Flueing Installation Manual

Similar documents
Flueing Installation Manual For Rinnai Flamefire Heaters

Flue Installation Manual

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

SLIMFIRE 25 FLAME FIRE. Customer Operation & Installation Manual

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

INSTALLATION MANUAL Power Flued Flamefire Space Heater Co-axial Flue System

REFERENCE GUIDE. Heating. Experience Our Innovation

Operation & Installation Manual

XANDER INSERT WOOD BURNER

Evolve 951 & Product specification pages

INTERNATIONAL GAS CONVECTOR BOX

Energysaver Space Heater Co-Axial Flue System Installation Manual

Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

Specification and Installation Instructions

Specification and Installation Instructions

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Installation guide Compact 2

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Pizza Oven with Stand

Twin Wall Installation Instructions And Maintenance Guide

Remote Control Operation Manual Split Type Air Conditioner

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

TILE ROOF DUCTING KIT. instruction manual VDKRT 12 MONTH WARRANTY

STYLISTE RANGE OWNERS MANUAL SERIES 1. Styliste 6 Styliste 10. Scandia Heating (Aust) Pty Ltd

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

TRUST ONLY GENUINE COONARA WOODHEATERS

ZERO CLEARANCE Z-SYSTEM

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

Important: Appliance must be installed with a Rinnai approved flue system.

STYLISTE RANGE OWNERS MANUAL SERIES 1. Styliste 6 Styliste 10. Scandia Heating (Aust) Pty Ltd

ZERO CLEARANCE Z-SYSTEM

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Manual FOR YOUR SAFETY

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

IB1100 and IB850 Installation Manual AUSTRALIAN EDITION

TRUST ONLY GENUINE COONARA WOODHEATERS

ZERO CLEARANCE BOX INSTALLATION INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS

PelletVent Multi-fuel venting system. UL 641.

Installation & Operation Manual Fascia / Firebox / Build-In Cabinet

SAPPHIRE GAS LOG FLAME FIRE Operation / Installation Manual

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

H1200/DS H1400 H1600/DS H1600XXL/DS H1200VLG/D H12003V epi950

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:-

Wall Mounted BBQ GRHM & GRHL

Customer Operation & Installation Manual Electric Panel Heaters

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

KEEP WARM & COSY THIS WINTER WITH

Installation Manual EF5000 AUS & NZ

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

^ STUV 21: MODEL SPECIFICATIONS

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

Specialist Deluxe Series II Built-In 4 & 6 Burner BBQ BQ8342B & BQ8362B

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

SERVICE MANUAL Sapphire - RIB2312 GAS LOG FLAME FIRE

Brivis Inverter Icebox

INSTALLATION MANUAL LIST OF SECTIONS. 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5

Studio 2. Balanced Flue with Thermostatic Remote Control. Installation Instructions. For use in AU (Australia). IMPORTANT

SEPARATED COMBUSTION. General WARNING

GB162 Concentric Horizontal Vent Kit

Installation Instructions

Installation Manual. HOTFLO (EHFA/EHFD) Series. Mains Pressure Vitreous Enamel Electric Storage Water Heater

Wall Mounted BBQ Rangehood

Product Catalogue 10YEAR. Fitzroy Profile and Canterbury Classic Series 2015 WAR RAN T Y YEAR

WARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at

Models: GHF4135N GHF4170N

Installation and Maintenance Instructions

Q Series. Inverter Split Systems

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

LUCCI AIRFUSION TAKEKO CEILING FAN

IS 900 Insert - Charcoal THE WORLD S MOST EFFICIENT GAS LOG SPACE HEATERS WITH THE HIGHEST ENERGY STAR RATING!

Europa 7 Europa 7 VL Multivision 8000 Series Super 9 Visio 8 Plus

INSTALLATION & OPERATING MANUAL

Electrician Installation Manual EM-E Ceiling Fan

IB850 and IB600 Installation Manual AUSTRALIAN EDITION

SHAMIC SHEETMETAL (AUST.) PTY. LTD.

OPERATION & INSTALLATION MANUAL Power Flued Flamefire Gas Space Heaters RHFE-951ETR & RHFE-1250ETR

Studio. Freestanding Cassette Range. Instructions for Installation & Servicing. For use in AU & NZ (Australia and New Zealand)

SEPARATED COMBUSTION. General

INSTALLATION AND OPERATING INSTRUCTIONS MAUI GAS FIRES FREESTANDER AND INBUILT NATURAL GAS / LPG HEATER

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE THESE INSTRUCTIONS. Electric Wall Panel. Owner s Manual & Installation Instructions L

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN

City Series CV40E Gas Fireplace

SAPPHIRE. Gas Log Flame Fire Operation / Installation Manual MODELS: RIB2310MN/A & RIB2310ML/A. This appliance shall be installed in accordance with:

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

Portable Camping BBQ HOT 0ZI SERIES II

LUCCI AIRFUSION SHOALHAVEN CEILING FAN

Models: GHF4135N GHF4170N

BAYSIDE CALYPSO CEILING FAN

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

Installation Instructions

WARRANTY BOOKLET. Commercial Hot Water. Register online at

Water Boilers ME10EN, ME15EN. Table of Contents

Transcription:

Flueing Installation Manual For Rinnai Gas Log Flame Fire Heaters To suit Models FS35ETR FS35 IB35ETR IB35 RIBF2 / IB25 IB300ETR RIB23xx Series Royale ETR - Freestanding Royale - Freestanding Royale ETR - Inbuilt Royale - Inbuilt Slimfire 252 / 25 - Inbuilt Reflection - Inbuilt Sapphire - Freestanding/Inbuilt This appliance shall be installed in accordance with: Manufacturer s Installation Instructions Current AS/NZS 3000 & AS/NZS 5601 Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person. For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions.

BEFORE PROCEEDING WITH THE INSTALLATION OF ANY FLUE COMPONENTS PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF ALL THE REQUIREMENTS HERE IN. Rinnai 2 FLF IM

TABLE OF CONTENTS Warnings & Important Information 4 Regulatory Information... 4 Notice to Victorian Consumers... 4 Genuine Rinnai Flue Kit... 4 Flueing Options 5 Direct rigid flueing... 5 Offset rigid flueing... 5 Through wall rigid flueing... 5 Flexible flueing... 5 Connecting Direct Flueing to Heaters 6 Flue Connection Procedure... 6 Direct Flueing Using FLFKIT05 7 FLFKIT05 Components List... 7 Additional Components... 7 FLFKIT05 Assembly Procedure... 8 Offset Flueing Using FLFBEND 9 FLFBEND Components List... 9 Additional Components... 9 FLFBEND Assembly Procedure... 9 Through Wall Flueing Using FLFTWKIT 10 FLFTWKIT Components List... 10 Additional Components... 10 FLFTWKIT Assembly Procedure...11 Contacts 12 NOTE All Rinnai Flamefire rigid flue kits are certified twin wall metal systems as defined in AS/NZS 5601. This does NOT apply to flexible flue kits! Rinnai 3 FLF IM

WARNINGS & INFORMATION READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and to ensure optimum performance. Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death. DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in personal injury or death. WARNINGS: Indicates a potentially hazardous situation which, if not avoided, could result in personal injury or death. CAUTIONS: Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury or damage to the appliance. It may also be used to alert against unsafe practices. WARNING REGULATORY INFORMATION Installation of this flue must be in accordance with the following regulations: Manufacturer s Installation Instructions. Current AS/NZS 5601. Local Regulations and Municipal Building Codes including local OH&S requirements. Installation, Service & Removal ONLY by an Authorised Person. WARNING NOTICE TO VICTORIAN CONSUMERS Flue components MUST be installed by a person licensed with the Plumbing Industry Commission. ONLY a licensed person will have insurance protecting their workmanship. So make sure you use a licensed person to install this appliance and ask for your Compliance Certificate. For Further information contact the Plumbing Industry Commission on 1300 815 127. WARNING GENUINE RINNAI FLUE KIT Rinnai appliance warranty conditions will be voided if non Rinnai flue components are fitted. Rinnai appliances are NOT CERTIFIED for use with non Rinnai flue components. Rinnai 4 FLF IM

Below are the flueing options that are available with Rinnai Flamefire appliances. Refer to the relevant section of this manual for detailed installation instructions for each option. OBSTRUCTION OBSTRUCTION FLUEING OPTIONS A B C D E F G ZERO CLEARANCE BOX ZERO CLEARANCE BOX ZERO CLEARANCE BOX MASONRY FIREPLACE DIRECT RIGID FLUEING Flue is run direct from appliance to the termination point. A This method to be used with Rinnai Freestanding Flamefire models: B This method to be used with Rinnai Inbuilt Flamefire models and a Zero Clearance Box: OFFSET RIGID FLUEING Flue is run offset from appliance to the termination point to avoid obstructions in the flues path. C This method to be used with Rinnai Freestanding Flamefire models: D This method to be used with Rinnai Inbuilt Flamefire models and a Zero Clearance Box: THROUGH WALL RIGID FLUEING Flue is run offset through an external wall from appliance to the termination point. This is particularly useful in multi storey applications. E This method to be used with Rinnai Freestanding Flamefire models: F This method to be used with Rinnai Inbuilt Flamefire models and a Zero Clearance Box: FLEXIBLE FLUEING Used when installing Rinnai Flamefire appliances into masonry fireplaces. Flueing is mandatory for all models except for the RIBF2 / IB25 Slimfire and IB300ETR Reflection. Detailed installation instructions are supplied separately with these flue kits. G This method to be used with the following Rinnai Inbuilt models: CAUTION IB35 / IB35ETR Inbuilt Royale / Royale ETR and IB300ETR Reflection use Kit FLEXLINER0. RIBF2/IB25 Slimfire and RIB23xx Series Inbuilts use Kit FLEXLINER03. A Zero Clearance Box is required for all false or non masonry fireplace installations, see heater installation instructions for details. Under NO CIRCUMSTANCES should a flexible flue kit be used with a Zero Clearance Box in a false or non masonry fireplace installation. Rinnai 5 FLF IM

CONNECTING DIRECT FLUEING TO S FLUE CONNECTION PROCEDURE Position and install Heater models in accordance with instructions supplied with the heater and/or Zero Clearance kit. 1. Set slip socket A onto the swaged end of the inner flue pipe B, allowing sufficient adjustment to enable the flue assembly to be lifted clear of the appliance.! Common Connections 1 A 2. Connect the slip socket A and inner flue pipe B assembly to heater flue spigot (appliance adapter spigot of RIBF2 / IB25 / RIB23xx Series [iii]), using the appropriate Freestanding [i] / Inbuilt [ii] or [iii] methods. 3. Once in position tighten the clamp of slip socket A to secure the inner flue pipe B to the heater flue spigot. 4. Slide appliance outer flue C (short swage end towards heater) over the inner flue pipe B. [i] Freestanding Connections FS35/ETR & RIB2310 2 B 5. For Freestanding appliances [i] fit outer flue C directly to the top of the heater. 6. Ensure the appliance adapter collar is seated flush with the top of the heater as shown. 7. For Inbuilt appliances [ii] or [iii] fit outer flue C to the top panel of the Zero Clearance box. 8. Ensure the appliance adapter collar is seated flush with the top panel of the Zero Clearance Box as shown. FLAMEFIRE FS35 / FS35ETR APPLIANCE ADAPTER COLLAR TOP PANEL OF 3 C APPLIANCE ADAPTER COLLAR [ii] Inbuilt Connections FS35/ETR & IB300ETR 2 B Zero Clearance Box [iii] Inbult Connections RIBF2 / IB25 / RIB23xx Series 2 B Zero Clearance Box FLAMEFIRE IB35 / IB35ETR Removeable panel for access to flue connections. Appliance Adapter Removeable fascia and panel for access to flue connections. APPLIANCE ADAPTER COLLAR C APPLIANCE ADAPTER COLLAR C APPLIANCE ADAPTER COLLAR 3 Zero Clearance Box APPLIANCE ADAPTER COLLAR 3 Zero Clearance Box Rinnai 6 FLF IM

A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 DIRECT FLUEING USING FLFKIT05 ZERO CLEARANCE BOX Direct rigid flueing is used when running a flue direct from appliance to the termination point. The flue components supplied in Rinnai FLFKIT05 are best suited for this type of installation. The FLFKIT05 can be fitted to Inbuilt and Freestanding Rinnai Flamefire models. When installing this kit with Inbuilt models a zero clearance box is required. FLFKIT05 Components List A Slip socket 100mm Galvanised (x1) B Inner Flue Pipe 900mm x 100mm Galvanised (x4) C Appliance - Outer Flue Pipe 900mm x 145mm Powder Coated (x1) D Standard - Outer Flue Pipe 900mm x 145mm Powder Coated (x2) E Ceiling Cover Plate + 4 Fixing Screws Powder Coated (x1) F Slip Joint 900mm x 150mm Galvanised (x1) G Flue Mounting Bracket Galvanised (x1) H Spacer (Spider) Clip Stainless Steel (x1) I Flue Terminal Skirt Galvanised (x1) J Flue Terminal Galvanised (x1) Additional Components NOTE These items are NOT included in kit FLFKIT05 and if required MUST be ordered separately. Y FLF0900 Standard Flue Extension Pipe - inner & outer Outer - Powder coated 900mm x 145mm (x1) Inner - Galvanised 900mm x 100mm (x1) Z Zero Clearance Boxes ZEROR - IB35/IB35ETR Royale Inbuilt. ZEROS - RIBF2/IB25 Slimfire Inbuilt. ZBOXREF - IB300 Reflection Inbuilt. R2340 - RIB2310 Sapphire Inbuilt. APPLIANCE ADAPTER COLLAR Top-deck of appliance Rinnai 7 FLF IM

A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 DIRECT FLUEING USING FLFKIT05 FLFKIT05 Assembly Procedure Position and install Freestanding Heater models in accordance with instructions supplied with the heater. Position and install Inbuilt Heater & Zero Clearance kit using instructions supplied with Heater & Zero Clearance kit. 1. Check roof space for any obstructions. If the required clearance from combustible material can not be obtained, consider an offset installation. 65mm 2. Set plumb bob from ceiling to centre of flue outlet on heater, marking the centre position on ceiling. 3. Cut 150 mm circle in ceiling to accommodate flue penetration. 4. Screw ceiling cover plate E to ceiling with the powder coated screws provided. 5. Fit flue the assembly A, B and C to the heater as per "Connecting Direct Flueing to Heaters" on page 6. 6. Connect subsequent inner B and standard outer flue D pipes into place. Join inner flues with three galvanised screws or rivets. Repeat for B and D pipe lengths as required Continue assembly to the flue terminal to ensure compliance with current AS/NZS 5601. Minimum clearance from roof 500mm. FLUE TERMINAL / SKIRT AND INNER FLUE RIVETED TOGETHER 7. Fit slip joint F and mounting bracket G to end of the outer flue pipe D and slip downward. 8. Fit spacer (spider) clip H and secure to inner flue pipe B 65mm from the end of the pipe. MINIMUM CLEARANCE 500 mm 9. Fit terminal skirt [i] and flue terminal J to the inner flue pipe B securing all three together with three galvanised screws or rivets. 10. Slide slip joint F upwards so that the legs of the spacer (spider) clip H are covered then secure with three galvanised screws or rivets. 11. Secure mounting bracket G to slip joint F in ceiling space to support the weight of the flue system, and not place strain on roof flashing as per AS/NZS 5601. TWIN SKIN CLEARANCE FROM COMBUSTIBLE 10 mm Flash roof penetration by approved methods. (Roof flashing materials are not included in flue kit). Total vertical flue length MUST be at least 3 metres. Flue Terminal Assembly Details Rinnai 8 FLF IM

OFFSET FLUEING USING FLFBEND FLFBEND Components List K Outer 45 Elbow 145mm Powder Coated (x2) L Inner 45 Elbow 100mm Galvanised (x2) Additional Components When an obstruction prevents the use of a direct rigid flue run from the appliance to the termination point a FLFBEND kit consisting of two 45 offsets can be used to divert the flue. The FLFBEND is used in conjunction with a FLFKIT05 flue kit. The offset length can be increased by the inclusion of FLF0900M standard inner/outer flue lengths, either used in whole or cut to size. NOTE These items are NOT included in kit FLFKIT05 and if required MUST be ordered separately. Y FLF0900 Standard Flue Extension Pipe - inner & outer Outer - Powder coated 900mm x 145mm (x1) Inner - Galvanised 900mm x 100mm (x1) FLFBEND Assembly Procedure The vertical length of flue pipe between the heater and the first inner 45 elbow L (FLFBEND) should be as long as the installation allows, and at least 900mm. A Standard length of flue can be used to increase the offset 1. Connect inner 45 elbow L onto the un-swaged end of an inner flue B and join with three galvanised screws or rivets. 2. Slide outer 45 elbow K over the inner Flue 45 Elbow L and connect to outer flue pipe C or D. 3. At this point to extend the offset length use a combination of standard inner L and outer L flue pipe lengths, joining the inner flue sections with three galvanised screws or rivets. 4. The offset length can be customised by cutting the extension components to size as required. 5. Connect second inner 45 elbow L onto the preceding inner section and join with three galvanised screws or rivets. Connect the second outer 45 elbow K over the preceding outer section. 6. Join subsequent inner B and standard outer D flue pipes fixing inner sections with three galvanised screws or rivets. Continue assembly to the heater and flue terminal as per the "Direct Flueing Using FLFKIT05" on page 8. or See Note Total vertical flue length MUST be at least 3 metres. Rinnai 9 FLF IM

THROUGH WALL FLUEING USING FLFTWKIT Through wall rigid flueing is used to divert a flue run from appliance through an exterior wall to the termination point. The FLFTWKIT provides a 45 wall penetration offset with an adjustable flashing plate. As such the FLFTWKIT is ideal for two storey applications. The FLFTWKIT is used in conjunction with a FLFKIT05 flue kit. For extended external flue runs, the FLFEXT03 kit must also be used. FLFTWKIT Components List M Inner 45 Elbow 100mm Galvanised (x2) N Lower Outer 45 Elbow 145mm Powder Coated (x1) O Internal Wall Plate + 4 Fixing Screws Powder Coated (x1) P Inner Extension Pipe 100mm Galvanised (x1) Q Spacer Clamp 100mm Stainless Steel (x1) R Outer Extension Pipe 145mm Powder Coated (x1) S Transition Slip Joint 145~150mm Galvanised (x1) T Outer Transition / Wall Plate 150mm Powder Coated (x1) U Upper Outer 45 Elbow 150mm Galvanised (x1) Additional Components Q P R or V U M T S NOTE These items are NOT included in kit FLFKIT05 and if required MUST be ordered separately. V FLFEXT03 External Pipe Extension & Bracket NOTE 900mm x 150mm Galvanised (x1) 900mm x 100mm Galvanised (x1) 150mm Galvanised Victor-clip (x1) The FLFTWKIT outer transition T has a diameter of 150mm, ONLY the FLFEXT03 external pipe extensions V can be used to extend an external flue run. O N M or See Note Y FLF0900 Standard Flue Extension Pipe - inner & outer Outer - Powder coated 900mm x 145mm (x1) Inner - Galvanised 900mm x 100mm (x1) The vertical length of flue pipe between the heater and the first inner 45 elbow M (FLFTWKIT) should be as long as the installation allows, and at least 900mm. Rinnai 10 FLF IM

A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 A & B GAS COWLS 75-100 MM A.G.A. APP. NO. 4198 REG DES. NO.80782 THROUGH WALL FLUEING USING FLFTWKIT FLFTWKIT Assembly Procedure Typical Freestanding Installation The vertical length of flue pipe between the heater and the first inner 45 elbow M (FLFTWKIT) should be as long as the installation allows, and at least 900mm. 1. Connect an inner 45 elbow M onto the un-swaged end of an inner flue pipe B and join with three galvanised screws or rivets. 2. Slide lower outer 45 elbow N over the inner 45 elbow M and connect to outer flue pipe C or D. 3. Carefully fit the internal wall plate O over the end of the lower outer 45 elbow N. 4. Slide inner extension pipe P through the lower outer 45 elbow N and connect to the inner 45 elbow M. Ensure a positive connection at this joint as it will not be possible to access for fastening by screws or rivets. 5. Fit and secure the spacer clamp Q to the inner extension pipe P at approximately the mid way point of the pipe. 6. Slide outer extension pipe R over the inner extension pipe P and connect to the lower outer 45 elbow N. The inner / outer extension pipes P and R may be cut to size to shorten penetration. 7. Slide the transition slip joint S over the outer extension pipe R. 8. Slide the outer transition / wall plate T over the transition slip joint S. Seal and secure to the external wall. 9. Connect the second inner 45 elbow M onto the unswaged end of to the inner extension pipe P and join with three galvanised screws or rivets. 10. Slide upper outer 45 elbow U over the second inner 45 elbow M and connect to the outer transition / wall plate T. 11. Continue assembly to the heater and flue terminal as per the "Direct Flueing Using FLFKIT05" on page 8. For longer external runs use FLFEXT03 external pipe lengths V. V M U Q S V T Minimum Clearance 500 mm TWIN SKIN CLEARANCE FROM COMBUSTIBLE 10 mm R O M Typical Inbuilt Installation Minimum Clearance 500 mm TWIN SKIN CLEARANCE FROM COMBUSTIBLE 10 mm See Note N See Note P B D NOTE The FLFTWKIT outer transition T has a diameter of 150mm, ONLY the FLFEXT03 external pipe extensions V can be used to extend an external flue run. As standard outer flue pipes have a diameter of 145mm they are therefore NOT compatible and can NOT be used for this purpose. M Q U R T S O N M P 12. Carefully move the internal wall plate into position A and secure to the internal wall with the 4 screws provided. Zero Clearance Box B D Rinnai 11 FLF IM

Australia Pty. Ltd. ABN 74 005 138 769 100 Atlantic Drive Keysborough, Victoria 3173 P.O. Box 460 Braeside, Victoria 3195 Product Sales & Service National Help Line Tel: 1300 555 545* Fax: 1300 555 655 *Monday to Friday, 8.00am to 5.30pm EST For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au AU24752 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced at least every 2 years. With our policy of continuous improvement, we reserve the right to change, or discontinue at any time, specifications or designs without notice. 15401084 12 FLF IM Issue 7 - September 2018