Comfort Compact Controller ZG 215VN

Similar documents
Comfort Compact Controller ZG 252N

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

ECL Comfort 110, application 116

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Self-learning Room Temperature Controller

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

Operating Instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Home and Building Control Home and Building Control Helping You Control Your World

prestige Control Application Supplement - TriMax

SCC1 GROZONE CLIMATE CONTROLLER The Simple One Series...

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Control solutions Biofloor

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

T834C Heating-Cooling Thermostat

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

prestige Control Application Supplement - ACVMax

TP970 Series CONVERTASTAT Kits

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

Control Application. Supplement - ACVMax

FIL-SPL Flow-through heater for central heating USER MANUAL

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

HEAT & COOL MODEL (REVERSE CYCLE)

Owner's Manual TABLE OF CONTENTS

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

- Data Brochure D 260. Boiler Control /09

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Modulating clock thermostat

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series

prestige Control Application Supplement - TriMax

CT1500, CT1501, CT1502, CT1503

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1

TCW 2000 Ice liner refrigerator and freezer PIJ

ECL Comfort 110, application 130

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Roth Touchline. German quality since User manual quick and easy guide 1/10

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

VEX100 series Air handling units with cross-flow heat exchanger

ROOM THERMOSTAT. with OpenTherm+ communication

AUTO CM CM USER GUIDE

G a

DAY/TIME Button: Selects hour, minute and day setting.

Roth Touchline. German quality since Quick and easy user manual 1/10

BrainQ RSC/2 USER MANUAL. BrainQ RSC/2 Thermostat 8G /10.05

Heating Controller SDC Remote Heating Controller DHC

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

TIREE FAN COIL CONTROLLER - T6580

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

WARNING Important Safety Information

TK-1801, TK-1811 TK-1801, TKR-1811

Weather compensated flow temperature control of heating and boiler systems

FUNCTION MANUAL, INSTALLATION GOLD RX/PX/CX/SD Generation F. Applicable to Program Version 1.27 and newer versions

DIAGNOSTIC GUIDE DAMP DRY TEST

Instruction manual. Remote control electric IR HEATER

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

KNX Multitouch Pro. Menu of the KNX Multitouch Pro User manual. This document describes how to operate the user interface of the KNX Multitouch Pro.

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

RT8220A-2 is a transmitter to be used with the RV8310D receiver/valve.

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

ECS-2M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

Portable Air Conditioner User Manual Read and save these instructions before use

ECS 5M USER S MANUAL ENVIRONMENT CONTROL SYSTEM

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

REA22 Room Temperature Controller

Auxiliary Fan Controller. Installation Instructions for Mazdaspeed 3

T7984 A,B,C Electronic Modulating Control Thermostats

Transcription:

Comfort Compact Controller ZG 215VN OPERATION AND PUTTING INTO SERVICE 1 2 3 4 5 6 7 B C ( ) /// B C ZG215VN auto1-8 0 P1 C B 8311.7151 P1 C B CB50268 L1 L2 S P1 C B A

Constant discharge temperature control TW V DR VM FT LF ZG 215VN ///// // /// CB2282 ZG Control Unit VM Servomotor DR Heating mixing valve LF Air flow sensor TW FT V Temperature selector (opt.) Frost protection thermostat Air heater

//// Constant flow temperature control for a floor heating system TW ZG 215VN // VF T //// P //// VM ZR CBZG107.cdr ZG Control Unit VM Servo motor ZR Heating mixing valve VF Flow sensor TW Temperature selector T Temperature limiter P Heating circuit pump

Operating the Control The ZG 215VN can be used at choice for the control of an air-handling system s constant discharge temperature (lefthand system diagram) or a floor heating s constant flow temperature (right-hand system diagram). The VF/LF temperature sensors monitor constantly the actual values and transmit these values to thezg control unit. Should the temperature or the supply temperature deviate from the target value, the controller commands the VM servo motor to adjust the ZR/DR mixing valve. The mixing valve performs the necessary change to the mixing ratio between the heated supply water and the heating circuit s returning cooled water. The TW temperature selector is used as remote control. By means of the P2 selector knob the flow or supply temperature can be mo - dified. The temperature selector is not absolutely necessary in functional terms, but it makes the operation easier. The FT frost protection thermostat (air-handling system only) works independently from the control unit and protects the air heater against freezing.

Operating and Display Components Pos. Function Basic Setting B Day mode C Reduced mode P1 Sensitivity 5 S Operating mode selector auto L1 Hotter LED (red) L2 Colder LED (green) 1 Instructions compartment 2 Heating curve diagram 3 Basic Settings 4 Reserve trip pins 5 Inserted trip pins 6 Timer (optional) 7 Pointer for the current time Settings on the Temperature Selector P2 Selector knob 0 S1 Party switch auto

Operating Mode Selector manu The control unit is deactivated (the timer runs). The mixing valve can be set manually (by hand). The pump is switched on. auto Recommended setting for higher energy saving: automatic change between day and reduced mode according to the timer with night switch-off. Only night mode, timer not active. Constant reduced mode according to the settings on the setting knobs B minus C, the timer remains inactive.

LED s L1 L2 Both LED s light up: neutral mixing valve stops only red LED lights up: hotter mixing valve opens only green LED lights up: colder mixing valve closes In the manu settings of the operating mode selector S there is no LED display.

Putting into service Set the timer 6 with the current time Set the operating mode selector S to auto The remaining basic factory settings are printed under 3 on the control unit. Timer for reduced mode 6 With the aid of the timer, the room temperature during idle periods can be reduced automatically to save on operating costs. The timer has a built-in power reserve of approx. 60 hours thanks to a rechargeable battery.

Changing the program Factory settings: red pin 6:00, blue pin 22:00. Pull out the trip pin and insert it again at the desired switch-on time. Push in the trip pins until they reach the stop! Owing to the different lengths, the trip pins must always be inserted in a red/blue alternate ordere. Thered trip pin switches on day mode, while the blue pin activates reduced mode. In order to make sure that the rooms are heated well in the morning, the heating system s day mode should be activated between a half an hour and an hour before using the rooms. Energy saving tip: Reduced mode can be activated up to an hour before the room is left. The storage capacity of the heating system and building is enough to keep the rooms warm for some time. Timer with day program The day program is repeated every 24 hours. If a (second) decrease in temperature is desired in the course of the day to save energy, the program needs to be extended. Take the extra trip pins 4 and insert them at the desired time. CB5044.7.cdr

Example: Desired time program Normal temperature: 6:00 h to 8:00 h and 16:00 h to 22:00 h Night decrease: 22:00 h to 6:00 h Day decrease: 8:00 h to 16:00 h Position of the trip pins red pin 6:00 h Start day mode (normal temperature) blue pin 8:00 h Start day decrease red pin 16:00 h Start day mode (normal temperature) blue pin 22:00 h Start night decrease Timer with week program The timer has a changeable dial. With the week program, dialling a different heating program for each weekday is possible. The dial is prepared ex factory for the day program and, if required, it can be changed to week program (see installation instructions). Setting the right time To set the time, the time dial is to be placed on the trip pins and turned clockwise until the indication on the setting marker 7 matches with the current time.

Optimization of the Settings The ZG 215VN control unit is a constant temperature controller. The desired temperature, e. g. the supply temperature of an air-handling system or the flow temperature of a heating system can be set on the setting knobs B and C of the controller. Day mode (setting knob B ) The selecting range on the setting knob B varies from 0 to 100 C. Normally the setting knob B sets the desired target value for day mode. If a temperature selector is used as a remote control, the setting knob B is to be set on 20. Reduced mode (setting knob C ) By means of setting knob C, the intensity of the decrease to be activated with the timer can be set. The setting range varies from 0 to -100 K ( C). The decrease set with setting knob C refers to the temperature either on setting knob B or on the TW. Example (without TW) Setting on the setting knob B 50 Setting on the setting knob C -20 i. e. for normal mode (day mode): constant target value of 50 C, for reduced mode (night) a target value of 30 C.

Example (with TW 23) Setting on the setting knob B 20 Setting on the TW 23 s selector knob P2 50 Setting on the setting knob C -20 Both settings give target values of 50 C in the day and of 30 C at night. Setting the target value Temperature selector TW 21A to 23A When using a temperature selector the setting knob B on the controller is always to be set on 20. The setting of the selector knob P2 on the TW is relevant for the target value. There are temperature selectors for various temperature ranges: TW 21A settable temperature range -15... + 15 C TW 22A settable temperature range 0 30 C TW 23A settable temperature range 20 70 C If no temperature selector is available, the desired target value is to be set on the setting knob B of the control unit Energy saving tip: Set the operating mode selector S on. The controller hence works constantly in reduced mode.

Remote Control TF 22 (optional) Setting the Room Temperature On setting knob P2 the setting of the room temperature can be fine tuned. The setting without the remote control is always 20 C. With the respective remote control another setvalue may be tuned. The scale on the selector is divided from -7 to +7 and corresponds more or less to the variation in degrees. + Increasing the Room Temperature Lowering the Room Temperature The values of the selector knob P2 and of the setting knob B on the control unit are added to the controllers basic setting of 20 C. With the controls TW 21A... TW 23A it is possible to set other control temperatures also. S1 P2

Examples TF 22 TW 23A Selector knob P2-1 0 +1 +2 20 21 22 23 Room temp. [ C] 19 20 21 22 20 21 22 23 If no temperature selector is available, the desired room temperature can be set only on the setting knob B of the control unit. Party switch S1 The party switch at the temperature controller has no function here.

Troubleshooting Checklist Is the heat generator at the required temperature? Read the heat generator s thermometer. Is the burner ready? Is the burner failure lamp on? If necessary, press the reset button. Was the temperature selector set by mistake? Setting of the selector knob P2 Check the setting of the control unit. Setting knobs B C and operating mode selector S. Is the timer running? Is the displayed time correct? Check the time and switch-on point. If the problem still has not been solved after checking the settings, position the setting knob B on +7 The servomotor should now open the mixing valve and the red LED L2 should light up. If this is not the case, the control system has failed. Contact your heating technician.

Manual mode CB5043.7.cdr

Manual mode (fig. on the left) In case of the breakdown of the heating mode regulation, you can proceed temporarily as follows: 1. Set the operating mode selector S on manu. 2. Open the mixing valve by hand until the desired flow and room temperatures are reached. The coupling incorporated in the mixing valve drive unit provides for the release of the connection between the motor and the mixing valve. Press firmly on the unlock key on the cover of the drive unit and keep the key pressed (firmly!). Use the setting lever to set the mixing valve in the desired position. After eliminating the problem, the mixing valve is set again to the right position by the control unit in automatic mode.

Behavior of the target values during day and reduced mode B Day mode setpoint /// B C C ( ) Reduced mode setpoint

Instructions for the Technician (only!) Removing the Timer (see also the installation instructions) Operating steps: 1. Pull out the instructions case. 2. Hold the timer by the two white stems and turn to the left until the connector is released. 3. Remove the timer. (To install the timer proceed in the opposite order.) Regulation Stability (Sensitivity) The stability of the regulation can be modified with the setting potentiometer P1. For the regulation technician: By means of P1, set the proportional range of the PD control unit. Recommended basic setting: P1 10. In case of unstable regulation set higher values.

Flow- and airflow-sensors VF20 VF 20A LF20

Reference Installation instructions Compact Control Units ZG 215N / 215VN / 252N EN1H-0181 GE51 Operating Instructions ZG 252N: EN2H-0215 GE51 ZG 215N: EN2H-0216 GE51 ZG 215VN: EN2H-0217 GE51 Informationsschrift (Planning broschure in German) L3 Komfort Compact Regler GE0H-0327 GE51

Centra Regelungstechnik Honeywell AG Böblinger Straße 17 D 71101 Schönaich Telefon +49 (70 31) 637-01 Telefax +49 (70 31) 637-493 Technical data may be changed without prior notice. http://www.honeywell.de/hga EN2H-0217 GE51 R0702 7157 560