The Alfa Laval. Cleaning procedures. for. HeatExchangers.

Similar documents
Instruction Manual Plate Condenser. AlfaCond 400/600/800. Part number

Description. Main components. Lifting eyes To used for lifting and transport securing. Carrying bar Carries the cassettes and the pressure plate.

Channel plates Heat is transferred from one medium to the other through the thin channel plates.

COPYRIGHT Alfa Laval Lund AB, 2012 How to contact Alfa Laval Contact details for all countries are continually updated on our website.

Instruction Manual - Plate Heat Exchangers

M3 M6 M10 TS6 T2 T5 TL3 TL6

eng ger fre Instruction Manual Plate Heat Exchangers spa M3 M6 M10 TS6 TL6 por ita swe dan fin dut rus pol Part number nor

PLATE HEAT EXCHANGERS. Operation and Maintenance Manual

Rycroft Supapac Plate Heat Exchangers

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Carry Out Maintenance Procedures

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

INTAC PARTS & SERVICES ( H)

Instruction manual ISO-MIX Skid Mounted Pump Unit

MRO CHEMICALS CLEANERS & DEGREASERS

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Instruction and Maintenance Manual. Spiral Heat Exchanger

To who it may concerns. I-Ravenna, March 11 th, 2016 HEAT EXCHANGER MAINTENANCE

Descaler & Prevention

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Laboratory Glassware Cleaning and Storage

B.) Accident -- Any suddenly occurring unintentional event which causes injury or property damage.

Innovative Cleaning Technology

Humidifier De-scaling Solution. and Neutralizer. Usage Instructions. IMPORTANT: Read and save these instructions. Before

We recommend regular maintenance to keep your sink looking its best!

HRS Heat Exchangers Instruction Manual

Operation of heat exchangers

about our systems our programs closed loop technology

Technews. March-April 2004 EFFECTIVE CLEANING AND SANITIZATION OF DAIRY PLANTS: 2. COMMON PRACTICES

Nuova Saimar srl. Ravenna - Italy. Over twenty years experience in the Oil & Gas Field

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

CARRON PHOENIX Homecare Pack

TSL-Aerofoil. wall mounted basin. installation + maintenance

Waste-heat recovery: Weighing in the environmental Factor

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

RFP# FS REGION 8 TIPS FOOD PURCHASING CO-OP SANITATION AND CLEANING SUPPLIES FOR FOOD SERVICE AREA ONLY. Drop Ship 1 location 50 CT

The plating industry

Industrial Descale Solutions & Descale Services

Procedural guide to the self-monitoring of trade waste pre treatment devices

CHAPTER 8 OCCUPATIONAL HEALTH AND SAFETY

Product Application Guide SCI-TECH ENGINEERED CHEMICALS

ST-1 Surface Treatment

Z86 Safety-Plus Industrial Cleaner Concentrate

HAVABLACK S2G BLACK OXIDE SALTS FOR IRON & STEEL

Pretreatment Processes for the Aluminum Extrusion Industry. Harry Adams - BCI Surface Technologies Bruce Chambeau Republic Chemical Co., Inc.

MAINTAINING OPTIMUM PERFORMANCE

PLATE HEAT EXCHANGERS BETTER BY DESIGN

Nattura brand cleaning products meet the

POISON S6 NOT TO BE TAKEN KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING

TECHNICAL INFORMATION Physical Developer Catalog Nos. LPD100, LPD101

James Law Chemicals Limited. Product List

Secure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil

COMPONENTS SOLUTIONS MAINTENANCE PRODUCTS. for refrigeration and air conditioning systems

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Food and Beverage brochure. Hygienic design wall mounted enclosures and accessories

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

Pesticide Applicator Equipment Cleaning to Prevent Carryover. Chuck Schuster University of Maryland Extension

Washroom care programs

Student Lab Procedures. Lab Safety Orientation

PERFORM Operating Document

Maintenance Guide. Contents

Metal, ceramic, plastic package products

Chemtex Speciality Limited is a fast growing company manufacturing cleaning chemicals for food and beverage & dairy industry, disinfectants and

INSTALLATION AND USER MANUAL

For routine maintenance of polished granite installations with a cleaner and protector:

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.

LINOLEUM FLOOR CARE MANUAL

Developed by. Cleaning and Sanitation

SureBlend. SureBlend. dilution control program

Haz Waste Management

Electric Pressure Washer

POOL WINTERIZING INSTRUCTIONS

RK/ RK Carbon Monoxide Detector Operator s Manual

CASE STUDY PLASTIC INJECTION MOLD CLEANING

Thermal Steel Care & Maintenance Guide

PLATE HEAT EXCHANGER

REGULAR MAINTENANCE AND CARE

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Before digging into the 10 things you should know let s start with a brief explanation of the process.

^ Blade Hand Dryer Model: GS-2006H SLV

Sanosil disinfectants Use in CIP procedures

Washroom care programs

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

Care and Maintenance For EcoGranit sinks

1. Conduct yourself in a responsible manner at all times in the laboratory.

Self-priming centrifugal pumps

I.F.U Re/Processing Reusable Medical Devices

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Purify your chromic acid solution at the same time that you chrome plate parts.

Muskogee Public Schools Custodial Procedures for Floor Care

Sanitation Controls for Food Processing

HAVE A SAMPLING AND ANALYSIS PLAN (SAP)

NBSeries Installation Operation & Maintenance

SAFETY ZONE SHEET & TILE MAINTENANCE

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

SERVICE REQUIREMENTS

Application: Response procedures for major and minor spills, including: organic solvents acids bases dry chemicals mercury hydrofluoric acid

Transcription:

The Alfa Laval Cleaning procedures for HeatExchangers. Ulf.Grevillius@AlfaLaval.com Portfolio management /EPSi 09/05/2008

Table of Contents Page General Environmental regulations and CIP 3 Safety instructions 4 Why use Alfa Laval Chemicals 5 Warning: Chemicals Not to be used! 5 CIP-program # 1: Removal of Calcium carbonate scaling 6 CIP-program # 2: Removal of Calcium carbonate scaling (Re-usage) 7 CIP-program # 3: Removal of Calciumcarbonate scaling 8 CIP-program # 4: Removal of Biological/Organic fouling (without scaling) CIP-program # 5: Removal of Biological/Organic fouling with scaling 9 10 CIP-program # 6: Removal of Calcium carbonate scaling 11 CIP-program # 7: Removal of Organic fouling 12 Cleaning of Opened PHE 13 Cleaning of Twin-plates of Opened PHE 14 Cleaning loose Twin-plates of Opened PHE 15 page 2/15

General Environmental regulations and CIP As a rule, cleaning solutions are strong alkaline or acidic liquids. Alkalinity or acidity of the cleaning solution is reduced during the cleaning process, but the solutions are still strong acids or alkalis. In several cases, industrial plants (particularly chemical plants) have waste treatment utilities that are capable of handling CIP effluent. This simplifies the CIP process since neutralization is not necessary. However, the situation gets more complicated when waste treatment utilities are not available for treatment of CIP waste. In these cases, the used cleaning solution must be neutralized to a ph of 6-8 in the CIP equipment prior to the discharge. This neutralization may be performed either directly in the circulation tank following each cleaning procedure with immediate discharge or in a separate storage tank. After neutralization, most cleaning solutions may be released into public waters under the condition that the fouling deposits do not contain heavy metals or other toxic compounds. We recommend the neutralized chemicals be analysed for any type of hazardous compounds that were removed from the system. Check with your local authority for regulation of waste water disposal. page 3/15

Safety instructions Warning! Corrosive cleaning liquids. Can cause serious injuries to skin and eye! Cleaning agents used for CIP are acid or strong alkaline liquids. They can cause serious injuries to skin and eyes. Read instructions on the containers of the liquids on what actions to take if liquid has come into contact with skin or eye. When using the CIP unit wear protective clothing: Safety boots must be worn Safety gloves must be worn Eye protection must be worn page 4/15

Why use Alfa Laval Cleaning agents The liquids have carefully selected formulations They have been tested and approved by our laboratory The liquids are corrosion safe for all common metals if the procedures are followed They are compatible with gaskets and adhesives The solutions supplied are concentrated Alfa Laval guarantees that plates, gaskets or glue are not damaged if the procedures given and cleaning agents prescribed are followed Warning: Chemicals NOT to be used! HCl - aggressive to the plate as well as personal safety H2SO4 - aggressive to plate & gasket as well as personal safety HNO3 - aggressive to the gasket as well as personal safety page 5/15

CIP program # 1 Removal of Calcium carbonate scaling Products: AlfaPhos AlfaNeutra ph strips 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 Heat up the PHE to 50-60 C 5 Mix 1 part AlfaPhos with 10 parts of water. 6 The solution is entered into PHE until it is filled up. Now heat up the solution to 50-60 C. 7 The CIP unit is run for 2-4 hours, until the PHE is clean. The ph-value shall never exceed the value 2.5 during the cleaning. This is controlled by measuring the ph-value in equable periods during the cleaning. To lower the ph-value, add AlfaPhos to the solution. 8 When the cleaning is finished solution is being neutralized by gently adding AlfaNeutra or AlfaCaus until the ph-value reaches 6,5-7,5. The neutralization should be performed carefully and with continuous circulation for 30 min. (If the cleaning liquid should be reused do not neutralize it.) 9 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 10 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 6/15

CIP program # 2 Removal of Calcium carbonate scaling (Re-usage) Products: AlfaPhos AlfaNeutra ph strips 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 Heat up the PHE to 50-60 C 5 Mix 1 part AlfaPhos with 10 parts of water. 6 The solution is entered into PHE until it is filled up. Now heat up the solution to 50-60 C. 7 The CIP unit is run for 2-4 hours, until the PHE is clean. The ph-value shall never exceed the value 2.5 during the cleaning. This is controlled by measuring the ph-value in equable periods during the cleaning. To lower the ph-value, add AlfaPhos to the solution. 8 Drain the PHE on the AlfaPhos. 9 Mix 1 part AlfaNeutra with 40 parts of water. 10 The solution is entered into PHE until it is filled up. This solution should be circulated for 30 min. 11 Now the solution is being neutralized by gently adding AlfaPhos until the ph-value reaches 6,5-7,5. 12 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 13 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 7/15

CIP program # 3 Removal of Calciumcarbonate scaling Products: Alfa P-Scale Alfa P-Neutra ph strips 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 5 Heat up the PHE to 50-60 C 6 Mixing of Alfa P-Scale 1 bag with 10-15 liters of water. 2 bags with 15-20 liters of water 7 The solution is entered into PHE until it is filled up. Now heat up the solution to 50-60 C. 8 The CIP unit is run for 2-4 hours, until the PHE is clean. 9 When the cleaning is finished solution is being neutralized by adding 1 bag Alfa P-Neutra per bag Alfa P-Scale until the ph-value reaches 6,5-7,5. The neutralization should be performed carefully and with continuous circulation for 30 min. 10 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 11 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 8/15

CIP program # 4 Removal of Biological/Organic fouling (without scaling) Products: AlfaCaus AlfaPhos ph strips 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 Heat up the PHE to 60-70 C. Note! For Alfa CIP 20/40 units max liquid temp. is 60 C. 5 Mix 1 part AlfaCaus with 10 parts of water. 6 The solution is entered into PHE until it is filled up. Now heat up the solution to 60-70 C. 7 The CIP unit is run for 2-4 hours, until the PHE is clean. The ph-value shall never go below the value 12 during the cleaning. This is controlled by measuring the ph-value in equable periods during the cleaning. To rise the ph-value, add AlfaCaus to the solution. 8 When the cleaning is finished solution is being neutralized by gently adding AlfaPhos until the ph-value reaches 6,5-7,5. The neutralization should be performed carefully and with continuous circulation for 30 min. 9 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 10 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 9/15

CIP program # 5 Removal of Biological/Organic fouling with scaling Products: AlfaCaus AlfaPhos ph strips 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 Heat up the PHE to 60-70 C. Note! For Alfa CIP 20/40 units max liquid temp. is 60 C. 5 Mix 1 part AlfaCaus with 10 parts of water. 6 The solution is entered into PHE until it is filled up. Now heat up the solution to 60-70 C. 7 The CIP unit is run for 2-4 hours, until the PHE is clean. The ph-value shall never go below the value 12 during the cleaning. This is controlled by measuring the ph-value in equable periods during the cleaning. To rise the ph-value, add AlfaCaus to the solution. 8 When the biological fouling is removed the solution shall be neutralized by gently adding AlfaPhos until the ph-value reaches 6,5-7,5. 9 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 10 Now proceed with CIP program # 1. 11 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 10/15

CIP program # 6 Removal of Calcium carbonate scaling Products: Alpacon Descalent AlfaNeutra ph strips - Alpacon Degreaser 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 Heat up the PHE to 50-70 C. Note! For Alfa CIP 20/40 units max liquid temp. is 60 C. 5 Mix 1 part Alpacon Descalent with 7 parts of water. Alpacon Descalent will create foam when getting in contact with calcium carbonate; to prevent this add 5% of Alpacon Degreaser. Mix thoroughly before use. 6 The solution is entered into PHE until it is filled up. Now heat up the solution to 50-70 C. 7 The CIP unit is run for 3-6 hours, until the PHE is clean. The ph-value shall never exceed the value 2.5 during the cleaning. This is controlled by measuring the ph-value in equable periods during the cleaning. To lower the ph-value, add Alpacon Descalent to the solution. 8 When the cleaning is finished solution is being neutralized by gently adding AlfaNeutra until the ph-value reaches 6,5-7,5. The neutralization should be performed carefully and with continuous circulation for 30 min. 9 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 10 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 11/15

CIP program # 7 Removal of Organic fouling Products: Alpacon Degreaser ph strips- 1 Follow the Generalised description of the CIP-procedure. See section Operation in Manual for CIP unit. 2 IMPORTANT! Secure all Connections with bundle strap/duck tape in order for them not to by accident open. 3 Fill the CIP unit with water (max 90% of the liquid required) and test run the system in order to spot leakages before mixing the cleaning agents into the liquid. 4 Heat up the PHE to 40-60 C. 5 Mix 1 part Alpacon Degreaser with 10 parts of water. 6 The solution is entered into PHE until it is filled up. Now heat up the solution to 40-60 C. 7 The CIP unit is run for 3-6 hours, until the PHE is clean.. 8 Drain the PHE and tank from the liquid considering environmental and safety aspects as described on page 1. 9 Flush the CIP-unit and the heat exchanger with water for 15-20 minutes before being put into operation. Contact Alfa Laval sales company if you have further questions and information on CIP-cleaning. page 12/15

Cleaning of Opened PHE Removal of deposits Products: AlfaPhos Alfa P-Scale Alpacon Descalent AlfaCaus Alpacon Degreaser 1. Follow the General description as above. 2. Start cleaning when heating surface is still wet and plates are hanging in the frame. 3. Use fibre brush and preferably hot water jet to start with. 4. If necessary, put the plates in a suitable tank and use one of the following chemicals to remove deposits: Oxides, Carbonates Organics, Proteins Fats, Oils AlfaPhos, Alfa P-Scale, Alpacon Descalent AlfaCaus, Kerosene, AlfaCaus, Alpacon Degreaser 5. Flush the plates with clear preferably hot water. WARNING! AlfaCaus is based on caustic soda and can cause serious injuries by skin contact and have to be handled with great care. 6. Avoid to clean CB units with iron connections (or other iron part) by simple immersion to the acidic bath. page 13/15

Cleaning of Twin-plates of Opened PHE Cleaning of welded channels before opening of unit Products: Fresh water AlfaPhos Alfa P-Scale Alpacon Descalent AlfaCaus Alpacon Degreaser 1 Follow the General description as above. 2 As the welded channels normally contain an aggressive liquid which has to be removed from the unit, it is wise to arrange connections for fresh water between the unit and the in- and outlet valves making it possible to flush out the aggressive liquid with hot fresh water or other for the purpose suitable cleaning agent. 3 The inlet for the cleaning liquid shall be at the lower connection of the unit. 4 After opening of the unit the cleaning of the gasket channels may proceed according to current instruction with the plates still hanging in the frame 5 Clean with appropriate chemical as the recommended cleaning method describes to remove fouling on the welded side. 6 Flush the plates with clear preferably hot water. WARNING! AlfaCaus is based on caustic soda and can cause serious injuries by skin contact and have to be handled with great care. page 14/15

Cleaning loose Twin-plates of Opened PHE Cleaning of loose twin-plates Products: AlfaPhos Alfa P-Scale Alpacon Descalent AlfaCaus Alpacon Degreaser Fresh water 1. Follow the General description as above. 2. It is difficult to clean the inside of twin-plates. 3. There must be a flow in the welded channel to transport the dirt out of the cassette. 4. Leaving twin-plates in a chemical bath will NOT clean the welded channel. NEITHER will dipping plates with the long side into a bath. This will only result in an air pocket for dirt. 5. This will only result in an air pocket for dirt. Twin-plates should be dipped with the short side into a bath to allow a flow through the channel. 6. Neutralise the surfaces and rinse thoroughly with clear preferably hot water. WARNING! AlfaCaus is based on caustic soda and can cause serious injuries by skin contact and have to be handled with great care. page 15/15