CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Similar documents
02/18/2018. Project: VB Jamestown Elementary, Guilford County NC 108 POTTER DRIVE JAMESTOWN, NC

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Super-Flo Low Profile Unit Cooler

Commercial High-Efficiency Condensing Units

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

LOW PROFILE UNIT COOLER

Air-Cooled Condensing Units with Compact Screw Compressors

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

TLV Low Velocity Evaporators

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

High Profile Evaporator

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Low Profile Unit Coolers

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

C13-Series Engineering Guide

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Low Profile Unit Coolers

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

LOW PROFILE UNIT COOLER

Commercial High-Efficiency Condensing Units

WCH5**4. Product Specifications

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

KTL Two-Way Low Profile Evaporators

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Kramersaver Air Cooled Condensing Units

Specifications and Performance S2H

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

horizontal air discharge outdoor discus condensing unit

ThermoSaver TM Hot Gas Defrost System

Air-Cooled Condensing Units with Bitzer Compressors

ThermoSaver TM Hot Gas Defrost System

SMALL AIR COOLED CONDENSERS

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Advance Release September 2009

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Center Mount Unit Coolers

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Condensing Unit Installation and Operating Instructions

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

VertiCool Aurora Engineering Guide

R4H4. Product Specifications

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

R4H4. Product Specifications

Installation, Start-Up and Service Instructions

Condensing Unit Installation and Operating Instructions

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

commercial refrigeration products

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

BTL Two-Way Low Profile Evaporators

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

VariCool VAV Engineering Guide

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

N4H4. Product Specifications

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

30GT FLOTRONIC AIR-COOLED CHILLERS

KTL Two-Way Low Profile Unit Coolers

PACKAGE AIR CONDITIONER

Condensing Units w/ Screw Compressors

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

50TM TFF COMBINATION HEATING/COOLING UNITS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

50TM COMBINATION HEATING/COOLING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MACH N-407 Heat Pump Air-Cooled Chiller

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Ruud Achiever Series Air Conditioners

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Transcription:

BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : MODEL FEATURES Copper tubing secured with cushion Outdoor weather-resistant housing Weatherproof electrical control box with clamps made from G90 galvanized steel compressor contactor and fused control Crankcase heater Pre-formed piping circuit Fixed Flooded head pressure control Receiver with fusible plug and liquid Adjustable low pressure control with (unless otherwise indicated) shut off valve flex hose / fixed high pressure control High efficiency PSC fan motor with Suction Service valve High efficiency enhanced copper tube internal overload protection Units are shipped with Helium holding and aluminium fin coil design charge PrePainted steel cabinet MODEL OPTIONS ( * = Shipped Loose ) 1 PRE-ENGINEERED OPTION PACKAGE A - STD B C D E F G H J W L DEFROST FUSING - SHOW SET QTY Up to 30 Amps 35 Amps to 60 Amps ELECTRIC DEFROST KIT (TIMECLOCK INCL.) Up to 40A Htrs, 30A Fans 1 Evap Up to 60A Htrs, 30A Fans 1 Evap Up to 40A Htrs, 30A Fans 2 Evap Up to 60A Htrs, 30A Fans 2 Evap Up to 60A Htrs, 40A Fans 3 Evap Up to 80A Htrs, 50A Fans 3 Evap DEFROST KIT (USE WITH KE2) Up to 30A per Evap 35A to 50A per Evap 115V Control Circuit 30A Contactor 40A Contactor 60A Contactor ADJUSTABLE PRESSURE CONTROLS Danfoss Dual with flex hose 1 ADJUSTABLE PRESSURE CONTROLS Continued Johnson Dual with flex hose Separate High/Low with flex hose BALL VALVE *Liquid Line *Suction Line CABINET FINISH Pre-Painted Steel CAPACITY CONTROL - HOT GAS BYPASS To Inlet of Evaporator To Suction Line Compressor Circuit Breaker Compressor Time Delay Relay CONDENSING UNIT PRISON PACKAGE Tamper Proof Screws Crankcase Pressure Regulator Discharge Air Hood DISCONNECT SWITCH Fused Non-Fused EC FAN MOTORS + SPEED CONTROLLER All Motors Variable Speed - 230V Units SmartSpeed Export Crating Extended 4-Year Compressor Warranty Extended Leg Kit COIL COATING Heresite Coating ElectroFin Coating FIN AND MATERIAL Gold Coat Fins Copper Fins Hail Guard for Condenser Heated and Insulated Receiver Hoffmann Fan Speed Control HOUSING MATERIAL Stainless Steel Insulated Suction Line LIQUID LINE FILTER + SIGHT GLASS Sealed Liquid Line Lock-Out Relay LIQUID LINE SOLENOID VALVE *Standard 230V Coil *Standard 115V Coil Oversized Receiver PHASE / VOLTAGE MONITOR 3-Lead 6-Lead (MotorSaver455) Pump Down Toggle Switch Receiver Inlet Ball Valve Single Point Electrical SUCTION ACCUMULATOR With Heat Exchanger Without Heat Exchanger SUCTION FILTER Sealed Type TIME CLOCK Paragon 8145 Style *230V Paragon 8145 Style *115V Paragon 8145 Style Two Valve AdjustableFlooded Head Pressure Control Wind Guard QuickVac Valves Less Flooding Valve(s) VOLTAGE SYSTEM REFRIGERANT RATING SUCTION TEMP AMBIENT TEMP CAPACITY 208-230/1/60 R448A 0.5Hp 25.1 ºF 95 ºF 6090 BTUH FANS COMPRESSOR CIRCUIT TOTAL QTY POWER FLA/FAN TYPE QTY RLA LRA AMPS WATTS MCA MOP 1 0.5 RST45C1E-CAV-202 1 4.8 24.1 5.3 6.5 15 LIQUID 3/8 in SOUND - REC CAPACITY 5 lb APPROVALS SUCTION 5/8 in WEIGHT 149 lb REF CHARGE MCA.. Minimum Circuit Ampacity, MOP.. Maximum Overcurrent Protection MCA & MOP are for the condensing unit ONLY. Single point connections WILL show different on dataplate. 1 Item No. 3 APPROVED BY : DATE : PAGE 1 OF 9

EH-LINE HERMETIC CONDENSING UNITS-AIR ITEM # : BEHA006M8-HS2C SELECTED OPTION DESCRIPTIONS Cabinet Finish - Pre-Painted Steel Painted G90 galvanized steel. Polytex paint series, QC9861 Mesa Tan Liquid Line Filter + Sight Glass - Sealed Sporlan C Series with ODF solder connections and Sporlan SA moisture indicator factory installed in liquid line. Pre-Engineered Option Package - B Liquid line filter drier and sightglass: Sporlan C Series filter-drier with ODF solder connections and Sporlan SA moisture indicator factory installed in liquid line. PAGE 2 OF 9

NATIONAL REFRIGERATION will furnish equipment in accordance with this drawing and specifications, and subject to its published warranty. Approval of this drawing signifies that the equipment is acceptable under the provision of the job specifications. Any change made hereon by any person whomsoever subject to acceptance by NATIONAL REFRIGERATION at its home office. Dimensions shown are for standard unit less options. DIMENSIONS DIMENSION A 19 3/8 in DIMENSION B 24 7/8 in DIMENSION C 30 3/8 in DIMENSION D 4 in DIMENSION E DIMENSION F DIMENSION G 0 in DIMENSION H CONNECTIONS LIQUID 3/8 in SUCTION 5/8 in DRAIN WATER DISCHARGE PAN LOOP HOT GAS SIDE PORT HOT GAS INLET HOT GAS OUTLET OTHER SHIPPING WEIGHT 149 lb REFRIGERANT CHARGE RECEIVER CAPACITY 5 lb APPROVALS Order Item No: BEHA006M8-HS2C EH-LINE HERMETIC CONDENSING UNITS-AIR DATE : 07 Dec 2017 PROJECT : Brooks Landing REV PAGE 3 OF 9

BLP107MA-S1B-T LOW PROFILE EVAPORATOR ITEM # : MODEL FEATURES 3/8" Tubing coil construction (reduces Hinged drain pan with central universal Ultra efficient Electronically refrigerant operating charge) drain connection (3/4" drain) Commutated Motor (ECM) Factory installed solenoid valve wire Front access to spacious electrical and ** ECM with SmartSpeed Technology harness header compartments High efficiency enhanced copper tube Heavy gauge textured aluminum cabinet Schrader connection on suction header and aluminium fin coil design construction resists scratches/corrosion Attractive and durable high density 6 FPI Spacious piping end compartment allows polyethylene fan guards for easy assembly PRE-ASSEMBLED EVAP 1 Sporlan TXV, LLSV,T-stat SmartVap AD with Sporlan TXV + Solvlv Danfoss TXV, LLSV, T-stat EEV Kit - Sporlan EEV + Kelvin II EEV Kit - Emerson EEV + EX48 KE2 Evap Efficiency w/sporlan TXV KE2 Evap Efficiency w/sporlan EEV *KE2 Evap Efficiency w/sporlan TXV *KE2 Evap Efficiency w/sporlan EEV KE2 Evap Efficiency w/ke2 EEV *KE2 Evap Efficiency w/ke2 EEV Carel EEV Kit + KE2Temp+Defrost Aux Sideport Connector CABINET FINISH Painted White Painted Black Stainless Steel SENSORS FOR CPC I O BOARDS Coil Temp Sensor Return Air Temp Sensor Suction Pressure Transducer DEMAND DEFROST ELECTRONIC CONTROLLER KE2 Therm Evaporator Efficiency *KE2 Therm Evaporator Efficiency Dual Circuit ELECTRONIC CONTROLLER KE2 Temp+Defrost SmartVap Air Defrost MODEL OPTIONS ( * = Shipped Loose ) EXPANSION VALVE 1 Sporlan TXV Emerson TXV Sporlan EEV Emerson EEV Carel E2V + EVD ice Controller SENSOR + TRANSDUCER FOR EEV for use with Emerson EEV for use with KE2 Therm EEV Other Brand - Specify in Notes ELECTRONIC SH CONTROLLER FOR EEV *Sporlan Kelvin II EEV Controller *Emerson EEV Controller *Other EEV Controller- Specify MFR Model in Notes Evaporator Disconnect Switch EVAPORATOR PRISON PACKAGE Tamper Proof Screws Export Crating COIL COATING Heresite Coating ElectroFin Coating FIN AND MATERIAL Gold Coat Fins Copper Fins Insulated Drain Pan KE2 THERM *SmartGate Router #20695 *8 Port Switch #20166 *CAT5e Shielded Cable - 50ft w/connectors 40' Leads on Sensors + Transducers KE2 THERM Continued Ethernet Adapter Kit *Liquid / Suction Heat Exchanger LIQUID LINE SOLENOID VALVE 1 Sporlan Emerson By Others Field Supplied Dual Voltage Coil 120-230V Field Wired Nitrogen Charged and Sealed ROOM THERMOSTATS 1 Mechanical *Mechanical *Johnson A19ABC *Johnson A421ABC-02C Ranco ETC-111000 *Ranco ETC-111000 Johnson A421ABC-02 Wire Fan Guards REMOTE DEFROST PANEL *230V Control *115V Control INSTALLATION REQUIREMENTS 1 Minimum slope of 1" per foot on all drain lines 1 P-trap per evap required ouside of box VOLTAGE SYSTEM REFRIGERANT AIR FLOW EVAP. TEMP BOX TEMP CAPACITY 115/1/60 R448A 900 CFM 25.6 ºF 35 ºF 6090 BTUH FANS HEATERS CIRCUIT TOTAL QTY POWER FLA/FAN TYPE QTY AMPS AMPS WATTS MCA MOP 1 0.07HP 1 1 60 1.3 15 DISTRIBUTOR 1/2 in SOUND - REC CAPACITY APPROVALS SUCTION 5/8 in WEIGHT 48 lb REF CHARGE 1 lb MCA.. Minimum Circuit Ampacity, MOP.. Maximum Overcurrent Protection APPROVED BY : DATE : PAGE 4 OF 9

LOW PROFILE EVAPORATOR ITEM # : BLP107MA-S1B-T SELECTED OPTION DESCRIPTIONS Expansion Valve - Sporlan TXV May be Type EBQ, S, SBF, O externally equalized thermostatic expansion valve. Valves are selected using the specified capacity and operating conditions of the refrigeration system as specified on the accompanying Certified Prints. Installation Requirements - Minimum slope of 1" per foot on all drain lines Bally recommends a minimum slope of 1" per foot on all drain lines. Installation Requirements - P-trap per evap required ouside of box All evaporators must be trapped individually outside of the box to prevent vapor migration back to coil surface. Liquid Line Solenoid Valve - Sporlan Sporlan solenoid coil voltage matches evaporator voltage except when evaporator is 460V, then 230V solenoid coil is used. Exceptions must be clearly explained in the Notes of the option. Pre-assembled Evap - Sporlan TXV, LLSV,T-stat Option Package consists of factory installed Sporlan balance port TXV, Sporlan liquid line solenoid valve and Johnson Controls A19 Room thermostat. Room Thermostats - Mechanical Single stage temperature control with Single-Pole, Double-Throw (SPDT) mechanical switch. May be Johnson A19 or equal, Operating range of -30 F to +100 F. Adjustable differential of 3 F to 12 F. Factory installed and wired. PAGE 5 OF 9

NATIONAL REFRIGERATION will furnish equipment in accordance with this drawing and specifications, and subject to its published warranty. Approval of this drawing signifies that the equipment is acceptable under the provision of the job specifications. Any change made hereon by any person whomsoever subject to acceptance by NATIONAL REFRIGERATION at its home office. Dimensions shown are for standard unit less options. DIMENSIONS DIMENSION A 30 1/4 in DIMENSION B 17 1/4 in DIMENSION C DIMENSION D DIMENSION E DIMENSION F DIMENSION G 0 in DIMENSION H CONNECTIONS DISTRIBUTOR 1/2 in SUCTION 5/8 in DRAIN 3/4 in WATER DISCHARGE PAN LOOP HOT GAS SIDE PORT HOT GAS INLET HOT GAS OUTLET OTHER SHIPPING WEIGHT 48 lb REFRIGERANT CHARGE 1 lb RECEIVER CAPACITY APPROVALS Order Item No: BLP107MA-S1B-T LOW PROFILE EVAPORATOR DATE : 07 Dec 2017 PROJECT : Brooks Landing REV PAGE 6 OF 9