Q7800H Integrated Burner Control Subpanel

Similar documents
7800 SERIES 22-Terminal Universal Subbase

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

RM7838A 7800 SERIES Relay Modules

RM7897A,C 7800 SERIES Relay Modules

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES S7830 Expanded Annunciator

7800 SERIES RM7888A Relay Module

RM7895A,B,C,D/EC7895A,C; RM7896A,C,D 7800 SERIES

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

RM7890D; RM7895E,F 7800 SERIES Relay Modules

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

RM7890; RM Vac 7800 SERIES Relay Modules

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

R7120M 7800 SERIES Relay Modules

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

7800 SERIES RM7888A Relay Module

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

APPLICATION SPECIFICATIONS INSTALLATION INSTRUCTIONS. The following assumptions apply when using the RM7840G,L, RM7800L, EC7840L:

Power Supply Display Module PSDM. Installation and Operation Manual

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Commercial/Industrial Combustion Control Level Three Announcement

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

IS Series Pressure Sensing Switches

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

7800 SERIES RM7840E,G,L,M Relay Module

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

LFL Series Burner Flame Safeguard Control

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

RA889A Switching Relay

Cleaver-Brooks CB780/CB784 Operation and Maintenance Manual

YP7899C SERIES Burner Management Panel

Schneider Electric Erie T155 Series

RM7890A1056, RM7890B SERIES

7800 SERIES EC7810A, EC7820A Relay Module

Interrupted Ignition Series Oil Primary Control

7800 SERIES RM7824A Relay Module

T4398A,B Precision Electric Heating Thermostat

T7079A,B Solid State Remote Temperature Controllers

BGH Series Hot Surface Ignition Control

7800 SERIES EC7823/RM7823 Relay Module

C6097A,B Pressure Switches

7800 SERIES EC7885A/RM7885A Relay Module

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

R7140G,L,M Burner Control Modules

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

RA889A Switching Relay

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

7800 SERIES S7800A2142 Keyboard Display Module

ELECTRONIC FIREPLACE DAMPER

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

INSTALLATION INSTRUCTIONS

ELECTRONIC FIREPLACE DAMPER

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

CR Series Command Relays

MBCE-110/230UV Flame Sensor Module

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

T874 Multistage Thermostat and Q674 Subbase

C554A Cadmium Sulfide Flame Detector

7800 Series RM7888A Relay Module

T834C Heating-Cooling Thermostat

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

PARAGON Commercial Refrigeration Controls

RA890G Protectorelay Primary Control

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

MANUAL RESET ALARM RELEASE

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

50A Integrated Furnace Control

Honeywell Primary Control Cross Reference

Q7300L Series 2000 Commercial Thermostat Subbases

Operator: Save these instructions for future use!

SV9520H SmartValve System Control Line Voltage Polarity Sense Models

Operator: Save these instructions for future use!

P7810A-D Pressuretrol Controller

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

T7200D,E Series 2000 Commercial Microelectronic Thermostats

50A Integrated Furnace Control

Installation Instructions

Operator: Save these instructions for future use!

LC3000 Level Controller Installation and Maintenance Instructions

! WARNING. Before using product, read and understand instructions.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ISIS SAFETY SYSTEM Installation guide

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Oil-Fired Furnace Single Stage Heat Pumps No- Auxiliary Heat. Electric Air Conditioning

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

Operator: Save these instructions for future use!

Deluxe Programmable Heat Pump Thermostat T8611M

Transcription:

Q7800H Integrated Burner Control Subpanel INSTALLATION INSTRUCTIONS FEATURES Unique subpanel design eliminates extensive wiring in the OEM control panel. One subpanel design covers multiple applications. Allows panel wiring before installation of relay modules. NEMA 1 enclosure. Access slots provided for electrical measurements. LED switch panel provides visual indication of burner sequence. LED switch panel provides auto/manual feature. SPECIFICATIONS APPLICATION The Q7800H Integrated Burner Control Subpanel is designed to eliminate much of the wiring required by the OEM to connect the 7800 SERIES control in their control panel. This should eliminate the potential for wiring errors. LED switch panel provides visual indication of burner sequence. The Q7800H has the following unique part numbers, with the application for each number provided: Q7800H1018: Single fuel, oil; Programmer Device. Q7800H1026: Single fuel, gas; Programmer Device. Q7800H1034: Dual fuel; Programmer Device. Q7800H1059: Single fuel. Q7800H1067: Dual fuel. Q7800H1091: Single fuel, oil. 50008378-001 LED Switch Assembly, Dual Fuel Modulation 50008378-002 LED Switch Assembly, Dual Fuel No Modulation 50008378-003 LED Switch Assembly, Single Fuel Modulation 50008378-004 LED Switch Assembly, Single Fuel No Modulation Electrical Ratings: Power: 120 Vac (+10%/-15%), 50/60 Hz (±10%). Environmental Ratings: Ambient temperature ranges: Operating: -40 F to +140 F (-40 C to +60 C). Storage: -40 F to +150 F (-40 C to +66 C). Humidity: 85% relative humidity, continuous, noncondensing. Vibration: 0.5G. Weight: Subbase PWA: 1 lb., 12 oz. (871 grams) Switch: 4 oz. (124 grams). Dimensions: See Fig. 1. Enclosure: NEMA 1. Approvals: U.S./Canadian Underwriters Laboratories, Inc. (UL) Component Recognized. 66-1158 03

Accessories Required by OEM: LED dome covers (number and color will vary): Suggested part number: Chicago Miniature Lamp, Inc.: 4341 Red 4343 Amber 4345 Green 4346 Blue Replacement Parts: Relays: The field-replaceable relays on the subbase panel must be replaced with the approved OMRON Part Number MY2-AC110/120S. Hold-down clip: OMRON Part Number PYC-P. CAUTION Equipment Damage Hazard. Use of the wrong relay can cause the relay to fail, creating a hazardous condition. Field-replaceable relays must be replaced with the specified part number. Failure to do so can result in a potentially hazardous condition. 10 (254) 8 (203) 1-7/8 (48) 5/8 (16) 9/16 (14) M22962 1-1/2 (38) Fig. 1. Q7800H Integrated Burner Control Subpanel, dimensions in in. (mm). 66-1158 03 2

8 (203) 4-7/8 (124) 7/8 (22) 1-1/16 (27) 1-1/4 (32) 9/16 (14) M22963 Fig. 2. Integrated Burner Control Subpanel Switch Assembly dimensions in in. (mm). INSTALLATION When Installing This Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced, flame safeguard service technician. 4. Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. 5. All wiring must comply with applicable local codes, ordinances, and regulations. 6. All wiring must be NEC Class 1 (Line Voltage). CAUTION Equipment Damage Hazard. Improper jumper configuration can result in incorrect operation and/or equipment damage. Device must be properly configured for the application by clipping and remove all appropriate jumpers. Improper configuration can result in a hazardous condition. 7. After installation is complete, check out product operation as provided in the applicable instructions. WARNING Electrical Shock Hazard. Can cause serious injury, death or property damage. Disconnect power supply before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. Follow the equipment manufacturer s instructions, if available; otherwise, proceed as follows below. 3 66-1158 03

8.000 (203) 9.750 (248) 10.000 (254) 6.8467 (175) 4.790 (122) 4.3467 (110)A 0.2500 1.1650 (6) (30) 0.700 (18) 1.2750 (32) 3.1683 (80) 4.6800 (119) 5.4583 (139) 7.7500 (197) M22964B Fig. 3. Enclosure mounting hole locations for the Q7800H1018, 1026, 1034, 1059, 1067, and 1091 Subbase Panel, dimensions in in. (mm). Mounting NOTE: For installation dimensions, see Fig. 1 through 4. 1. Place the subpanel in a location within the ambient temperature rating of the 7800 SERIES equipment being used. Refer to the appropriate Instructions. 2. The subpanel must be mounted in an appropriate metal enclosure with a low impedance connection to earth ground. See Fig. 3 and 4 for mounting hole locations. 3. Mount the subpanel in any position except horizontally with the bifurcated contacts pointing down. The standard vertical position is recommended. 4. Insert the mounting screws using recommended hardware, tightened securely. WIRING WARNING Electrical Shock Hazard. Can cause severe injury, death or property damage. Disconnect the power supply from the main disconnect before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. 66-1158 03 4

4.0950 (124) 7.750 (197) 0.3600 (9) 7.4200 (188) 5.9200 (150) 0.2300 (6) 8.0000 (203) 4.7000 (119) 3.4800 (88) 0.6800 (17) 1.2200 (31) 0.2000 (5) 3.4300 (87) 1.9800 (50) 0.2500 (6) 0.3550 (9) 1.3850 (35) 2.4800 (63) 3.5750 (91) 4.5400 (115) M22965A Fig. 4. Enclosure mounting hole and cutout locations for the 50008378 LED/Switch board, all versions, dimensions in in. (mm). 1. Provide overload protection and disconnect means as required. Disconnect the power supply from the main disconnect before beginning installation to prevent electrical shock and equipment damage. More than one disconnect may be involved. 2. All wiring must comply with appropriate electrical codes, ordinances and regulations. Use NEC Class 1 (Line Voltage) wiring. Wire used for main L1 connection to the subbase board must be minimum 14 AWG 90 C wire. 3. Check all the wiring circuits and complete a Static Checkout according to the 7800 SERIES Relay Module Specifications before installing the 7800 SERIES Relay Module on the subbase. 4. Install the 7800 SERIES Relay Module. 5. Restore power to the panel. NOTE: See Fig. 5 for a typical Q7800H installation. IMPORTANT Make sure no subpanel wiring is projecting beyond the terminal blocks. Tuck wiring in against the back of the subpanel so it does not interfere with the knife blade terminals or bifurcated contacts. 5 66-1158 03

ON OFF OIL OFF GAS POWER CALL FOR HEAT IGNITION ON FUEL ON ALARM LOW WATER MIN MAX MAN AUTO TM P14 P13 K2 K3 K4 P5 RM78XX K6 P7 P8 K5 P3 P4 F1 K8 K1 K7 P15 P9 P10 P11 P6 P2 P12 M22966 Fig. 5. Q7800H typical hookup. Table 1. Combinations for Terminals 8, 9, 10, and 21. Combination Number Pilot Fuel 8 Int. Pilot Valve 21 Ignition 10 Main 9 1 C No Load No Load F 2 B No Load No Load F 3 No Load B No Load F 4 F No Load A F 5 No Load F A F 6 D No Load A F 7 No Load D A F 8 D No Load A D 9 No Load D A D 66-1158 03 6

Table 2. Explanation of each Combination. A B C D F 4.5A ignition 50 VA Pilot Duty plus 4.5A ignition. 180 VA ignition plus motor valves with: 660 VA inrush, 360 VA open, 240 VA hold. 2A Pilot Duty. 65 VA Pilot Duty plus motor valves with: 3850 VA inrush, 700 VA open, 250 VA hold. Table 3. Q7800H Terminal Ratings (Primary Device). Terminal Number Description Ratings 1 Main power supply input. 120 Vac, (+10%/ -15%), 50 or 60 Hz (±10%) a 2 Additional L2 connections 3 System control switch connections 120 Vac, 8A run, 43A inrush 4 Operation control/common limit string 12o Vac, 8A run, 43A inrush connections 5 Additional fused L1 power outputs 120 Vac, limited by selected fuse and overall system load 6 and 7 Air Flow Switch connections 120 Vac, 8A run, 43A inrush 8 Burner motor power output 12o Vac, 9.8 AFL, 58.8 ALR (inrush) 9 Demand signal 120 Vac, 8A run, 43A inrush 10 Main oil valve power output 120 Vac b 11 Bypass oil valve output 120 Vac b 12 Alarm signal output 120 Vac, 1A pilot duty 13 Ignition output 4.5A ignition 14 Gas pilot valve power output 120 Vac b 15 Main gas valve power output 120 Vac b 16 7800 SERIES terminal 9 output 120 Vac b 17 7800 SERIES terminal 21 output 120 Vac b 18, 19, and 20 Modulation controller connections 120 Vac, 75 VA pilot duty 21, 22, and 23 Modulating motor connections 120 Vac, 75 VA pilot duty 24 and 25 Low fire start interlock connections 120 Vac, 8A run, 43A inrush 28 Hi-Lo controller input 120 Vac b 29 Auxiliary Gas Valve output 120 Vac b 32 and 34 Gas limit pressure connections 120 Vac, 8A run, 43A inrush 35 and 36 Oil pressure interlock connections 120 Vac, 8A run, 43A inrush 52 Oil select signal output 120 Vac, 60 ma 53 Gas select signal output 120 Vac, 60 ma 54 Auxiliary relay coil input 120 Vac, 12.5 ma 55, 56, and 57 Auxiliary relay pole 1:55-Common, 56-Normally 120 Vac, 10A open, 57-Normally closed 58, 59, and 60 Auxiliary relay pole 2: 58-Common, 59-Normally 120 Vac, 10A open, 60-Normally closed 61 K1 relay coil input 120 Vac, 12.5 ma 62 Tie point-no circuit board connection 120 Vac, 15A a 2000 VA maximum connected load to relay module assembly. b See Tables 1 and 2. These terminals can be connected to the 7800 SERIES subbase terminals 8, 9, 10, or 21, depending on the configuration. 7 66-1158 03

Table 4. Q7800H Terminal Ratings (Programmer Device). Terminal Number Description Ratings 1 Main power supply input. 120 Vac, (+10%/ -15%), 50 or 60 Hz (±10%) a 2 Additional L2 connections 3 System control switch connections 120 Vac, 8A run, 43A inrush 4 Operation control/common limit string connections 120 Vac, 8A run, 43A inrush 5 Additional fused L1 power outputs 120 Vac, limited by selected fuse and overall system load 6 and 7 Air Flow Switch connections 120 Vac, 8A run, 43A inrush 8 Burner motor power output 120 Vac, 9.8 AFL, 58.8 ALR (inrush) 9 Demand signal 120 Vac, 8A run, 43A inrush 10 Main oil valve power output 120 Vac b 12 Alarm signal output 120 Vac, 1A pilot duty 13 Ignition output 4.5A ignition 14 Pilot valve power output 120 Vac b 15 Safety gas valve power output 120 Vac b 16 7800 SERIES terminal 9 output 120 Vac b 17 7800 SERIES terminal 21 output 120 Vac b 18, 19, and 20 Modulation controller connections 120 Vac, 75 VA pilot duty 21, 22, and 23 Modulating motor connections 120 Vac, 75 VA pilot duty 24 and 25 Low fire start interlock connections 120 Vac, 1 ma 26 and 27 High Fire Purge interlock connections 120 Vac, 1 ma 30 Valve Proving Switch input 120 Vac, 1 ma 31 Valve Proving Demand input 120 Vac, 1 ma 32 and 34 Gas pressure limit connections 120 Vac, 8A run, 43A inrush 35 and 36 Oil pressure interlock connections 120 Vac, 8A run, 43A inrush 37 Pre-Ignition Interlock input 120 Vac, 1 ma 38 Gas Proof of Closure switch connection 120 Vac, 1 ma 39 Oil Proof of Closure switch connection 120 Vac, 1 ma 41 Low Water LED input connection 120 Vac, 20 ma 42 Air Compressor Interlock 120 Vac, 8A run, 43A inrush 43 Blower Interlock 120 Vac, 8A run, 43A inrush 44 Demand 120 Vac, 8A run, 43A inrush 45 Low Fire Hold Aquastat 120 Vac, 75 VA pilot duty 46 Remote Pump Control Output 120 Vac, 9.8 AFL, 58.8 ALR (inrush) 52 Oil select signal output 120 Vac, 60 ma 53 Gas select signal output 120 Vac, 60 ma 54 Auxiliary relay coil input 120 Vac, 12.5 ma 55, 56, and 57 Auxiliary relay pole 1:55-Common, 56-Normally open, 57-Normally closed 120 Vac, 10A a 2000 VA maximum connected load to relay module assembly. b See Tables 1 and 2. These terminals can be connected to the 7800 SERIES subbase terminals 8, 9, 10, or 21, depending on the configuration. U.S. Registered Trademark 2008 66-1158 03 K.K. Rev. 12-08