Engineering Plan Views

Similar documents
RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RL with INNOVATOR II No Heat Doors

RM with INNOVATOR Doors

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

RLNIE with INNOVATOR II

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

LifeLine Premier RLNIE

RLT with INNOVATOR Doors

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

RMN with INNOVATOR Doors Technical Data Sheet

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

FG-L Technical Data Sheet

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _F NSF Certified June 2010

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

PWEE Technical Data Sheet

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Nosing Heater. Return Grill Heater

RL with INNOVATOR Doors

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

Installation & Service Manual

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

Installation & Service Manual

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

MD Medium Temperature Self Contained Open Vertical Merchandisers

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Reach-in Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

Medium Temperature Bulk Produce and Bakery Merchandisers

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

EcoVision Door Manual

Installation & Service Manual

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

BCH Medium Temperature Merchandisers

F-6 Multi-deck Frozen Food Wall Merchandisers

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

Ultra Low Front Rear Load Medium Temperature

Self-Contained MERCHANDISERS. February

CU0415, CU0715 and CU0920 Service Parts

Parallel Rack Systems

RFLNS, RFMNS & RFLTM Freedom Line

Installation & Service Manual

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Service Merchandisers

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

KR Electrical Defrost Unit Coolers (PN E108318_E)

SERIES NAV S Display Merchandisers

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

& MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION INDUSTRIAL COOLERS & FREEZERS WALK-IN COOLERS SERIES: EK, EM, EH, EI, EB, EF

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

Transcription:

LifeLine Premier RL with INNOVATOR Doors or INNOVATOR III Doors P/N 0520875_J NS Certified January 2018 OPTIONS SHOWN: Arch acade Dry Goods Storage Bump Out Partitions Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # an Assemblies, and Thermostats A. 12W Standard Energy Efficient an Assembly (1) 0477655 an Motor, Evaporator (MO.4410546) 0461805 an Blade (B.4780446) B. 0474033 Standard Non-adjustable Defrost (2) Thermostat (CT.4440726) C. Optional Adjustable Refrigeration Thermostat (3) D. 0344662 Defrost Limit Thermostat (4) (CT.4440261) E. 0461814 Relay Control Thermostat or (5) an and Anti-sweat Heater Thermostat (CT.4481296) (KG Only) Relays. 0342598 Anti-Sweat Control Relay (6) (120V) (RL.4480238) (KG Only) G. an Control Relay (7) 0342599 (208V) Electrical Defrost (RL.4480237) 0342598 (120V) KoolGas Defrost (RL.4480238) Item Part # Description Wiring Item # Heaters (Continued) I. Drain Pan Heater Electric & KoolGas (120V) (9) 0387036 (1) 2 Door Models (HE.4850239) 0387037 (1) 3 Door Models (HE.4850240) 0387038 (1) 4 Door Models (HE.4850241) 0387039 (1) 5 Door Models (HE.4850242) LED ixtures and Power Supply J. 0499399 Power Supply (EP.4481668) (10) K. Door Lamp, LED 050908300 4100K Center (BU.4441330) (11) 050908400 4100K End (BU.4441331) (11) (Note: A complete list of vertical LED replacement lamps can be found at Hussmann.com/TechnicalInfoAndParts) Heaters H. Electric Defrost Heaters ront (208V) (8) 3015372 (1) 2 Door Models (HE.4850346) 3015373 (1) 3 Door Models (HE.4850337) 3015374 (1) 4 Door Models (HE.4850347) 3015375 (1) 5 Door Models (HE.4850323) Electric Defrost Heaters Rear (208V) (8) 3015376 (1) 2 Door Models (HE.4850358) 3015377 (1) 3 Door Models (HE.4850359) 3015378 (1) 4 Door Models (HE.4850360) 3015379 (1) 5 Door Models (HE.4850361) Data sheet-lifeline RL Note: Revision J: Updated wiring diagrams on page 8 and 9. Refer to Innovator Reach-In Glass Door Installation and Service manual, P/N 0425683, for Innovator, Innovator II, or Innovator III door and frame replacement parts. 2018 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0527124

Engineering Plan Views Reach-In 2, 3, 4 & 5 Door LifeLine Premier RL - RM Plan View 05-2010 PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Dimensions shown as inches and (mm). 4 in. (102 mm) Minimum Air Gap from Merchandiser Insulated Panel to Wall or lat Surface Skid/ External Base Bottom ront Support Waste Outlet (see note *) Electrical Wireway Water Seal (see note **) Relay & Terminal Block Location ront 5-Door Shown (see note *) Door Swing Clearance Base 5-door merchandiser is shown above, without Bump Out, Dry Goods sections, Partitions or Ends. Illustrated below is a 4-door merchandiser with Dry Goods cabinets and Bump Out end partitions. Refer to chart on Page 3 for detailed dimensional information on options. LifeLine Premier Dry Goods \ Bump Out Plan View 2, 3 & 4 Door Dimensions shown as inches and (mm). 4 in. (102 mm) Minimum Air Gap from Merchandiser Insulated Panel to Wall or lat Surface Skid/ External Base Bottom ront Support Refrigeration Outlet Shelf Area Electrical Wireway Waste Outlet Splashguard Shelf Area Usable Width (see note *) Water Seal (see note **) ront 4-Door Shown Relay & Terminal Block Location Door Swing Clearance (see note *) from Bumper 2 of 10 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 LifeLine Premier RL with Innovator Doors or Innovator III Doors

Plan View Dimensions for LifeLine Premier Options LifeLine Premier RL With Innovator Doors or Innovator III Doors Abbreviations: DG = Dry Goods section BO = Bump Out General 2 Dr 3 Dr 4 Dr 5 Dr (A) Merchandiser Length 62 (1575) 92 1 /2 (2350) 122 7 /8 (3121) 153 3 /8 (3896) **NOTE: Each solid end adds approximately 2 3 /8 in (60 mm) to length of line up; each partition add approximately 2 3 /4 in (70 mm); case to case joints can add approximately 1 /8 in (3 mm) for gasket material. (A) Merchandiser Length BO includes 2 bump-out ends 66 (1676) 96 1 /2 (2451) 126 7 /8 (3222) 157 3 /8 (3997) (A) Merchandiser Length DG includes 4 ends and dry goods cabinets 92 1 /2 (2350) 123 (3124) 153 3 /8 (3896) NA Maximum O/S dimension of merchandiser back to front *** 43 3 /4 (1111) 43 3 /4 (1111) 43 3 /4 (1111) 43 3 /4 (1111) Maximum O/S dimension of merchandiser back to front BO *** 55 3 /4 (1416) 55 3 /4 (1416) 55 3 /4 (1416) 55 3 /4 (1416) *** Includes bumper. Add 26 1 /2 in. (673 mm) for door swing. Interior width of dry goods cabinet 10 3 /4 (273) 10 3 /4 (273) 10 3 /4 (273) NA Interior depth of dry goods cabinet 12 7 /8 (327) 12 7 /8 (327) 12 7 /8 (327) NA Back of merchandiser to rear of splashguard 39 7 /8 (1013) 39 7 /8 (1013) 39 7 /8 (1013) 39 7 /8 (1013) Back of merchandiser to rear of splashguard BO 51 7 /8 (1318) 51 7 /8 (1318) 51 7 /8 (1318) 51 7 /8 (1318) Width of Skid rail 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) Width of Bottom ront Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front support and splashguard 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) Electrical Service (B) RH end of merchandiser to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102) (B) RH end of merchandiser to the center of nearest knockout BO 6 (152) 6 (152) 6 (152) 6 (152) (B) RH end of merchandiser to the center of nearest knockout DG 19 1 /4 (489) 19 1 /4 (489) 19 1 /4 (489) NA RH end of merchandiser to the center of LH knockout 58 (1473) 88 1 /2 (2248) 118 7 /8 (3019) 149 3 /8 (3794) Back O/S of merchandiser with bump-out to center of knockout 53 5 /8 (1362) 53 5 /8 (1362) 53 5 /8 (1362) 53 5 /8 (1362) * NOTE: Electrical ield Wiring Connection Point is at terminal. Waste Outlet (C) Right end of merchandiser to center of waste outlet 23 7 /8 (606) 54 1 /4 (1378) 46 1 /4 (1175) 76 5 /8 (1946) (C) Right end of merchandiser to center of waste outlet BO 25 7 /8 (657) 56 1 /4 (1429) 48 1 /4 (1226) 78 5 /8 (1997) (C) Right end of merchandiser to center of waste outlet DG 39 (991) 69 1 /2 (1765) 61 1 /2 (1562) NA Back O/S of merchandiser with bump-out to center of waste outlet 46 7 /8 (1184) 46 5 /8 (1184) 46 5 /8 (1184) 46 5 /8 (1184) Water Seal Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) ** NOTE: ield installed water seal outlets, tees, and connectors are shipped with merchandiser. Refrigeration Outlet (D) RH end of merchandiser to center of RH refrigeration outlet 5 3 /8 (136) 5 3 /8 (136) 5 3 /8 (136) 5 3 /8 (136) (D) RH end of merchandiser to center of RH refrigeration outlet BO 7 3 /8 (187) 7 3 /8 (187) 7 3 /8 (187) 7 3 /8 (187) (D) RH end of merchandiser to center of RH refrigeration outlet DG 20 5 /8 (524) 20 5 /8 (524) 20 5 /8 (524) NA Back O/S of merchandiser with bump-out to center of refrigeration outlet 44 (1118) 44 (1118) 44 (1118) 44 (1118) Outside bottom front supports from end of merchandiser 7 (178) 7 (178) 7 (178) 7 (178) Outside bottom front supports from end of merchandiser BO 9 (229) 9 (229) 9 (229) 9 (229) Outside bottom front supports from end of merchandiser DG 26 1 /2 (673) 26 3 /4 (679) RH 26 1 /4 (667) NA 37 1 /2 (952) LH Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610) Center bottom front support from Centerline BO 24 (610) 24 (610) 24 (610) 24 (610) Center bottom front support from Centerline DG 6 3 /4 (171) LH 8 3 /4 (222) RH 24 (610) NA Distance between Center and Outside supports will vary. P/N 0520875_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 10

LifeLine Premier RL With Innovator Doors or Innovator III Doors acade (Installed Position) acade (Installed Position) acade (Shipping Position) acade (Shipping Position) Installed Installed Shipped Shipped 12 in. Straight acade acade Options in Cross Section 12 in. Arch acade acade (Installed Position) acade (Shipping Position) Installed acade (Installed Position) acade (Shipping Position) Installed Shipped Shipped 18 in. Straight acade 18 in. Arch acade acade Lamp Maximum Stocking Height Usable Height Usable Depth Adjustable Shelves ixed Shelf Bump Out Electrical Connection for Shelf Lamps Dry Goods Cross-Section Partition and End Profiles 4 of 10 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 LifeLine Premier RL with Innovator Doors or Innovator III Doors

LifeLine Premier Reach-in 2, 3, 4 and 5 Door Models Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. LifeLine Premier RL With Innovator Doors or Innovator III Doors Standard Reach-in configuration consists of Innovator I doors, energy efficient fan motors, and EcoShine II LED vertical lighting. LifeLine Premier RL - RM Dimensions shown as inches and (mm). 18 in. Arch acade Shown acade (Installed Position) acade (Shipping Position) 4 in. (102 mm) Required Air Gap See Page 4 for alternate facade heights. Shipped Installed RERIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 and 55% R.H. IC AHRI Rating* Discharge Air ( ) 5 12 2 Evaporator ( ) 11 19 7 Unit Sizing ( ) 14 22 10 *With door A/S controller Btu/hr/Door Innovator Parallel 955 1065 910 Conventional 970 1085 940 Innovator III Parallel 935 1035 Conventional 955 1055 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. rame Door Electrical ield Wiring Connection is at Terminal Electrical Stub-up Area Shelf Refrigeration Outlet an Coil Estimated Charge *** RL 2Dr 1.8 lb 29 oz 0.8 kg 3Dr 2.7 lb 43 oz 1.2 kg 4Dr 3.6 lb 58 oz 1.6 kg 5Dr 4.6 lb 74 oz 2.1 kg Bump Out ***This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg). NS Certification This merchandiser model is manufactured to meet NS/ANSI (National Sanitation oundation) Standard #7 requirements for construction, materials & cleanability. DEROST DATA IC requency (hr) 24 24 Defrost Water (lb/dr/day) 1.2 1.2 (± 15% based on case configuration and product loading.) Electric IC Temp Term ( ) 48 48 ailsafe (minutes) 45 45 Gas Duration (minutes) 20 20 Offtime Not Recommended CONVENTIONAL CONTROLS Low Pressure Backup Control IC CI/CO (Temp )** 18 / 34 26 / 45 Indoor Unit Only, Pressure Defrost Termination (Temp )** Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. Anti-sweat controls are standard for all low temperature Reach-in cases with Innovator I doors. P/N 0520875_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 10

LifeLine Premier RL With Innovator Doors or Innovator III Doors Hussmann recommends against frame heater cycling with Innovator doors or Innovator III doors to prevent door seals from freezing to the frames and tearing. Electrical Data 2Dr 3Dr 4Dr 5Dr Number of ans 12W 2 3 4 5 Amperes Watts Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Energy Efficient Evaporator an 120V 50/60Hz 0.60 0.90 1.20 1.50 36 54 72 90 240V 50/60Hz Export Innovator 0.30 0.45 0.60 0.75 36 54 72 90 Door Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Innovator* 1.5 2.3 3.0 3.8 182 273 364 455 120V 50/60Hz Innovator III 0.9 1.3 1.7 2.2 104 156 208 260 240V 50/60Hz Export Innovator 0.8 1.2 1.5 1.9 183 275 367 459 220V 50/60Hz Export Innovator III NA NA NA NA NA NA NA NA * Maximum door watts without anti-sweat cycling controls shown. rame Anti-sweat Heaters (on fan circuit) 120V 50/60Hz 0.78 1.18 1.57 1.97 94 141 188 236 240V 50/60Hz Export 0.45 0.67 0.89 1.12 107 161 215 269 Minimum an Circuit Ampacity 120V 50/60Hz Innovator 3.1 4.9 6.8 8.6 120V 50/60Hz Innovator III 2.5 3.9 5.5 7.0 240V 50/60Hz Export Innovator 1.8 2.9 4.0 4.9 240V 50/60Hz Export Innovator III 1.0 1.6 2.3 2.8 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 240V 15 15 15 15 Defrost Drain Heaters (120V) 0.63 1.25 2.00 2.57 75 150 240 300 (Export: 220V 50 Hz) 0.34 0.76 1.22 1.53 84 168 269 336 (Export: 240V 50 Hz) 0.41 0.83 1.33 1.67 100 200 320 400 208V 1Ø Electric Defrost 6.72 10.08 13.46 16.82 1400 2100 2800 3500 (Export: 220V 50 Hz) 7.11 10.66 14.24 17.79 1564 2345 3133 3914 (Export: 240V 50 Hz) 7.76 11.65 15.53 19.42 1864 2796 3728 4660 Standard Vertical LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Hussmann EcoShine II - A (120V) 0.31 0.46 0.62 0.77 37.1 55.6 74.2 92.7 Hussmann EcoShine II - A (220V Export) 0.17 0.25 0.34 0.42 37.1 55.6 74.2 92.7 Optional Vertical LED Lighting Hussmann EcoShine II - B (120V) 0.36 0.52 0.68 0.84 43.2 62.3 81.4 100.5 Hussmann EcoShine II - B (220V Export) 0.20 0.28 0.37 0.46 43.2 62.3 81.4 100.5 Anti-sweat controls are standard for all low temperature Reach-in cases with Innovator I doors. * Dry Goods sections are not available on 5-Door models. 6 of 10 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 LifeLine Premier RL with Innovator Doors or Innovator III Doors

LifeLine Premier RL With Innovator Doors or Innovator III Doors Product Data (Refrigerated Area Only) Recommended Usable Cube 1 (Cu t/dr) AHRI Total Display Area 2 (Sq t/dr) Shelf Area 3 (Sq t/dr) 23.46 ft 3 /Dr (0.66 m 3 /Dr) 13.04 ft 2 /Dr (1.21 m 2 /Dr) 29.32 ft 2 /Dr (2.72 m 2 /Dr) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves. Product Data (Dry Goods Area Only) TOTAL Gross Usable Cube (Volume for 2 DG per merchandiser) 10.33 ft 3 / (0.29 m 3 ) ESTIMATED SHIPPING WEIGHT 4 Standard LifeLine Premier Merchandiser (12-Inch acade, no Arch) 2 Dr 3 Dr 4 Dr 5 Dr Solid End (each) lb (kg) 1027 (466) 1340 (608) 1655 (751) 1949 (884) 70 (32) Standard LifeLine Premier Merchandiser (18-Inch acade, no Arch) lb (kg) 1037 (470) 1355 (615) 1675 (760) 1974 (985) 75 (36) LifeLine Premier Merchandiser with Two (2) Bump Out Partitions (12-Inch acade, no Arch) lb (kg) 1206 (547) 1519 (689) 1834 (832) 2128 (965) N/A LifeLine Premier Merchandiser with Two (2) Bump Out Partitions (18-Inch acade, no Arch) lb (kg) 1229 (557) 1547 (702) 1867 (847) 2166 (982) N/A LifeLine Premier Merchandiser with Two (2) Dry Goods Sections, our (4) Partitions (12-Inch acade, no Arch) lb (kg) 1507 (684) 1820 (826) 2135 (968) NA NA LifeLine Premier Merchandiser with Two (2) Dry Goods Sections, our (4) Partitions (18-Inch acade, no Arch) lb (kg) 1537 (697) 1855 (841) 2175 (987) NA NA LifeLine Premier Merchandiser with Two (2) Bump Out Partitions, Two (2) Dry Goods Sections, Two (2) Partitions (12-Inch acade, no Arch) lb (kg) 1546 (701) 1859 (843) 2174 (986) NA N/A LifeLine Premier Merchandiser with Two (2) Bump Out Partitions, Two (2) Dry Goods Sections, Two (2) Partitions (18-Inch acade, no Arch) lb (kg) 1579 (716) 1897 (860) 2217 (1006) NA N/A Add 10 lb (5 kg) for Arch 4 Actual weights will vary according to optional kits included. P/N 0520875_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 10

an and Heater Circuits - Electric Defrost (standard) CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black LB = Light Blue BR = Brown Y = Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) 208 V 208 V 1 2 3 ANS 120 V 14 REAR DEROST RONT DEROST AN RELAY NC COM NO AN RELAY COIL 8 7 6 ANS 16 LINE NEUTRAL 7 8 7 DEROST LIMIT O.O.R. ROD HEATER (DRAIN) 9 1 4 4 5 ANS NEUTRAL 26 25 24 CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the individual merchandiser s defrost circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240. Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. 13 HEATER RAME A.S. 22 NEUTRAL DOOR A.S. 12 21 LIGHTS (120 V) LIGHTS (NEUTRAL) 17 SWITCH LIGHTS L 20 3024448_C IELD WI DEROST TERMINATION THERMOSTAT C.O.R. THE HEAVY LINES DRAWN INSIDE THE TERMINAL BLOCKS REPRESENT PERMANENT INTERNAL JUMPERS. 1 2 3 4 5 6 7 8 10 11 12 13 14 16 17 20 21 22 24 25 26 DEROST HEATERS (208V) DEROST HEATERS (208V) ANS & A/S (120V) LIGHTS (120V) LIGHTS (NEUTRAL) ANS, & A.S (NEUTRAL) THE HEAVY LINES DRAWN OUTSIDE THE TERMINAL BLOCKS REPRESENT REMOVABLE EXTERNAL JUMPERS. Electric Defrost Sequence - 1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator an Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater. 2. If the Defrost Heater raises internal air temperature above 90, the Defrost Limit Thermostat (4) will open. 3. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator an Relay Coil Circuits. The Drain Pan Heater goes off and fans are on. 4. Standard low temperature Reach In cases with Innovator I doors are shipped with the controller for door antisweat heater control installed. Do not connect the controller input to a centralized anti-sweat system. It must be connected to a continuous 120V circuit for proper operation. 5. If the case is connected to a centralized anti-sweat controller that meets DOE compliance requirements, the controller is not installed on the case. eed the 120V controller output into terminal #12. 6. Options may be installed that have additional or replacement wiring diagrams. 7. Reach In cases with Innovator III doors do not have the controller. 8 of 10 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 LifeLine Premier RL with Innovator Doors or Innovator III Doors

an and Heater Circuits - Gas Defrost (optional) CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black LB = Light Blue BR = Brown Y = Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) 120V 14 16 COM AN RELAY NC NO 6 1 RELAY CONTROL C.O.R. DEROST LIMIT O.O.R. ANS ROD HEATER (DRAIN) 5 6 AN RELAY COIL NEUTRAL 26 25 24 Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. LINE NEUTRAL 13 RAME A.S. 22 HEATER NEUTRAL 12 DOOR A.S. 21 120V 17 SWITCH LIGHTS L NEUTRAL 20 10 11 12 13 14 16 17 20 21 22 24 25 26 ANS & A.S. (120V) Gas Defrost Sequence - LIGHTS (120V) LIGHTS (NEUTRAL) ANS & A.S. (NEUTRAL) THE HEAVY LINES DRAWN INSIDE THE TERMINAL BLOCKS REPRESENT PERMANENT INTERNAL JUMPERS. THE HEAVY LINES DRAWN OUTSIDE THE TERMINAL BLOCKS REPRESENT REMOVABLE EXTERNAL JUMPERS. 3024767_C 1. Defrost vapor enters evaporator causing a rise in temperature. At about 35 the Control Relay Thermostat (5) closes the an Relay Coil (7) and Control Relay Coil (6) circuit. The Coil opens the an, Door Heater, and rame Heater circuits, while energizing the Drain Pan Heater (9). 2. If the Drain Pan Heater (9) raises internal air temperature above 90, the Heater Limit Thermostat (4) will open. 3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20, the Control Relay Thermostat will open, de-energizing the Control Relay Coil and an Relay Coil (7). Control and an Relay s will open the Drain Pan Heater circuits, and will close the an, Door Heater, and rame Heater circuits. 4. Standard low temperature Reach In cases with Innovator I doors are shipped with the controller for door antisweat heater control installed. Do not connect the controller input to a centralized anti-sweat system. It must be connected to a continuous 120V circuit for proper operation. 5. If the case is connected to a centralized anti-sweat controller that meets DOE compliance requirements, the controller is not installed on the case. eed the 120V controller output into terminal #12. 6. Options may be installed that have additional or replacement wiring diagrams. 7. Reach In cases with Innovator III doors do not have the controller. P/N 0520875_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 9 of 10

Standard Vertical Lighting Hussmann EcoShine LED ixtures LIGHT SWITCH INPUT WIREWAY BLUE OUTPUT 2 DOOR LED LIGHT WIRING DIAGRAM TERMINAL BLOCK LIGHT SWITCH WIREWAY INPUT OUTPUT BLUE TERMINAL BLOCK 3 DOOR LED LIGHT WIRING DIAGRAM LIGHT SWITCH LIGHT SWITCH INPUT OUTPUT BLUE 4 DOOR LED LIGHT WIRING DIAGRAM TERMINAL BLOCK WIREWAY WIREWAY INPUT OUTPUT BLUE TERMINAL BLOCK 5 DOOR LED LIGHT WIRING DIAGRAM WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled numbers = Parts List Item Numbers R= Red Y = Yellow G = Green BL = Blue BK = Black W = White = 120V Power = 120V Neutral = ield Ground = Case Ground 10 of 10 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 LifeLine Premier RL with Innovator Doors or Innovator III Doors