technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Similar documents
technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air Conditioners. Technical Data FTXS-G

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air Conditioners Technical Data

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

technical data air conditioning systems Indoor Units FCQ-C8VEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioners Technical Data

Air Conditioners Technical Data

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Air Conditioners. Technical Data FTY-H

Air Conditioners Technical Data

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

Air Conditioners Technical Data

Heating. Technical Data EEDEN ERRQ-AY1

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data EEDEN AZQS-BV1

Daikin air conditioners for your home, shops, restaurants and offices

EEDEN technical data EKRTR. Altherma. Altherma

AIR CONDITIONERS, HEATING & COOLING for your home

Fan Coil Units. Technical Data FWC-BT/BF

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

for small rooms in multi application

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

TABLE OF CONTENTS RMXS-E8V1B

Air Conditioners. Technical Data RZQG-L

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

technical data Fan coil unit FWB small duct unit

Air conditioners, heating & cooling for shops,restaurants and offices

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Daikin air conditioners for your home

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Air conditioners, heating & cooling for the retailmarket and offices

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-B

Air Purifiers. Technical Data MC70L

Daikin air conditioners for your home

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

w w w. d a i k i n. e u ATXS-E

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

for your home FLXS-B Flexi type unit air to air heat pumps

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

EEDEN technical data ERHQ AA. Altherma. Altherma

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

TABLE OF CONTENTS ERSQ-AAY1

Daikin air conditioners for your home

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

for the retail market, hotels, restaurants and offices

Air Conditioner SVC MANUAL(Exploded View)

DAIKIN Air Handling Unit Modular

Chillers. Technical Data. EWYD-BZ 250~580 kw

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioning Technical Data RZAG-MV1

Daikin air conditioners for shops, restaurant and offices

Air Conditioners Heating & Cooling

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Pure comfort & design

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN ABQ-A

BENEFIT FROM LOWER FUEL COSTS.

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioners Heating & Cooling

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Air Conditioning Technical Data RZASG-MV1

for your home FTXS-G WALL MOUNTED UNIT

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

Air conditioners Cooling only

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

Air Conditioners Heating & Cooling

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

Transcription:

technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air

Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features............................................................. 2 2 Specifications....................................................... 3 For indoor units only................................................. 3 Technical Specifications............................................. 3 Electrical Specifications............................................. 4 3 Dimensional drawing & centre of gravity........................ 5 Dimensional drawing................................................. 5 Centre of gravity..................................................... 6 4 Piping diagram...................................................... 8 5 Wiring diagram...................................................... 9 Wiring diagram....................................................... 9 6 Sound data......................................................... 10 Sound pressure spectrum........................................... 10 7 Fan characteristics................................................ 11 Split Sky Air Indoor Units 1

t i y n k r t o - i o 0 l d 1 pn 4 FI Indoor Units R410A FDKS-CVMB 1 Features UB S M V C a S K D RS Extremely quiet in operation You have the choice out of 3 fan speeds to select 1 Daikin s special dry programme reduces humidity in the room without variation in room temperature Powerful mode can be selected for rapid cooling Night set mode saves energy by preventing overcooling or overheating during night time Standard suction filter: removes airborne dust particles to ensure a steady supply of clean air Compact dimensions, can easily be mounted in a ceiling void of only 240mm Daikin remote controls give you easy control at your fingertips. optional 5 steps standard 2 Split Sky Air Indoor Units

2 Specifications Indoor Units R410A FDKS-CVMB 2-1 FOR INDOOR UNITS ONLY FDKS50CVMB FDKS60CVMB Nominal Input Cooling kw 0.140 0.160 3 2-2 TECHNICAL SPECIFICATIONS FDKS50CVMB FDKS60CVMB Dimensions Packing Height mm 266 266 Width mm 1106 1306 Depth mm 751 751 Unit Height mm 20 200 Width mm 900 1100 Depth mm 620 620 Weight Unit kg 27.0 30.0 Packed Unit kg 34.0 37.0 Heat Dimensions Length mm 700 900 Exchanger Nr of Rows 3 2 Fin Pitch mm 1.50 1.50 Nr of Stages 12 12 Tube type Hi-XSS (7) Fin Type ML fin (Multi louver) Fan Type Sirocco fan Air Flow Rate Cooling High m³/min 12.0 16.0 Medium m³/min 11.0 14.8 Low m³/min 10.0 13.5 Silent m³/min 8.4 11.2 Operation Fan Max Standard Pa 40 40 Motor 1 1 Model 130J-23 Number of steps 5 steps, silent and auto Motor Speed High rpm 1270 1280 (cooling) Medium rpm 1180 1160 Low rpm 1080 1040 Silent rpm 930 890 Operation Fan Motor Output W 130 130 (high) Cooling Sound Power High dba 55.0 56.0 Sound High dba 37.0 38.0 Pressure Medium dba 35.0 36.0 Low dba 33.0 34.0 Silent Operation dba 31.0 32.0 Refrigerant Type R-410A Piping Liquid (OD) Diameter mm 6.4 6.4 connections (OD) Gas Diameter (OD) mm 12.7 12.7 Drain Diameter mm I.D. 20/O.D. 26 (OD) Heat Insulation Both liquid and gas pipes Air Filter Removable/washable/Mildew proof Air direction control Left, right, up and downwards Temperature control Microcomputer control 2 Split Sky Air Indoor Units 3

2 Specifications Indoor Units R410A FDKS-CVMB 2 2-2 TECHNICAL SPECIFICATIONS FDKS50CVMB FDKS60CVMB Standard Installation manual Accessories 1 pc Operation manual 1 pc Infrared remote control 1 pc Batteries 2 pcs Remote control holder 1 pc Fixing screw for remote control 2 pcs Signal receiver cover kit 1 set Insulation for fitting 1 set Sealing pad 1 set Clamp metal 1 pc Drain hose 1 pc Washer for hanger bracket 8 pcs Sealing material 2 pcs Clamps 6 pcs Washer fixing plate 4 pcs Screws for duct flanges 1 set Air filter 1 pc Notes Sound values are measured in an anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. 2-3 ELECTRICAL SPECIFICATIONS FDKS50CVMB FDKS60CVMB Power Supply Name VM Phase 1 1 Frequency Hz 50/60 Voltage V 220-240/220-230 Current Nominal Cooling A 0.64 0.74 running current (RLA) Wiring For Power 3 3 connections Supply Remark 4 for interunit wiring (included earth wiring) Voltage range Minimum -10% Maximum +10% Power Supply Intake Outdoor unit only 4 Split Sky Air Indoor Units

Indoor Units R410A FDKS-CVMB 3 Dimensional drawing & centre of gravity 3-1 Dimensional drawing FDK/XS50C 300 or more (Service space) unit (mm) Signal transmitter (Suspension bolt pitch) 20 or more 20 or more 400 or more (In case bottom-suction) 240 or more Ceiling Infrared remote control FDXS - - C(A)VMB: (ARC433A7) FDKS - - C(A)VMB: (ARC433A8) 3 22-J4.7 Hole (Service space) Operation lamp Room temp. sensor (Suspension bolt pitch) Allow view A Inspection door (ceiling opening) Timer lamp Indoor unit ON/OFF switch Home leave lamp Signal receiver 16-M5 holes Infrared receiver unit Cord (length: 1900mm) 18-M4 Holes 20-M5 Holes Notes: 1. In case of back-suction, mount chamber cover to bottom side of the unit. In case of bottom-suction, mount chamber cover to back side of the unit. 2. Location of unit s name plate: control box cover. (unit: mm). 3. Mount the air filter at the suction side. (select its colorimethod (gravity method) 50% or more). It can not be equipped with air filter (accessory) when connecting duct to suction side. 4. Pipe specification In case of back suction 1 Liquid pipe connection J6.4 (Flare connection) 2 Gas pipe connection NOTE) 4. 3 Socket for drain VP20 (O.D. J26 / I.D. J20) 4 Drain hose (accessory) I.D. J 25 (Outlet) 5 Control box 6 Infrared receiver unit connection 7 Power supply connection 8 Suspension bracket 9 Air filter (accessory) In case bottom-suction FDX(K)S50 J 12.7 (Flare connection) 3D045486D FDK/XS60C unit (mm) 300 or more Signal transmitter (Service space) (Suspension bolt pitch) 20 or more 20 or more 400 or more (In case bottom-suction) 240 or more Ceiling Infrared remote control FDXS60CVMB: (ARC433A7) FDKS60CVMB: (ARC433A8) (Service space) 26-J4.7 Hole Operation lamp Room temp. sensor (Suspension bolt pitch) Allow view A Inspection door (ceiling opening) Timer lamp Indoor unit ON/OFF switch Home leave lamp Signal receiver 24-M5 holes Infrared receiver unit Cord (length: 1900mm) 18-M4 Holes 24-M5 holes Notes: 1. In case of back-suction, mount chamber cover to bottom side of the unit. In case of bottom-suction, mount chamber cover to back side of the unit. 2. Location of unit s name plate: control box cover. (unit: mm). 3. Mount the air filter at the suction side. (select its colorimethod (gravity method) 50% or more). It can not be equipped with air filter (accessory) when connecting duct to suction side. In case of back suction 1 Liquid pipe connection J6.4 (Flare connection) 2 Gas pipe connection J12.7 (Flare connection) 3 Socket for drain VP20 (O.D. J26 / I.D. J20) 4 Drain hose (accessory) I.D. J 25 (Outlet) 5 Control box 6 Infrared receiver unit connection 7 Power supply connection 8 Suspension bracket 9 Air filter (accessory) In case bottom-suction 3D045487C Split Sky Air Indoor Units 5

Indoor Units R410A FDKS-CVMB 3 Dimensional drawing & centre of gravity 3-2 Centre of gravity FDK/XS50C 3 4D046081D 6 Split Sky Air Indoor Units

Indoor Units R410A FDKS-CVMB 3 Dimensional drawing & centre of gravity 3-2 Centre of gravity FDK/XS60C 3 3 4D046082C Split Sky Air Indoor Units 7

4 Piping diagram Indoor Units R410A FDKS-CVMB FDK/XS50-60C Indoor unit 4 Heat exchanger Thermistor on heat exchanger Model FDXS50CVMB FDKS50CVMB FDXS60CVMB FDKS60CVMB A J 12.7 Field piping Sirocco fan Fan motor Field piping Refrigerant flow Cooling Heating 4D045449F 8 Split Sky Air Indoor Units

Indoor Units R410A FDKS-CVMB 5 Wiring diagram 5-1 Wiring diagram FDK/XS50-60C 3 5 Outdoor Signal receiver Infrared remote control (Terminal for centralised control) Indoor NOTES 1 Size: length 60 x width 125. 2 Nameplate material: wood free tack paper 3 Coat the reverse side with pressure sensitive adhesive 4 Refer to purchasing specification AS303002, unless otherwise specified. 5 This drawing was drawn on CAD system. 6 Make a slit on separate liner in vertical direction Transmission circuit C1 F1U H1P H3P M1F PCB1 PCB2 Q1M R1T R2T S1 S32,RTH1 S1W V1TR X1M Z1C R g Field wiring CAUTION Notice that operation will restart automatically when the main power supply is turned off and then turned on again. : Capacitor (M1F) : Fuse : Pilot lamp : Fan motor : Printed circuit board : Thermal protector (M1F embedded) : Thermistor : Connector : Operation switch : Phase control circuit : Terminal block : Noise filter (ferrite core) : Protective earth 3D045012G Split Sky Air Indoor Units 9

6 Sound data Indoor Units R410A FDKS-CVMB 6-1 Sound pressure spectrum FDKS50C FDKS60C 6 Octave band sound pressure level db:(0db = 0.0002 µ bar) Octave band sound pressure level db:(0db = 0.0002 µ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D046335B NOTES Octave band center frequency (Hz) 1 Operation noise differs with operation and ambient conditions. 2 The operating sound is based on the rear side suction inlet, and the external static pressure 40Pa. Location of microphone 4D046336B NOTES Octave band center frequency (Hz) 1 Operation noise differs with operation and ambient conditions. 2 The operating sound is based on the rear side suction inlet, and the external static pressure 40Pa. Location of microphone Discharge Duct Duct Suction Discharge Duct Duct Suction Microphone Legend (H) 230V/50Hz, 220V/60Hz (L) 230V/50Hz, 220V/60Hz Microphone Legend (H) 230V/50Hz, 220V/60Hz (L) 230V/50Hz, 220V/60Hz 10 Split Sky Air Indoor Units

7 Fan characteristics Indoor Units R410A FDKS-CVMB FDK/XS50C FDK/XS60C 3 7 External static pressure Upper limit of external static pressure L H External static pressure SL L Upper limit of external static pressure H Lower limit of external static pressure SL Lower limit of external static pressure Air flow (m 3 /min) 3D045763C Air flow (m 3 /min) 3D045762C Split Sky Air Indoor Units 11

7 Fan characteristics Indoor Units R410A FDKS-CVMB 7 12 Split Sky Air Indoor Units

Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Zandvoordestraat 300 B-8400 Ostend - Belgium www.daikineurope.com EEDE06-1/3 05/2006 Prepared in Belgium by Lannoo ÉEEDE06-1/3ÇËÍ