OPERATION INSTRUCTION

Similar documents
Split System, 18,000-48,000 Btu/h Underceiling Type MCC Series 50 Hz

Wall Mounted Mini Split Heat Pump Air Conditioner

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

Buttons on remote controller

Using the Remote Control Unit

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

53 KNL / 53 QNL OWNER S MANUAL

WIRED REMOTE CONTROLLER

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

40KMC KMQ

XS1271 XS1872 INSTRUCTION MANUAL MODE D EMPLOI This air conditioner uses the new refrigerant R410A.

Remote Control Instructions

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

Inverter Split-type Room Air Conditioner

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

XHS1271 XHS1872. This air conditioner uses the new refrigerant R410A. COOL/DRY/HEAT Model

OWNER S MANUAL ENGLISH REMOTE CONTROLLER R05 YDS-R

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

Portable Air Conditioner

PORTABLE AIR CONDITIONER

2. Pictographs 2.1 Basic Operation

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS


DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

OPERATING INSTRUCTIONS

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Owner s Manual TABLE OF CONTENTS

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

KSD-35 DR11 KUE-35 DVN11

Owner s Manual TABLE OF CONTENTS

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Slim Line Ceiling Concealed Ducted Split Systems

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

Owner s Manual TABLE OF CONTENTS

Operating Instructions

AC-12200E Portable Air Conditioner

BTU Units WORKING PROGRAM MANUAL

Features. Simple One-touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation.

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

High Wall Split Air Conditioners 53QHCT KHCT

Operation&Installation manual

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Operating Instructions Air Conditioner

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

Owner s Manual Super-Slim Four-Way Cassette

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL

Remote Controller. <Open the front cover> <ARC452A4>

Portable Air Conditioner

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Remote Control Features & Functions. (78) Symphony Solo Series Remote Control USERS GUIDE

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

WORKING PROGRAM. Heating dehumidifying cooling T 27

5) Do not start or stop the unit by inserting or pulling out the power plug.

Operating Instructions

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Split Air Conditioner

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

Operating Instructions Air Conditioner

12,000 BTU Evaporative Portable Air Conditioner

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

P O R T A B L E Air Conditioner

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Model No. SG-PAC-10E2 Reference No. KY ,000 BTU Portable Air Conditioner Operating Instructions

SPLIT - TYPE ROOM AIR CONDITIONER

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

KMHS1872 KMHS2472 INSTRUCTION MANUAL MODE D EMPLOI. COOL/DRY/HEAT Model. Save These Instructions! Conserver ce mode d emploi

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST20AG. Outdoor Unit AOT20AN P/N

Operating Instructions Air Conditioner

AIR CONDITIONER (SPLIT TYPE)

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

NEXXOS INVERTER USER MANUAL

Portable Room Air Conditioner Remote Control for:

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Hi Wall Split Air Conditioners

DVC/DVH 09/12/18/24 Series

Transcription:

OPERATION INSTRUCTION FLOOR /CEILING INDOOR UNIT MODEL: SMUL 12,18,24,30,36,48,60 Read this operating instructions carefully and keep it for furture reference. RHEEM-02 REV 00

OPERATING GUIDE 10 3 PART NAMES AND THEIR FUNCTIONS * Should not set temperature lower than your need. * To distribute cool air through out room,adjust Because it would cost the electrical fee. Air flow direction as arrows show(see picture) For disseminated cool. * Cleaning the air filter every other weeks for higher * Close window and door while operating to efficiency. Prevent cooling leakage. * Draw curtains or close glass window when cooling * In case ineffective ventilation fan. Open to prevent heat gain from sun light and not to load window to ventitate room air once in awhile the units functioning which may cause more electricity. But not to long since cooling will be use lessly drained out

4 9 REMOTE CONTROL UNIT MAINTENANCE A AUTO Before inspection and maintenance, the unit always set The Power switch OFF cut off power supply. 8 1 4 2 7 ECONO 25 C MODE FAN 5 TIMER HR MIN SLEEP CONTROL BUTTONS 1. POWER Press POWER button to turn on. Press this key again to turn off. 3 6 3. TEMP Press TEMP to decrease the temperature. ( 1 C o or 1 F o per step) Press TEMP + to increase the temperature. ( 1 C o or 1 F o per step) 3.1 CLEAN THE AIR FILTERS Removing the air filter clean by vacuum cleaner or it is very dirty, wash with soap then wipe off untill it is completely Before reinstallation. SUGGESTION : * If the air filter is dirty,it will cause the reduction of airflow; The unit is overload and consume 5% more of electricity. So regular cleaning is necessary. 3.2 CLEAN THE UNIT Clean the air conditioner and remote control with dry cloth. Remove moisture by wiping dry cloth afterward. *Do not use benzine gasoline,thinners poliishing products for cleaning. *Do not wash in hot water( above 40 C o ) some parts of the unit may be deformed. 2.FAN There are 3 laves speed control. Press this button to control the following LOW MED HIGH AUTO Press TEMP + key and TEMP- key together, to change from 1 C o or 1 F o or vice versa. 3.3 AT THE START OF THE SEASON *Check that nothing blocks the air inlet and outlet of indoor and outdoor units. *Runing the unit without air filters can cause mal-function due to dirt or dust always install air filters at all time. *Chack that drainage hose not bent or clogged. 3.4 DURING THE OFF SEASON * Cut off the power supply main swich. * Clean the air filters and other parts. * Leave the circulation fan running for 2-3 hr to day out inside of the unit.

CHECKING BEFORE CONTACT SERVICE MAN Checking the following before contact the service man.you may find the solution to your problems. After checking, It still does operate, please your local dealer. No operation PLOBLEM CAUSES Air condition runs but fewer cools. Vapor or mist fume coming out of the unit while running. In operating remote control. * Check if electrical wire is damage &check if switch breaker is still on. * Check power supply. * Check timer switch. * Check the preset temperature. * Check the sunlight whether it shines directly into room. * Check the door and windows whether it is opened * Check something whether it obstructs air discharge louver. * Check exhaust fan whether it stall operates. * Check the air filter whether it is dirty. * Hot air in the room mixes with cool air, it causes smoke alike. * loosen or disconnected wire between the remote control. * Check the batteries inserted in correct directions. * Check the batteries expired. 8 5 4.MODE There are 2 modes. Press Mode button to select. (all icon will show on LCD) COOL FAN COOL Model COOL: To control Temperature from warm to cool. (Range for setting are 20-30 o C or 68-86 o F ** This mode can control all other feature** Mode FAN: Operate same as Normal fan. **When in this mode Temp+, Temp- and Sleep button will not operate** 5. TIMER Press TIMER buttom for Timer on/off control. Press this button to set timer on(power must be off) Press this button again to cancel timer on. Press this button to set timer off(power must be on). Press this button again to cancel timer off. **Timer disply will show for 5 sec and will turn off automatically. Press timer again for disply. 6. SLEEP Press SLEEP button to control on/off sleep function (icon SLEEP will show on LCD).If sleep is ON fan will be set to auto speed.

7. HR.,MIN. Press HR. or MIN. button for setting of timer on/off. -HR. button will change the hour from 0 12 hours by 1 hr. per step. -MIN. button will change the minute from 00-50 minutes by 10 minutes per step. 6 SET CLOCK -Go to power off. -Press HR and MIN.key together for 1 sec. LCD will show SET,Clock will blink. -Within 5 sec press Temp+ or Temp- to set time. Press and hold key Temp+ or Temp- to speed Setting. -Press key TIMER or HR or MIN to quit. (or, auto quit in 5 sec) 8. ECONO 25 0 C This button will operate by change from any mode To 25 C in cool Mode and Fan will change to Auto Other setting will retain (This function design for save electrical energy POWER ON/OFF WITHOUT REMOTE There is power switch on main unit. You can power on/off by this switch. This default status will operate by power on by switch.the default status working are following. - Working on cool mode 24 o C temperature setting. LED DISPLAY PANEL - Power LED.It will lid when power On and off. - timer LED.It will on when timer setting. If timer LEDS is brinking. It means, there are some problem about the thermistor connector sensor. Please call your local technical service. **All LEDS are option for different model of main** EMERGENCY OPERATION In those following case,use button For emergency operation instead of the remote Control. * When batteries of remote control are expired. * When loss of the remote control. * When remote control out off function. * To test the unit during installation. 7 AIRFLOW DIRECTION ADJUSTMENT * HORIZONTAL ADJUSTMENT ( OPTION ) ** Press SWING button for automatic airflow direction operation,to stop the function press SWING button again * VERTICAL ADJUSTMENT **Adjust the vertical airflow direction louver directly by hand. HOW TO USE THE EMERGENCY BUTTON Press to turn on or turn off the air conditioner hh