit. (There is no height limit for obstructions on the intake side.) (a) No obstacle above. 1 Stand-alone installation. L H 2 Series installation (2 or more). The relations between H, A and L are as follows. L A 0<L 1/2 H 250 1/2H<L H 00 (b) Obstacle above, too. 1 Stand-alone installation. The relations between H, A and L are as follows. L A 0<L 1/2 H 100 L H 1/2H<L H 200 H < L Set the stand as:l<=h 500 or less 500 or less 1000 or more 1000 or more 100 or more 500 or more 1500 or more 500 or less 250 or more 00 or more 100 or more 1 Series installation. The relations between H, A and L are as follows. L A 0<L 1/2 H 250 L H 1/2H<L H 00 H < L Set the stand as:l<=h Close the bottom of the installation frame to prevent the discharged air from being bypassed. Only two units can be installed for this series. 4. Double-decker installation (a) Obstacle on the discharge side. Close the gap A (the gap between the upper and lower outdoor units) to prevent the discharged air from being bypassed. Do not stack more than two unit.. (b) Obstacle on the suction side only. Close the gap A (the gap between the upper and lower outdoor units) to prevent the discharged air from being bypassed. Do not stack more than one unit.. 5. Multiple rows of series installation (on the rooftop, etc.). (a) One row of stand-alone installation. (b) Rows of series installation (2 or more). 1000 or more 200 or more 500 or less 2000 or more 1500 or more 1000 or more 00 or more Drain piping construction dimension 100 or more 1000 or more Drain piping construction dimension 10 000 or more Close the bottom of the installation frame to prevent the discharged air from being bypassed. 1000 or more 1500 or more 600 or more The relations between H, A and L are as follows. L A 0<L 1/2 H 250 L H 1/2H<L H 00 H < L Cannot be installed D04976B Split Sky Air Outdoor Units 84

11 Operation range Outdoor Units R-410A RMXS-E8V1B RMXS-EV Cooling (50/60Hz) Heating Outdoor temp. ( CDB) Continuous operation Pull-down period Outdoor temp. ( CWB) Warming up period Continuous operation 11 Indoor temp. ( CWB) Indoor temp. ( CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length From outdoor unit to BP unit 5 m Total from BP unit to indoor unit m + Level difference 0 m + Air flow rate high D049096C 844 Split Sky Air Outdoor Units