BeveLED Mini - B3RA 3 Round Adjustable

Similar documents
USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

80 Watts FLANGE FINISH

USAI ADJUSTABLE. Lighting

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION FLANGE FINISH

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

SliverLED Round Downlight, 1 Regress SR11

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

PROJECT INFORMATION PROJECT

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

BeveLED Mini Trimless Acoustical - B3RDP

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

Field changeable between Trimmed / Trimless / Millwork

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

True Zero Conceal - Z3SA-C 3 Square Adjustable

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

1" Regress Trim DELIVERED PERFORMANCE - Downlight

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED Mini - B3RD 3 Round Downlight

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE TYPE

OPTIONAL LENS 2 FLANGE FINISH

BeveLED 2.1 PROJECT INFORMATION

Field changeable between Trimmed / Trimless / Millwork

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

PROJECT INFORMATION PROJECT DATE TYPE

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

SliverLED Round Adjustable, Wet Location SR21W

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

NanoLED NXT Cylinder LNRP3 Surface

BeveLED Mini - B3SD 3 Square Downlight

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED Cylinder LBRP6 Surface

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

DATE TYPE 40 DELIVERED PERFORMANCE

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

BeveLED Cylinder LBRP6 Pendant

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

BeveLED Cylinder LBRP6 Surface

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

PROJECT DATE FLANGE FINISH

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Micro Wall Wash Trimless - MWL

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Grüv Flare Regressed. Recessed Linear LED

Evoke Square Downlight

Evoke Round Adjustable C3

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Adjustable HP

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Evoke Square Downlight

Evoke Square Adjustable HP

Essenza. Square Downlights

Grüv Flare Regressed. Recessed Linear LED

Essenza. Round Downlights

Hornet HP. Semi-Recessed 4-Light Square Multiple

Evoke Square Adjustable C3M

Evoke Round Downlight

Classix 6" 6" Round Adjustable C3M

Performance Chart Electrical Data

Classix 6" 6" Round Adjustable C3

Hornet HP. Round Glass Downlight

Velato. Recessed Slot Adjustable Multiples

IHOL-4DR / IRD400 4 Gravity LED Downlight

Hornet HP. Recessed 4-Light Square Multiple

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Classix 6" 6" Round Lens Downlight

Hornet HP. Square Glass Downlight

Classix 6" 6" Round Lens Wall Wash

Performance Chart Electrical Data

Transcription:

Beve Mini - B3RA 3 Round Adjustable Universal and Field Convertible - Trim Trimless Millwork Trimmed - B3RAF Trimless - B3RAL Millwork - B3RAM Trimless Acoustical Tile - B3RAP usailighting.com/beveledmini To specify Trimless Acoustical visit usailighting.com/b3rap Introducing new and improved Beve Mini, the smallest member of of our iconic Beve family. Beve Mini has been infused with upgraded performance for superior light in every application. Now available with the following features, by popular demand: F E AT U R E S Upgraded performance and more color options than ever before! Field Flexibility - it s now easy to change trim in the field between trimmed, trimless and millwork Dry/damp/wet location rated for bathrooms and showers, including trimless and millwork More dimming options and all color technologies available Clear overspray protector for installation convenience Full family platform Iconic beveled look A DJ U S TA B L E P E R FO R M A N C E DATA COLOR CHOICES Classic Warm Glow Dimming Color Select D E L I V E R E D* PERFOR M ANCE: 9W 15W 20W 15W 20W 12W 18W Source Lumens: 1125 1600 2475 1350 1800 925 1200 Lumens Per Watt: 87 79 69 44 43 43 38 Delivered Lumens: 775 1125 1375 675 900 500 700 *Based on 3000K, CRI. Performance varies for each specific beamspread and color temperature. See IES files for exact values at usailighting.com. C O R R E L AT E D C O L O R T E M P E R AT U R E M U LT I P L I E R Classic - 9W and 15W Classic - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K Color Rendering Index: 95+ 95+ 95+ 95+ Multiplier for Lumen 1.00 0.81 1.00 0.81 1.07 0.87 1.07 0.93 0.96 0.81 0.70 1.00 0.86 0.74 1.03 0.88 0.79 1.06 0.81 0.81 Warm Glow Dimming Color Select 2700K 3000K 3500K 2200K 2700K 3000K 3500K 4000K 5000K 6000K Color Rendering Index: Multiplier for Lumen 1.00 0.78 1.00 0.83 1.05 0.92 0.97 1.00 1.03 1.05 1.10 1.13 Page 1 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

H OW T O S P E C I F Y Beve Mini - B3RA 3 Round Adjustable with Integral Driver Housings Specify fixture part number. (All boxes must be filled in to correctly order) B3RA Wattage Color Beve Trim Trim Style Choice F Trimmed with Flange (use with all materials) L Trimless Spackle-in (use with sheetrock and plaster only) M Millwork Knife-Edge (use with wood and stone) 25 Horizontal trim lens, can be used for all tilt angles from 0º-40º (provided standard) Classic Light 09X1 9W 15X1 15W 20X3 20W 27KS 2700K, CRI Housing Bevel *Flange/ Trim Finish Millwork Collar Finish 20 20º beam (2, 3, 4) WH 25 27KH 25º beam 2700K, CRI (3, 4) 27KU 2700K, 95+ CRI (1) 30KS 3000K, CRI 30KH 3000K, CRI 40 Optional cut-cone trim with canted lens, can be used for reduced clipping at tilt angles from 25º-40º Beam Lens 30KU 3000K, 95+ CRI (1) 35KS 3500K, CRI 30 30º beam 35 35º beam 40 40º beam S Solite (provided standard) SF Solite Frosted SC SC Conduit Silver Conduit Silver GR GR BF Borosilicate Frosted BZ 45 45º beam 50 50º beam (1, 2) PR Primer Finish AC Clear Matte Anodized AC Clear Matte Anodized AB Piano Gloss D4E 5 ECO, 5% (3, 4, 5) NCIC Insulation Contact Rated / Airtight D4H H ECO, 1% Fade (3, 4, 5) D6A Eldo 0-10V, 0.1% D6B Eldo 0-10V, 0.1% D7 Eldo DALI, 0.1% 120V AB Piano Gloss 3022KS 3000K-2200K, CRI EM Emergency Battery (8) EMW Emergency Battery Wet Location (8) * Residential grade nailer bars provided standard For use with 120V only D3 2-wire, 1% (7) 347V For use with 347V only D15 0-10V dim, 1% 347V only (3, 4, 5) BZ RAL Custom Color Specify RAL # CB52 52 C-Channel Bars D19 Phase 2-wire, 1% (3, 4) 2722KH 2700K-2200K, CRI CB27 27 C-Channel Bars No Additional Charge GR 2722KS 2700K-2200K, CRI Acessories (Optional)* D18 Moons DMX, 0.1% (3, 4, 5) WH Warm Glow Dimming 3522KS 3500K-2200K, CRI D6F Eldo 0-10V, 1% BZ 40KU 4000K, 95+ CRI (1) 3022KH 3000K-2200K, CRI D6E Eldo 0-10V, 1% GR 40KH 4000K, CRI 20WG2 20W (6) No Additional Charge D2 TR 0-10V dim, 10% (5) NC1 New Construction All-in-One 60 60º beam (1, 2) Dimming Driver UNV For use with Universal 120277V Voltage 120V - 277V WH 40KS 4000K, CRI 15WG2 15W Select one FTA Flat Adjustable Housing NCCP Chicago Plenum BZ PR Primer Finish 55 35KH 55º beam 3500K, CRI (3, 4) 35KU 3500K, 95+ CRI (1) WH Voltage RAL Custom Color Specify RAL # *Leave blank for Trimless Notes: 1 Not available with X1 2 Not available with X3 3 Not available for Warm Glow. 4 Not available for Color Select. 5 Not available with 9W. 6 Not available with NCIC housing. 7 Use only up to 15W max with NCIC housing 8 Not available with 347V. NC1 housing only. Requires above ceiling access for service Color Select Tunable 12CS1 12W 18CS1 18W (6) 6022KS 6000K-2200K, Tunable Light CRI T R I M FI N I S H O P T I O N S Custom colors and primer finish also available Custom RAL (example) Custom RAL (example) Page 2 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

H OW T O S P E C I F Y Beve Mini - B3RA 3 Round Adjustable with Remote Driver 1. Specify fixture part number. (All boxes must be filled in to correctly order) RM B3RA Beve Trim Trim Style Choice F Trimmed with Flange (use with all materials) L Trimless Spackle-in (use with sheetrock and plaster only) M Millwork Knife-Edge (use with wood and stone) 25 Horizontal trim lens, can be used for all tilt angles from 0º-40º (provided standard) Wattage Color Classic Light Beam Lens Bevel Trim Finish *Flange/ Millwork Collar Finish 20 20º beam (2, 3) WH WH SC Conduit Silver SC Conduit Silver GR GR 09X1 9W 27KS 2700K, CRI 15X1 15W 27KH 2700K, CRI 25 25º beam (3) 20X3 20W 27KU 2700K, 95+ CRI (1) 30 30º beam 30KS 3000K, CRI 35 35º beam 30KH 3000K, CRI 40 40º beam 30KU 3000K, 95+ CRI (1) 45 45º beam 35KS 3500K, CRI 50 50º beam (1, 2) 40 Optional cut-cone trim with canted lens, can be used for reduced clipping at tilt angles from 25º-40º 35KH 3500K, CRI S Solite (provided standard) SF Solite Frosted BF Borosilicate BZ Frosted PR Primer Finish AC AC Clear Matte Anodized Clear Matte Anodized WH 35KU 3500K, 95+ CRI (1) 40KS 4000K, CRI 40KH 4000K, CRI BZ AB Piano Gloss 40KU 4000K, 95+ CRI (1) Warm Glow Dimming 2722KS 2700K-2200K, CRI 20WG2 20W 2722KH 2700K-2200K, CRI 3022KS 3000K-2200K, CRI 3022KH 3000K-2200K, CRI RM Remote Dimming Driver, specify remote power supply in table below CB27 27 C-Channel Bars NC1 New Construction All-in-One NCIC Insulation Contact Rated / Airtight CB52 52 C-Channel Bars * Residential grade nailer bars provided standard Must Be AB Piano Gloss WH 15WG2 15W FTA Flat Adjustable Housing Supply GR 60 60º beam (1, 2) Acessories (Optional)* Power 55 55º beam (3) Remote Dimming Driver NCCP Chicago Plenum BZ PR Primer Finish Housing Specified GR BZ RAL RAL Custom Color Specify Custom Color Specify RAL # RAL # 3522KS 3500K-2200K, CRI *Leave blank for Trimless Notes: 1 Not available with X1 2 Not available with X3 3 Not available for Warm Glow 2. Specify Remote Power Supply RPB-01 Remote Power Supply RPB-01 Beve Mini Remote Power Supply Wattage Classic Voltage Remote Dimming Type and Level Remote Emergency Option UNV 120V - 277V D2 TR 0-10V, 10% (4) D4E 5 ECO, 5% (3, 4) D4H H ECO, 1% Fade (3, 4) D6A Eldo 0-10V, 0.1% D6B Eldo 0-10V, 0.1% D6E Eldo 0-10V, 1% D6F Eldo 0-10V, 1% D7 Eldo DALI, 0.1% D18 Moons DMX, 0.1% (3, 4) D3 2-wire, 1% D19 Hatch Phase 2-wire, 1% (3) 3 Not available for Warm Glow 4 Not available for 9W EM7 EM battery requires remote enclosure by others, minimum size 14.5 L x 6.5 W x 3 H 09X1 9W 15X1 15W 20X3 20W Warm Glow 15WG2 15W 20WG2 20W 120V 120V Only NOTE: Remote Power Supplies Require Enclosures by Others. See Page 6 for Details. Page 3 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

Beve Mini - B3RA 3 Round Adjustable Trimmed - B3RAF T R I M D E TA I L S Trimmed - B3RAF-40 Trimmed - B3RAF-25 1 Regress Bevel Trim Finish Bevel Trim Finish Clear acrylic overspray protector provided standard with every housing to keep out dust and contaminants during construction. Allows for use as work light. Glass Lens Glass Lens Flange Finish Flange Finish 3 Ø 3 Ø 4 Ø 4 Ø HOUSING OPTIONS Flat Adjustable Housing - FTA New Construction Housing - NC1 Insulation-Contact Rated - NCIC Chicago Plenum Rated - NCCP 4 51/2 7 1 Max Ceiling Thickness 1 Max Ceiling Thickness 191/8 67/8 10 101/8 141/2 (Plan View) 183/16 (Plan View) OPTIONAL EM OPTIONAL EM 19/16 Page 4 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

Beve Mini - B3RA 3 Round Adjustable Trimless - B3RAL T R I M D E TA I L S Trimless - B3RAL-25 Trimless - B3RAL-40 1 Regress Bevel Finish Bevel Finish Glass Lens Glass Lens 3 Ø Clear acrylic overspray protector provided standard with every housing to keep out dust and contaminants during construction. Allows for use as work light. 3 Ø HOUSING OPTIONS Flat Adjustable Housing - FTA New Construction Housing - NC1 Insulation-Contact Rated - NCIC Chicago Plenum Rated - NCCP 4 7 51/2 1 Max Ceiling Thickness 1 Max Ceiling Thickness 191/8 67/8 10 101/8 141/2 (Plan View) 183/16 (Plan View) OPTIONAL EM OPTIONAL EM 19/16 Page 5 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

Beve Mini - B3RA 3 Round Adjustable Millwork - B3RAM T R I M D E TA I L S Millwork - B3RAM-25 Millwork - B3RAM-40 1 Regress 1/16 1/16 Bevel Trim Finish Bevel Trim Finish Millwork collar finish provided to match bevel finish unless otherwise specified. Millwork collar finish provided to match bevel finish unless otherwise specified. 33/8 Ø Glass Lens Glass Lens 31/2 Ø 33/8 Ø Clear acrylic overspray protector provided standard with every housing to keep out dust and contaminants during construction. Allows for use as work light. 31/2 Ø HOUSING OPTIONS New Construction Housing - NC1 Insulation-Contact Rated - NCIC Chicago Plenum Rated - NCCP Flat Adjustable Housing - FTA 4 51/2 7 11/8 Max Ceiling Thickness 11/8 Max Ceiling Thickness 191/8 6 /8 7 10 101/8 141/2 (Plan View) 183/16 (Plan View) OPTIONAL EM OPTIONAL EM 19/16 Page 6 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

Beve Mini - B3RA 3 Round Adjustable B E V E L E D M I N I S P E C I FI C AT I O N S FI E L D R E P L AC E A B L E L E D L I G H T E N G I N E is serviceable through the aperture with a Philips screwdriver. All light engines feature industry-leading color consistency. FI E L D R E P L AC E A B L E I N T E G R A L D R I V E R Unless otherwise specified, a 0-10V, 100%-10% solid state electronic constant current integral D2 dimming driver with a high power factor is provided standard and sources 2mA. All integral dimming drivers are located within the fixture housing and are serviceable from below the ceiling through the aperture. Some ontime delay may be experienced depending on control system used. All dimming drivers comply with IEEE C62.41 surge protection. I N T E G R A L E M E R G E N C Y BAT T E RY An integral emergency battery pack is available as an option with the NC1 housing and integral driver/power supply only. IOTA emergency battery provides backup power for 90 minutes. NC1 fixtures are provided with an integral emergency battery that requires above ceiling access for service, and a remote test switch, which comes with a 24 lead length for location of the test switch. Remote EM test switch is dry/damp only; select EMW emergency option for a wet location-rated EM test switch. Fixtures that have no EM option may be connected to an inverter (by others) for emergency lighting. Battery is not available with 347V. Remote Emergency Test Switch included with NC1 housing and integral driver only. Above ceiling access required for service. R E M O T E L O C AT I O N D R I V E R Beve Mini is available for use with remotely located driver. Driver is provided separately for remote location on site, enclosure to be provided by others. Remote dimming driver power supply option must be clearly specified in the RP table. Remote power supplies require enclosures by others that meet local codes and must be located in an accessible service panel within 100ft of the light fixture; see remote driver table below for coordination of enclosure sizes and wire gauges required. All dimming drivers comply with IEEE C62.41 surge protection. Remote Power Supply Requirements and Wiring Diagram enclosure sizes and wire gauge with 1 fixture per power supply. Remote Power Supply Dimming Option RPB-01-09X1 RPB-01-15X1 RPB-01-20X3 RPB-01-15WG2 RPB-01-20WG2 UND2 UND4E UND4H UND6A UND6B UND6E UND6F UND7 UND18 120D3 120D19 Minimum Enclosure Size Required (by others) RP Only RP with EM Option** Wire Gauge Required* 0-10V dim, 10% 14/12 5 ECO, 5% 14/12 H ECO, 1% fade Eldo 0-10V, 1% Eldo 0-10V, 1% Eldo 0-10V, 1% 18/16 Eldo 0-10V, 1% Eldo DALI, 0% Moons DMX, 0% 2-wire phase, 1% 14/12 Hatch 2-wire phase, 1% 14/12 7 W x 2.625 L x 2 H 6.25 W x 4 L x 2 H 14.5 W x 6.5 L x 3 H 5.75 W X 2.625 L x 2 H Not all dimming options are availbale with all light engine options. See RP ordering table for details. * Wire gauge 14/12 = Maximum distance from light fixture to remote power supply is 100 using 12 gauge wire, 50 using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fixture to remote power supply is 100 using 16 gauge wire, 50 using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fixture. Note: All light fixtures must be wired in homeruns per wiring diagram below. HOMERUN USE FOR WIRING S MDF02M MDF04M MDF06M MDF08M DP02 DP04 DP06 DP08 INPUT WIRES SEE DIMMING COMPATIBILTY SHEETS FOR DETAILS SEE DIMMING COMPATIBILITY SHEET FOR DETAILS A RPB RP2 REMOTE REMOTE POWER POWER SUPPLY SUPPLY + + - - Page 7 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

Beve Mini - B3RA 3 Round Adjustable B E V E L E D M I N I S P E C I FI C AT I O N S TRIM Adjustable fixtures are available with two trim options. The standard trim provided (-25-) has a horizontal trim lens and can be used for all tilt angles from 0o-40o. A cut-cone trim with a canted trim lens (-40-) is optionally available for reduced clipping at tilt angles from 25-40. HOUSING All Beve Mini fixtures are field-flexible which allows for field changes from trimless or millwork to trimmed with a simple components change with parts from. Housings are fabricated of 20 ga. steel construction with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. NCIC housing for use with 9W, 12W and 15W light engines only are rated for direct contact with spray foam insulation of R-42 or less. MOUNTING B3RAF overlap flange fixtures are designed for use in sheetrock, acoustical ceiling tile, and many other ceiling materials. B3RAL trimless fixtures are provided with a spackle collar and are designed for use in sheetrock/mud-in ceiling applications. B3RAM millwork fixtures are provided with a millwork collar and are designed for use in wood/millwork and stone construction applications. Butterfly brackets and residential grade adjustable nailer bars extendible from 14 to 24 centers with integral nails are provided standard for attachment to building structure. C-channel bars are optionally available for acoustical ceiling applications. FI X T U R E W E I G H T FTA housing weighs 10 lbs. NC1, NCIC, and NCCP housings weigh 11 lbs. NC1 housing with EM weighs 14 lbs. WA R R A N T Y Based on IESNA LM80-2008, Beve has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. Ambient temperatures at fixture location should not exceed 40 C during normal operation. CEILING CUT OUT B3RAF Trimmed with Overlap Flange: 3-5/8 Ø B3RAL Trimless Spackle-in: 4-3/16 Ø B3RAM Millwork Knife-edge: 3-9/16 Ø L I S T I N GS Dry/Damp/Wet location. AC and AB trim finishes are dry/damp only. EM test switch is dry/damp only. Select EMW option for wet location remote test switch. UL2043 rated for use in air handling plenums. NRTL/CSA-US tested to UL standards. IBEW union made. NOTES Not for use in corrosive environment Use of pressure washer voids warranty PHOTOMETRICS Consult factory or website for IES files. Tested in accordance with IESNA LM79. Page 7 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

Beve Mini - B3RA 3 Round Adjustable COLOR OPTIONS Classic Light Our proprietary light engines achieve a 2-step MacAdam ellipse along the black body locus, resulting in reliable and uniform color from fixture to fixture. You ll see the results in consistently beautiful light throughout your space, whichever product you specify. Warm Glow Dimming Warm Glow Dimming provides warmth and glow once possible only in dimmed incandescent sources. Utilizing our patented proprietary algorithm and circuitry, Warm Glow Dimming technologies precisely mimic the black body curve of a standard 100W A19 lamp by gradually transitioning from 2700K, 3000K or 3500K down to 2200K. The result is virtually indistinguishable from an incandescent light source. Color Select Tunable Color Select represents the next innovation in color temperature control for advanced recessed downlighting. Color Select products allow users to adjust color temperature from 6000K down to 2200K while independently adjusting intensity to achieve ultimate control over the quality of light in a space with a single fixture type. Color Select interfaces with standard dimming and control systems. Page 8 LIGHTING COLLABORATORY LIGHTING HEADQUARTERS 2017., LLC. All rights reserved. Patents pending., Beve, Warm Glow Dimming and Color Select are registered trademarks of, LLC.

DIMMING COMPATIBILITY SELECTION GUIDE D2 / DIML2 DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) 120V / 277V Leviton Lightolier (Philips) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Part Number Output Range ilux dimmer expansion module DIN Rail dimmer DIN Rail analog output module 8 Channel dimmer module 8 Channel dimmer module IllumaTech dimmer Vega Diva CLS-EXP-DIMFLV DIN-4DIMFLV4 DIN-A08 GLX-DIMFLV8 GLXP-DIMFLV8 IP710-DLX V2000FAMU DVTXX Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER DIMMER: 0-10V 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GROUND www.usailighting.com T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-2 Revised 03/22/2017

DIMMING COMPATIBILITY SELECTION GUIDE D3 / DIML3 DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D3 / DIML3 : Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart 120V Only ETC ETC Part Number Dimmed Light Output Range Sensor+ Cabinet Unison DRd Cabinet Maestro Wireless 600W dimmer Maestro Wireless 1000W dimmer HomeWorks QS adaptive dimmer HomeWorks QS 600W dimmer HomeWorks QS 1000 W dimmer Caseta Wireless Pro 1000W dimmer Stanza dimmer RadioRA 2 adaptive dimmer RadioRA 2 1000 W dimmer myroom DIN power module HomeWorks QS wallbox power module Homeworks DIN power module HomeWorks wallbox power module GRAFIK Eye QS control unit GRAFIK Eye 3000 control unit RPM-4U module RPM-4A module GP dimming panels Ariadni CL 250W dimmer Diva CL 250W dimmer Grafik T CL or RF CL dimmer Nova T CL 250W dimmer ELV10 ELV10 MRF2-6ND-120MRF2-10ND-120HQRD-6NAHQRD-6NDHQRD-10NDPD-10NXDSZ-6NDRRD-6NARRD-10NDMQSE-4A1-D HQRJ-WPM-6D-120LQSE-4A1-D HWI-WPM-6D-120 QSGR-, QSGRJGRX-3100-, GRX-3500HW-RPM-4U-120, LP-RPM-4U-120 HW-RPM-4A-120, LP-RPM-4A-120 Various AYCL-253PDVCL-253P-, DVSCCL-253PGT-250M-, GTJ-250MNTCL-250-100%-1% 100%-1% 100%-1% 100%-1% Qty Fixtures Per Dimmer* Fixture Wattage 39W and Less 40W - 80W 1 8 1 4 1 6 1 8 1 4 1 8 1 4 1 6 1 6 1 8 1 4 1 8 1 4 1 6 1 3 1 6 1 3 1 6 1 3 1 8 1 4 1 8 1 4 1 8 1 4 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT GROUND ONLY FOR SWITCHES WITH www.usailighting.com T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-3 Revised 03/22/2017

DIMMING COMPATIBILITY SELECTION GUIDE D4E / DIML4E and D4H /DIML4H DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4E / DIML4E : 5 Series EcoSystem Driver / Dimming Driver Wiring (Dims down to 5%) 120V / 277V D4E / DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DB QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100% 5% 100% 5% 100% 5% 100% 5% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1 32 1 16 1 64 1 32 1 64 1 32 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4H / DIML4H : H Series EcoSystem Driver with Fade to (dims down to 1%) 120V / 277V D4H / DIML4H EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DB QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100% 1% 100% 1% 100% 1% 100% 1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1 32 1 16 1 64 1 32 1 64 1 32 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4E / DIML4E and D4H / DIML 4H EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 E1 WALL CONTROL PURPLE GRAY PURPLE www.usailighting.com T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-4EH Revised 03/22/2017

DIMMING COMPATIBILITY SELECTION GUIDE D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart 120V & 277V Sensor Switch enlighted Part Number Diva Nova T Energi Savr Node GP Dimming Panels Interfaces nio Control Unit DVTV/NFTV with PP-20 NTFTV with PP-20 QSN-4T16-S TVM2 Module GRX-TVI w/ GRX3503 nio EZ CU-3E-1R Dimmed Light Output Range DIML6A 6E 99% - 0.1% 1% 99% - 0.1% 1% 99% - 0.1% 1% Qty Fixtures Per Dimmer* Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g.,, non- and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart 120V & 277V Bush-Jaeger Jung Leviton Lightolier (Philips) Merten Pass & Seymour Watt Stopper Synergy ABB enlighted Part Number Electronic potentiometer Electronic potentiometer Iluma Tech dimmer Momentum (120V ONLY) Electronic potentiometer Titan Miro Wallbox Dimmers i-bus Modules Green Light Green Light Power Pack DIN Rail Analog Output Module DIN Rail 0-10V Fluorescent Dimmer ilux 0-10V Dimmer Expansion Module Control Unit 2112U-101 240-10 IP710-DLX ZP600FAM120 5729 CD4FB-W DCLV1 ISD BC SD/S 2.16.1 GLX-DIMFLV8, GLXP-DIMFLV8 GLPAC-DIMFLV4-, GLPAC-DIMFLV8GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM DIN-A08 DIN-4DIMFLV4 CLS-EXP-DIMFLV CU-3E-1R Dimmed Light Output Range DIML6B 6F Qty Fixtures Per Dimmer* Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT D6 / DIML6 0-10V DIMMING (NO RELAY) DIMMER: 0-10V GROUND CLASS 2 CONTROL WIRES DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT RELAY www.usailighting.com DIML6A, 6B 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-6 Revised 08/14/2017

DIMMING COMPATIBILITY SELECTION GUIDE D7 / DIML7 and D7E DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) www.usailighting.com T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-7 Revised 08/14/2017

DIMMING COMPATIBILITY SELECTION GUIDE D15 / DIML15 DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D15 / DIML15 : 0-10V, 347V Dimming Driver Wiring (Dims down to 1%) 347V Only 347 Acuity Douglas Hubbell Leviton Leviton D15 / DIML15 Dimmer Compatibility Chart Dimmed Light Output Range Synergy ISD-BC WPN-5721, WPN-5822 Light Hawk2 LHD-IRS3-N347-xx Illumatech IP710-DLZ with 347V relay Centura Fluorescent Control System Nova NFT* dimmer plus 347V relay Diva DVT* dimmer plus 347V relay Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D15 / DIML15 0-10V DIMMING W/RELAY TO SWITCH POWER DIMMER: 0-10V 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIML2 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT GROUND www.usailighting.com T 845 565 8500 F 845 561 1130 NOTE: Quickship fixtures are shipped prewired for 0-10V dimming controls. If switched, nondimming operation is desired, cap off purple and gray wires separately at installation. Do NOT cap purple and gray wires together. 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-15 Revised 03/22/2017

DIMMING COMPATIBILITY SELECTION GUIDE D18 DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D18 Dimming Driver Wiring D18 are programmed dimming drivers. D18 Moons DMX control dims from 100% to 1% DMX BUS SHIELDED DATA CAE The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device, provided through Dip Switch on connection board, should be used on last fixture in line on a circuit to avoid signal loss. D18 DMX CONTROLS Terminatio Termination Resistor DMX BUS BU SHIELDED DATA CA CAE SHIE SH IELD LD DM DMX IN SHIELD SHIE LD SHIE SH IELD LD DM DMX OUT OU DMX ((-) SHIE SH IELD LD DMX (+ (+) DMX 512 CONTROLLER CONTROLLER (BY OTHERS OTHERS) / LE (+) (+) ( +) (-) ACK(-) (-) ACK(-) ACK WHIT GREE GN GN www.usailighting.com T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-18 Revised 07/03/2018

DIMMING COMPATIBILITY SELECTION GUIDE D19 / DIML19 DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D19 / DIML19 : Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT GROUND ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification S-600P sheet to determine S-603P number of fixtures D600P per dimmer. Max number D603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Leviton 6615 IPE04-xxx NTEL300 NTEL600 SEL300P SEL303P DVEL300P DVEL303P www.usailighting.com Qty Fixtures Per Dimmer Use fixture wattage per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. T 845 565 8500 F 845 561 1130 2016., LLC. All rights reserved. All designs protected by copyright. I2-264-19 Revised 03/22/2017