Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Similar documents
DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

BERMAD Fire Protection

Series 759 FireLock Alarm Check Valve

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Deluge & Preac tion Systems

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

OPEN SPRINKLER SYSTEM

TECHNICAL. Series 18. Pump Packages

TotalPac X Single interlock SUREFIRE system

Discontinued Product

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Fire Protection Solutions

Flow Control for Fire Protection

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA. 319a. January 27, 2012

SECTION STEAM CONDENSATE PUMPS

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TECHNICAL DATA OBSOLETE

Flow Control for Fire Protection

TECHNICAL DATA OBSOLETE

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

TOTALPAC2 Integrated Fire Protection System

TotalPac X Firecycle III Preaction Double interlock system

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

Model DDX Deluge Valve

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

TECHNICAL DATA. model c-2

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

VALVES SECTION 15100

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

CLA-VALTM. Fire Protection Solutions: Automatic Control Valves for protecting life and property. For Commercial and Offshore Applications

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

All electrical systems and components require CSA approval stamped on the nameplate of the heater.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

DIVISION FINNED WATER-TUBE WATER HEATERS

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

13-1. Temperature Regulator

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.)

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

SECTION DOMESTIC WATER PIPING SPECIALTIES

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

KRAL Screw Pumps. L Series.

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Ruhrpumpen Fire Systems

mechanical. OPERATION Rapidrop Global

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

F4060 RESILIENT SEATED GATE VALVES

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

MARLOW PUMPS RECIRCULATION

Industrial. Solutions brands you trust. Product Overview

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

esfr dry pendent sprinkler Vk502 (k14.0)

Refrigerant Valves/Accessories

esfr dry pendent sprinkler Vk501 (k14.0)

TotalPac 3 Firecyle III Deluge Remote controlled system

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

SECTION FIRE PUMP AND CONTROLS

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

YALE Site Specifications AIR VENT SCHEDULE

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Unequaled I Unrivaled I Performance

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Chilled Water DOAS Fan Powered Terminal Units

Models Series Series

Rhino AB Upper Check Valve Replacement

High Capacity Instantaneous Steam Fired Water Heater

A. This section includes design and performance information for fire protection and suppression systems.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

HIPPS High Integrity Pressure Protection System

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Transcription:

Fire Protection Div. Dorot Fire Protection Division Deluge Valves Model 68 DE\ EL Electrically Actuated Remote-Reset Deluge Valve Certification & compliance by design 1 ANSI FCI 70-2 Class VI seat leakage class UL listed under VLFT category Fire tested to EN ISO 6182-5:2006 SIL 3-4 to IEC 65508/65111 in redundant system configuration Lloyd s & ABS type approvals Designed for High-pressure (PN25/375psi), high-flow deluge systems Automatic or local manual emergency actuation Hazardous-flammable and explosion classified area fire suppression Onshore & Offshore, Naval, Industrial, Commercial & Residential fire suppression Features Superior design featuring exceptionally low pressure losses at high flow rates Low to negligible lifelong maintenance costs thanks to no wetted metallic and mechanical moving parts design Simple, comprised of 3 main parts, no expertise required for maintenance Fresh or Brackish water, seawater and foam Out of box fully assembled & tested valves All valves are factory trimmed for both vertical & horizontal installations without modification Extensive valve & trim materials selection and corrosion protection coating to EN12944 C4, C5 & C5M Typical applications Automatic or Manual actuated Fire Suppression Systems Petrochemical, Oil & Gas Installations Tunnels Power Generation, Transformer & Transmission Plants Flammable Storage Hangars & Airport terminals Onshore-offshore Mining Deluge Valves

Deluge Valve Fire Protection Div. General description and operation modes This electrically actuated, remote-reset deluge valve is designed for fire protection systems controlled by a fire alarm control panel (F&G panel) and actuated by a solenoid valve acting as the automatic release device. The basic control valve type used in this deluge system is a direct-sealing elastomeric diaphragm, hydraulically operated control valve engineered specifically for fire protection systems. The system includes a 2/2-way N.C. solenoid as the interface between the fire alarm control panel - monitoring heat, smoke or flames - and the deluge valve. In the stand-by position, the deluge valve is held closed by the upstream water pressure, trapped in the valve's control chamber. The water pressure enters the control chamber through the priming line ball valve [2], a Y-Type strainer [3], a check valve [4] and a T-restrictor [5]. Under fire conditions, a fire alarm control panel energizes the 2/2-way N.C. solenoid [9] (or de-energizes the coil of a continuously energized ED 100% normally open solenoid for SIL 3-4 rated systems). Water is drained from the deluge valve s control chamber through the 2/2-way N.C. solenoid [9]. The deluge valve opens instantly and allows water to flow into the pipeline and through the open sprinklers over the protected area. Manual emergency actuation is enabled by opening the emergency manual activation valve [6]. The deluge valve opens instantly and allows water to flow into the pipeline and through the open sprinklers over the protected area. Resetting, maintenance and periodic testing instructions must be followed as described in detail in the relevant Dorot DE\EL model's IOM (Installation, Operation & Maintenance) manual. Standby Position Electrically Actuated [6] [9] F&G Sensor Line [6] [9] F&G Sensor Line [2] [3] [4] [5] [2] [3] [4] [5] Water [1] Water [1] To System Manually Actuated [6] [9] [2] [3] [4] [5] F&G Sensor Line Water [1] To System 2

Deluge Valve Typical control trim materials ID Description Standard POG (1) Applications 1 Dorot valve body See Series 100 Engineering data (2) 2 Ball valve Brass \ SST ball SST316 3 Y-Type strainer Brass \ SST screen SST316 4 Check valve Brass SST316 5 T-restrictor Brass SST316 6 Manual emergency valve Brass SST316 7 Drip valve Brass SST316 8 Pressure gauge Brass case \ SST connection SST316 9 2/2-way N.C. solenoid (3) Brass SST316 (1) Petrochemical, Oil & Gas (2) Refer to material selection guidelines, Engineering Data - Materials: Ductile Iron A-536 65-45-12; Cast Steel A-216 WCB; Cast Steel A-352 LCB; Austenitic Stainless-Steel A-351/CF8M; Super Duplex 2507; Nickel-Aluminum-Bronze B-148 UNS C95800 (3) Refer to solenoid selection guidelines 2 3 4 8 5 9 6 7 1 3

Deluge Valve Fire Protection Div. General arrangement and valve dimensions Valve 2 & 2.5 (50&65) 3 (80) 4 (100) 6 (150) 8 (200) 10 (250) inch mm inch mm inch mm inch mm inch mm inch mm A 10 254 12 310 14 355 17 443 21 530 25 635 B 6 5 / 8 168 8 200 9 238 12 306 14 360 17 430 C 5 126 6 159 7 173 8 202 10 242 11 291 D 6 3 / 16 157 6 157 6 157 6 160 8 200 10 249 E 9 3 / 16 234 12 300 12 296 15 379 16 399 17 422 F 9 11 / 16 246 10 246 10 246 10 246 10 265 12 317 Approx. Weight * Approximate dimensions Ibs kg Ibs kg Ibs kg Ibs kg Ibs kg Ibs kg 29 13 73 33 90 41 172 78 278 126 425 193 F 247 E B A C D Optional Upstream Drain Valve Brass 190 SST 4

Deluge Valve Fire Protection Div. Typical system layout Dorot s DE\EL, electrically actuated, remote-reset deluge valve is held shut drip-tight in its stand-by position. When a fire alarm control panel energizes the 2/2 way N.C. solenoid (or de-energizes the coil of a continuously energized ED 100% normally open solenoid for SIL 3-4 rated systems), the deluge valve's control chamber is vented. The deluge valve opens instantly and allows water to flow into the pipeline and through the open sprinklers over the protected area. 4 3 1 1 Electrically actuated remote-reset deluge valve 2 Fire alarm control panel 3 2/2-way N.C. solenoid 4 Heat/smoke/other detectors 5 2

Fire Protection Div. Deluge Valve Ordering guide 68 P SS - 3 - AN15RF - DE\EL - S - PI-HA-... Model 68 68 Optional add-on Optional add-on PI Pressure switch Spring P HA Alarm test trim Position Indicator I UV Upstream drain valve Material LS Limit-proximity switch Ductile Iron Ex Explosion-proof Cast Steel CS Trim CF8M (SST316) SS Brass-Copper Ni-Al-Br NAB S Stainless Steel 316 Size (inch) 2-24 X Other Ordering example: 68PSS-3-AN15RF-DE\EL-S-PI-HA Technical data: Media up to 80 C = 176 F Elastomers suitable for extreme climates are available upon request. Sizes: Straight Flow: 2-24 Angle: 1.5-8 UL listed sizes: Model 68: 2-10 End connections: Flanged: ISO PN10, ISO-PN16 & ISO-PN25 ANSI B16.42 Class # 150 and # 300 AS Tables D & E, JIS Additional options available upon request Grooved: Sizes: 2-8 AN15RF AN30RF GRV ISO PN16 ISO PN25 xxx Pressure rating: 250 psi for Class #150 375 psi for Class #300 Please specify in addition to the above: Electrical features other than standard (24VDC, IP65/NEMA4) If explosion-proof accessories are required such as solenoids, pressure switches, etc., please define classification. Control trim material other than standard Required standards, certifications and approval Standard- leave empty Control function End connection standard ANSI #150 (FF or RF) ANSI #300 (FF or RF) Grooved ISO PN16 ISO PN25 Other (specify) 6 Specification for engineers The deluge valve shall be hydraulically operated, direct elastomeric diaphragm-seal, single chamber weir type. The valve shall consist of three major components: the body, cover and the diaphragm assembly. The diaphragm shall be the only moving part. The diaphragm forms a sealed control chamber in the upper portion of the valve, separating operating pressure from line pressure. Packing glands stuffing boxes and dynamic o-ring seals are not permitted and there shall be no shafts, discs, bearings or pistons operating the main valve. No hourglass-shaped disc retainers shall be permitted and no V-type, U-type or other slotted type disc guides shall be used. The valve shall contain a nylon reinforced rubber diaphragm, elastic & resilient through its entire surface without vulcanized radial discs and/or reinforcements. The diaphragm shall not be guided by any shafts or bearings and shall not be in close contact with other valve parts except for its sealing surface. Maintenance, disassembly and reassembly of all the valve s components shall be made possible on site and in-line, without the need to remove the valve from the line. Standard material valves such as Ductile Iron (ASTM A-536 65-45-12) and Cast Steel (WCB A-216) should be coated with high-built fusion-bonded epoxy (FBE) and a UV protective topcoat conforming to EN12944 C4 & C5 high & very high corrosivity protection grades. Naval quality/very high corrosivity protection grade conforming to EN12944 C5M is available upon request. Other coating standards such as NORSOK or ANSI/NACE as well as coatings for special material valves such as austenitic Stainless Steel (CF8M/ASTM A-316 ) and Nickel Aluminum Bronze (ASTM B-148) can be supplied upon request. The valve should be UL listed under category VLFT for fire protection service. Dorot & Dorot companies worldwide reserve the right to make changes without notice including product specification and configuration, content, description(s), dimensions etc. The Information herein is subject to change without notice. Dorot shall not be held liable for any errors. All rights reserved. Copyright by Dorot. Dorot Control Valves www.dorot.com e-mail: fp@dorot.com Edition 01.2019