TopMaster Air Handling Unit

Similar documents
TopMaster Air Handling unit. Technical data

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

TopMaster Air Handling unit. Installation instructions

VERSO Air Handling Units

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Unit heater with accessories

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

VERSO Air Handling Units

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

iq Star LYRA II chilled beam cassette

COMPACT Air & Heat. Contents

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

recooler HP EQKR HEAT PUMP

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

ClimaFläkt. Chillers and condensing units

GOLDTM. Air Handling Units with Built-in Control Equipment that offer Economical Operation.

CHILLED BEAM CASSETTE IQ STAR LYRA

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

The New Sorption Rotary Heat Exchanger

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

EU Air Handling Units with SEMCO EXCLU-SIEVE

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

GOLD RX, GOLD RX 12 GOLD RX,

Series VENTS VUT R WH ЕС

TECHNICAL SPECIFICATION

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

Supply air unit VEKA Installation & Maintenance

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Topvex SF02-SF12 Air Handling Unit

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Smoke extract fan SMHA HATCH

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

iq Star LYRA II chilled beam cassette

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Heat Recovery Unit HERU. web-version

Heat recovery unit RDKS

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

CHAPTER 6 CONDENSING UNITS

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

UNITES TERMINALES ET MINI CTA FIDJI

CLIMASTER ZCF AIR HANDLING UNITS

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Complements and Accessories

Primo Hotel. General. Indoor climate units for hotel rooms

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

eco TOP INSTALLATION AND MAINTENANCE MANUAL

GLEB Kitchen exhaust fan

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

VEX100 series Air handling units with cross-flow heat exchanger

PRODUCT GUIDE

Climatix Basic reference addresses for eq Fläkt application v1.x

ROOFMASTER STEF-HT ROOF FAN

Technical Information. Ventilation

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

GOLD AIR HANDLING SYSTEM OVERVIEW

Swegon CASA. duct coils for heating. the supply air

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Description of the functions, IQlogic

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Bevent Rasch RABC-VAV. - Fire /03/2018

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Smoke Master SMPA Compact pressurisation system

VEX250H with rotary heat exchanger and EXact control system

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

HOTEL CHILLED BEAM IQ STAR SILENCIA

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Ventilation Solutions Product Range > Box Fans

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

PGDX Rectangular duct coolers with DX coil

Shunt groups and protection against freeze damage

PARASOL EX. Suspended comfort modules QUICK FACTS

C-series Controllers for air handling systems

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Transcription:

TopMaster Air Handling Unit

Contents Page Contents......................................2 Unit description................................3 Design........................................4 Technical Details Size 030....................................5 Size 050....................................6 Accessories....................................7 Controls......................................9 Control functions..............................10 Product Codes................................12 Fläkt Woods 8180 GB 2012.10 2 Specifications are subject to alteration without notice

Unit Description Top Master is a compact unit in two sizesthat requires minimal space. Compact dimensions and low sound data provide great flexibility in the location of the unit. Its attractive design also adds to the flexibility of location. All duct connections are on top of the unit. The unit is supplied with direct driven supply and extract fans, supply and exhaust filters as well as a rotating heat recovery unit. The control system, which is integrated in the unit, is equipped for a large number of external functions. Typical installations The TopMaster has a wide range of applications and can be installed in most buildings that require ventilation, such as schools, offices, conferencepremises, shops etc. Product data Air flow range 100-550 l/s (size 030, 100-350 l/s) (size 050, 100-550 l/s) Effective heat recovery Integrated control system Integrated re-heater Simple installation with all connections upwards Attractive design Externally painted Quality and Environment All units and components from Fläkt Woods are designed, tested and built to the applicable standards including quality assurance system ISO 9001 and Environmental management system ISO 14001. Environmental declaration Substance Propor- Recyclable To tion material landfill Metals 92% X Polymers 2.5% X X Mineral wool insulation 5% X Others 0.5% X Fläkt Woods 8180 GB 2012.10 Specifications are subject to alteration without notice

Unit Description - design Casing The unit is made of galvanized sheet steel and the outside is painted white. The casing is insulated with 25 mm of mineral wool. Inspection doors for fans, filter and rotor have handles and locks. The unit is supplied on a stable base which can be fitted with feet. Corrosion class C3 Seal CEN class L3 (CEN class A) Fan We chose the fan for TopMaster to give you top performance and overall economy combined with low noise levels. The fan is a single inlet radial fan with forward curved blades. It is driven by a DC motor with integrated electronics, which establishes a constant flow in the unit within the work area. The desired flow is controlled by the unit s control system. Components in the casing Filter Supply and extract filters made of fibreglass. Filter class F5 on the extract side and F7 on the supply side. The filters are pressed against the sealing strip in the casing. Integrated heater Heater battery for hot water or electricity are built-into the unit. The desired supply temperature is controllled by the unit s control system. Rotary heat exchanger The rotor is made of non-hygroscopic aluminium equipped with purging sector and rotation monitor. During normal comfort ventilation there is no need for defrosting. When relative humidity in the extract exceeds 30% and the outdoor temperature is lower than 15 C there is a risk of freezing. Check the need for defrosting with Fläkt Woods AB. Water heater The heater for water heating is made of copper pipes and aluminium fins. Pipe connection Ø15. Frost protection sensor is included in the control equipment. Max. operating pressure 1.6 MPa. Electric heater Electric heater with integrated control equipment for power control. Heater element in stainless steel. The heater is equipped with 2 thermal overload protection devices, one with automatic and one with manual reset. Fläkt Woods 8180 GB 2012.10 Specifications are subject to alteration without notice

,, p q p q q p p q p Filter Rotor Fläkt Filter Fläkt p q p q q p p q p Filter Rotor Fläkt Filter Fläkt TopMaster Air handling unit Technical Details, size 030 System overview The diagram shows the accessible external pressure drop for the duct system and external function components. The weighted noise levels given in db(a) apply to ducts on the fan s outlet side. The SFPv values for the respective fans are calculated according to the Svensk Ventilation (SwedishAssociation of Air Handling Industries) V document 1995:1 (rev. 2000), that is, clean filters, and reference taken of leakage and cleaning flow and any additional pressure drop for correct pressure balance. Readings for the respective fans are totalled to give the SFPv value for the entire unit. Dimensions, weights and electrical data Direct driven radial fan with forward curved blades. Motor, IP54. Power electric heater 2.4 kw. Rotor: Temperature efficiency 80% at 0.3 m 3 /s. Mains connection: 3x400V, 50Hz (Units with a water heater can be connected to 1x230V) External fuse protection: max 10 A, max 4 mm 2. The mains supply cable must be fitted with an external switch-disconnector, which can interrupt the current to the whole unit. Ambient temperature during operation 0...40 C Weight: 170 kg Filter: Supply : 670 x 300 x 50 mm, F7 Extract : 670 x 300 x 50 mm, F5 Ø 250x4 p e external P a, Pa p e external P a, Pa 700 600 500 400 300 200 100 1.5 1.25 LwA,dB 70 SFPv m 3 /s 50 0.1 0.2 0.3 0.4 q v 400 500 600 700 800 900 1000 1100 1200 1300 1400 m 3 /h 700 600 500 400 300 200 100 TopMaster 00 supply 1.5 1.25 1 1 0.75 TopMaster 00 extract 0.75 SFPv 60 75 65 m 3 /s LwA,dB 55 50 0.1 0.2 0.3 0.4 q v 400 500 600 700 800 900 1000 1100 1200 1300 1400 m 3 /h 45 1050 170 327 286 327 246 185 Extract Exhaust Fresh Supply 235 735 100 50 12 310 1280 735 Ø 15 Supply Exhaust Right-hand version 140 35 50 Fresh Extract Fläkt Woods 8180 GB 2012.10 5 Specifications are subject to alteration without notice

p q p q q p p q p Filter Rotor Fläkt Filter Fläkt p q p q q p p q p Filter Rotor Fläkt Filter Fläkt TopMaster Air handling unit Technical Details, size 050 System overview The diagram shows the accessible external pressure drop for the duct system and external function components. The weighted noise levels given in db(a) apply to ducts on the fan s outlet side. The SFPv values for the respective fans are calculated according to the Svensk Ventilation (SwedishAssociation of Air Handling Industries) V document 1995:1 (rev. 2000), that is, clean filters, and reference taken of leakage and cleaning flow and any additional pressure drop for correct pressure balance. Readings for the respective fans are totalled to give the SFPv value for the entire unit. Dimensions, weights and electrical data Direct driven radial fan with forward curved blades. Motor, IP54. Power electric heater 4.7 kw. Rotor: Temperature efficiency 70% at 0.5 m 3 /s. Mains connection: 3x400V, 50Hz (Units with a water heater can be connected to 1x230V) External fuse protection: max 16 A, max 4 mm 2. The mains supply cable must be fitted with an external switch-disconnector, which can interrupt the current to the whole unit. Ambient temperature during operation 0...40 C Weight: 175 kg Filter: Supply : 670 x 300 x 100 mm, F7 Extract : 670 x 300 x 50 mm, F5 p external, Pa TopMaster 050 supply TopMaster 050 extract Ø 250x4 p external, Pa 1050 45 170 327 286 327 246 100 185 Extract Exhaust Fresh Supply 235 735 50 1280 735 Ø 15 12 310 140 Supply Exhaust Right-hand version 35 50 Fresh Extract Fläkt Woods 8180 GB 2012.10 Specifications are subject to alteration without notice

Accessories Air cooler, water, for duct mounting, RDNN Air cooler for cold water, copper pipes and aluminium fins. The cooler is built into a hot dip galvanized sheet steel casing with 9 mm insulation. The casing has a removable hatch for cleaning and duct connections with rubber ring seals. The cooler is installed so that the distance to the fan or bend before the cooler is at least 600 mm. The cooler is only available in a left-hand version. Bleeding and draining is carried out via the pipe system. The pipe connection, positioned on the outlet end, is flat and intended for clamp connection. The drainage trough is made of stainless steel, connection R 1/2. Max. operating pressure 1.0 Mpa. Max. operating temperature 100 C Duct silencer, RDLD The silencer is a straight circular duct silencer with 100 mm rock wool filling. The duct connections are fitted with rubber ring seals. The silencer consists of a perforated pipe surrounded by a mantel and ends made of hot dip galvanized sheet steel. The area between is filled with rock wool which is covered by a fibre sheet to prevent the fibres from loosening. Fire class EI30. Connection straight section 300 mm from fan outlet. 900 Ø250 Ø50 Ø15 50 0 Water trap RDTZ-08 Compact water seal for connecting the cooler. Shut off damper for duct mounting RDVA Damper for duct mounting. Seal class 3 (CEN 3) The damper is made of hot dip galvanized sheet steel and fitted with an on/off actuator with spring return. The damper actuator is connected to the electrical cabinet via a quick connector. The damper has a duct connection with a rubber ring seal and can be mounted directly to the unit or in the duct. The design is suitable for duct insulation of up to 50 mm. The sound power level while completely open is below 20 db at speeds below 10 m/s. 8 Adjustable feet, RDTZ-0 The unit can be positioned directlyonthefoundationifitis flat and horizontal. Adjustable feet can be used for adjustment. Adjustable foot 15-85 mm. Arubber pad is included in the kit. Spare filter, RDTZ-0 Akit with a spare filter for one passage. F5 or F7. Flexible connection, RDTZ-05 Flexible connection made of fibreglass sheet for flexible connection of ducts. Pressure gauge, flow measurement RDTZ-0 Pressure gauge for measuring flow, can be installed on the end of the unit and connected to nipples. Supplied separately. Ø250 Pressure gauge, U pipe for filter RDTZ-0 Single pressure gauge for measuring filter pressure drop, can be installed on the end of the unit and connected to nipples. Supplied separately. Fläkt Woods 8180 GB 2012.10 Specifications are subject to alteration without notice

Accessories Dual-purpose cowl RDTZ-09 External wall cover for outdoor and extract, for wall mounting. This prevents leakage between the two flows. The cover is made of black plastic-coated sheet metal and consists of a wall plate, wall cover, front panel. The front panel is detachable and can be turned over. TopMaster 050 A E B TopMaster 00 ød ød C ød ød B F G Product code A B C D E Weight,kg RDTZ-09-050-1 80 0 150 15 15 10 C A E Pressure drop, TopMaster 050 Product code A B C D E F G Weight,kg RDTZ-09-00-1 50 0 250 190 15 90,5 Pressure drop, TopMaster 00 Tryckfall, Pressure Pa drop, Pa 125 100 75 50 25 Kombihuv Dual-purpose RDTZ-09-030-1 cowl Kanaldimension Duct ø 250 Tryckfall, Pressure Pa drop, Pa 100 Size Storlek Dual-purpose Kombihuv RDTZ-09-050-1 Duct Kanaldimension ø 15 315 50 20 5 0,02 0,05 0,1 0,2 0,5 1 Air Luftflöde, flow, mm /s 3 /s 1,5 0 50 100 150 200 250 300 350 400 450 500 Luftflöde, Air flow, l/s l/s Fläkt Woods 8180 GB 2012.10 8 Specifications are subject to alteration without notice

Control General TopMaster is always supplied complete with integrated control equipment. All internal components are pre connected and the unit is factory tested. The control equipment for TopMaster is developed with the intention that it should be as easy as possible to use, install and monitor. The control equipment communicates using the Modbus protocol alternative Lon Works. Operation TopMaster is supplied with a control cabinet and a control panel for operation. All menus are shown clearly in plain text. Settings and readings are carried out via the control panel. Technical specifications Operation for pumps, max 2 A Three speed DC motors for fan operation ON/OFF rotor control Daily-/Weekly-/Annual clock built into the control cabinet. Back up power for 72-hour power loss The unit is equipped with quick connectors for auxiliary equipment in direct proximity; damper actuator, sensors, valve actuator, control panel for the control cabinet. FF1 GT3 Control functions On-Off or Room temp.control Maintaining flow or pressure Night cooling Cooling recovery Summer and winter compensation Outdoor temperature controlled fan speed Extended/forced operation via timer Frost protection sensor Time program. GT12 GT1 TF1 GS1 Accessories Defrosting Filter monitor Flow monitor Designation of component parts: TF1 Supply fan FF1 Exhaust fan TS1 Thermal overload protection, automatic reset TS2 Thermal overload protection, manual reset SK1 Control equipment for power control GT1 Supply temperature sensor GT3 Extract temperature sensor GT5 Frost protection sensor on the return water GT12 Extract temperature sensor GP1 Pressure monitor for the supply filter GP2 Pressure monitor for the extract filter GP3 Pressure monitor for the supply fan GP7 Pressure monitor for rotary heat exchanger GS1 Rotation monitor HRC Fläkt Woods 8180 GB 2012.10 9 Specifications are subject to alteration without notice

Control functions Flow control The fans in TopMaster are constant flow fans. This means that they give a preset flow within their operating area regardless of the pressure of the unit. Three different set point values, min, normal and max flow, are set for the supply fan and the extract fan. Three set points for each fan allow connection of fan speed to clock, timer, push button and occupancy detector. Function: maintaining flow in the duct system. Pressure control The control board for the fans can be reset for constant pressure control. The fans in TopMaster then give a constant preset pressure and flow within their operation area. Extended and forced operation via timer Timer for external or flush mounting. Setting 0 2 hours. Function: Starts the unit at the desired flow or change of flow. Temperature control The following alternatives are available for control functions: Supply control Function: Maintaining the temperature in the supply duct at the set point. Night purging (free cooling) The Night purging setting is used during the summer half of the year. Cold outdoor can be used to cool down the premises cool the premises at night. Used outside ordinary operating time. Function: When the room temperature exceeds the set limit value and the outdoor temperature exceeds the set limit value and the difference between the limit values exceeds the set difference, the unit is started to cool the premises using fresh outdoor. The cooler is not activated. Night heating Night heating is used to prevent the premises from being cooled during the night outside the normal operating time. Function: The unit starts for full heat recovery and opens for full effect from the heater if the room temperature falls below the set value. Cooling recovery Function: Starts the rotary heat exchanger at full heat recovery for cooling the supply, when the exhaust temperature is lower than the outdoor temperature and there is a need for cooling. Outdoor temperature compensation (summer and winter compensation) Function: Shifts the set point for the supply, exhaust or room temperature. Extract control Function: Maintaining the extract temperature in the extract duct at the set point value via cascade control of the supply temperature with min. and max. restriction. Room control Function: Maintaining the temperature in the premises at the set point value via cascade control of the supply temperature with min. and max. restriction. Fläkt Woods 8180 GB 2012.10 10 Specifications are subject to alteration without notice

Control functions Controlling the heater Control signal 0-10 V for valve actuator or electric heater with built-in thyristor. Frost protection: When the unit is not in operation the water temperature is maintained at 25 C. During operation the valve is controlled so that the return temperature does not fall below 12 C. If the temperature falls below 5 C the unit stops and an alarm is triggered. Circulation pump for heater Max. current approx 2 A, 1-phase 230 V. Maintenance operation carried out via the control cabinet. Valve actuator for heater Valve actuator suitable for valves with 5.5 mm lift height and thread G 3/4". Controlling the cooler Control signal 0-10 V for cooler, water. Control signal to cooler for direct expansion, DX, closing contact. Fire protection system Afire protection system can be connected to the unit. Function: Stops the unit and buzzer. Communication Topmaster is supplied with Modbus RTU and Lon Works. Filter monitor Gives an alarm if the pressure drop over the relevant filter exceeds the set value. Not to be used in combination with the flow monitor or control of cooling coil. Flow monitor Stops the unit and gives an alarm in the event of low flow. Not to be used in combination with the filter monitor or control of cooling coil. Defrosting The rotor is defrosted in the event of freezing using the pressure monitor. Circulation pump for cooler Max. current approx 2 A, 1-phase 230 V. Maintenance operation carried out via the control cabinet. Valve actuator for cooler Valve actuator suitable for valves with 5.5 mm lift height and thread G 3/4". Fläkt Woods 8180 GB 2012.10 11 Specifications are subject to alteration without notice

Product code TopMaster Air Handling Unit RDTM-aaa-b-1-d-1-2-0-1 Sound attenuator Mounted in ductwork RDLD-aaa-1 Size (aaa) 030, 050 Unit size(aaa) 030, 050 Supply location (b) 1 = supply right 2 = supply left Adjustable feet (set, supplied unmounted) RDTZ-03-bbb-1 Heat Recovery (c) 1 = rotary heat exchanger Unit size(bbb) 030, 050 Air heater (d) 1 = electrical coil 2 = water coil Control Equipment (e) 1 = standard control, direct current motor Voltage (f) 2 = 3 x 400 V AC Units with water coils can be connected to 1 x 230V Air cooler, water Mounted in ductwork Unit size (aaa) 030, 050 Connection side(c) 2 = left RDNN-aaa-1-2-1 Spare filter (for one path) Unit size(bbb) 030, 050 Filter class (c) 1 = F5 (exhaust ) 2 = F7 (supply ) Flexible connection (supplied unmounted) Unit size(bbb) 030, 050 Manometer, flow Unit size(bbb) 030, 050 RDTZ-04-bbb-c-1 RDTZ-05-bbb RDTZ-06-bbb-1 Accessories Damper RDVA-aaa-1-1 U-tube manometer for filter (supplied unmounted) RDTZ-07-1 Unit size(aaa) 030, 050 Location (b) 1= on/off with spring return Water trap (supplied unmounted) Dual-purpose cowl RDTZ-08-1 RDTZ-09-bbb-1 Unit size(bbb) 050 Installation instruction RDTZ-36-bb-1 Language (bb) 02 = Swedish 03 = English 06 = Finnish Fläkt Woods 8180 GB 2012.10 12 Specifications are subject to alteration without notice

Product code Control cabinet STTM-4-4-ccc-ddd-1-f-4-1-86-5 Temperature control STYZ-01-86-c-d-e-f-g-0-0-2-5 Fan motor supply, TF (a) 4 = speed control with frequency inverter, FO Fan motor exhaust, FF (b) 4 = speed control with frequency inverter, FO Fan output (ccc) 004 = 350 W (size 030) 006 = 550 W (size 050) Air heater (ddd) 00 reheat 003 = hotwater, external shunt 004 = electrical heater with built-in thyristor Heat exchanger (e) 1 = rotary heat exchanger Cooling (f) cooling 1 = chilled water Voltage (g) 4= 3x400 V AC Units with water coils can be connected to 1 x 230V Delivery options (h) 1 = built-in Control unit (ii) 86 = Fläkt Woods standard Control unit display (j) 5 = character based, 8 lines Control unit (bb) 86 = Fläkt Woods standard Control situation (c) 1 = supply control, includes 1 in-duct sensor 2 = extract control, includes 1 in-duct sensorand 1 factory-fitted extract sensor inside handling unit 3 = room control, includes 1 in-duct sensor and 1 room sensor Night cooling (d) 1 = with, includes necessary room sensor and façade sensor Night-time heating (e) 1 = with, includes necessary room sensor Cooling energy recovery (f) 1 = with, includes necessary factory-fitted temperature sensor in unit handling Set point displacement (g) 1 = outdoor compensated temperature set point includes necessary in unit handling Airflow compensation (h) 0 = none Efficiency measurement (i) Type of sensor (j) 2 = NI 1000 LG Connection (k) 5 = with quick connector Fläkt Woods 8180 GB 2012.10 1 Specifications are subject to alteration without notice

Product code Communication STYZ-03-86-1-3-05-1 Defrosting STYZ-10-86-1-1-9-2 Control unit (bb) 86 = Siemens, Saphir ACX 36 Location (c) 1 = Supply fan 2 = Exhaust Function/protocol (d) 3 = Pressure control Flow sensor pressure range (ee) 05 = 0-500 Pa Delivery configuration (f) 1 = Unmounted if supplied at same time as the controls. Communication Control unit (bb) 86 = Siemens, Saphir ACX 36 Function/protocol (c) 3 = Lon Works 7 = Modbus RTU STYZ-05-86-c-d-e-2 Control unit (bb) 86 = Siemens, Saphir ACX 36 Type of heat recovery (c) 1 = rotary heat exchanger Type of defrosting (d) 1 = pressure monitor Type of sensor (e) 9= pressure monitor Delivery configuration (f) 2 = unmounted with cable and quick connector 15 = 15 m Frost protection sensor Mounted Version (c) 2 = strap-on sensor Connection (d) 2= with quick connector STYZ-11-2-2-2 Accessories (d) 1 = remote control (bb=21,22) 2 = analogous modem 3 = GSM modem incl. antenna Fl@ktnet (e) 1 = web pages only 3 = web pages + SMS Extension cable, display Length (cc) 05 = 5 m 10 = 10 m STYZ-06-86-cc-0 Fire detection Control unit (b) 1 = alarm from external fire alarm function (for potential-free contact) Filter monitor 1) Location (b) 1 = supply 2 = extract 3 = supply and extract Delivery configuration (c) 2 = unmounted, with cable and quick connector STYZ-20-1 STYZ-28-b-2 1) Supply filter monitor should not be combined with STYZ-29 and extract filter monitor should not be combined with STYZ-70 Flow monitor 2) STYZ-29-1-2 Location (b) 1 = supply Delivery configuration (c) 2 = unmounted, with cable and quick connector 2) Not to be combined with STYZ-28-1-2 Fläkt Woods 8180 GB 2012.10 1 Specifications are subject to alteration without notice

Product code Documentation control equipment Unit size(dd) 30, 50 STYZ-36-86-8-dd-1-f-g-1 Language on documentation, wiring diagram (f) 1 = swedish 3 = english 4 = finnish Language in DUC display (g) 1 = swedish 3 = english 4 = finnish Power circuit breaker (Load interrupter) 016= 16 A(size 030, 050) STYZ-39-016-1-1 Coil control Brand (bb) 20 = Siemens Scope of supply (c) 1 = actuator only 2 = valve with actuator Type of valve (d) 2 = 2-way 3 = 3-way Location (e) 1 = heating 2 = cooling Connection (f) 2 = unmounted with cable and quick connector STYZ-70-20-c-d-e-2-ggg Prolonged/forced operation Forced operation (b) 1 = prolonged operation Control via external timer (c) 0-5 timers STYZ-40-1-c-0-0-0 Kvs-value (ggg) 002 = 0.25 004 = 0.4 006 = 0.63 010 = 1.0 016 = 1.6 025 = 2.5 Kvs-value Siemens-actuator 0.25-2.5 SQS5 Fläkt Woods 8180 GB 2012.10 15 Specifications are subject to alteration without notice

We Bring Air to Life Fläkt Woods is a global leader in management. We specialize in the design and manufacture of a wide range of climate and movement solutions. Our collective experience is unrivalled. We are constantly aiming to provide systems that precisely deliver required function and performance as well as maximum energy efficiency. FWG-eQ TopMaster GB 2012.10-8180 Copyright 2012 Fläkt Woods Group Condesign Infocom AB +46 36 291 42 10 Fläkt Woods Group SA 18, avenue Louis Casaï, CH-1209 Geneva, Switzerland Tel. +41 22 309 3800 email info@flaktwoods.com www.flaktwoods.com See global website for international sales offices www.flaktwoods.com