TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Similar documents
TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500)

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

SPLIT SYSTEM HEAT PUMPS 14 SEER

SPLIT SYSTEM HEAT PUMPS "ERC" Series

SPLIT-SYSTEM CONDENSING UNITS. HRC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE STELLAR 2000 TM MODELS: H*DB012 THRU H*DB076 (1 Ø & 3 Ø) SPLIT-SYSTEM AIR CONDITIONERS A TG2Y (02/00) DESCRIPTION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial High-Efficiency Condensing Units

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

PAJ3. Product Specifications

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

2 shp 13 lc 1 36 t - 1 a

T P A 120 S 4 S N 1 Y

Commercial High-Efficiency Condensing Units

14 AC x

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R4H4. Product Specifications

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

R4H4. Product Specifications

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL SPECIFICATIONS

PACKAGE AIR CONDITIONER

50TM TFF COMBINATION HEATING/COOLING UNITS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

50TM COMBINATION HEATING/COOLING UNITS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

N4A6. Product Specifications

13 SEER CONDENSING UNITS

WJH4 Product Specifications

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

PRODUCT SPECIFICATIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

16 SEER TWO-STAGE AIR CONDITIONERS

PAR5. Product Specifications

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

MERIT SERIES Up Flow / Horizontal

Corp L2 Revised

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

TECHNICAL SPECIFICATIONS

Split System Cooling Product & Performance Data

TECHNICAL SPECIFICATIONS

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

N4H4. Product Specifications

MAC-120HE-03 Air-Cooled Chiller

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

WCH5**4. Product Specifications

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

T S A 048 S 4 N 4 1 T

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

TECHNICAL SPECIFICATIONS

MERIT Series R-410A - Upflow / Horizontal

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

High Heat COP. High/Low Stage

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

MERIT Series R-410A - Upflow / Horizontal

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

48TF GAS HEATING/ ELECTRIC COOLING UNITS

HIGH EFFICIENCY AIR HANDLER

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

13 GEP A L P - 1 A

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Transcription:

TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com Additional rating information can be found at www.ari.org/aridirectory. 261645-BTG-C-0108 DESCRIPTION The 10 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of UPG s complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal applications to provide a complete system. Electric Heaters are available if required. Add-On coils are available for use with upflow, downflow or horizontal furnaces and air handlers. WARRANTY Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES QUALITY CONDENSER COILS - The coil is constructed of enhanced copper tube and aluminum fins. COIL PROTECTION - Coils are protected from damage by a polymer mesh applied between the coil face, and a PVC coated steel coil guard. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted desert sand finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

261645-BTG-C-0108 PHYSICAL AND ELECTRICAL DATA - 3 Phase MODEL T036S T042S T048S T060S T076S W036S W042S W048S Unit Supply Voltage 208-230V, 3φ, 60Hz 460, 3φ, 60Hz Normal Voltage Range 1 187 to 252 432 to 504 W060S Minimum Circuit Ampacity 15.0 17.4 17.3 21.3 25.8 8.0 8.4 8.3 10.8 13.0 Max. Overcurrent Device Amps 2 25 30 30 35 40 15 15 15 15 20 Min. Overcurrent Device Amps 3 15 20 20 25 30 15 15 15 15 15 W076S Compressor Type Recip Recip Recip Scroll Scroll Recip Recip Recip Scroll Scroll Compressor Rated Load 10.9 12.8 11.7 16.0 18.9 5.8 6.1 6.1 8.0 9.5 Amps Locked Rotor 78 78 78 125 146 40 39 39 67 73 Crankcase Heater No No No No No No No No No No Fan Motor Amps Rated Load 1.4 1.4 1.3 1.3 2.2.8.8.7.8 1.2 Fan Diameter Inches 18 18 22 22 24 18 18 22 22 24 Rated HP 1/4 1/4 1/4 1/4 1/3 1/4 1/4 1/5 1/4 1/3 Fan Motor Nominal RPM 1,100 1,100 850 850 1100 1,100 1,100 850 850 1100 Nominal CFM 2,750 2,750 3,250 3,450 4000 2,750 2,750 3,250 3,450 4000 Face Area Sq. Ft. 9.15 12.58 15.72 23.58 18.0 9.15 12.58 15.72 23.58 18.0 Coil Rows Deep 1 1 1 1 2 1 1 1 1 2 Fin / Inches 18 18 18 18 16 18 18 18 18 16 Liquid Line OD (Field Installed) 3/8 3/8 3/8 3/8 1/2 3/8 3/8 3/8 3/8 1/2 Vapor Line OD (Field Installed) 3/4 3/4 7/8 7/8 1-1/8 3/4 3/4 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) 4 3-15 5-4 7-5 9-15 12-15 3-15 5-4 7-5 9-15 12-15 Charge Per Foot, Oz. 4.68.68.70.70 1.26.68.68.70.70 1.26 Operating Weight Lbs. 170 176 206 228 219 170 176 206 228 219 1. Rated in accordance with ARI Standard 110, utilization range A. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. DIMENSIONS A C Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A 1 B C Liquid Vapor 036 19 35 23 3/4 042 25 35 23 3/8 048 27 37 27 7/8 060 39 37 27 076 26 43 32 1/2 1-1/8 B 1. Including Fan guard. 2 Unitary Products Group

261645-BTG-C-0108 Additional R-22 Charge / Orifice Size for Various Matched Systems - 3 Phase Outdoor Unit (T,W)036S (T,W)042S (T,W)048S (T,W)060S (T,W)076S Unit Orifice (s) 1 67, 71, 73 75, 78, 81 81 90 Factory R-22 Charge, lbs-oz 3-15 5-4 7-5 9-15 12-15 Unit Orifice (s) 2,3 Additional Charge, Oz FC/MC/PC/UC36 61 + 3 FC/MC/PC/UC42 75 + 1 FC/MC/PC/UC48 78 + 9 81 + 15 FC/MC/PC/UC60 78 + 16 90 + 5 AHP18 AHP24 AHP36 75 + 11 AHP42 75 + 11 78 + 6 AHP48 78 + 16 81 + 20 AHP60 78 + 16 90 + 5 F*FP036 61 + 5 F*FP042 75 + 1 F*FP045 78 + 14 F5FP048 75 + 9 81 + 15 F5FP060 78 + 16 90 + 5 KDBC090 0 FOOTNOTES: 1. These orifices are packed in the Customer packet of each outdoor unit. 2. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224. 3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing. 2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set. Unitary Products Group 3

261645-BTG-C-0108 COOLING CAPACITY - With Air Handler Coils AIR HANDLER UNIT MODEL MODEL W (T,W)036S (T,W)042S (T,W)048S COIL MODEL 1 3 PH 10 SEER AC WITH MA RATED CFM TOTAL NET MBH COOLING SENS. 1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number. = Not applicable. SEER MA12B 17 FC / MC30B 1200 33.6 24.9 10.00 9.10 MA12B 17 FC / MC36B 1200 33.8 25.0 10.00 9.20 MA12B 17 FC / MC42B 1200 34.4 25.5 10.15 9.30 MA16C 21 FC / MC42C 1380 40.0 30.2 10.00 9.05 MA16C 21 FC / MC48C 1450 41.0 30.3 10.10 9.15 MA14D 24 FC / MC48D 1450 41.0 30.3 10.10 9.15 MA16C 21 FC60C 1450 42.0 31.0 10.10 9.50 MA14D 24 FC / MC60D 1450 42.0 31.0 10.10 9.50 MA16C 21 FC / MC48C 1600 46.0 34.0 10.10 9.50 MA20D 24 FC / MC48D 1600 46.0 34.0 10.10 9.50 MA16C 21 FC60C 1600 47.0 34.0 10.40 9.70 MA20D 24 FC / MC60D 1600 47.0 34.0 10.40 9.70 (T,W)060S MA20D 24 FC / MC60D 1750 58.5 39.8 10.00 10.25 (T,W)036S (T,W)042S (T,W)048S (T,W)060S 3 PH 10 SEER AC WITH AHP/SHP AHP36 17 1235 35.0 24.2 10.30 11.00 F*FP036 24 1200 34.4 35.2 10.20 9.30 F*FP042 21 1200 34.4 25.2 10.15 9.20 AHP42 21 1400 40.0 30.0 10.00 9.20 F*FP042 21 1400 39.5 28.9 10.00 9.00 F5FP048 24 1400 40.5 30.0 10.00 9.20 AHP/SHP48 24 1600 47.0 34.4 10.40 9.70 AHP/SHP60 24 1600 47.0 34.4 10.40 9.70 F5FP048 24 1600 45.5 33.7 10.00 9.15 F5FP060 24 1600 46.5 34.4 10.00 9.70 AHP/SHP60 24 1750 58.5 39.8 10.00 9.80 F5FP060 24 1750 58.5 39.8 10.00 9.80 (T,W)076S K4EU090 22 2600 73.5 10.00 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. EER 4 Unitary Products Group

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL UNIT MODEL CFM RANGE MODEL RATED NET MBH W (MIN.-MAX.) CFM TOTAL SENS. (T,W)036S (T,W)042S (T,W)048S (T,W)060S 1050 1350 1225 1575 1400 1800 1525 1975 261645-BTG-C-0108 SEER 1 17 FC/MC/PC/UC30B 1200 33.6 24.9 10.00 9.10 17 FC/MC/PC/UC36B 1200 33.8 25.0 10.00 9.20 17 FC/MC/PC/UC42B 1200 34.4 25.5 10.15 9.30 14 HC30 1200 33.8 25.0 10.00 9.20 17 HC36 1200 34.4 25.5 10.15 9.30 HD36 1200 34.8 25.8 10.00 8.95 21 FC/MC/PC/UC42C 1380 40.0 30.2 10.00 9.05 21 FC/MC/PC/UC48C 1450 41.0 30.3 10.10 9.15 24 FC/MC/PC/UC48D 1450 41.0 30.3 10.10 9.15 21 FC/MC/PC/UC60C 1450 42.0 31.0 10.10 9.50 24 FC/MC/PC/UC60D 1450 42.0 31.0 10.10 9.50 17 HC36 1380 40.0 30.2 10.00 9.05 21 HC42 1400 41.0 30.3 10.00 9.25 24 HC60 1450 42.0 31.0 10.10 9.50 HD36 1390 40.5 30.0 10.00 9.05 21 FC/MC/PC/UC42C 1500 44.5 32.9 10.00 9.15 21 FC/MC/PC/UC48C 1600 46.0 34.0 10.10 9.50 24 FC/MC/PC/UC48D 1600 46.0 34.0 10.10 9.50 21 FC/MC/PC/UC60C 1600 47.0 34.0 10.40 9.70 24 FC/MC/PC/UC60D 1600 47.0 34.0 10.40 9.70 21 HC48 1600 45.5 33.7 10.00 9.45 24 HC60 1600 47.0 34.0 10.40 9.70 HD36 1600 45.5 33.7 10.00 9.50 HD48 1600 46.5 34.4 10.20 9.65 24 FC/MC/PC/UC60D 1750 58.5 39.8 10.00 10.25 24 HC60 1750 58.5 39.8 10.00 10.25 HD48 1750 58.5 39.8 10.00 10.25 (T,W)076S 2500-3000 35 G2FD090(S,H)35** 3200 73.5 52.9 10.00 1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. EER Unitary Products Group 5

261645-BTG-C-0108 ACCESSORIES *Refer to Price Manual for specific model numbers. HARD START KIT - Provides increased starting torque for areas with low voltage. COMPRESSOR BLANKET - Designed to further reduce the normal compressor operating sound. Refer to price pages for specific match-ups. OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle to prevent rapid recycling of the compressor. ROOM THERMOSTATS - A wide selection of compatible thermostats are available to provide optimum performance and features for any installation. 1H/1C, manual change-over electronic non-programmable thermostat. 1H/1C, auto/manual changeover, electronic programmable, deluxe 7-day, thermostat. 1H/1C, auto/manual changeover, electronic programmable. * For the most current accessory information, refer to the price book or consult factory. SOUND POWER RATINGS* UNIT MODEL (dba) 036 82 042 82 048 82 060 80 076 85 * Rated in accordance with ARI 270-95 Standards. TYPICAL INSTALLATION 60 OVERHEAD CLEARANCE 10 CLEARANCE COIL AREA MINIMUM 24 SERVICE ACCESS CLEARANCE ON ONE SIDE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF. SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL TYPICAL FIELD WIRING - 3 Phase Application ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES POWER WIRING 208/230-3-60 460-3-60 24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2) POWER WIRING CONTROL WIRING FACTORY WIRING FURNACE OR AIR HANDLER TERMINAL BLOCK GND. LUG CONTACTOR TERMINALS COIL * TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT. C Y R G W * Y R G W CONDENSING UNIT ROOM THERMOSTAT ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY. 6 Unitary Products Group

COOLING PERFORMANCE DATA Multipliers for determining the performance with other indoor sections. 261645-BTG-C-0108 AIR CONDITIONER MODEL NO. (T,W)036S INDOOR COIL MODEL NO. FC/MC/PC/UC30 CONDENSER ID CFM 1150 1250 1350 ENTERING AIR ID DB ( F) 85 80 70 85 80 70 85 80 70 TEMPERATURE ID WB ( F) 72 67 57 72 67 57 72 67 57 T.C. 38.3 36.1 34.4 37.9 36.3 34.6 38.0 36.4 34.9 75 S.C. 24.0 23.7 24.0 24.1 24.5 24.7 24.7 25.3 25.2 K.W 3.19 3.14 3.09 3.23 3.20 3.14 3.26 3.23 3.18 T.C. 36.9 34.6 32.2 36.9 34.9 32.6 37.0 35.2 33.0 85 S.C. 24.2 23.7 22.9 24.7 24.6 23.9 25.3 25.5 24.8 K.W 3.45 3.39 3.30 3.50 3.44 3.36 3.53 3.49 3.40 T.C. 35.5 33.2 30.0 35.8 33.6 30.4 36.0 34.0 31.0 95 S.C. 24.3 23.6 21.9 25.4 24.9 23.6 26.0 25.6 24.4 K.W 3.71 3.63 3.52 3.76 3.69 3.58 3.80 3.75 3.62 T.C. 33.2 30.4 26.7 33.4 30.8 27.2 33.6 31.3 27.7 105 S.C. 23.7 22.5 20.7 24.5 23.6 21.9 25.4 24.6 23.0 K.W 3.97 3.84 3.71 4.02 3.91 3.77 4.06 3.96 3.81 T.C. 31.0 27.6 23.5 31.1 28.2 24.2 31.3 28.5 24.4 115 S.C. 23.1 21.3 19.6 23.9 22.6 20.7 24.8 23.7 21.6 K.W 4.22 4.06 3.90 4.29 4.13 3.94 4.33 4.18 4.00 T.C. 28.7 24.8 20.2 28.9 25.6 21.1 29.0 25.7 21.0 125 S.C. 22.5 20.2 18.4 23.2 21.6 19.6 24.2 22.7 20.2 K.W 4.47 4.28 4.09 4.56 4.35 4.11 4.60 4.40 4.19 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA12B FC/MC30B 1.00 1.00 1.00 MA12B FC/MC36B 1.01 1.00 0.99 MA12B FC/MC42B 1.02 1.02 0.98 AHP36 1.04 0.97 0.83 F*FP036 1.02 1.41 0.98 F*FP042 1.02 1.01 0.99 FC/MC/PC/UC36 1.01 1.00 0.99 FC/MC/PC/UC42 1.02 1.02 0.98 HC30 1.01 1.00 0.99 HC36 1.02 1.02 0.98 HD24 1.02 1.02 1.02 HD36 1.04 1.04 1.02 Unitary Products Group 7

261645-BTG-C-0108 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. (T,W)042S INDOOR COIL MODEL NO. FC/MC/PC/UC42 CONDENSER ID CFM 1200 1400 1600 ENTERING AIR ID DB ( F) 85 80 70 85 80 70 85 80 70 TEMPERATURE ID WB ( F) 72 67 57 72 67 57 72 67 57 T.C. 47.2 44.1 41.2 47.5 44.6 41.9 47.9 45.1 42.6 75 S.C. 30.2 29.6 29.4 31.9 31.1 31.0 33.6 32.6 32.6 K.W 3.90 3.85 3.78 4.05 3.99 3.94 4.19 4.14 4.09 T.C. 45.5 42.1 38.5 45.9 42.8 39.3 46.3 43.4 40.2 85 S.C. 29.8 28.9 28.1 31.4 30.7 30.0 33.0 32.5 31.9 K.W 4.13 4.06 3.96 4.28 4.21 4.13 4.43 4.36 4.29 T.C. 43.9 40.2 35.7 44.3 41.0 36.8 44.8 41.8 37.8 95 S.C. 29.5 28.2 26.9 30.9 30.3 29.1 32.4 32.4 31.2 K.W 4.36 4.27 4.14 4.52 4.43 4.31 4.67 4.59 4.49 T.C. 40.5 36.3 32.0 41.2 37.1 32.8 42.0 38.0 33.7 105 S.C. 28.1 26.7 25.1 29.9 28.8 27.2 31.7 30.9 29.3 K.W 4.58 4.44 4.30 4.74 4.60 4.47 4.89 4.77 4.64 T.C. 37.1 32.3 28.3 38.2 33.3 28.9 39.2 34.2 29.6 115 S.C. 26.8 25.1 23.3 29.0 27.2 25.4 31.1 29.4 27.4 K.W 4.81 4.62 4.45 4.96 4.78 4.62 5.10 4.95 4.79 T.C. 33.7 28.4 24.5 35.1 29.4 25.0 36.4 30.4 25.4 125 S.C. 25.5 23.5 21.5 28.0 25.7 23.5 30.5 27.9 25.5 K.W 5.04 4.79 4.61 5.18 4.96 4.78 5.32 5.13 4.94 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA16C FC/MC42C 0.98 1.00 1.02 MA16C FC/MC48C 1.00 1.00 1.01 MA14D FC/MC48D 1.00 1.00 1.01 MA14D FC/MC60D 1.02 1.02 0.97 MA16C FC60C 1.02 1.02 0.97 AHP42 0.98 0.99 1.01 F*FP042 0.96 0.95 1.03 F5FP048 0.99 0.99 1.01 FC/MC/PC/UC48 1.00 1.00 1.01 FC/MC/PC/UC48 1.00 1.00 1.01 FC/MC/PC/UC60 1.02 1.02 0.97 FC/MC/PC/UC60 1.02 1.02 0.97 HC36 0.98 1.00 1.02 HC42 1.00 1.00 1.00 HC60 1.02 1.02 0.97 HD36 0.99 0.99 1.02 8 Unitary Products Group

COOLING PERFORMANCE DATA Multipliers for determining the performance with other indoor sections. 261645-BTG-C-0108 AIR CONDITIONER MODEL NO. (T,W)048S INDOOR COIL MODEL NO. FC/MC/PC/UC42 CONDENSER ID CFM 1200 1400 1600 ENTERING AIR ID DB ( F) 85 80 75 70 85 80 75 70 85 80 75 70 TEMPERATURE ID WB ( F) 72 67 62 57 72 67 62 57 72 67 62 57 T.C. 53.4 48.9 45.1 40.2 54.3 49.8 45.9 41.3 54.9 50.3 46.4 41.8 75 S.C. 32.2 32.3 31.0 32.5 34.0 34.0 32.7 34.7 35.2 35.3 33.9 35.9 K.W 4.32 4.15 4.00 3.83 4.44 4.26 4.11 3.95 4.53 4.36 4.21 4.04 T.C. 52.0 47.5 43.7 39.2 52.7 48.3 44.5 40.0 53.2 48.7 45.2 40.5 85 S.C. 32.2 32.3 31.1 32.7 34.1 34.1 32.8 34.7 35.4 35.5 34.5 36.0 K.W 4.62 4.43 4.26 4.07 4.74 4.55 4.38 4.18 4.84 4.65 4.48 4.28 T.C. 49.0 44.9 41.3 36.9 49.6 45.5 42.0 37.6 50.0 45.8 42.4 38.3 95 S.C. 31.6 31.6 30.4 31.8 33.5 33.7 32.4 33.8 34.9 35.0 33.7 35.6 K.W 4.91 4.70 4.51 4.31 5.02 4.81 4.64 4.43 5.13 4.92 4.74 4.53 T.C. 45.6 41.6 38.4 34.3 46.0 42.2 39.0 35.0 46.2 42.5 39.3 36.2 105 S.C. 30.5 30.6 29.5 30.9 32.6 32.8 31.5 32.8 34.1 34.2 32.7 34.5 K.W 5.18 4.96 4.76 4.54 5.30 5.07 4.88 4.67 5.39 5.18 4.99 4.83 T.C. 41.8 38.3 35.3 31.7 42.3 38.8 35.8 33.0 42.5 39.0 36.2 33.5 115 S.C. 29.3 29.5 28.2 29.6 31.6 31.4 30.1 31.5 33.0 32.9 31.5 32.0 K.W 5.42 5.18 4.98 4.76 5.52 5.31 5.10 4.94 5.63 5.41 5.21 5.06 T.C. 38.0 35.0 32.3 29.1 38.6 35.4 32.7 31.0 38.8 35.5 33.2 30.8 125 S.C. 28.1 28.4 26.9 28.3 30.6 30.0 28.7 30.2 31.9 31.6 30.4 29.5 K.W 5.66 5.40 5.20 4.98 5.74 5.55 5.32 5.21 5.87 5.64 5.43 5.29 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA16C FC / MC42C 0.97 0.97 1.04 MA16C FC / MC48C 1.00 1.00 1.00 MA20D FC / MC48D 1.00 1.00 1.00 MA20D FC / MC60D 1.02 1.00 0.98 MA16C FC60C 1.02 1.00 0.98 AHP / SHP48 1.02 1.01 0.98 AHP / SHP60 1.02 1.01 0.98 F5FP048 0.99 0.99 1.04 F5FP060 1.01 1.01 0.98 FC/MC/PC/UC48 1.00 1.00 1.00 FC/MC/PC/UC48 1.00 1.00 1.00 FC/MC/PC/UC60 1.02 1.00 0.98 FC/MC/PC/UC60 1.02 1.00 0.98 HC48 0.99 0.99 1.01 HC60 1.02 1.00 0.98 HD36 0.99 0.99 1.00 HD48 1.01 1.01 0.98 Unitary Products Group 9

261645-BTG-C-0108 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. (T,W)060S INDOOR COIL MODEL NO. FC/MC/PC/UC60 CONDENSER ID CFM 1450 1700 1950 ENTERING AIR ID DB ( F) 85 80 70 85 80 70 85 80 70 TEMPERATURE ID WB ( F) 72 67 57 72 67 57 72 67 57 T.C. 61.2 58.5 56.3 61.8 59.1 56.9 62.3 59.6 57.5 75 S.C. 37.6 37.4 37.1 40.1 39.9 39.5 42.5 42.3 41.8 K.W 4.66 4.57 4.51 4.67 4.58 4.53 4.68 4.58 4.55 T.C. 60.6 58.0 55.0 61.2 58.6 55.8 61.9 59.3 56.7 85 S.C. 37.6 37.3 36.5 40.2 39.9 39.1 42.8 42.5 41.7 K.W 5.26 5.13 5.08 5.27 5.14 5.10 5.28 5.15 5.11 T.C. 60.0 57.4 53.7 60.7 58.5 54.8 61.4 59.0 55.8 95 S.C. 37.5 37.1 35.9 40.3 39.8 38.8 43.1 42.6 41.6 K.W 5.86 5.70 5.65 5.87 5.71 5.67 5.88 5.72 5.68 T.C. 58.1 54.6 50.0 58.9 55.7 51.3 59.7 56.8 52.7 105 S.C. 36.9 36.0 34.4 39.8 39.0 37.3 42.7 41.9 40.2 K.W 6.54 6.39 6.29 6.56 6.42 6.30 6.57 6.45 6.32 T.C. 56.2 51.8 46.3 57.1 53.2 47.9 57.9 54.5 49.5 115 S.C. 36.2 34.9 32.9 39.3 38.1 35.9 42.3 41.2 38.8 K.W 7.23 7.07 6.92 7.25 7.12 6.94 7.26 7.17 6.97 T.C. 54.3 49.0 42.6 55.2 50.6 44.5 56.2 52.3 46.4 125 S.C. 35.6 33.8 31.4 38.7 37.2 34.4 41.9 40.5 37.4 K.W 7.92 7.76 7.55 7.94 7.83 7.58 7.96 7.90 7.62 Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Air Handler Coil T.C. S.C. KW MA20D FC / MC60D 1.00 1.00 1.00 AHP / SHP60 1.01 1.02 1.02 F5FP060 1.00 1.02 1.02 HC60 1.00 1.00 1.00 HD48 0.99 1.00 1.02 10 Unitary Products Group

COOLING PERFORMANCE DATA Multipliers for determining the performance with other indoor sections. 261645-BTG-C-0108 AIR CONDITIONER MODEL NO. (T,W)076S INDOOR COIL MODEL NO. KDBC-S090 CONDENSER ID CFM 2100 2600 3100 ENTERING AIR ID DB ( F) 85 80 70 85 80 70 85 80 70 TEMPERATURE ID WB ( F) 72 67 57 72 67 57 72 67 57 T.C. 79.1 76.3 73.9 82.0 79.2 76.9 84.9 82.0 79.9 75 S.C. 48.8 48.6 48.1 55.4 55.3 54.7 62.0 61.9 61.3 K.W 5.98 5.90 5.84 6.28 6.18 6.15 6.58 6.48 6.46 T.C. 76.4 73.7 70.6 79.1 76.3 73.4 81.7 79.0 76.2 85 S.C. 47.9 47.6 46.8 54.7 54.4 53.5 61.5 61.2 60.3 K.W 6.53 6.42 6.37 6.86 6.74 6.70 7.18 7.07 7.04 T.C. 73.8 71.1 67.2 76.1 73.5 69.9 78.4 75.9 72.6 95 S.C. 47.1 46.7 45.4 54.0 53.6 52.4 60.9 60.4 59.4 K.W 7.08 6.94 6.90 7.43 7.30 7.26 7.79 7.65 7.61 T.C. 71.1 67.4 62.6 73.1 69.7 65.2 75.1 72.0 67.7 105 S.C. 46.4 45.4 43.7 53.1 52.2 50.5 59.8 58.9 57.2 K.W 7.84 7.70 7.61 8.21 8.08 7.99 8.57 8.46 8.36 T.C. 68.4 63.7 58.0 70.0 67.0 60.4 71.7 68.2 62.9 115 S.C. 45.4 44.1 42.0 52.0 51.9 48.5 58.6 57.5 55.0 K.W 8.59 8.46 8.32 8.97 8.80 8.71 9.36 9.28 9.10 T.C. 65.6 60.1 53.4 67.0 64.3 55.7 68.4 64.3 58.1 125 S.C. 44.5 42.7 40.2 51.0 51.6 46.5 57.5 56.0 52.8 K.W 9.35 9.21 9.02 9.74 9.51 9.43 10.14 10.09 9.84 NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature. Coil T.C. S.C. KW G2FD090(S,H)35 1.00 0.99 1.01 Unitary Products Group 11

Subject to change without notice. Printed in U.S.A. 261645-BTG-C-0108 Copyright by Unitary Products Group 2008. All rights reserved. Supersedes: 261645-BTG-B-0706 Unitary 5005 Norman Products York OK Group Drive 73069