TECHNICAL SPECIFICATIONS

Similar documents
HEAT RECOVERY VENTILATOR

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Residential Heat & Energy Recovery

ENERGY RECOVERY VENTILATOR

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Limited Lifetime core warranty. 5-year warranty on balance of unit.

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Indoor Air Quality Product Brochure.

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators

Product Data HRV A10299

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

TECHNICAL SPECIFICATIONS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

TECHNICAL SPECIFICATIONS

Indoor Air Quality Product Brochure.

TECHNICAL SPECIFICATIONS

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

TECHNICAL SPECIFICATIONS

Product Data A05229 A05330 HRV

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Product Catalog Commercial Solutions US Edition

TECHNICAL SPECIFICATIONS

Product Catalog Commercial Solutions US Edition

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

MiniCore Ventilator (500, 1000) Series Engineering Guide

Total Recovery for ALL Climates Models TR & TRC

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

HRV/ERV Performance Issues

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

VERTICAL FAN COIL UNITS

TECHNICAL SPECIFICATIONS

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Energy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

COMMERCIAL VENTILATION

CATALOGUE Setting a new standard for energy efficient, clean air homes.

Tech to Tech May 07 HRV s & ERV s

TR Series - The Ultimate ERV

VENTILATION SYSTEMS. Model Numbers HRV-150 HRV-210 ERV-150 ERV-210

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

TECHNICAL SPECIFICATIONS

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

TECHNICAL SPECIFICATIONS

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Outside Air Requirements... SOLVED!

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

TECHNICAL SPECIFICATIONS

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Put the V back in HVAC

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

SAFETY AND INSTALLATION MANUAL MODEL 8100

Heat Recovery Ventilators models:

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

TECHNICAL SPECIFICATIONS

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Address of your installer

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph Fax:

Vertical Upflow Horizontal Left Air Handlers

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

Product Data. ERVCCSVA, ERVCCSHA Energy Recovery Ventilators STANDARD FEATURES ERVCCSVA ERVCCSHA

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Product Data ERVC. Energy Recovery Ventilators. Features

IAQ VENTILATION SOLUTIONS

Energy Recovery Ventilators

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

G6RC Series TECHNICAL SPECIFICATIONS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

IAQ VENTILATION SOLUTIONS

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

Heat Recovery Ventilation Systems OWNER S GUIDE

Heat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation

10-year industry best core warranty. 5-year warranty on balance of unit.

Ventilation Solutions IAQ Canada

Unit Features & Benefits RQPM/RQRM Series

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTION & OWNER S GUIDE

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Product Data. ERVCCLHA Energy Recovery Ventilators

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

HR150, 200; ER150, 200 Perfect Window Fresh Air Ventilation Systems

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Transcription:

TECHNICAL SPECIFICATIONS Energy Recovery Ventilator (ERV)

STANDARD 5 YEAR PARTS LIMITED WARRANTY When installed and registered with a complete Maytag system, this product carries a 12 Year All Parts Warranty. Product registration (by consumer or dealer) required for 12-year Warranty within a limited period of time after the installation. See current warranty document for details. This can be viewed at www.maytaghvac.com or ask your sales representative. The Maytag Energy Recovery Ventilator is an air-to-air heat exchanger designed to exhaust stale air and supply fresh air to the conditioned space. It recovers both latent and sensible heat from the exhaust air and transfers this heat to the supply air. The ERV is especially suited for dry homes using humidifiers during the heating season and for dry homes using air conditioning during the cooling season. It is available in 150 CFM and 210 CFM sizes. The Maytag ERV is recognized for unsurpassed quality and superior craftsmanship. It is guaranteed to satisfy the homeowner looking for durability, reliability, and performance. STANDARD FEATURES Exclusive convertible core from an ERV to an HRV. Integrated Balancing Dampers. All parts removable in 5 minutes. Defrost failure protection system designed to protect against damper malfunction Reinforced 20 Ga. pre-painted steel cabinet. Improved sliding system for core insertion Deeper one piece condensation tray to prevent water leakage. Aluminum framed foam filter. 1 inch fiberglass insulation. External electrical access on side panel. Aluminum foil and enthalpic media core. UL/CUL listed. HVI Certified. 2

MODEL IDENTIFICATION ERV _ 150 Energy Recovery Ventilator Air Flow in CFM DIMENSIONS ERV-150 6" (152mm) 30-1/4" (768mm) 13-3/4" (349mm) 20" (508mm) 2.5" (63mm) ERV-210 6" (152mm) 30-1/4" (768mm) 19" (483mm) 20" (508mm) Defrost 2.5" (63mm) Outside Temperature C ( F) Warmer Warmer than -5 C than 22 F -5 to -15 23 to 5-15 & colder 5 & colder Defrost Cycle Defrosting Min/ Operating Min. No defrost 6/32 See NOTE NOTE: The enthalpic core requires extra protection when the outside temperature drops below -15 C (5 F). Therefore, under these conditions, the unit will run 20 minutes at low speed, followed by 6 minutes in defrost and 34 minutes at off for every hour, until the exterior temperature becomes warmer. 3

SPECIFICATIONS Specifications and Ratings ERV-150 ERV-210 Assembled Weight with Core: 65 lbs 73 lbs Air Duct Connection: 6" diameter 6" diameter Exhaust Air Duct Connection: 6" diameter 6" diameter Drains: N/A N/ A Filter (size): 30 ppi washable reticulated foam 11.75"x12.87"x0.75" 30 ppi washable reticulated foam 11.75"x16.75"x0.75" Cabinet: Insulation: Mounting: and Exhaust Blower Motors: Recovery Core Surface Area: Recovery Core Material: 20 Ga. Pre-painted steel 1.00" aluminum foiled faced fiberglass and EPS (Expended Polystyren) Chain and hardware provided to suspend unit 120V/60Hz/1Ph 1/12 HP RPM: 1660/1300/1050 sleeved bearings PSC Type 116 sqft Aluminum foil and enthalpic transfer media (paper) 20 Ga. Pre-painted steel 1.00" aluminum foiled faced fiberglass and EPS (Expended Polystyren) Chain and hardware provided to suspend unit 120V/60Hz/1Ph 1/7 HP RPM: 1660/1300/1050 sleeved bearings PSC Type 156 sqft Aluminum foil and enthalpic transfer media (paper) ELECTRICAL DATA Models ERV-150 ERV-210 Voltage/Hertz/Phase 120/60/1 120/60/1 Maximum Fuse Size (Amp) Branch Circuit 15A 15A Control Circuit Voltage 5V DC 5V DC NORDYNE Part Number 918713 918714 ACCESSORIES Description NORDYNE Part Number Basic Wall Control HRV/ERV Maytag 918738 Electronic Wall Control HRV/ERV Maytag 918739 Push Button 20/40/60 HRV/ERV Maytag 918740 Air Intake 6D X 9 X 9 With Duct 918722 Balancing Kit 0.5" H20 918723 4

PERFORMANCE ERV-150 VENTILATION PERFORMANCE ERV-150 External Static Pressure Pa in. w.g. I/s cfm I/s cfm I/s cfm 25 0.1 81 173 87 184 93 197 50 0.2 78 165 83 175 86 182 75 0.3 72 152 76 162 80 169 100 0.4 67 142 71 151 77 163 125 0.5 55 117 59 124 67 143 150 0.6 46 98 49 104 56 118 175 0.7 36 77 39 82 41 87 200 0.8 30 63 32 67 24 51 Note: Unit operating at maximum speed. 225 200 Net Airflow Gross Air Flow Exhaust External Static Pressure - Pascals (250 Pascals = 1" of water) 175 150 125 100 75 50 25 (l/s) Exhaust (l/s) 0 0 25 50 75 100 125 150 Gross Airflow - l/s (0.47 l/s = 1 cfm) 5

PERFORMANCE ERV-150 ENERGY PERFORMANCE ERV-150 Temperature Net Airflow Average Power Sensible Recovery Efficiency Apparent Sensible Effectiveness Latent Recovery Moisture Transfer C F I/s cfm Watts % % 0 32 29 60 56 71 79 0.52 Heating 0 32 47 100 80 64 73 0.41 0 32 65 137 126 60 68 0.36-15 5 31 65 64 56 81 0.41 Total Recovery Efficiency Cooling 35 95 28 59 52 45 100 90 80 Apparent (%) Net (%) Efficiency 70 60 50 40 0 25 50 75 100 Airflow (l/s) 6

PERFORMANCE ERV-210 VENTILATION PERFORMANCE ERV-210 External Static Pressure Pa in. w.g. I/s cfm I/s cfm I/s cfm 25 0.1 109 231 116 245 128 271 50 0.2 107 228 114 241 123 260 75 0.3 101 214 107 227 118 249 100 0.4 95 201 101 213 110 233 125 0.5 86 182 91 193 103 217 150 0.6 79 167 83 177 92 195 175 0.7 62 132 66 140 81 172 200 0.8 40 85 43 90 55 116 Note: Unit operating at maximum speed. Net Airflow Gross Airflow Exhaust 225 200 External External Static Static Pressure - - Pascals Pascals (250 (250 Pascals Pascals = 1" 1" of of water) water) 175 150 125 100 75 50 25 (l/s) Exhaust (l/s) 0 0 25 50 75 100 125 150 Gross Airflow - l/s (0.47 l/s = 1 cfm) 7

PERFORMANCE ERV-210 ENERGY PERFORMANCE ERV-210 Temperature Net Airflow Average Power Sensible Recovery Efficiency Apparent Sensible Effectiveness Latent Recovery Moisture Transfer C F I/s cfm Watts % % 0 32 29 60 56 71 79 0.52 Heating 0 32 47 100 80 64 73 0.41 0 32 65 137 126 60 68 0.36-15 5 31 65 64 56 81 0.41 Total Recovery Efficiency Cooling 35 95 28 59 52 45 100 Efficiency 90 80 70 60 Apparent (%) Net (%) 50 40 0 25 50 75 100 Airflow - l/s Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license. 863B-0207 (Replaces 863B-0205) Printed in U.S.A. (02/07)