Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Similar documents
Labkotec automatic warning devices for separators protecting the environment

Labkotec Level Instruments Protecting our environment

Labkotec Measurement Technology

SolarSET GSM SolarSET GSM with a Beacon

AND INSTALLATION MANUAL

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Oil/Sludge 12 VDC

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET-1000 (12 VDC)

LevelSET S GSM Functionalities Instructions for Commissioning and Use

SET Installation and Operating Instructions. Level switch for one sensor

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

SET-2000 Hi Level/Oil

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Labcom 200. Installation and User s Guide (230 VAC) Communication Unit

Alarm system For oil-water separator

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

14300 MAINS SEPARATOR ALARM MANUAL

SOLAR SEPARATOR ALARM

SCAN20 Series Gas Detection Controller

OilMatic Pro / 230 V AC

MANUAL Overflow sensor NVF-104/34-PF

G-TECTA TM. Portable Gas Detection Instruments

Dräger X-zone 5500 Area Monitoring

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

HYTEK ATEX APPROVED TANK ALARM

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Solar Separator Alarm Type Installation, Operation & Maintenance

Manual Power relay SR853

Dräger X-zone 5500 Multi-Gas Detection Device

Fire Signalling. Signalling Solutions

Snifter ATEX22 VERSION. User Manual. Distributor

Trident User s Manual

Labkotec Ice Detector

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

HYTEK ATEX APPROVED BUND ALARM

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Universal Tank Alarm Type Installation, Operation & Maintenance

Custom Engineered Design. English

ClampOn DSP Corrosion- Erosion Monitor

WATCHDOG Alarm Instruments. Safety for Industry and Building Technology

BOP Management System Information

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

RACK MONITORING SYSTEM RAMOS Ultra

Safety - a full time job

At Coster we manufacture a comprehensive range of pre confi gured modular controllers which are both easy to install and simple to programme by use

Quick Start Guide For the

Dräger Polytron 8310 Stationary gas detector (DSIR)

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

MANUAL Oil Level Sensor

Dräger Polytron 8000 Stationary gas detector (EC)

A2S s Company Profile

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

RAGNAR STÅLSKOG AB INSTRUCTION MANUAL HVDC-H HVDC-L VOLTAGE DETECTOR HVDC-H, HVDC-L 15H11

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Operating Instructions

Level gauges Series LS Level indicator, switch and transmitter for liquids

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

4) Intrinsic Safety Certification

SALES SUPPORT DOCUMENT

FIRElux Emergency Lighting

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Operating Instructions. For. Alarm Control Module. Model SSR 500

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Continuous, real-time detection, alarming and analysis of partial discharge events

Bristol Babcock Oil Content Monitor "oil in water"

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Dräger Polytron 7000 Fixed gas detector

Octalarm-T: the latest in future-proof industrial alarm diallers

Dräger X-am 7000 Multi-Gas Detection

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Healthy. Atmosphere. for Pigs and Poultry. for a

Affordable wireless monitoring without compromise

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

LC2200 Level Controller Installation and Maintenance Instructions

GasAlertMicroClip X3 Specifications

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Hazardous Area Zirconia Oxygen Systems

FOGMONITOR. Outsmart Your Grease Problem!

ClampOn DSP Pig Detector

Explosion-proof Immersion Heater Type D-8660

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Dräger REGARD -1 Control System

RACK MONITORING SYSTEM - RAMOS Ultra

Sensor Interface Module Installation/Operation Instructions

VIBRA-series: VIBRA, VIBRA +

Assembly. Host Sub-D Alarm

Mobrey MCU900 Series Universal Control Unit

APPLICATION DATA SHEET

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

distributing & controlling system solutions

Transcription:

Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe & fault monitoring systems in built Indicates when Separator needs emptying reduces waste management cost Remote monitoring capability Measure your success

Labkotec SET alarm devices for oil and grease separators Why does a separator require an alarm device? Today in all construction work, greater attention is paid to protecting the environment than ever before. separator systems now have a vital part in preventing environmental damage. spills into sewers and ground leaks are controlled better than they used to be, thanks to the increasing use of separator systems. Typical applications for the separator systems are petrol stations, airports, parking areas, highways and other places where the risk of an oil spill onto the ground is present. Separator systems preventing environmental damage are just part of the solution. How can you ensure they are still working years later and guarantee the benefits of investments made? How do you keep a check on the maintenance cost? The best safeguard against environmental damage is of course to use the separator system properly and service it periodically. Total reliability in the operation of the separator system can only be achieved when alarm devices are installed. Therefore it is possible to guarantee correct functioning of the separator year after year. By using Labkotec alarm devices: - The demands in terms of alarms in various standards and regulations are satisfied. - There is an immediate alarm if, for example, a serious oil spill occurs, and thus serious environmental catastrophes may be prevented. - The costs of routine servicing can be kept in check. The separator will be serviced only when the alarm indicates that the oil or sludge levels have been exceeded. - Separator leakage to the environment can be detected, if the water level drops below the sensing the alarm will activate. Labkotec alarm models are approved in accordance with the ATEX directive 94/9/EC and IECEx Labkotec offers the markets widest range of oil, sand and grease separator alarm systems. Special attention to the design of various models has improved reliability and performance, which benefits the world s environment. 2

separator alarm models and applications separator alarm device SET-1000 The SET-1000 level alarm instrument is specially designed for oil separators and grease traps. It indicates when it is time to empty the oil separator and thus prevents harmful hydrocarbon emissions to the sewer system. SET-1000 control unit and SET/DM3DL Cable joint SET/ DM3DL SET-1000 SandSET-1000 - Sludge alarm device for oil and sand separators The SandSET-1000 is a complete package to detect sand or sludge in the tanks. The SET/S2 gives alarm signal when there is sand or sludge between the ultrasonic sensing elements. The ultrasonic SET/S2 does not require any calibration, or any regular service. Just install the at the correct alarm level. SandSET-1000 control unit and SET/S2 Cable joint Sand/sludge SET/S2 SandSET-1000 LevelSET S Hi Level/ alarm device with two s The LevelSET S Hi Level/ is equipped with two s, one indicates the oil layer and the other indicates blockage detection. i.e. high level in case of sewer blockage or closure of the closing device. LevelSET S control unit, SET/DM3DL and SET/V s Junction box SET/V SET/ DM3DL LevelSET LevelSET S /Sludge alarm device with two s The LevelSET S /Sludge is equipped with two s, one indicates the oil layer and the other indicates when there is sand or sludge between the sensing elements of the SET/S2 ultrasonic. LevelSET S control unit, SET/DM3DL and SET/S2 s Junction box Sand/sludge SET/ DM3DL SET/S2 LevelSET 3

Inspection shaft oil alarm with the floating SET/OSK2 The SET/OSK2 indicates an oil layer in an inspection shaft, pump shaft or on a water basin. SET/OSK2 SET-1000 The SET/OSK2 floating oil SET-1000 control unit SET-1000 and SET/TSHS2 grease separator alarm The SET/TSHS2 s operating principle is capacitive and therefore it is an ideal choice for applications with greater amounts of solid grease than normal. Cable joint SET-1000 In alarm condition the SET-1000 will energize the internal buzzer and LED. For remote indication of the alarm condition the relay output facility can be utilized. SET-1000 control unit and SET/TSHS2 Grease SET/TSHS2 www.labkonet.com An intelligent Tank Sends out Emptying Requests The LabkoNet system can convey alarm information direct to the property's tank emptying service provider, enabling the separators to be emptied professionally, correctly and at the right time. The system also helps generate cost savings by eliminating unnecessary emptying events. Alarms The system's communication unit transmits the alarm from the tank to the servers either by GSM or another selected network. From the server the information is uploaded online and sent to the previously configured GSM subscriptions and e-mail addresses. Data is saved in a database, where it is accessible for later review for reporting purposes. The system enables easy proactive forecasting of the next emptying need. Saving in emptying events 24/7 monitoring Alarm data online, to mobile phones and e-mail The system is constantly monitored and a break in communications will cause an immediate alarm to be sent to the system supervisor. Alarm unit connected to LabkoNet server via data transfer unit SET alarm unit Labcom data transfer unit LabkoNet server LabkoNet web service LevelSET S GSM version connects the LabkoNet server directly LevelSET S GSM alarm unit LabkoNet server LabkoNet web service 4

LevelSET S oil separator alarm, Sludge and Hi Level alarms all in the same control unit New features Three digital s alarm system with integrated GSM modem New! The LevelSET S oil separator alarm control unit was developed to meet strict regulations and demands of various environmental agencies throughout Europe. LevelSET S is equipped with Fail-Safe alarm facility, giving total system monitoring of all sensor inputs. LevelSET S recognises when an oil or sludge space is full, or if there is a high level condition within the separator due to a blockage. Alarm conditions can be transmitted to mobile phones or computer systems via the integrated GSM modem or internal relays can be connected to remote beacons and audible alarms. An inbuilt LED and buzzer indicate the respective alarm condition locally. The GSM version of the LevelSET S can be programmed to alarm when the service inspection is due. The new digital technology within the sensors and the control unit significantly reduces the cabling cost. The three sensors were previously connected with six wires but now only two wires are required. Junction box SET/V Sand/sludge SET/ DM3DL SET/S2 LevelSET Labkotec s commitment to the design of high quality alarm systems for environmental monitoring of Separators assures a long service life for many years. New! New digital s The new generation of digital s are compatible with all existing control units. Contact Labkotec Sales if you require additional information regarding the selection of digital s. LevelSET S GSM version SET/DM3DL digital conductivity SET/S2 digital ultrasonic SET/V digital vibration SET/DM3DL oil interface is installed in the light liquid storage chamber at a specified level (refer to separators manufactures technical drawings). The alarms when the top section of the is in contact with oil. The is normally immersed in water. SET/S2 sludge alarm is installed in the lower section of the separator. The alarms when the sludge layer reaches the. The is normally immersed in water. SET/V high level is installed above the outlet s upper level. The alarms when in contact with liquid, oil or water. The is normally in air. 5

SolarSET for applications where mains supply is not available Various options as requirements demand: SET-1000 SandSET-1000 SET-2000 /Sludge SET-2000 Hi Level/ SolarSET applications: airports motorways car parks Separator alarm system The SolarSet alarm unit is a solar powered unit for monitoring the level of liquid hydrocarbon, sludge or high level in oil separators situated in locations where mains power is unavailable. Alarm conditions can be transmitted to mobile phones or computer systems via the GSM modem and locally with flashing beacon. Probe failures are also detected automatically. SolarSET contains alarm unit, battery, charge controller, solar panel and Labcom 200 communication unit or/and flashing beacon. SolarSET with GSM modem (with flashing beacon option) SolarSET with flashing beacon In case of an oil, sludge, hi level alarm or failure, SolarSET sends an alarm message as a text message (SMS) to the user s mobile phone or LabkoNet system. In case of an oil, sludge, hi level alarm or failure, SolarSET Beacon signals an alarm with a Xenon-beacon. The beacon will flash once every 5 seconds until the alarm ceases. 6

Technical Data Control units Dimensions Enclosure Ambient temperature Supply voltage Power consumption Probes Relay outputs Electrical safety Certificates: ATEX IECEx Ex-classification SET-100 SET-1000 LevelSET S 55 x 70 x 112 mm (L x H x D) Plastic housing IP 20, mounting on a 35 mm DIN rail 175 x 125 x 75 mm (L x H x D) IP 65, material polycarbonate, wall-mounted -20 C...+50 C -25 C...+50 C -30 C...+50 C 230 V AC ± 10 %, 50/60 Hz 230 V AC ± 10 %, 50/60 Hz, 110 V AC ± 10 %, 50/60 Hz, 12 VDC 2 VA 4,5 VA SET/...2 s One potential-free relay output, 250 V, 5 A, 100 VA EN 61010-1, CAT II, Class II VTT 02 ATEX 018X N/A Ex II (1) G [Ex ia] IIC One Labkotec SET Two potential-free relay outputs, 250 V, 5 A, 100 VA VTT 04 ATEX 031X IECEx VTT 10.0003X Ex II (1) G [Ex ia] IIC EN 61010-1, CAT II, Class II/III Max. three s Three potential-free relay outputs, 250 V, 5 A, 100 VA VTT 09 ATEX 027X Pending Ex II (1) G [Ex ia] IIB Probes Principle of operation IP classification Enclosure Ambient temperature Supply voltage Cable Certificates: ATEX IECEx Ex-classification SET/DM3DL Conductivity PVC, AISI 316, NBR, PA -30 C...+60 C VTT 09 ATEX 026X IECEx VTT 10.0001 Ex II 1 G Ex ia IIA T5 Ga SET/S2 SET/V SET/OSK2 SET/TSHS2 Ultrasonic Vibration Capacitive Capacitive IP 68 PA, PVC, aluminium, PA, PVC, aluminium, PVC, AISI 316 PVC, AISI 316 NBR NBR -30 C...+60 C -30 C...+60 C -25 C...+60 C -25 C...+60 C Approx. 12 VDC from SET control unit Fixed oil resistant PVC cable 3 x 0,5 mm, standard length 5 m VTT 09 ATEX 051X IECEx VTT 10.0002X VTT 09 ATEX 025X IECEx VTT 10.0006X Ex II 1 G Ex ia IIB T5 Ga VTT 03 ATEX 009X VTT 03 ATEX 024X N/A N/A Ex II 1 G Ex ia IIA T5 Ga Ex II 1 G Ex ia IIB T5 Ga Accessories Junction box Installation accessories Cable joint 7

Measure your success with Labkotec Labkotec Oy is a leading Finnish manufacturer and supplier of electronic level gauges, flow detection devices and alarms, automation and detector technology, and web-based data transmission solutions. We have more than 40 years of experience of the industry, and have pioneered several new solutions. Our diverse and comprehensive expertise enables us to supply solutions tailored to each customer s needs. Our ISO 9001:2000 and ISO 14001 compliant quality and environmental systems are certified by Lloyd's Register Quality Assurance. As regards to safety, we comply with the ATEX and ISPS standards. Labkotec Oy is a member of the international Indutrade Group. Our electronic level gauges and leak detection and flow measurement technologies cover a comprehensive range of applications. Our communication units and data transmission systems relay readings in real time, independently of permanent electrical or cable networks. Our automation and detector technology is widely used in access control systems in industrial installations, in storage silos and ports, as well as at snow dumping and landfill sites. Our TransControl system is based on RFID identification technology and fulfils the requirements of the International Ship and Port Security Facility (ISPS) code. Pictorino./Kirjapaino Hermes 7/2010 2.000 M15462_e www.labkotec.fi www.labkonet.com Labkotec Oy Myllyhaantie 6 FI-33960 Pirkkala FINLAND Tel. int. +358 (0)29 006 260 Fax int. +358 (0)29 006 1260 E-mail info@labkotec.fi Labkotec UK Ltd Shentonfield Road Manchester M22 4SD ENGLAND Tel.int. +44 (0)844 3350 477 Fax int. +44 (0)161 428 1179 E-mail info@labkotec.co.uk Labkotec AB Ekbacksvägen 28 SE-168 69 Bromma SWEDEN Tel. int. +46 (0)8 130 060 Fax int. +46 (0)8 555 36108 E-mail info@labkotec.se Labkotec Oy reserves the rights to alterations without prior notice. Due to policy of continuous improvement in R&D, technical specifications may change. Installation shall always be made as documented in manufacturer's instructions.