Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Similar documents
Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Sprinkler Identification Numbers

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Submittal Packages Detailed with Items and Reviewers

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Sprinkler Identification Number (SIN)

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Sprinkler Identification Numbers

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

The Series LFII (TY3596) Residential

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model/Sprinkler Identification Numbers

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

SENJU SPRINKLER CO., LTD.

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

Automatic Sprinklers

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Automatic Sprinklers

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Model/Sprinkler Identification Number (SIN) Technical Data

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

WFD Series Waterflow Detector

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

Models BB, SD, HIP, and AP Specific Application Sprinklers For Protecting Attics General Description

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

Transcription:

Worldwide Contacts www.tyco-fire.com Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRL, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard coverage, solder type spray sprinklers designed for use in light and ordinary hazard commercial occupancies such as banks, hotels, shopping malls, schools, hospitals, etc. The recessed version of the 2.8 and 5.6 K-factor, Series TY-FRL Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 20 (1/2 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. An intermediate level version of the 5.6 and 8.0 K-factor, Series TY-FRL Pendent Sprinkler can be obtained by utilizing the Series TY-FRL Pendent Sprinkler in combination with the Model S4 Shield. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. NOTICE The Series TY-FRL Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers TY1121... Upright 2.8K, 1/2 in. NPT TY1221... Pendent 2.8K, 1/2 in. NPT TY3121... Upright 5.6K, 1/2 in. NPT TY3221.... Pendent 5.6K, 1/2 in. NPT TY4121... Upright 8.0K, 3/4 in. NPT TY4221... Pendent 8.0K, 3/4 in. NPT TY1121 is a redesignation for S1879 and G8973. TY1221 is a redesignation for S1880 and G8971. TY3121 is a redesignation for S1864 and G8974. TY3221 is a redesignation for S1865 and G8972. TY4121 is a redesignation for S1866 and G8174. TY4221 is a redesignation for S1867 and G8172. Page 1 of 6 AUGUST 2018 TFP130

Page 2 of 6 * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. PLATE SEATING 1 - Frame 5 - Link 2 - Strut Assembly 3 - Deflector * 6 - Ejection 4 - Hook Spring 9 7 - Button 8 - Seal 9 - Bushing 1 7/16" (11,1 mm) NOMINAL MAKE-IN 2" (50,8 mm) AREA STYLE 20 1/2" NPT** 2-7/8" (73,0 mm) DIA. FLANGES UPRIGHT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY1121) AND (TY1221) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT 6 5 8 7 2 4 3* * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. PLATE SEATING 1 - Frame 5 - Link 2 - Strut Assembly 3 - Deflector * 6 - Ejection 4 - Hook Spring 7-8 - Button Seal 1 7/16" (11,1 mm) NOMINAL MAKE-IN 2" (50,8 mm) AREA STYLE 20 1/2" NPT** 2-7/8" (73,0 mm) DIA. FLANGES UPRIGHT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY3121) AND (TY3221) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT 6 5 8 7 2 4 3*

Page 3 of 6 2-13/16" (71,4 mm) CEILING PLATE SEATING AREA 1 8 1-2 - 3-4 - Hook 5 - Frame Strut Deflector * Link Assembly 6 - Ejection Spring 7 - Button 8 - Seal 1/2" (12,7 mm) NOMINAL MAKE-IN 2-3/16" (55,6 mm) 2-15/16" (74,6 mm) 6 5 7 2 4 * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 3/4" NPT** FLANGES UPRIGHT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY4121) AND (TY4221) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Technical Data Approvals UL and C-UL Listed FM and NYC Approved Refer to Table A for complete approval information Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi 1/2 (40,3 LPM/bar 1/2 ) K = 5.6 GPM/psi 1/2 (80,6 LPM/bar 1/2 ) K = 8.0 GPM/psi 1/2 (115,2 LPM/bar 1/2 ) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame............................Bronze Strut.............................. Monel Deflector..........................Bronze Hook............................. Monel Link Assembly...................... Nickel Ejection Spring.................... Inconel Button............................Bronze Seal.............................TEFLON Bushing (2.8K only)...................brass Operation The fusible link (heat collector) assembly is comprised of two halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprinkler to operate. Design Criteria The TYCO Series TY-FRL Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM s Loss Prevention Data Sheets). Only the Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. 3* Installation The TYCO Series TY-FRL Sprinklers must be installed in accordance with this section. A leak tight 1/2 in. NPT sprinkler joint should be obtained with a torque of 7 to 14 lb-ft (9,5 to 19,0 N m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRL Pendent and Upright Sprinkler Installation The Series TY-FRL Pendent and Upright Sprinklers must be installed in accordance with this section. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 6). With reference to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area.

Page 4 of 6 K TYPE SPRINKLER FINISH TEMP. RATING FRAME COLOR CODE NATURAL BRASS CHROME PLATED Series TY-FRL Recessed Pendent Sprinkler Installation The Series TY-FRL Recessed Pendent Sprinklers must be installed in accordance with the following instructions. 2.8 1/2 in. NPT 5.6 1/2 in. NPT 8.0 3/4 in. NPT (TY1221) UPRIGHT (TY1121) (TY1221 w/style 20) (TY3221) UPRIGHT (TY3121) (TY3221 w/style 20) (TY4221) UPRIGHT (TY4121) 1, 2, 5 1, 2, 3, 4, 5 1, 2, 3, 5 1, 2, 3, 4, 5 1, 2, 3, 5 1, 2, 5 1, 2, 3, 5 Step A. After installing the Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 12 Recessed Sprinkler Wrench (Ref. Figure 7). With reference to Figure 1, or 2, the W-Type 12 Recessed Sprinkler Wrench is to be applied to the sprinkler wrenching flanges. Step C. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Escutcheon over the Series TY-FRL Sprinkler and push the Escutcheon over the Mounting Plate until its flange comes in contact with the ceiling. NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/03) as Quick Response Sprinklers. 5. Approved by the City of New York under MEA 112-04-E. TABLE A LABORATORY LISTINGS AND APPROVALS

Page 5 of 6 1/2±1/8" 2-7/8" DIA. 1/2" (12,7 mm) (12,7±3,2 mm) (73,0 mm) 1/4" (6,4 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA. (57,2 mm) PLATE 1/8" (3,2 mm) RECESS 1-3/4" (44,5 mm) 1-1/2" (38,1 mm) FIGURE 6 W-TYPE 9 SPRINKLER CLOSURE TY-FRL FIGURE 4 SERIES TY-FRL (TY1221) SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 2.8 K-FACTOR, 1/2 INCH NPT RECESS 1/2±1/8" 2-7/8" DIA. 1/2" (12,7 mm) (12,7±3,2 mm) (73,0 mm) 1/4" (6,4 mm) FACE OF SPRINKLER FITTING CLOSURE TY-FRL Care and Maintenance The TYCO Series TY-FRL Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. 2-1/4" DIA. (57,2 mm) PLATE 1/8" (3,2 mm) 1-3/4" (44,5 mm) 1-1/2" (38,1 mm) FIGURE 5 SERIES TY-FRL (TY3221) SPRINKLER ASSEMBLY WITH TW0-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 5.6 K-FACTOR, 1/2 INCH NPT Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modified or over-heated sprinklers must be replaced. Care must be exercised to avoid damage to the sprinklers -before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. PUSH UP TO ENSURE ENGAGEMENT WITH SPRINKLER ING AREA FIGURE 7 W-TYPE 12 SPRINKLER The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes.

Page 6 of 6 P/N 58 - XXX - X - XXX SIN 973 2.8K UPRIGHT (1/2 in. NPT) TY1121 981 2.8K (1/2 in. NPT) TY1221 974 5.6K UPRIGHT (1/2 in. NPT) TY3121 982 5.6K (1/2 in. NPT) TY3221 174 8.0K UPRIGHT (3/4 in. NPT) TY4121 172 8.0K (3/4 NPT) TY4221 SPRINKLER 1 NATURAL BRASS 9 CHROME PLATED TEMPERA- TURE RATING 165 165 F (74 C) 212 212 F (100 C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. TABLE B SERIES TY-FRL AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRL (specify SIN), (specify K-factor), (specify Upright, Pendent, or Recessed Pendent) Sprinkler Quick Response, (specify) temperature rating, (specify type of finish), P/N (specify from Table B) Recessed Escutcheon Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 9 Sprinkler Wrench, P/N 56-000-1-849 Specify: W-Type 12 Sprinkler Wrench, P/N 56-798-1-001 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a registered trademark of DuPont