OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

Similar documents
OUH Suspended Oil Unit Heater

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

Powrmatic PZN / PZN X Hot Water Heater

PT Radiant Heater Range

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Radiant Heaters Vacuum / Forced U-Tube & Linear Range

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

NVx Suspended Gas Unit Heater

HEM Heat Exchange Modules

BENSON.... Variante3 Fired Unit Heaters...

VPC Gas Cabinet Heater Range

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

NVxEA External Gas Unit Heater

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

Radiant Heater Range SRP Superior Radiant Products From Powrmatic

CPx Gas & Oil Cabinet Heater Industrial & Commercial Heating Systems

NVS Condensing Gas Suspended Unit Heater

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Heat Exchanger models

NVx Suspended Gas Unit Heater Range

PSO Gas & Oil Cabinet Heater Range

Destratification Fans Industrial & Commercial Heating Systems

Powrmatic Control Systems Industrial & Commercial Heating Systems

CPx Gas & Oil Cabinet Heater Range

Installation Instructions

Heat Exchanger models

Users, Installation and Servicing Instructions

OUH Suspended Oil Unit Heater

Flue & Flue Kits for NVx, VPC & NVS

RBR Relay Boxes. Installation Manual. Industrial & Commercial Heating Systems. Doc Ref: M406 Issue 1.

The NCA-G Range. Installation and Servicing Instructions WARNING: THIS APPLIANCE MUST BE EARTHED

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CPx Gas or Oil Cabinet Heater Range

CECx Destratification Fan

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Gas-fired unit heaters for indoor installation

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

RBR Relay Boxes. Installation Manual. Industrial & Commercial Heating Systems. Doc Ref: M406 Issue 1.

SB Range Universal Oil Heaters with Automatic Ignition

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

Exhaust Duct Design Page 1 of (C)

BENSON VARIANTE 2 RANGE

PREEVA air handling unit

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Aegean Range. A new range of fan coils for heating and cooling commercial applications

... UDSA - UDSBD Gas fired unit heaters...

The NCE-AG and CPE-AG Ranges Range

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

WHHR Midi & Midi Lite

SCHOOL OF ENGINEERING. BSc(HONS) IN QUANTITY SURVEYING & COMMERCIAL MANAGEMENT SEMESTER 1 EXAMINATION 2015/2016 RISK AND VALUE MANAGEMENT

Units for suspended ceilings

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

VORTEX BLUE OIL RANGE

CP Range. Users, Installation & Servicing Instructions Gas & Oil Fired Heaters TESTED

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Technical and Dimensional Data. Saf-T Vent SC Plus

Application instructions

Powrmaster TE Heater Range

Installation and Operating Manual Drying Cabinet

SMOKE CONTROL - NEW DIRECTIONS

VORTEX BLUE OIL RANGE

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR VARIANTE² BI DIRECTIONAL NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

FMH Range Hoods. Installation, Operation & Maintenance Instructions

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

940ESO Tankless Water Heater

BENSON VARIANTE 2 RANGE. Headin BI DIRECTIONAL NATURAL GAS (G20 I 2H ) PROPANE GAS (G31 I 3P ) TUBULAR HEATER

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

BENSON VARIANTE 2 RANGE

Recessed. Air Curtain. Fig 1. Recessed air curtain

Venting of Gas Fired Equipment RV

BENSON LINEAR RADIANT TUBE

Thank you for choosing EnviroVent

ASSEMBLY, INSTALLATION & SERVICING MANUAL OUH SERIES OIL UNIT HEATER

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

BENSON GAS UNIT HEATERS

Installation and Maintenance

Transcription:

OUH Oil Unit Heater Range ontrolling your working environment heating ventilation integrity 1

Product Overview Benefits Installer riendly ompact Stainless steel combustion chamber/heat exchanger as standard Riello burners 35 and 28 second fuel oil options Axial fan versions for freeblowing applications entrifugal fan option for ducted applications aring or The nvironment High efficiency A approved nodels Biofuel options Peace Of ind ore than fifty years experience in warm air Two year parts and one year labour guarantee Ten year combustion chamber/heat exchanger warranty onfiguration Powrmatic OUH oil fired unit heaters can be supplied in axial fan freeblowing format, to be installed directly into the space to be heated, or with centrifugal fan for ducted applications. Heaters are generally arranged for on/off operation however they may also be specified with high/low heat output. fficiencies uel usage and emissions are a key consideration. Additionally, all heaters have efficiencies which meet or exceed the requirements of both current Building Regulations and the United Kingdom nhanced apital Allowance scheme. abinet Of unitary construction and finished with hardwearing epoxy powder coat stove baked paint. ombustion hamber/heat xchanger anufactured from 304 grade stainless steel and life cycle tested to ensure long service life. Burners Powrmatic OUH heaters are specification matched to Riello pressure jet oil burners. Heaters are arranged, as standard, for operation on lass D light distillate 35 second gas oil. Alternative kerosene (28 sec) or liquid biofuel firing available to order. All OUH heaters have the benefit of fire safety valve and oil filter (supplied loose). Air ovement reeblowing models are fitted with axial fan sets and discharge warmed air directly into the heated space via adjustable louvred horizontal grilles. entrifugal fan models are fitted with a centrifugal fan close-coupled directly to the heater casing. ontrols Heaters, as standard, are provided with high temperature limit protection as well as connections for both heat and, where applicable, fan only operation. Heaters may be connected to our compatible environmental control stations which are themselves available in two options. The Powtrol control station provides a digital timeswitch with mechanical day and frost protection thermostats and switching options to enable fan only operation for summer air movement. Alternatively heaters may be specified with a tamperproof digital control that features optimised start and stop (mandatory for A and high/low applications) which includes a digital time switch, electronic day thermostat and frost protection thermostat. Remote temperature sensor option available. Interconnecting wiring for all controls is the responsibility of the installer. All heaters have the ability to provide fan only summer air movement. 2

Duties OUH / OUH odel 20 30 45 60 Output kw 20 30 45 60 Input (nett V) kw 21.92 32.15 49.40 65.57 Volume m 3 /s 0.58 0.68 1.08 1.41 Airflow Throw OUH m 16 14 22 29 an Static OUH Pa 150 187 100 50 Supply Standard V/ph/Hz 230/1/50 Optional V/ph/Hz 415/3/50 otor kw 0.10 0.10 0.37 0.37 lectrics OUH Start amp 1.45 1.50 6.10 6.00 Run amp 0.82 0.86 2.00 2.60 otor kw 0.34 0.75 0.75 0.75 OUH Start amp 3.75 15.00 15.00 15.00 Run amp 2.60 7.00 7.00 7.00 uel Oil onnection BSP/Rc ¼ onsumption l/h 2.27 3.41 5.19 7.00 ounting Height OUH in m 2.50 3.00 ax m 3.00 5.00 Height mm 820 1102 1102 1102 Overall Width mm 555 780 780 780 Dimensions OUH mm 745 1030 1030 1030 Depth OUH mm 1085 1468 1468 1468 Top mm 1000 Installation learances Side mm 500 Rear mm 1000 lue diameter mm ø 100 125 ombustion Air Spigot mm ø 125 Noise Level - OUH models db(a) 42 50 48 49 Nett Weight OUH kg 62 126 126 126 OUH kg 69 142 142 142 Notes uel consumption and output figures based upon gross calorific values as - lass D light distillate fuel oil gross V 38.67 J/l (Nett 36.28 J/l) Heaters have efficiency levels which meet with the minimum efficiency requirements of UK PartL2B Building Regulations Heaters have efficiency levels which meet the criteria of the nhanced apital Allowance Scheme Air handling data is assessed at room ambient conditions Throw figures provide the distance to the point where the terminal velocity degrades to 0.25 m/s Noise levels refer to OUH axial fan models and measured 5m from appliance and in free field conditions otor kw, run and start amps apply to standard electrical supply as stated. or optional data contact sales ombustion air spigot is an optional extra Installer guidance notes on rear page 3

Dimensions OUH 20 - Axial an ø D A K B odel A B D H J K OUH 20 668 555 610 100 465 101 549 410 340 85 270 OUH 30/45/60 - Axial an ød A K B odel A B D H J K OUH 30 975 780 847 125 490 276 490 636 418 165 270 OUH 45 975 780 847 125 490 276 490 636 418 165 270 OUH 60 975 780 847 125 490 276 490 636 418 165 270 ontrols The OUH oil unit heater can be controlled using either our Powtrol or our 200bl controls. ultiple units can be controlled using our selection of RBR relay boxes. Powrtrol 200bl RBR Relay Box 4

Dimensions OUH 20 - entrifugal an ø D J 50 A L H B odel A B D H J K OUH 20 668 555 610 100 465 101 549 410 340 370 270 OUH 30/45/60 - entrifugal an ød J 50 A L H B odel A B D H J K OUH 30 975 780 847 125 490 276 490 636 418 494 270 OUH 45 975 780 847 125 490 276 490 636 418 494 270 OUH 60 975 780 847 125 490 276 490 636 418 494 270 lue omponent 100mm dia 125mm dia standard cowl 801101603 801121603 1500mm length n/a 801120153 970mm length 801100093 801120093 470mm length 801100043 801120043 938mm change over section 801105003 801125003 438mm change over section 801105103 801125103 297-466mm adjustable 801104403 801124403 447-700mm adjustable 801104503 801124503 locking band 801101803 801121803 45 elbow 801101003 801121003 90 elbow 801101203 801121203 omponent 100mm dia 125mm dia 90 tee 801100703 801120703 135 tee 801100603 801120603 tee cap 801100503 801120503 tee cap with drain 801100513 801120513 wall fixing bracket 801102304 801122304 wall support 801103204 801123204 support plate & clamp 801103504 801123504 storm collar c/w sealant 801102605 801122605 universal flashing ufc01400a ufc01400b high temperature flashing inc kit 800014026 800014026 wall band (s/s) - external ufc027100 ufc027125 5

Installer uide eneral The following notes are provided as a help, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. or copies of such manuals please consult our technical department or visit our website - www.powrmatic. co.uk Standards All Powrmatic OUH heaters must be installed, commissioned and operated with due regard to appropriate regulations, relevant odes of Practice, the possible requirements of Local Authorities, ire Officers and insurers as well as Powrmatic s installation manual. Position & Location Powrmatic OUH heaters can be drop rod suspended via purpose designed 10 suspension fixing points, attached to our optional wall support brackets or positioned on a level non-combustible base. In all cases it is important that all supporting structures have due regard to the relevant weight loadings. onsideration should also be given to flue routes and points of exit, oil, electrical and control connections, the throw characteristics of the heater, issues of public access and the siting of environmental control stations and/or remote temperature sensors where the position needs to be representative of the zone temperature to which they refer. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air or main fan circuits Areas where special consideration or advice may be required could include but is not limited to - where de-greasing solvents are present, even in minute concentrations where paint spraying is carried out where styrenes or other laminating products are used where airborne silicone is present where petrol engined vehicles are stored or maintained where dust is present (ie wood working or joinery shops) where high levels of extract persist Installation in such areas may be possible under specific conditions. Please consult our technical department for further information. Plant Room or nclosure Locations It is possible to install centrifugal fan variants of the OUH heater within plant rooms or enclosures however specific requirements may need to be applied. Such requirements cover the provision of positive ductwork connections as well as ventilation for combustion air and general plant room or enclosure ventilation. It is recommended that you consult with our technical department or the installation manual prior to installation. ombustion Air & eneral Ventilation Within the United Kingdom mandatory regulations may apply concerning the provision of combustion air and general heater ventilation. If the heater is installed directly within the heated space and where that heated space has a natural ventilation rate greater than 0.5 air changes per hour then combustion air and general heater ventilation is probably not required. If the heated space has a natural ventilation rate of less than 0.5 air changes per hour then either natural ventilator openings or mechanical ventilation will be required. Please consult the installation manual for further details. Installation learances Particular clearances may be necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. lue ach heater requires a separate flue system of the appropriate size. The flue should essentially be installed in the vertical plane and the number of bends kept to a minimum. The flue must be adequately supported and terminated with a suitable cowl, with due regard to the point of exit and it s proximity to any windows, doors or ventilation intakes etc. Pipework are should be taken when sizing pipework to ensure that maximum oil inlet pressures are not compromised under dynamic load conditions. Isolating valves and service unions should be provided for each heater and pipework installed with due regard for relevant standards and odes of Practice. uarantee Powrmatic heaters are provided with a comprehensive guarantee covering both the heater and the heat exchanger. or United Kingdom sales the heater has the benefit of a two year parts and one year labour guarantee whilst the heat exchanger assembly has a ten year time related warranty. All guarantees are subject to terms and conditions. Powrmatic Ltd Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Powrmatic Ireland 45 Broomhill lose Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: Telephone +353 0141 (0) 1452 887 0308 1764 ax 0141 887 6823 e-mail: email: info@cleangreenheating.com info@powrmatic.ie web: www.powrmatic.ie Powrmatic pursues a policy of continuous improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the ompany to confirm whether any material alterations have been made since publication of this brochure. Issue 2.0 - November 2011