Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9.

Similar documents
Thank you for selecting LENNOX air conditioners.

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Air Conditioner Service Manual

Change for Life. Service Manual

TECHNICAL GUIDE MODELS: DCMF/DHMF LX SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 16 SEER 1 PHASE 3/4 THRU 2 NOMINAL TONS DESCRIPTION

Artful Inverter. Introduction and Features. Model. Remarks

Change for Life. Service Manual GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

13SEER DC INVERTER 24K

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

TECHNICAL GUIDE MODELS: INDOOR-DHPM/OUTDDOR-DHMF LX SERIES DUCTLESS MULTI-ZONE SPLIT HEAT PUMPS 16 SEER 1 PHASE 1.5 THRU 3.5 NOMINAL TONS DESCRIPTION

Submittal Data Sheet

Part Ⅰ : Technical Information

GWH09QB-K3DNC6D GWH12QB-K3DNA1D GWH12QB-K3DNA2D GWH12QB-K3DNA3D GWH12QB-K3DNA6D GWH12QB-K3DNB2D GWH12QB-K3DNB4D GWH12QB-K3DNB6D GWH12QB-K3DNB8D

Service Manual "P" SERIES 30K - 36K 220V INVERTER-DRIVEN AIR CONDITIONING UNITS IMPORTANT:

Air Conditioner Service Manual

2014 Equipment Catalog

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

High Heat COP. High/Low Stage

manuflow AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Service Manual & Installation Manual

Service Manual. Model: ACZEM4C4R18/ACZCI4C4R18 ACZEM4H4R18/ACZCI4H4R18 ACZEM4C4R24/ACZCI4C4R24 ACZEM4H4R24/ACZCI4H4R24 (Refrigerant:R410A)

Unit Features & Benefits RQPM/RQRM Series

Service Manual & Installation Manual

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

[U] Serie MOV. Manual de Ingeniería

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Service Manual. MODEL: GWC09KF-K3DNA5A GWH09KF-K3DNA5A GWC12KF-K3DNA5A GWH12KF-K3DNA5A (Refrigerant R-410A) GREE ELECTRIC APPLIANCES,INC.

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

DESIGN & TECHNICAL MANUAL

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

SERVICE MANUAL. Split Air Conditioner Arctic Series mod. A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

ROOFTOP PACKAGE (GC201105) TECHNICAL SALES GUIDE-50&60Hz CAPACITY RANGE:3~30TON SUPER HIGH AMBIENT OPERATION TO 55


CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

1 Summary and features. Service Manual. Model QSVMI-09A QSVMI-12A QSVMI-18A

Geniuses at work. Residential Mini Splits

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

Change for life. Service Manual GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

DESHUMIDIFIER MH-V5 Service manual

Commercial High-Efficiency Condensing Units

Samsung 360 Cassette, Single Zone, Split System

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

Ductless Split Systems Concealed Duct Heat Pumps

Floor-Standing Type(E Series)

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

2017 LINE UP MINI SPLITS CATALOG

Air Conditioner SVC MANUAL(Exploded View)

2017 LINE UP MINI SPLITS CATALOG

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Ceiling & Floor type Unit

Mini Split Air Conditioners and Heat Pump

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

WJH4 Product Specifications

[U] Serie MHB / MHA Manual de Ingeniería

1. Features Specification Dimensions Refrigeration cycle diagram Operation limits

High Wall Duct-Free High Efficiency Single Zone

K sin. Mini Split Air Conditioners and Heat Pump

Specifications, Performance & Submittal

Service Manual "X" SERIES 18K - 24K - 208/230V INVERTER-DRIVEN AIR CONDITIONING UNITS PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

Transcription:

Specifications (Model) KSIB009-H116 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Efficiency COOLING KSIB009-H116 115V HEATING 60HZ 31002500 (W) 38002750 (W) 106009000(Btuh) 130009500(Btuh) 1250730 1450840 1250 1450 12 13.6 323 1.2 SEER 16 HSPF 9.5 Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) KSIB009-H116 high 1200 mid 1060 low 700 13 1.0 0.18 Cross flow fan 1 Φ 3,8 X 22,9 Φ 7 mm 26.8 12.7 1.49 MP28VA 2 Controller3.15 transformer0.2 43 37 30 53 47 40 30.3 7.5 9.8 32.6 11.6 13.0 18.7 27.5

(Model) KSIB009-H116 Outdoor Model of Outdoor Unit KSIB009-H116 Compressor Manufacturertrademark SANYO Compressor Model C-6RZ092H1AB Compressor Type Twin rotory L.R.A. (A) 33 Compressor RLA(A) 3.92 Compressor Power Input(W) 960 Overload Protector Int11l-3979 Throttling Method Capillary throttling Starting Method Transducer starting Working Temp Range ºF 5 < T < 110 (-15 C < T < 43 C) Condenser Rows-Fin Gap(mm) Φ 9.52 25.3 X 20 X 1.7 Fan Motor Speed (rpm) 830 ± 20 Output of Fan Motor (W) 30 0.3 2.5 Air Flow Volume of Outdoor Unit (cfm) 1058 Axial fan 1 Fan Diameter (in) 15.7 Defrosting Method Auto defrost Climate Type T1 Isolation I Moisture Protection IP24 Pressure for the Discharge Side(MPa) 551 Pressure for the Suction Side(MPa) Sound Pressure Level db (A) 174 53 Sound Power Level db (A) Dimension of Package (WDH)( in) 63 33.3 X 12.6 X 21.2 34.5 X 14.1 X 23.2 8899 Refrigerant Charge (lbs) R410A 2.6 Connection Pipe Length (ft) 25 Gas additional charge (ounceft) 0,16 Outer Liquid Pipe (in) 14 Diameter Gas Pipe (in) ½ Max Distance Height (m) Length (m) 20 Container 95 Loading Quantity 40 Container 198 40 High Cube Container 225

Specifications (Model) KSIB012-H116 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) COOLING KSIB012-H116 115V 60HZ HEATING 41003500 (W) 44003850 (W) 1400012000(Btuh) 1500013000(Btuh) 14501100 15501200 1450 1550 13.6 14.5 323 1.2 Efficiency SEER 16 HSPF 9.5 Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) KSIB012-H116 high 1350 mid1200 low 1100 20 4.0 0.28 Cross flow fan 1 3.6 24.2 7 mm 26.8 12.7 1.49 MP28VA 2 Controller3.15 transformer 0.2 43 37 30 53 47 40 32.6 8.8 11.2 34.4 12.3 14.6 24.2 30.8

(Model) KSIB012-H116 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(mm) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) 15.7 Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(MPa) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB012-H116 SANYO C-6RZ092H1AB Twin rotory 33 3.92 960 Int11l-3979 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 25.3 X 20 X 1.7 830 ± 20 30 0.3 2.5 1800 Axial fan 1 Auto defrost T1 IP24 551 174 55 65 33.3 X 12.6 X 21.2 34.5 X 14.1 X 23.2 8899 R410A 2.8 Connection Pipe Loading Quantity Length (ft) Gas additional charge (ounceft) Outer Liquid Pipe (in) Diameter Gas Pipe (in) Max Height (m) Distance Length (m) 20 Container 40 Container 40 High Cube Container 25 0.16 14 ½ 91 180 214

Specifications (Model) KSIB012-H216 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (mm) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) COOLING KSIB012-H216 208V230V 60HZ HEATING 41003500 (W) 44003850 (W) 1400012000(Btuh) 1500013000(Btuh) 14501100 15001200 1700 1750 7.4 7.6 353 1.2 Efficiency SEER 16 HSPF 9.5 B KSIB012-H216 mid1200low1110 22 1.0 0.152 Cross flow fan 1 3.6 24.2 7 mm 26.8 12.7 1.49 MP28EA 2 Controller3.15 transformer0.2 43 40 39 53 50 49 32.6 8.8 11.2 34.4 12.3 14.6 24.2 33

(Model) KSIB012-H216 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(mm) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) 15.7 Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(MPa) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB012-H216 SANYO C-6RZ092H1AB Twin rotory 33 3.92 960 Int11l-3979 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 25.3 X 20 X 1.7 830±20 30 0.3 2.5 1800 Axial fan 1 Auto defrost T1 I IP24 551 174 55 65 33.3 X 12.6 X 21.2 34.5 X 14.1 X 23.2 8899 R410A 2.8 Connection Pipe Length (ft) Gas additional charge (ounceft) 25 0.16 Outer Diameter Liquid Pipe (in) Gas Pipe (in) 14 ½ Max Height (m) Distance Length (m) 20 Container 91 Loading Quantity 40 Container 40 High Cube Container 189 215

Specifications (Model) KSIB018-H216 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) COOLING KSIB018-H216 208 V230V HEATING 60HZ 5300 5800 18000 20000 1350 1800 2440 2440 10.6 10.6 Efficiency SEER 16 HSPF 8.5 A KSIB018-H216 470 1.2 135012501150 20 1.0 0.09 Cross flow fan 1 3.8 X 31.3 7 mm 2-1.6 30.7 X 13.3 X 0.99 MP24GA 2 PCB 3.15A Transformer 0.2A 504744 605754 40.1 X 9 X 12.2 42.4 X 12.8 X 15.3 28.6 37.4

(Model) KSIB018-H216 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(mm) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(MPa) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB018-H216 SANYO EU1013DD Scroll 27 6.54 1266 4CYC11233 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 2-1.5 28.7 X 25.9 X 1.7 High780±20 rmin Low620±35 rmin 60 0.3 3 Axial fan 1 18.1 Auto defrost T1 I IP24 551 174 57 67 37.3 X 13.4 X 26.9 43.2 X 17.7 X 29.7 129.8 140.8 R410A 3.9 Connection Pipe Loading Quantity Length (ft) Gas additional charge (ounceft) Outer Liquid Pipe (in) Diameter Gas Pipe (in) Max Height (m) Distance Length (m) 20 Container 40 Container 40 High Cube Container 25 0,24 38 58 8 15 56 116 136

Specifications (Model) KSIB024-H216 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) KSIB024-H216 COOLING HEATING 208-230V~ 25 100 82 25 100 85 2250 6400 6150 1800 8000 6800 7680 21800 21000 6150 27300 23200 450 2350 2050 540 3350 2400 3200 3350 14.0 14.2 470 412 353 2.4 Efficiency SEER 16 HSPF 8.5 16 SEER KSIB024-H216 1400 1200 1100 45 3.0 0.2 Cross flow fan 1 3.8 X 31.3 7 mm 2-1.6 30.9 X 15.7 X 0.99 MP28AA 2 PCB 3.15A Transformer 0.2A 474340 575350 40.1X 12.2 X 9 42.4X 12.8 X 15.3 28.6 37.4

(Model) KSIB024-H216 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(in) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(psi) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB024-H216 SANYO C-6RZ146H1B Twin Rotory 32 7.78 1500 1NT11L-3979 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 0.07873-0.055 28.77X32X1.732 780 620 120 0.30 2.0 Axial fan 1 18.1 Auto defrost T1 I IP24 551 174 5855 6865 37.3 X 33 X 16.5 43.2 X 17.7 X 35.6 149.6 160.6 R410a 5.3 Connection Pipe Loading Quantity Length (ft) Gas additional charge (ounceft) Outer Liquid Pipe (in) Diameter Gas Pipe (in) Max Height (m) Distance Length (m) 20 Container 40 Container 40 High Cube Container 25 0.32 38 58 50 100 116