Specifications (Model) KSIB009-H116 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Efficiency COOLING KSIB009-H116 115V HEATING 60HZ 31002500 (W) 38002750 (W) 106009000(Btuh) 130009500(Btuh) 1250730 1450840 1250 1450 12 13.6 323 1.2 SEER 16 HSPF 9.5 Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) KSIB009-H116 high 1200 mid 1060 low 700 13 1.0 0.18 Cross flow fan 1 Φ 3,8 X 22,9 Φ 7 mm 26.8 12.7 1.49 MP28VA 2 Controller3.15 transformer0.2 43 37 30 53 47 40 30.3 7.5 9.8 32.6 11.6 13.0 18.7 27.5
(Model) KSIB009-H116 Outdoor Model of Outdoor Unit KSIB009-H116 Compressor Manufacturertrademark SANYO Compressor Model C-6RZ092H1AB Compressor Type Twin rotory L.R.A. (A) 33 Compressor RLA(A) 3.92 Compressor Power Input(W) 960 Overload Protector Int11l-3979 Throttling Method Capillary throttling Starting Method Transducer starting Working Temp Range ºF 5 < T < 110 (-15 C < T < 43 C) Condenser Rows-Fin Gap(mm) Φ 9.52 25.3 X 20 X 1.7 Fan Motor Speed (rpm) 830 ± 20 Output of Fan Motor (W) 30 0.3 2.5 Air Flow Volume of Outdoor Unit (cfm) 1058 Axial fan 1 Fan Diameter (in) 15.7 Defrosting Method Auto defrost Climate Type T1 Isolation I Moisture Protection IP24 Pressure for the Discharge Side(MPa) 551 Pressure for the Suction Side(MPa) Sound Pressure Level db (A) 174 53 Sound Power Level db (A) Dimension of Package (WDH)( in) 63 33.3 X 12.6 X 21.2 34.5 X 14.1 X 23.2 8899 Refrigerant Charge (lbs) R410A 2.6 Connection Pipe Length (ft) 25 Gas additional charge (ounceft) 0,16 Outer Liquid Pipe (in) 14 Diameter Gas Pipe (in) ½ Max Distance Height (m) Length (m) 20 Container 95 Loading Quantity 40 Container 198 40 High Cube Container 225
Specifications (Model) KSIB012-H116 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) COOLING KSIB012-H116 115V 60HZ HEATING 41003500 (W) 44003850 (W) 1400012000(Btuh) 1500013000(Btuh) 14501100 15501200 1450 1550 13.6 14.5 323 1.2 Efficiency SEER 16 HSPF 9.5 Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) KSIB012-H116 high 1350 mid1200 low 1100 20 4.0 0.28 Cross flow fan 1 3.6 24.2 7 mm 26.8 12.7 1.49 MP28VA 2 Controller3.15 transformer 0.2 43 37 30 53 47 40 32.6 8.8 11.2 34.4 12.3 14.6 24.2 30.8
(Model) KSIB012-H116 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(mm) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) 15.7 Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(MPa) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB012-H116 SANYO C-6RZ092H1AB Twin rotory 33 3.92 960 Int11l-3979 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 25.3 X 20 X 1.7 830 ± 20 30 0.3 2.5 1800 Axial fan 1 Auto defrost T1 IP24 551 174 55 65 33.3 X 12.6 X 21.2 34.5 X 14.1 X 23.2 8899 R410A 2.8 Connection Pipe Loading Quantity Length (ft) Gas additional charge (ounceft) Outer Liquid Pipe (in) Diameter Gas Pipe (in) Max Height (m) Distance Length (m) 20 Container 40 Container 40 High Cube Container 25 0.16 14 ½ 91 180 214
Specifications (Model) KSIB012-H216 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (mm) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) COOLING KSIB012-H216 208V230V 60HZ HEATING 41003500 (W) 44003850 (W) 1400012000(Btuh) 1500013000(Btuh) 14501100 15001200 1700 1750 7.4 7.6 353 1.2 Efficiency SEER 16 HSPF 9.5 B KSIB012-H216 mid1200low1110 22 1.0 0.152 Cross flow fan 1 3.6 24.2 7 mm 26.8 12.7 1.49 MP28EA 2 Controller3.15 transformer0.2 43 40 39 53 50 49 32.6 8.8 11.2 34.4 12.3 14.6 24.2 33
(Model) KSIB012-H216 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(mm) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) 15.7 Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(MPa) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB012-H216 SANYO C-6RZ092H1AB Twin rotory 33 3.92 960 Int11l-3979 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 25.3 X 20 X 1.7 830±20 30 0.3 2.5 1800 Axial fan 1 Auto defrost T1 I IP24 551 174 55 65 33.3 X 12.6 X 21.2 34.5 X 14.1 X 23.2 8899 R410A 2.8 Connection Pipe Length (ft) Gas additional charge (ounceft) 25 0.16 Outer Diameter Liquid Pipe (in) Gas Pipe (in) 14 ½ Max Height (m) Distance Length (m) 20 Container 91 Loading Quantity 40 Container 40 High Cube Container 189 215
Specifications (Model) KSIB018-H216 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) COOLING KSIB018-H216 208 V230V HEATING 60HZ 5300 5800 18000 20000 1350 1800 2440 2440 10.6 10.6 Efficiency SEER 16 HSPF 8.5 A KSIB018-H216 470 1.2 135012501150 20 1.0 0.09 Cross flow fan 1 3.8 X 31.3 7 mm 2-1.6 30.7 X 13.3 X 0.99 MP24GA 2 PCB 3.15A Transformer 0.2A 504744 605754 40.1 X 9 X 12.2 42.4 X 12.8 X 15.3 28.6 37.4
(Model) KSIB018-H216 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(mm) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(MPa) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB018-H216 SANYO EU1013DD Scroll 27 6.54 1266 4CYC11233 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 2-1.5 28.7 X 25.9 X 1.7 High780±20 rmin Low620±35 rmin 60 0.3 3 Axial fan 1 18.1 Auto defrost T1 I IP24 551 174 57 67 37.3 X 13.4 X 26.9 43.2 X 17.7 X 29.7 129.8 140.8 R410A 3.9 Connection Pipe Loading Quantity Length (ft) Gas additional charge (ounceft) Outer Liquid Pipe (in) Diameter Gas Pipe (in) Max Height (m) Distance Length (m) 20 Container 40 Container 40 High Cube Container 25 0,24 38 58 8 15 56 116 136
Specifications (Model) KSIB024-H216 Model Function Rated Voltage Frequency(Hz) (Standard *) Total Capacity (W) (HighStandard *): Total Capacity (Btuh) (High Standard *): Power Input (W) (High Standard*) Rated Input (W) ( Standard *) Rated Current (A) ( Standard *) Air Flow Volume (cfm) Dehumidifying Volume (lh) Indoor Model of Indoor Unit Fan Motor Speed (rpm) (HML) Output of Fan Motor (w) Input Power of Heater (w) Diameter-Length (in) Evaporator Row-Fin Gap(mm) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (HML) Sound Power Level db (A) (HML) Dimension of Package (WDH)(in) KSIB024-H216 COOLING HEATING 208-230V~ 25 100 82 25 100 85 2250 6400 6150 1800 8000 6800 7680 21800 21000 6150 27300 23200 450 2350 2050 540 3350 2400 3200 3350 14.0 14.2 470 412 353 2.4 Efficiency SEER 16 HSPF 8.5 16 SEER KSIB024-H216 1400 1200 1100 45 3.0 0.2 Cross flow fan 1 3.8 X 31.3 7 mm 2-1.6 30.9 X 15.7 X 0.99 MP28AA 2 PCB 3.15A Transformer 0.2A 474340 575350 40.1X 12.2 X 9 42.4X 12.8 X 15.3 28.6 37.4
(Model) KSIB024-H216 Outdoor Model of Outdoor Unit Compressor Manufacturertrademark Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ºF Condenser Rows-Fin Gap(in) Fan Motor Speed (rpm) Output of Fan Motor (W) Air Flow Volume of Outdoor Unit (cfm) Fan Diameter (in) Defrosting Method Climate Type Isolation I Moisture Protection Pressure for the Discharge Side(psi) Pressure for the Suction Side(MPa) Sound Pressure Level db (A) Sound Power Level db (A) Dimension of Package (WDH)( in) Refrigerant Charge (lbs) KSIB024-H216 SANYO C-6RZ146H1B Twin Rotory 32 7.78 1500 1NT11L-3979 Capillary throttling Transducer starting 5 < T < 110 (-15 C < T < 43 C) Φ 9.52 0.07873-0.055 28.77X32X1.732 780 620 120 0.30 2.0 Axial fan 1 18.1 Auto defrost T1 I IP24 551 174 5855 6865 37.3 X 33 X 16.5 43.2 X 17.7 X 35.6 149.6 160.6 R410a 5.3 Connection Pipe Loading Quantity Length (ft) Gas additional charge (ounceft) Outer Liquid Pipe (in) Diameter Gas Pipe (in) Max Height (m) Distance Length (m) 20 Container 40 Container 40 High Cube Container 25 0.32 38 58 50 100 116