Product Lists NO.1- WNS horizontal wet back steam boiler

Similar documents
COMPANY INTRODUCTION

FLUIDIZED BED BOILERS

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

MCL-BIOMIX. multifuel boiler with mixing mechanism kw FUELS MAIN FEATURES

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

INNER SEPARATION CFB. Energy-saving,Efficient, Environmental

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Easyfire Standalone biomass pellet boiler

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Boiler Basics. Design and operation

Rozp.UE2015/ kw kw

INSTALLATION AND OPERATION MANUAL

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

MCL-BIO. Fuels. Main features. multifuel biomass boiler. group of companies


THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

Leading European manufacturer of fireplace stoves and fireplace inserts

Biomass. Biomass solid fuel boiler range

Biomass Drum Dryer LMK 2000 Model

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

thea 35 MR/MN Kondens Wall-mounted condensing boiler

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

GAS AND PELLET BURNERS

Max-3 Steel Shell Boiler

Chemical Processes in the Combustion

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Importance of a Draught Regulator

TopGas Wall Hung Condensing Gas Boiler

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Rozp. UE 2015/

Combined boiler. for solid fuel and pellets

New generation heat exchanger improves industrial energy efficiency

PC-120 FLATWORK IRONERS. Advanced ironers for superior productivity, efficiency and quality results.

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

The equipment and materials shall be designed and constructed in accordance with the ASME code section I 2001 ED A02 and Chinese Standards.

Access Energy Thermapower Organic Rankine Cycle (ORC) Systems

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Condensing, pre-mixed, wall-hung gas boilers with water tank

LOW NOx MODULATING GAS BURNERS

1. The structure and its description

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Sondex - A World of Heat Exchangers For All Applications

MANUAL. Page 1/44

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

HOT AIR WOOD STOVE AIRVENT TECHNICAL DOCUMENTATION V. 1.1

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

Pioneers of heating with biomasses

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

Eco Angus Wood Pellet Boilers

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

tççç= ÜÉ~íáåÖ çéíáçåë

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

GAS ABSORPTION HEAT PUMP

SCHNEIDER-KESSEL BERLIN

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

1 VICTRIX ZEUS Superior kw I features

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

ESA Pyronics International R&D test center

25 Years IBS GmbH. Innovative and taylormade burner systems

Cleaner & More Efficient Heating Than Ever Before

VICTRIX Superior kw Export VICTRIX Superior kw X Export

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR

Boiler Technical Specifications (2013)

Multi Fuel Heating Solutions for Every Home. A Cast Iron Masterpiece

HYBRID-FYRE FLUSH WOOD INSERTS

Integrated Engineering Solutions TORNADO. Concentric Indirect Fired Air Heaters

ENERGY-SAVING TOBACCO BARN

2x58 MW Coal Fired Power Plant at Mauritius

BIOPLEX MCL-BIO INSTALLATION AND SERVICE MANUAL

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

BIOMASS COMBUSTION BOILERS

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

The iqe Boiler Range. Combination and System T Boilers.

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

English. Heating with logs & wood pellets 20-40

号 PRODUCTORS CATALOGUE. ChengDu SAND Electronic Co. Ltd

Leading European manufacturer of fireplace stoves and fireplace inserts. Fireplace inserts

Products Catalogue Innovative, cost effective and energy efficient heating solutions for household and business

CO 2 Laser. High Reliability and Performance

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Efficient CHP-plant 150 kw

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

GUCHEN THERMO TRANSPORT REFRIGERATION UNITS INTRODUCTION

ENERGY TOP. Condensing boiler solutions

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Transcription:

Product Lists NO.1- WNS horizontal wet back steam boiler Sweeping function after preset can improve conditions of burner and extend its service life The unique design of the large burning chamber can increase the radiation of hearth heating area and reduce the volume of the boiler and NOx emissions; Smoke pipes box around boiler uses multi-level sealing approaches, which is easy for maintenance of the smoke box; Furnace pipe is arranged low with a large range of water level safety. Steam evaporation surface is large, with high quality steam. With a variety of alarm interlock devices to ensure efficient, safe, reliable operation of the boiler.

Type WNS0.5 WNS1 WNS1.5 WNS2 WNS3 WNS4 WNS6 WNS 8 WNS1 0 evaporation t/h 0.5 1 1.5 2 3 4 6 8 10 MPa 0.7/1.0/1.25 1.0/1.25/1.6/2.5 1.25/1.6 Staturated steam temperatur e Light diesel oil 170/184/19 3 184/193/204/226 193/204 Nm3/ h 35 70 105 140 210 260 390 520 650 Natural 40 80 120 160 240 280 420 560 700 Liquefied 15 30 45 60 90 120 180 240 300 Pipeline 85 170 250 340 510 680 1020 1360 1700 Main DN 40 65 65 80 80 100 125 150 150 Safty DN 40 50 50 40*2 40*2 50*2 65*2 80*2 80*2 Infall DN 25 25 40 40 40 50 50 65 65 Sewage DN 40 40 40 50 50 50 50 50 50 Chimney DN 250 300 350 400 450 500 650 800 900 L Mm 3800 4500 4700 4800 5500 6310 7200 7780 8330 L1 Mm 3100 3200 3600 3800 4500 5230 5960 6320 7040 W Mm 1900 2300 2800 2900 2900 2950 3190 3440 3475 W1 Mm 1000 1880 1900 2150 2350 2350 2650 2980 3040 H Mm 2100 2680 2950 3250 3880 3120 3610 3700 3800 H1 Mm 1800 1980 2070 2250 2450 2530 2850 2920 3050 Weight T 3.3/3.6/3.9 4.6/5/5.4/ 6 5.5/5.9/6.3/6. 8 6.3/7/7.5/8. 2 10.6/11.2/12/1 3 13.8/1 5 18.5/2 0 20/22 23/26

NO.2- LSS vertical water tube steam boiler 1. Start quickly,can realize temperature and rise during a short period of time. 2. Forced circulationn,full combustion,reducing NOx emissions. 3. With multi chain protection for water level,steam,overheating. 4. Multi steam and water separation technology,quality steam. 5. External steam and water separator has national invention patent. 6. Vertical structure is compact and beautiful,which saves space and easy for installation. Type LSS0.5 LSS1 LSS1.5 LSS2 evaporation t/h 0.5 1 1.5 2 MPa 0.7/1.0 1.0/1.25 Staturated steam 170/193 184/193 temperature Light diesel oil Nm3/h 35 70 105 140 Natural 40 80 120 160 Liquefied 15 30 45 60 Pipeline 85 170 265 340 Main DN 40 50 65 80 Safty DN 40 50 50 40*2 Infall DN 25 25 32 40 Sewage DN 25 40 40 40 Chimney DN 250 350 400 500 L Mm 1830 1980 2045 2550 W Mm 1780 1980 2220 2780 H Mm 2650 3080 3380 3620 H1 Mm 2100 2300 2650 2880 Mm 1180 1380 1680 1980 Weight T 1.8/2.2 2.3/2.8 3.3/4 4.3/5.2

NO.3- LWS vertical shell type steam boiler: 1. Containing no water pipes or fire tubes, which is exempt from exploding of tubes 2. Boiler will not burn because of scaling, which reduces the maintenance cost; 3. The upper ring large steam room and separation measures for boiler and steam below water can ensure the availability of highquality steam; Double W-shaped four-pass has big heat transfer coefficient and full heat exchange, low exhaust temperature, high thermal efficiency and long service life. (Patent is protected) 4. The vertical structure is compact and beautiful, which saves space and easy for installation. Type LWS0.05-0.7 LWS0.1-0.7 LWS0.15-0.7 LWS0.2-0.7 LWS0.3-0.7 t/h 0.05 0.1 0.15 0.2 0.3 evaporation MPa 0.7 Staturated 170 steam temperature Light diesel Nm3/h 3.5 7 10.5 14 21 oil Natural 4 8 12 16 24 Liquefied 1.5 3 4.5 6 9 Pipeline 8.5 17 25.5 34 51 Main DN 15 25 25 32 32 Safty DN 20 25 25 25 25 Infall DN 15 20 20 20 20 Sewage DN 20 20 25 25 25 Chimney DN 100 120 150 150 200 L Mm 870 1020 1150 1260 1270 W Mm 930 1080 1260 1400 1570 W1 Mm 640 760 890 970 1040 H Mm 1660 1750 1840 2160 2400 H1 Mm 1460 1480 1520 1840 2090 Mm 630 750 880 960 1000 Weight T 0.33 0.47 0.61 0.78 0.85

NO.4- LDR integrated electric heating steam boiler 1. All electrical components with CE and CCC certification to ensure product safety and service life; 2. Each group of heating component is equipped with clustered flange connection, with independent design, simple structure, high mechanical strength, which is safe, reliable and easy for replacement. 3. Control mode is flexible, which can be set to manual or automatic mode, for single machine or several machine operating together; 4. Unique power switching function, which can be adjusted according to actual steam demand; 5. Automatic operation control, with water shortage, over voltage, phase loss, overheating, leakageand other protection, which can ensure security.

Type LDR0.1 LDR0.15 LDR0.2 t/h 0.1 0.15 0.2 evaporation MPa 0.7/1.0 Staturated 170/193 steam temperature Input Power KW 72 108 144 Input A 108 162 216 Current Power * KW*P 18*4 18*6 18*8/24*6 Group Main DN 25 25 32 Safty DN 25 25 25 Infall DN 20 20 20 Sewage DN 25 25 25 L Mm 1050 1100 1280/1150 1 Mm 950 950 1150/950 W1 Mm 1900 2050 2100/2050 Weight T 0.28/0.35 0.33/0.4 0.45/0.53

NO.5- WDR horizontal electric heating steam boiler All electrical components with CE and CCC certification to ensure product safety and life. Each group of heating component is equipped with clustered flange connection, with independent design, simple structure, high mechanical strength, which is safe, reliable and easy for replacement. It has a large steam room steam and good quality; Electromechanical installation is separate, and electrical control components are away from heat which is favorable for thermal dissipation protection. PLC microcomputer programmable control and display device can display the status of operating parameters and fault alarm, which realizes automatic control via the HMI. Type WDR0.75 WDR1 WDR1.5 WDR2 WDR3 WDR4 t/h 0.75 1 1.5 2 3 4 evaporation MPa 1.0/1.25 Staturated 184/193 steam temperature Input Power KW 540 720 1080 1440 2160 2880 Input A 810 1080 1620 2160 3240 4320 Current V 3N AC 50HZ 380V Pressure Power * KW*P 36*15 36*20 36*30 36*40 36*60 36*80 Group Main DN 40 40 65 65 80 100 Safty DN 2*40 2*40 2*40 2*40 2*40 2*50 Infall DN 25 25 25 25 40 40 Sewage DN 40 40 40 40 40 40 L Mm 2800 2950 3450 3500 3950 4100 L1 Mm 2400 2500 3050 2880 3200 3550 W Mm 1800 1900 2180 2000 2100 2480 W1 Mm 1550 1600 1430 1880 1980 2120 H Mm 1550 1600 2100 2500 2650 2980 H1 Mm 1300 1350 1850 1900 2100 2200 Control A Mm 1200 1200 1500 1800 2100 2400 Control B Mm 500 600 600 600 600 600 Control C Mm 1800 1800 2000 2000 2200 2200 Weight T 1.6/2.0 1.8/2.2 2.2/2.7 2.8/3.3 3.5/4.1 4.5/5.2

NO.6- LDR Split electric heating steam boiler 1. All electrical components with CE and CCC certification to ensure product safety and service life; 2. Each group of heating component is equipped with clustered flange connection, with independent design, simple structure, high mechanical strength, which is safe, reliable and easy for replacement. 3. Control mode is flexible, which can be set to manual or automatic mode, for single machine or several machine operating together; 4. Unique power switching function, which can be adjusted according to actual steam demand; 5. Automatic operation control, with water shortage, over voltage, phase loss, overheating, leakage and other protection, which can ensure security.

Type LDR0.1 LDR0.15 LDR0.2 LDR0.3 LDR0.5 t/h 0.1 0.15 0.2 0.3 0.5 evaporation MPa 0.7/1.0 Staturated 170/193 steam temperature Input Power KW 72 108 144 216 360 Input A 108 162 216 324 540 Current V 3N AC 50HZ 380V Pressure Power * KW*P 18*4 18*6 18*8/24*6 27*8 36*10 Group Main DN 25 25 32 32 50 Safty DN 25 25 25 25 25 Infall DN 20 20 20 20 20 Sewage DN 25 25 25 25 25 L Mm 1050 1100 1280/1150 1300 1580 W Mm 950 950 1150/950 1200 1350 H Mm 1900 2050 2100/2050 2200 2600 Control A Mm - - - 1200 1200 Control B Mm - - - 500 500 Control C Mm - - - 1800 1800 Weight T 0.28/0.35 0.33/0.4 0.45/0.53 0.68/0.74 0.98/1.08 (300KG/H-500KG/H IS SPLIT STRUCTURE, WITH SEPARATE BOILER CONTROL CABINET)

NO.7- CLDR vertical electric heating hot water boiler 1. Boiler can operate under, with the double signal control of and temperature, which poses no security risks. 2. It is equipped with advanced touch screen controller, digital prosecution system to achieve automatic control of boiler operation; outlet water automatic adjustment is also used, with a variety of alarm interlock devices to ensure efficient, safe, reliable operation of the boiler. 3. With perfect design, colorful, elegant and stylish appearance, compact structure, it is easy for transportation and installation. 4. Boiler is equipped with protective functions of leakage, anti zero load running, low water level, furnace body overheating, unusual temperature sensors, unusual supply voltage, heating elements phase loss. Type CLDR0.06-85/60 CLDR0.12-85/60 CLDR0.17-85/60 CLDR0.23-85/60 CLDR0.29-85/60 MW 0.06 0.12 0.17 0.23 0.29 Power Total Heat 10 4 Kcal 5 10 15 20 25 MPa Ordinary Input Power KW 60 120 180 240 300 Input A 90 180 270 360 450 Current V 3N AC 50HZ 380V Pressure Infall DN 50 65 65 65 80 Effluent DN 50 65 65 65 80 Sewage DN 25 25 25 25 25 L Mm 750 920 960 1050 1120 W Mm 900 820 860 970 1020 H Mm 1020 1200 1400 1510 1630 Weight T 0.21 0.245 0.31 0.34 0.37

NO.8- CLHS vertical oil() hot water boiler 1. Burners are used by importing, spray,burning completely,low noise. 2. Super temperature,cut water,overload,ignition failure,abnormal flameout, boiler,all can do self-test,multiple chain protection. 3. More than 90% thermal efficiency.intelligent,automatic control,with automatic temperature regulation,over-temperature standby. 4. Expansion of water testing through the atmosphere,atmospheric operation,there are no all potential safety problems. Type CLHS0.06-85/60- CLHS0.12-85/60- CLHS0.17-85/60- CLHS0.23-85/60- CLHS0.35-85/60- MW 0.06 0.12 0.17 0.23 0.35 Power Total Heat 10 4 Kcal 5 10 15 20 30 MPa Ordinary Light diesel Kg/h 5.4 10.8 16.2 21.6 32.5 oil Natural Nm3/h 5.8 11.7 17.5 23.4 35 Liquefied 2.5 5 7.5 10 15 Pipeline 14.2 28.3 42.5 56.6 85 V 3N AC 50HZ 380V Pressure Infall DN 50 50 65 65 65 Effluent DN 50 50 65 65 65 Sewage DN 25 25 25 25 25 L Mm 800 980 1150 1250 1500 W Mm 700 850 900 1000 1200 H Mm 1300 1650 1800 1950 2000 Mm 600 750 800 900 1100 Weight T 0.27 0.41 0.45 0.52 0.83

NO.9- CWDR horizontal electric heating hot water boiler 1. No noise,no pollution,sanitation,is the real green products. 2. Using high-quality stainless steel heating pipe or imported electric heating materials steel pipe to ensure long-term operation of boiler s safety. 3. Manufacturers use professional standard control cabinet,the advanced technology to produce standardized, highlevel protection. 4. Pai wiring terminals are detailed wiring logo, providing great convenience locale installation 5. According to user s requirements,the evening peak electricity use regenerative energy storage equipment design. 6. Electricity for heat, no smoke heat loss,heat efficiency as high as 98%. Type CWDR0.58-85/60 CWDR0.7-85/60 CWDR1.05-85/60 MW 0.58 0.7 1.05 Power Total Heat 10 4 Kcal 50 60 90 MPa Ordinary Input Power KW 540 720 1080 Input A 810 1080 1620 Current V 3N AC 50HZ 380V Pressure Infall DN 100 100 125 Effluent DN 100 100 125 Sewage DN 40 40 40 L Mm 2100 2500 2750 W Mm 1300 1350 1500 H Mm 1800 1900 2050 Weight T 0.95 1.65 1.87

NO.10- CWNS horizontal oil() hot water boiler 1. Furnace big high radiate,three return design,combustion air is full,high efficiency heating surface. 2. Application breathing tube additional spoiler film technology,not only expansion of heat,the dust and its self-cleaning feature can reduce thermal resistance. Improve heat transfer effectiveness. 3. More than 90% thermal efficiency.intelligent,automatic control,with automatic temperature regulation, over-temperature standby. 4. Freezing cold winter night, and other functions, and to achieve the outdoor temperature changes automatically adjust the temperature heating function to maximize energy conservation. 5. Burners are used by importing, spray,burning completely,low noise. 6. Confined by connecting structure,safe,reliable,long service life. Type CWNS0.58-85/60- YQ CWNS0.7-85/60- YQ CWNS1.05-85/60- YQ CWNS1.4-85/60- YQ CWNS1.75-85/60-YQ MW 0.58 0.7 1.05 1.4 1.75 Power Total Heat 10 4 Kcal 50 60 90 120 150 MPa Ordinary Light diesel Kg/h 54 65 97.5 130 162 oil Natural Nm3/h 58.5 70 105 140 175 Liquefied 25 30 45 60 75 Pipeline 141.5 170 255 340 425 V 3N AC 50HZ 380V Pressure Infall DN 100 100 125 150 150 Effluent DN 100 100 125 150 150 Sewage DN 40 50 50 50 50 L Mm 2900 3020 3230 3650 4100 W Mm 1500 1700 1750 1820 1890 H Mm 1700 1880 1960 2050 2100 Weight T 1.5 2.45 2.78 3.5 3.86

NO.11- LDR electric heating hot water boiler 1. Boiler can operate under, with the double signal control of and temperature, which poses no security risks. 2. It is equipped with advanced touch screen controller, digital prosecution system to achieve automatic control of boiler operation; outlet water automatic adjustment is also used, with a variety of alarm interlock devices to ensure efficient, safe, reliable operation of the boiler. 3. With perfect design, colorful, elegant and stylish appearance, compact structure, it is easy for transportation and installation. 4. Boiler is equipped with protective functions of leakage, anti zero load running, low water level, furnace body overheating, unusual temperature sensors, unusual supply voltage, heating elements phase loss. Type LDR0.12 LDR0.17 LDR0.23 LDR0.35 LDR0.47 t/h 0.12 0.17 0.23 0.35 0.47 evaporation MPa 0.4/0.7 Staturated 100/120 water temperature Input Power KW 120 180 240 360 480 Input A 180 270 360 540 720 Current V 3N AC 50HZ 380V Pressure Power * KW*P 20*6 30*6 30*8 36*10 35*14 Group Main DN 50 50 50 65 80 Safty DN 50 50 50 65 80 Infall DN 15 15 15 25 25 Sewage DN 25 25 25 25 25 L Mm 1050 1150 1280 1580 1680 W Mm 950 950 1150 1350 1500 H Mm 1900 2050 2100 2600 2950 Control A Mm - - - 1200 1200 Control B Mm - - - 500 500 Control C Mm - - - 1800 1800 Weight T 0.33/0.4 0.45/0.53 0.68/0.74 0.98/1.08 1.21/1.38 (300KG/H-500KG/H IS SPLIT STRUCTURE, WITH SEPARATE BOILER CONTROL CABINET)

NO.12- Biomass Fuel Boiler 1. This biomass pellet boiler works with biologic making method. And there is a water logging dust cleaner on the boiler, it can decrease the output waste and dust. 2. The boiler can work automatically according to the users setting program. 3. Our protected device is safe and reliable. Selecting superior controller, safety, low water alarm. 4. Stable operation,high quality steam and high thermal efficiency. 5. Boiler itself has dedusting effect, which makes the boiler soot discharge reaches the national environmental regulations indicators. 6. It is simple to clean slag only after burning completing. Type DZL1.0-1.0 DZL2.0-1.0 DZL3.0-1.25 DZL4.0-1.25 DZL5.0-1.25 DZL6.0-1.6 MW 1 2 3 4 5 6 Power Pressure Mpa 1.0 1.0 1.25 1.25 1.25 1.6 Steam Temperature 0 c 184 184 194 194 194 204 Thermal % 83 83 83 83 83 83 efficiency Design fuel Biomass Fuel Kg/h 170 340 510 680 850 1020 consumption L Mm 3900 4800 5600 5900 6500 7100 W Mm 1810 2170 2430 2430 3200 3300 H Mm 3850 4700 4700 4900 5800 6100 Weight T 15 20 23 26 30 35

NO.13- Heavy oil boiler 1. Sweeping function after preset can improve conditions of burner and extend its service life. 2. The unique design of the large burning chamber can increase the radiation of hearth heating area and reduce the volume of the boiler and NOx emissions; 3. Smoke pipes box around boiler uses multi-level sealing approaches, which is easy for maintenance of the smoke box; 4. Horizontal structure has area ample heated and adequate heat transfer, the boiler is stable in running when load changes, and combustion efficiency is high. Furnace pipe is arranged low with a large range of water level safety. Steam evaporation surface is large, with high quality steam. 5. It is equipped with advanced touch screen controller, digital prosecution system to achieve automatic control of boiler operation, with a variety of alarm interlock devices to ensure efficient, safe, reliable operation of the boiler. Type WNS10 t/h 10 evaporation MPa 1.25/1.6 Staturated 193/204 steam temperature Light diesel Nm3/h 650 oil Natural 700 Liquefied 300 Pipeline 1700 Main DN 150 Safty DN 80*2 Infall DN 65 Sewage DN 50 Chimney DN 900 L Mm 8330 L1 Mm 7040 W Mm 3475 W1 Mm 3040 H Mm 3800 H1 Mm 3050 Weight T 23/26

NO.14- YY(Q)W Horizontal Oil Gas Thermal Oil Boiler Thermal Oil Boiler belongs to the ready assembly and integrative boiler, making the installation more easy and convenient, with no need of special foundation; it adopts three-pass structure with more efficient heating. Fuels: coal, wood pellets, biomass, diesel oil, heavy oil, natural, city coal, coal oven, producer with low thermal value, liquefied, industrial combustible waste and waste, etc. The Features: Three-pass structure, occupying less storage space; All Hand welding in the production processes; Low fuel consumption, less pollution; Diesel Burner imported from Italy (Brand: Baltur); Intelligent control system & simulation screen controller; Central processor control; Automatic ignition and shutdown procedure control Automatic combustion control; Automatic switching and control of circulating pump; Automatic fault processing and alarm.

Type Power Thermal efficiency Design Pressure Highest Temperat ure of Medium Medium Capacity of Boiler Circulatio n Oil Volume DN Of Oil Outlet Oil Installed Capacity Gas Installed Capacity L 600(50)Y.Q 850(75)Y.Q 1200(100) 1500(125) 1800(150) 2400(200) 3500(300) 4100(350) 6000(500) K 600 850 1200 1500 1800 2400 3500 4100 6000 W % 90 90 90 92 92 92 92 92 92 Mp 1 1 1 1 1 1 1.1 1.1 1.1 a 0 c 350 350 350 350 350 350 350 350 350 M 3 0.4 0.52 0.76 0.95 1.48 2.1 2.4 2.53 6.1 M 3 / h M m K W K W 80 80 100 100 160 200 200 200 300 100 100 125 125 150 200 200 200 250 30 40 40 45 50 70 70 70 150 20 40 40 45 50 70 70 70 150 M 3650 4100 5500 5700 5900 6500 8000 8200 9000 m W M 1500 1700 2100 2100 2100 2300 2400 2500 3200 m H M 1870 2100 2400 2400 2550 2750 2900 3000 3600 m Transport M 3250 3800 4600 4850 5100 5800 6800 7200 7800 L m Transport M 1500 1700 2100 2100 2100 2300 2400 2500 3200 W m Transport M 1870 2100 2400 2400 2550 2750 2900 3000 3600 H m Weight T 3.53 4.5 5.6 6.2 9.5 10.5 13.5 16 28.9 Address: Address: Room 506-507, Chengkai Business Center, No.800 Yinxiu Road, Wuxi City, China 214063 Tel: 86 13347900076 Fax: 86-510-81019777 Email: justin@ocean-cross.org Web: www.ocean-cross.org