3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Similar documents
6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

SB/ESB SERIES THERMAL PROTECTORS

RP SERIES THERMAL PROTECTORS

4TM SERIES COMPRESSOR CONTROL Motor Protector Refrigeration Compressors

5BT SERIES -65 F to 400 F, SPDT, Welded, Hermetically Sealed ½

4344 SERIES HERMETIC SEALED THERMOSTATS

1NT SERIES Fixed Temperature Thermostats

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

Thermostat Catalog 2004

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

MICRO SWITCH V15W Series Watertight Miniature Switches

Switches & Sensors FOR VALVES & ACTUATORS

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Thermostat Catalog 2004

Guide to Hazardous Location Approvals:

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Original instructions Sense7-series Non-contact coded safety switch

TROPO 15W Dimmable LED Driver

MICRO SWITCH BX/BX2 Series

Interrupted Ignition Series Oil Primary Control

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Wireless Panel-Mount Monitor

Open-area Smoke Imaging Detector. Engineering Specification

SN5446A, 47A, 48, SN54LS47, LS48, LS49 SN7446A, 47A, 48, SN74LS47, LS48, LS49 BCD-TO-SEVEN-SEGMENT DECODERS/DRIVERS

V-Basic Standard V15 Series

Understanding Hazardous Locations Concepts

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

IS Series Pressure Sensing Switches

Series: MBC1-TC Mini Benchtop Temperature Controller

temperature Controllers

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

MODEL 4000A & 4001A ACCELEROMETER

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

NTC Thermistor Temperature Sensors. Product Information and Application Notes

Model 4001 Series Single Channel Controller

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

* Consult factory on conditions for approval acceptability

KILOVAC K1K High-Voltage Contactor

PARAGON Commercial Refrigeration Controls

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Owner's Manual. Voltage Converter. Reverse. 110V to 220V STEP UP. For International Power Connectivity Converts U.S. 110V to Foreign 220V

M5200 Industrial Pressure Transducer

onlinecomponents.com

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

MaxLite LED MICRO-T PANEL

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Digital Refrigerator/Freezer Thermometer model 00986

Model Number Structure

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Circuit Protector. GCP Series. Features. Electromagnetic Overcurrent Protection. Approvals. AC/DC Dual Voltage. Easily Identified ON/OFF Indicator

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

OVERVIEW SWITCHES & PROXIMITY SENSORS MICROSWITCHES LIMIT SWITCHES MANUALLY OPERATED SWITCHES PROXIMITY SENSORS. switches.crouzet.

C6097A,B Pressure Switches

OWNER S MANUAL (English)

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Apex MediTech ALC109 ALARM SYSTEM

OPERATION & INSTALLATION MANUAL

IMPORTANT SAFEGUARDS

CPS V Cabinet Power System

MODEL 834M1 ACCELEROMETER

Introducing SlimSeal SSL Connector

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

T4398A,B Precision Electric Heating Thermostat

SC Installation, Operation & Application Guide

Remote Relay Module (RRM)

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

Dimensions of the Optional Mounting Box (BB-400R/W)

MICRO SWITCH GLL Series

Macurco HD-11 Hydrogen Gas Detector

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Thermometer model 02059

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Viessmann B1HA Boiler Series

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

IMPORTANT SAFETY INFORMATION:

CR Series Command Relays

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

M7100 Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

Analog Room Pressure Monitor RPC Series

Transcription:

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction Automatic reset thermostat designed to meet your specific application requirements. Its patented and tamper proof snap action bi-metal disc provides reliable and repeatable switch actuation. The 3NT is suitable for electrical loads ranging from dry circuits to 10A @ 240 VAC. The core of the 3NT is the proven 1NT thermostat. Recognized by UL/CSA and KEMA/ENEC agencies, hundreds of millions of the 1NT device are in the field today used in a variety of HVAC, appliance, automotive and specialty applications. Manufactured at ISO 9001 certified manufacturing sites, its dry seal allows direct integration of the thermostat into a wire harness eliminating the need for extra connections. SPECIFICATIONS Features Automatic reset Small and easy to mount Fast thermal response Innovative dry seal design - protects from moisture and dust Reliable K cycle life High temperature - to 275ºF (135ºC) Applications HVAC Commercial Dehumidifiers Freezers Heat pumps Ice makers Refrigerators Condensing or moist environments Electrical Ratings Ambient Temperature Temperature rating Minimum Nominal Temperature Differential Dielectric Strength Standard Wire Leads -20 to 135ºC (-4 to 275ºF) -40ºC to maximum wire lead insulation PVC - 105ºC XLP - 125ºC (Allow 15ºC de-rating below wire insulation rating at maximum 10A current) 8ºC (15ºF) Agency UL (USA, Canada) 750 Vrms 1500 Vrms terminals to case Cycles x0 30 30 Volts FLA LRA 120 Vac 240 Vac 120 Vac 240 Vac 30 Vdc 5.8 2.9 10.0 10.0 18 AWG (1/32 or 1/16 wall thickness in either 105 C PVC or 125 C XLPE) 16 AWG (1/32 wall thickness in 105 C PVC) 34.8 17.4 40.0 40.0 Amps (resistive) ENEC (Europe) 30 240 Vac 16 10 10 1 VA 125 125 Page 1

3NT DRY SEAL DESIGN HOUSING LOCKING CONNECTORS O-RING WIRE LEAD ASSEMBLY 1NT THERMOSTAT 3NT CUP Important Notice: The 3NT is not hermetically sealed, and should not be submerged in liquid. For such applications, please contact Sensata. STANDARD TEMPERATURES AND TOLERANCES Nominal Top Temperature Nominal Differential Open Temperature Close Temperature F C F C F C F C 32 to 80 0 to 27 20-29 30-38 39-60 81 to 167 28 to 75 20-23 24-29 30-59 168 to 199 (1) 76 to 93 (1) 20-23 24-29 30-59 200 to 249 (1) 94 to 121 (1) 20-29 30-38 39-59 60-99 250 to 275 122 to 135 24-38 39-59 60-99 (1) Minimum bottom temperature of 50ºC (122ºF) 11-16 17-21 11-13 14-16 17-33 11-13 14-16 17-33 11-16 17-21 34-55 14-21 34-55.5.5.5 ±9 ±12 ±20 ±14.5 ±20.5.5.5 ±5.5 ±11 ±8 ±11 Page 2

TYPICAL PHYSICAL CHARACTERISTICS Dimensions in mm (inches) Basic 3NT Dimensions Surface Mount Clip Locking Tube Mount Clip (3/8 Inch Shown) Open Tube Mount Clip (3/8 Inch Shown at 90º CCW Rotation) 90 and 180 CW Rotations Available Snap Tube Mount Clip For 5/8 Inch and 1/2 Inch Tubes Additional Clips Available for [1/4], [5/16], [1/2], [5/8] t ubes Additional Clips Available for [1/4], [5/16], [1/2], [5/8] tubes Additional Clips Available for [3/4], [7/8] tubes Page 3

ORDERING OPTIONS Part Number Temperature Code Family 3NT Contact Material 01: Silver 11: Gold <12V or < ma Switch Opening Logic L: On Temp. Rise F: On Temp. fall Dry Seal Construction H: High Temp. (Silicon rubber) N: No leads ID Number -Temperature Code -Wire Leads 3NT 01 L H XXXX -Specifications -Terminals and Mounting Clip L: Limit F: Fan Nominal Opening Temperature Temp. Code C: Celsius F: Fahrenheit Differential Difference between Nominal Open and Nominal Close Temperature L 50 F 30 AGENCY APPROVALS & CERTIFICATIONS File/Report Number Category UL (USA) (2) SA995 Category SDFY2 UL (CANADA) (2) SA995 Category SDFY8 DEKRA (ENEC) 2014531.16 EN60730-1, EN60730-2-9 DEKRA (IECEx) 21862646400 IEC60079-0, IEC60079-15 IEC60529 (2) Recognized to US and Canadian requirements by Underwriters Laboratories (UL873 and C22.2 No. 24) IMPORTANT NOTICE These devices may not be used as service components, strictly for use by Original Equipment Manufacturer, not repair. USERS ARE SOLELY RESPONSIBLE for design application and function of the end use product. Users must evaluate the suitability of these devices to their application with respect to temperature settings, mechanical cycle life, electrical loading and environmental conditions. This product is not hermetically sealed, it should not be submerged in any liquid. This product is not rated as explosion proof and should not be applied in any application where flammable vapors, gases or dust may be present. End of life failure of this device may result in either open or closed circuit condition. Suitable End of life protection should be applied in series with this device per safety agency specifications. Page 4

WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE The product s side panels may be hot, allow the product to cool before touching Follow proper mounting instructions including torque values Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH Disconnect all power before installing or working with this equipment Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury Page 5 Sensata Technologies, Inc. ( Sensata ) data sheets are solely intended to assist designers ( Buyers ) who are developing systems that incorporate Sensata products (also referred to herein as components ). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED AS IS. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata s terms and conditions of sale supplied at SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev:02/02/18 CONTACT US Americas +1 (888) 438 2214 sensors@sensata.com Europe, Middle East & Africa +359 (2) 804 7165 temperature-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82-10-9218-1179 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808