CITY OF HEALDSBURG 2015-16 MEASURE V SENIOR CENTER IMPROVEMENT PROJECT VICINITY MAP DRAWING INDEX ARCHITECTURAL A-0 COVER SHEET HEALDSBURG SENIOR CENTER SC-1 SENIOR CENTER FLOOR PLAN SC-1.1 SENIOR CENTER DETAILED FLOOR PLAN / CASEWORK SCHEDULE SC-2 SENIOR CENTER EXTERIOR ELEVATIONS SC-3 SENIOR CENTER INTERIOR ELEV. / DETAILS SC-4 SENIOR CENTER BLD'G. SECTIONS / DETAILS SC-5 SENIOR CENTER ROOF PLAN SC-6 ROOF DETAILS SC-6.1 ROOF DETAILS MECHANICAL (HVAC) OWNER / LOCATIONS OWNER: CITY OF HEALDSBURG 401 GROVE STREET HEALDSBURG, CALIFORNIA 95448 LOCATION: HEALDSBURG SENIOR CENTER 131 MATHESON STREET HEALDSBURG, CALIFORNIA STATISTICS PROJECT MANAGEMENT ALAMEIDA ARCHITECTURE PROJECT CONSTRUCTION MANAGEMENT 555 S. MAIN STREET, SUITE 2 SEBASTOPOL, CA 95472 (707) 824-1219 WWW.ALAMEIDA.COM CITY OF HEALDSBURG 2015-16 MEASURE V MULTI-SITE IMPROVEMENT PROJECT HEALDSBURG SENIOR CENTER M-0.1 MECHANICAL NOTES M0.2 SCHEDULES M-2.1 SENIOR CENTER HVAC FLOOR PLAN M-6.1 DETAILS CALGREEN AND CA TITLE 24 BUILDING TYPE: V-B BASIC ALLOWABLE SQ. FEET = 9,000 S.F. FIRE SPRINKLERS = YES ALLOWABLE WITH SPRINKLER INCREASE = 27,000 ACTUAL SQUARE FEET = 4,828 S.F. NUMBER OF STORIES = 1 OCCUPANCY GROUP = B PARKING REQUIRED = 0 PARKING PROVIDED = 0 HEALDSBURG SENIOR CENTER 131 MATHESON STREET HEALDSBURG, CALIFORNIA CG-1 CG-2 CALGREEN FORMS CALGREEN FORMS T-1 TITLE 24 FORMS T-2 TITLE 24 FORMS RE T L GIS A E TER D D E. R A A RCH L R A C M EI IT E C R DO N D T D C-19767 A Exp. 11/30/15 1. 2. 3. 4. 5. 6. 7. 8. GENERAL NOTES ALL WORK CONFORM TO APPLICABLE CODES, REGULATIONS, LAWS AND ORDINANCES AS REQUIRED AND BY THE CODES AND REGULATIONS LISTED IN THESE CONSTRUCTION DOCUMENTS AND MANUALS.. VERIFY ALL DIMENSIONS IN THE FIELD. NOTIFY THE ARCHITECT OF ANY DISCREPANCY AND OBTAIN CLARIFICATION BEFORE PROCEEDING WITH THE AFFECTED WORK. FOLLOW NUMERICAL DIMENSIONS: DO NOT SCALE, USE DATUM POINTS TO START DIMENSION STRING LAYOUT. FLOOR PLAN DIMENSIONS SHOWN ARE TO FACE OF FINISH OR CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. SEE SYMBOLS. BEFORE BEGINNING WORK AT THE SITE, WHERE POSSIBLE AND THROUGHOUT THE COURSE OF WORK, INSPECT AND VERIFY THE LOCATION AND CONDITION OF ITEMS AFFECTED BY THE WORK UNDER THIS CONTRACT AND REPORT DISCREPANCIES TO ARCHITECT BEFORE DOING THE WORK RELATED TO THAT BEING INSPECTED. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT. INCIDENTAL WORK MAY ALSO BE NECESSARY IN AREAS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS DUE TO CHANGES AFFECTING EXISTING MECHANICAL, ELECTRICAL PLUMBING OR OTHER SYSTEMS. SUCH INCIDENTAL WORK IS ALSO PART OF THIS CONTRACT. DO NOT DRILL OR CUT EXISTING JOISTS, BEAMS, COLUMNS OR OTHER STRUCTURAL ELEMENTS UNLESS SPECIFICALLY INDICATED. PREPARE, SUBMIT AND RECIEVE APPROVAL OF SLEEVE AND OPENING DRAWINGS BEFORE LOCATING SLEEVES AND OPENINGS IN FIRE-RATED CONSTRUCTION AND BEFORE CUTTING FIRE-RATED CONSTRUCTION. WHERE "MATCH EXISTING" IS INDICATED: NEW CONSTRUCTION OF FINISHES AS APPROPRIATE TO THE NOTE, SHALL MATCH ADJACENT CONSTRUCTION AND FINISHES. 9. FIRE BLOCKING SHALL BE PROVIDED IN ALL CONCEALED SPACES, WALL CAVITIES INCLUDED, ACCORDING TO I.B.C. SECTION 708.2.1 1. 2. 3. 4. FIRE NOTES FIRE ALARM: THE EXISTING FIRE ALARM SYSTEM SHALL BE EXTENDED TO COVER ANY NEW AREAS CREATED/MODIFIED AS A RESULT OF THIS PROJECT. INSTALLATION OF SAID SYSTEM SHALL BE IN ACCORDANCE WITH NFPA-72 (2013 EDITION). THE FIRE ALARM SYSTEM CAPABLE OF SUPERVISING THE NEW OR EXTENDED COMMERCIAL FIRE ALARM SYSTEM INSTALLED AS A SPRINKLER SYSTEM MONITORING ALARM SHALL ALSO PROVIDE NOTIFICATION FOR THE PURPOSE OF INITIATING EMERGENCY ACTION, INCLUDING THOSE SYSTEMS ACTIVATED SOLELY BY FIRE SPRINKLER SYSTEMS, SO THAT OCCUPANTS OF THE BUILDING SHALL BE NOTIFIED AUDIBLY AND VISUALLY WITHIN EACH SUITE OR BUILDING DIVISION. A MINIMUM OF ONE NOTIFICATION APPLIANCE SHALL BE LOCATED IN EACH SUITE OR BUILDING DIVISION IN AN OCCUPIED LOCATION. PLANS ARE NOT REQUIRED FOR 3 DEVICES OR LESS BUT AN INSPECTION OF THE MODIFIED ALARM SYSTEM IS REQUIRED. CFC 901.4, CFC 907.2, CFC 907.5 CITY ORDINANCE 1130, SEC. 903.4.2 FIRE RESISTIVE ROOFING: THE ROOF ASSEMBLIES HAVING A MINIMUM CLASS B RATING SHALL BE MAINTAIN ON STRUCTURES. CBC 1505 FIRE EXTINGUISHERS: FIRE EXTINGUISHERS WITH A MINIMUM 4A-10BC RATING SHALL BE INSTALLED AT INTERVALS NOT TO EXCEED 75 FEET. EXTINGUISHERS SHALL BE SERVICED WITHIN THE LAST YEAR BY A LICENSED FIRM AND BE MOUNTED ON THE WALL AT CONSPICUOUS LOCATIONS. CFC 906, T19-CH 3 ARTICLE 5 FIRE INSPECTION: A FIRE/SAFETY INSPECTION SHALL BE DONE ON ALL WORK IDENTIFIED ON THIS MEMO BY THE FIRE DEPARTMENT BEFORE FINAL. CFC CHAPTER 1-106 ECOPY APPLICABLE CODES 2013 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R. 2013 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R. (2012 INTERNATIONAL BUILDING CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. (2011 NATIONAL ELECTRICAL CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24 C.C.R. (2012 UNIFORM MECHANICAL CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. (2012 UNIFORM PLUMBING CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R. 2013 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R. (2012 INTERNATIONAL FIRE CODE AND 2013 CALIFORNIA AMENDMENTS) 2013 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11, TITLE 24 C.C.R. 2013 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS. PARTIAL LIST OF APPLICABLE STANDARDS NFPA 10 PORTABLE FIRE EXTINGUISHERS 2009 EDITION NFP A 13 AUTOMATIC SPRINKLER SYSTEMS 2013 EDITION NFPA 14 STANDPIPE SYSTEMS (CA AMENDED) 2013 EDITION NFP A 17 A WET CHEMICAL SYSTEMS 2013 EDITION NFP A 20 STATIONARY PUMPS 2013 EDITION NFPA 24 PRIVATE FIRE MAINS (CA AMENDED) 2010 EDITION NFPA 72 NATIONAL FIRE ALARM CODE (CA AMENDED) 2013 EDITION NFP A 80 FIRE DOOR AND OTHER OPENING PROTECTIVES 2013EDITION NFPA 110 EMERGENCY AND STANDBY POWER SYSTEMS 2013 EDITION NFP A 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2012 EDITION REFERENCE CODE SECTION FOR NFPA STANDARDS - 2010 CBC (SFM) CHAPTER 35. SEE CHAPTER 35 FOR STATE OF CALIFORNIA AMENDMENTS TO NFP A STANDARDS. COMPLIANCE WITH THE CFC CHAPTER 14, FIRE SAFETY DURING CONSTRUCTION, DEMOLITION AND CBC CHAPTER 33, SAFETY DURING CONSTRUCTION WILL BE ENFORCED AMERICAN WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES APPLICABLE SAFETY STANDARDS: REFERENCES HEREIN TO "CAL/OSHA" SHALL MEAN STATE OF CALIFORNIA, DEPARTMENT OF INDUSTRIAL RELATIONS, CONSTRUCTION SAFETY ORDERS, AS AMENDED TO DATE, AND ALL CHANGE AND AMENDMENTS THERETO ARCHITECT: ALAMEIDA ARCHITECTURE 555 SOUTH MAIN STREET, SUITE 2 SEBASTOPOL, CALIFORNIA 95472 (707) 824-1219 FAX (707) 824-2670 CONSULTING ENGINEER: MECHANICAL ENGINEER: CLIMATE MECHANICAL 2914 NEVILE LANE MEDFORD, OREGON 97501 PROJECT DESCRIPTION SCOPE INCLUDES: DIRECTORY 1. THE REPLACEMENT OF HVAC UNITS ROOFING PRESERVATION AND ISOLATED RE-ROOFING AT SENIOR CENTER. 2. KITCHEN IMPROVEMENTS AT SENIOR CENTER. Project number Date Drawn by Checked by Scale ST COVER SHEET A TE A - 0 O F L CA IFO NO. DESCRIPTION DATE 1. ISSUED FOR COUNTY HEALTH DEPT REVIEW 1/12/16 A I RN 1/12/16 D.R.A. D.R.A. N.T.S
ECOPY
ECOPY
ECOPY
EC OP Y
ECOPY
ECOPY
EC OP Y
EC OP Y
EC OP Y
EC OP Y SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT SEPARATE BUILDING PERMIT MEASURE V PROJECT
ECOPY
EC OP Y
EC OP Y
ECOPY
EC OP Y
ECOPY