Model 6496 Freezing Rain Sensor

Similar documents
Model 5190-E Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Model 6021 Electrically Heated Rain and Snow Gauge

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Instruction Manual Model Backup Switch, 1 for 8

VNC Versatile Network Controller Operation and Installation Manual

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

RS485 MODBUS Module 8AI

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

F500 Elite. FIELDBUS ADAPTER. Watchdog NTC to Modbus RTU communications. (Software Version 3.3.0)

SAFETY INFORMATION AND WARNINGS

430128A. B-Series Flow Meter SIL Safety Manual

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

INSTALLATION INSTRUCTIONS

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

FlameGard 5 UV/IR HART

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Installation, Operation & Service Manual

P2267 NETWORK INTERFACE

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Duct Mount. Installation Instructions

Thermometer model 02059

ADDITIONAL INFORMATION

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

Mark 25 Ultrapure Water Conductivity Analyzer

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

ACQUITY UPLC HT Column Heater Instructions

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

STATUS ALARM HISTORY ALARM RESET

Open Protocol Data Communications

Modbus TCP/IP Option Instruction Manual

Environmental Monitoring SmartSlot Card

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

Simplex Panel Interface Guide

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

User s Manual & Operating Instructions

RK/ RK Carbon Monoxide Detector Operator s Manual

ion Genesis Pump Controller

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

ELSTON 52 CEILING FAN

RK/ RK Oxygen Detector Operator s Manual

MicroTech Unit Ventilator

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ECO N DATE DESCRIPTION OF CHANGE CHG

Reacti-Therm I and III Heating Modules

User s Manual and Operating Instructions

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

13500 BTU RV Air Conditioner Installation and Operating Instructions

IF-L/RF Protection Switch

HIn3550 Magnetic Field Monitor User's Manual

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

GAS MONITOR Model Model

Installation and Owner Man u al

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

6502B RF Distribution

FieldServer Driver - Serial FS Notifier NCA

InstructIon Manual KrEs EQuIPMEnt stands

EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

OWNERS MANUAL MODEL 451 (-101 & -201)

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

TTSIM-1 Sensor Interface Module

Xaact Spot. Xaact Hot Spot

Installation & Operation Manual

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Installation & Operation Manual

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

Operating Instructions & Parts Manual Models 99533, 99532

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

Installation and Operations Manual

PBI Manual. Paradox to KNX-BUS Interface

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Table of Contents SECTION PAGE

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Global Water Instrumentation, Inc.

USER MANUAL FOR OPERATING SYSTEM

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Transcription:

Model 6496 Freezing Rain Sensor User s Manual Rev. A All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

Copyright 2012, All Weather, Inc. All Rights Reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service All Weather, Inc. manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of All Weather, Inc. Throughout this manual, trademarked names might be used. Rather than put a trademark ( ) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion and to the benefit of the trademark owner, and with no intention of infringement. All Weather, Inc. and the All Weather, Inc. logo are trademarks of All Weather, Inc. Disclaimer The information and specifications described in this manual are subject to change without notice. Latest Manual Version For the latest version of this manual, see the Product Manuals page under Reference on our web site at www.allweatherinc.com/. All Weather, Inc. 1165 National Drive Sacramento, CA 95834 Tel.: (916) 928-1000 Fax: (916) 928-1165 Contact Customer Service Phone support is available from 8:00am - 4:30pm PT, Monday through Friday. Call 916-928-1000 and ask for Service. Online support is available by filling out a request at www.allweatherinc.com/customer/support.html E-mail your support request to support@allweatherinc.com

Revision History Revision Date Summary of Changes A 2012 Sept 24 Initial release.

TABLE OF CONTENTS 1. OVERVIEW... 1 1.1 Accessories... 1 2. FUNCTIONAL DESCRIPTION... 2 3. DATA COMMUNICATION... 3 3.1 Data Output... 3 3.1.1 Communication Parameters... 3 3.1.2 Data Format... 3 3.1.3 Poll Command... 5 4. UNPACKING AND INSTALLATION... 6 4.1 Unpacking... 6 4.2 Installation... 6 4.2.1 Mechanical Mounting... 6 4.2.2 Power Connection... 8 4.2.3 Data Connection... 9 4.2.4 Final Steps... 9 5. OPERATION... 10 5.1 Power Interruptions... 10 5.2 Built-In Test (BIT) Capabilities... 10 5.2.1 Hardware Built-In Test... 10 5.2.2 Continuous Built-In Test... 10 5.2.3 BIT Failure That Disables Ice Status Output... 11 5.2.4 Initiated Built-In Test (BIT)... 12 5.3 Operator-Initiated Tests... 12 5.4 Correlation Counting... 12 6. MAINTENANCE... 14 6.1 Periodic Maintenance... 14 6.1.1 Monthly Maintenance... 14 6.1.2 Triannual Maintenance... 14 6.1.3 Annual Maintenance... 14 7. TROUBLESHOOTING... 15 8. REMOVAL AND REPLACEMENT... 16 10. SPECIFICATIONS... 17 11. WARRANTY... 19

1. OVERVIEW The Model 6496 Freezing Rain Sensor uses an ultrasonically vibrating probe to detect the presence of icing conditions. The 40 khz vibrating frequency of the probe decreases as ice, frost, or wet snow accumulate. Once these types of frozen precipitation have accreted on the probe to a thickness of 0.020" (0.5 mm), the frequency decreases by approximately 130 Hz and an internal heater inside the probe assembly turns on to deice the probe. The internal heater draws 35 W during deicing and stays on for 60 seconds. The sensing probe cools within a few seconds. A 24-byte string reporting whether ice is present and status information for the Freezing Rain Sensor is sent to the AWOS Data Collection Platform (DCP) when polled. The DCP combines information from the Freezing Rain Sensor with data from other AWOS sensors to generate reports describing the nature of the freezing rain ice, frost, or wet snow that has accreted on the sensor probe. 1.1 ACCESSORIES The following accessories are available for the Model 6496 Freezing Rain Sensor. Part Number Description M105737-00 Probe Assembly Replacement Gasket M488397-00 Mounting Kit M491742-00 Data Cable (connects Model 6496 Freezing Rain Sensor to DCP) M491745-01 50 ft Power Cable (Model 6496 Freezing Rain Sensor power connector to bare wires) 1

2. FUNCTIONAL DESCRIPTION The Model 6496 Freezing Rain Sensor is mounted on an enclosure containing the power supplies and communication interface (see Figure 1). Extensive internal self-testing identifies problems and provides diagnostic information to indicate whether the sensor is operating properly. Figure 1. Model 6496 Freezing Rain Sensor Enclosure The Probe Assembly (M482221-00) contains the actual Freezing Rain Sensor probe and its associated electronics. The Power Input Board (M404802-01) accepts AC power and provides 24 V DC to the Freezing Rain Sensor probe and its associated electronics. A 12 V DC power supply also draws its power from the Power Input Board to supply power to the the serial converters that output the RS-422 data from to the Freezing Rain Sensor probe to the RS-485 data output connector on the enclosure. 2

3. DATA COMMUNICATION 3.1 DATA OUTPUT The data is output from the Model 6496 Freezing Rain Sensor over an asynchronous RS-485 interface. The data are output in response to a poll command. 3.1.1 Communication Parameters Table 1 lists the settings for the communication parameters. Table 1. 6496 Freezing Rain Sensor Communication Settings Parameter Setting Baud Rate 4800 bps Data Bits 8 Parity None Stop Bits 1 Handshaking None 3.1.2 Data Format The serial string output from the Model 6496 Freezing Rain Sensor has the following format. Table 2. Freezing Rain Sensor Serial Output String Data Format Byte Bit Definition Comments/Interpretation/Range 7 (MSB) String ID 0 6 Reserved for future use 5 3 Unused 0 (first) 1 2 (oscillator frequency) 2 Probe Heater State 1 Ice Output 0 Status Output Oscillator frequency count in hex 1 = Heater ON 0 = Heater OFF 1 = Ice 0 = No ice 1 = Failure 0 = OK (no failure) Frequency = 774060000/Dec (oscillator) 3 (ERRSTAT1) 7 Unused 1 = Active 6 Oscillator failure frequency too high 3

Byte Bit Definition Comments/Interpretation/Range 3 (ERRSTAT2) 5 7 (on-time count) 8 9 (cold start count) 5 Oscillator failure frequency too low 4 EEPROM failure 3 RAM failure 2 ROM failure 1 Watchdog Timer failure 0 Power Interrupt Timer failure 7 6 Probe Heater failure 5 Deicing failure 1 = Active 4 0 Unused Power-On time count (in hex) in 10-minute increments Cold Start Power-On count 4 00 = Probe Heater OK 01 = Probe Heater always On or OPEN 10 = Probe Heater always OFF 11 = Probe Heater ON with 1 enable 000000 01FFFF 0000 FFFF 10 11 (ice count) Ice events 0000 FFFF 12 (failures count) 13 (Failure Detail 1) 14 (Failure Detail 2) 15 (Last Error 1) 16 (Last Error 2) 17 (Second Last Error 1) 18 (Second Last Error 2) 7 4 Total failures encountered. This number is incremented each time the ice detector transitions from OK to fail. Oscillator Frequency failure count 00 FF 0 F 3 0 Heater failure count 0 F Not used See ERRSTAT1 See ERRSTAT2 See ERRSTAT1 See ERRSTAT2

Byte Bit Definition Comments/Interpretation/Range 19 (Permanent Error 1) 20 (Permanent Error 2) 21 (software version) 22 (correlation count) 23 (checksum) 3.1.3 Poll Command See ERRSTAT1 See ERRSTAT2 Software Version per VDD/SC1 0.01" ice accretion increments since power-on Summation (1 byte wide) of bytes 0 22 00 FF 00 FF 00 FF The poll command is summarized below, where 00 is the address. <CR> and <LF> are a carrier return and line feed. FRRA00<CR><LF> DCP Poll Command 5

4. UNPACKING AND INSTALLATION 4.1 UNPACKING The Model 6496 Freezing Rain Sensor is a precision instrument and should be handled with extreme care at all times. When the equipment is received, check that all parts listed on the packing slip are accounted for, and inspect the equipment for visible transport damage. Report any damage or discrepancies to All Weather, Inc. Customer Service. Figure 2 shows the protective covers that are around the probe and the probe assembly at the top of the Model 6496 Freezing Rain Sensor enclosure. Do not remove these protective covers until the enclosure installation has been completed. 4.2 INSTALLATION Figure 2. Probe and Probe Assembly Protective Covers The Model 6496 Freezing Rain Sensor must be firmly mounted to a vertical 2½" pipe for proper operation. The Model 6496 Freezing Rain Sensor should be installed in an open area away from trees, buildings, or other obstructions. Mount the Freezing Rain Sensor so that the probe assembly is oriented into the prevailing wind. 4.2.1 Mechanical Mounting Freezing Rain Sensor The Freezing Rain Sensor mounts on the mast using the M488397-00 Mounting Kit. Refer to Figure 3 and Figure 4 during installation. Mount the Freezing Rain Sensor on the mast with the top of the enclosure 5 6" (167 cm) from ground level, or at least 3 feet (1 meter) above the maximum snow level using Mounting Kit M488261-00. 6

Ground Cable In order for the Freezing Rain Sensor s built-in lightning protection to function properly, the Ceilometer must be grounded. To install grounding, follow the steps below (see Figure 3). 1. Drill and tap a ¼ -20 hole in the mast. Install a grounding clamp in the hole. 2. Connect one end of a length of ground cable (4 AWG multi-strand insulated wire, available from All Weather, Inc. as P/N T605000), to the grounding clamp on the mast. 3. Connect the other end of the ground cable to the ground lug on the underside of the Freezing Rain Sensor. 4. Finally, connect a bare copper ground wire between the ground clamp on the mast and an installed ground rod. Figure 3. Freezing Rain Sensor Mounting 7

Figure 4. Mast Mounting Details 4.2.2 Power Connection 1. Connect the power cord s circular connector to the POWER connector on the bottom of the Freezing Rain Sensor enclosure (see Figure 5). 2. Connect the other (unterminated) end of the cable to a suitable AC source in a junction box BLACK wire is hot, WHITE wire is common, and GREEN wire is ground. It is recommended that power to the junction box be shut off at the breaker panel while the wiring connections are made inside the junction box. Figure 5. Freezing Rain Sensor Connectors 8

4.2.3 Data Connection 1. Connect the data cable s circular connector to the DATA connector on the bottom of the Freezing Rain Sensor enclosure (see Figure 5). 2. Connect the other (unterminated) end of the cable to the RS-485 connections on terminal block TB4 of the Model 1190 DCP. Connect the GREEN ground wire to pin 7 of terminal block TB4. Connect the BLACK wire (RS-485 +) from the signal cable to pin 1 or 3, and connect the WHITE wire (RS-485 ) to pin 2 or 4 of terminal block TB4. These pin connections are also used for RS-485 connections from other sensors. Wait until all wires from any other sensors have been inserted when connecting more than one wire to a terminal block pin before securing the terminal block screw. 4.2.4 Final Steps 1. Check that the ON/OFF power switch inside the enclosure (Figure 1) is ON. 2. Close and fasten the enclosure door. 3. Remove the two probe protective covers shown in Figure 2. 4. Ensure that the circuit breaker on the breaker panel is in the ON position. 9

5. OPERATION The Freezing Rain Sensor operates automatically, and sends data packets to the DCP. There are no controls or indicators on the sensor itself. 5.1 POWER INTERRUPTIONS The Freezing Rain Sensor uses a power-fail monitor to verify the supply voltage. If a power fault lasting more than 200 ms is detected, the Freezing Rain Sensor will report a failure in the STATUS output. 5.2 BUILT-IN TEST (BIT) CAPABILITIES The Freezing Rain Sensor has hardware, continuous, power-up, and operator-initiated tests. Whenever a failure is detected and verified, the Freezing Rain Sensor stops detecting and annunciating icing conditions, and the internal probe heaters are disabled. Failures detected in Initiated and Continuous BIT are counted and enunciated once they have been verified. Failures are verified by delaying (debouncing) the failure for a period of time to minimize or eliminate nuisance errors, Failures detected in Initiated BIT are latched, and power must be cycled off and on to clear a failure. If failures detected in Continuous BIT go away, the probe returns to normal mode, and once again enables all detection functions. 5.2.1 Hardware Built-In Test The hardware BIT consists of a watchdog timer that forces the microcontroller in the Probe Assembly to re-initialize if it does not receive a strobe every 1.6 seconds. An internal voltage monitor forces the microcontroller to the reset state if the internal 5 V DC power supply falls below 4.65 V DC and holds it there until the power supply returns above 4.65 V DC. No output strings are transmitted while the microcontroller is reset. 5.2.2 Continuous Built-In Test The Continuous BIT verifies the following operations. The internal probe heater is in the correct state. The return leg of the heater is monitored. The discrete output for ice is in the correct state. This discrete output is fed back to the microcontroller through a passive voltage divider and voltage comparator. The probe oscillator is operating correctly. Frequencies between 39.00 and 40.15 khz are valid. The internal probe heater is deicing correctly. Once it has turned on, the internal probe heater must cause the probe oscillator frequency to return to at least 39.97 khz within the 25 second timeout, otherwise the internal probe heater is considered to have failed. 10

5.2.3 BIT Failure That Disables Ice Status Output The ice status output is disabled by Continuous and Initiated BIT failures as shown in Table 3. Ice detection is disabled when these failures occur because the integrity of the ice detection capability may be compromised. Table 3. BIT Failure Information Failure Type Ice Detection Disabled Initiated BIT Continuous BIT Oscillator Failure Frequency Too High Oscillator Failure Frequency Too Low EEPROM Failure RAM Failure ROM Failure Watchdog Timer Failure Power Interrupt Timer Failure Power Fault Monitor Failure Internal Probe Heater Always ON Active Test Passive Test Internal Probe Heater Always OFF Active Test Passive Test Internal Probe Heater Always ON with 1 Enable Deicing Failure Clear Only Set Only Unknown Reset Failure Note 1: The software no longer reports the ice status once a failure is annunciated.. Note 2: In Continuous BIT, the Internal Probe Heater Always OFF failure is set when the heater is ON and a deicing failure has been detected. If the frequency indicates that the ice has been removed within the expected time, the software will not annunciate an internal probe heater failure. In this case, the actual failure is most likely caused by a problem in the heater feedback circuitry rather than the heater control circuitry. The failure will be annunciated the next time the Initiated BIT is performed. 11

5.2.4 Initiated Built-In Test (BIT) The Initiated BIT is performed at initial power-up of the Freezing Rain Sensor and following power interruptions that last longer than than 200 ms. The Initiated BIT consists of the following tests: The ice and fault status outputs are set in the serial output string so monitoring electronics or test equipment can verify activation. The Freezing Rain Sensor internal probe heater is turned on for a short period of time to verify correct operation of the heater, heater control circuit, and heater feedback circuit. The correct operation of the watchdog timer is verified by simulating a microcontroller timeout and waiting for a reset input. Proper ROM operation is verified by computing a checksum of the ROM contents and comparing against a a checksum stored in the ROM. RAM operation is verified by writing and reading test bytes. The Power Interrupt Timer is checked by verifying its transitions to a warm state after performing a cold start. The power fail input is pulled down to verify a power failure is detected. Each time the critical data from the EEPROM are read, a checksum is read and compared to the checksum computed from the contents. Each time critical data are written to the serial EEPROM, a checksum is computed and stored with the data. Resets for unknown reasons (such as reset from the watchdog timer) are detected. 5.3 OPERATOR-INITIATED TESTS The operator can test the freezing rain sensor functionality by squeezing the tip of the probe between the index finger and thumb. This simulates icing by decreasing the frequency of the probe. CAUTION B e careful if the probe has just been through a deicing cycle since it may reach temperatures up to 204 C. Clean the probe after touching it as oil residue from skin will affect the performance of the probe. 5.4 CORRELATION COUNTING The Freezing Rain Sensor tracks the ice accumulation on the probe during an icing event. The correlation count helps the Freezing Rain Sensor track the amount of ice that has accumulated on the probe during the icing event. Each correlation count corresponds to a frequency decrease of 65 Hz during the icing event and reflects 0.010" (0.25 mm) of ice buildup. The correlation count, which ranges from 0 to 255, does not take into account the change in collection efficiency caused by ice buildup. The value is no longer incremented once a correlation count of 255 is reached. 12

The Freezing Rain Sensor compensates for the operation of the internal probe heater by adding a value (ranging from 0 to 6) to the correlation count when the ice detection cycle is completed The correlation count is reported in Byte 22 of the serial output string (see Error! Reference source not found.). The correlation count is initialized to zero when the Freezing Rain Sensor powers up. 13

6. MAINTENANCE 6.1 PERIODIC MAINTENANCE Tools and Equipment Required Soft cotton cloth (lint free) Isopropyl alcohol 6.1.1 Monthly Maintenance Inspect all mounting hardware and cable assemblies for wear and damage; repair or replace as needed. 6.1.2 Triannual Maintenance 1. Inspect all mounting hardware and cable assemblies for wear and damage; repair or replace as needed. 2. Visually inspect the probe surface for contaminants such as dirt, oil, fingerprints, etc. 3. If any contaminants are present, clean probe using isopropyl alcohol and soft cotton cloth. WAR NING The freezing rain sensor probe assembly will be hot if the sensor recently completed a deice cycle. E ns ure that the probe as s embly has cooled before cleaning the probe. While in the deice mode, the probe will radiate a significant amount of heat. This can be obs erved by placing a hand close to, but not on, the sensor probe. A lways avoid direc t c ontac t of the probe with skin to avoid a potential burn hazard. CAUTION Do not touch the probe with bare hands, as oil residue from skin will affect the performance of the sensor. 6.1.3 Annual Maintenance No additional maintenance beyond that described above for monthly and triannual maintenance is required. 14

7. TROUBLESHOOTING Symptom Possible Causes Action Freezing rain data missing, or F displayed for sensor status Loose cable or connector No power to Freezing Rain Sensor Freezing Rain Sensor software locked up Freezing Rain Sensor has failed Check all cables and connectors. Repair or replace, if necessary Check main power to the sensor is ON Cycle power to sensor. If no recovery, cycle power to the DCP. If no recovery, replace sensor. Consult the SYSLOG for errors prior to the sensor going missing to confirm faulty operation before failure. Replace sensor, if necessary. Freezing rain data intermittent Loose cables or connectors Check all cables and connectors. Repair or replace, if necessary. Freezing Rain data inaccurate Ice fails to melt from probe Freezing Rain Sensor is faulty Freezing Rain Sensor requires maintenance Freezing Rain Sensor has operational errors Freezing Rain Sensor software has locked up Freezing Rain Sensor internal probe heater or processor has failed or software has locked up Consult the SYSLOG for errors and examine the freezing rain status word for possible causes of the problem. Replace sensor, if necessary. Perform complete maintenance. Cycle power to sensor. If no recovery, cycle power to the DCP. If no recovery, replace sensor. Cycle power to sensor. If data still inaccurate, replace sensor. Cycle power to sensor. If ice still fails to melt, replace sensor. 15

8. REMOVAL AND REPLACEMENT IMPORTANT Observe ESD grounding procedures when handling modules. Do not change modules during weather events; never allow precipitation to enter the interior of the Freezing Rain Sensor. Whenever a module is being changed, the power should be shut off remotely. The only time the power should be on with the Freezing Rain Sensor door open is when checking system operation during troubleshooting. To gain access to the Probe Assembly, open the enclosure door using a screwdriver to release the two latches. Figure 6. Freezing Rain Sensor Probe Assembly 1. The Probe Assembly (part number M482221-00) is mounted at the top of the Freezing Rain Sensor enclosure. 2. Disconnect the wire connector at the bottom of the Probe Assembly. 3. Remove the four screws securing the Probe Assembly to the top of the Freezing Rain Sensor enclosure. 4. Remove the Probe Assembly from the unit. 5. When installing the new Probe Assembly, replace the gasket (part number M105737-00) before installing the new Probe Assembly and securing it in place with the four screws. 6. Reconnect the wire connector to the bottom of the Probe Assembly. The connector is keyed to facilitate lining up the pins to make the connections correctly. 16

10. SPECIFICATIONS Set Point Deicing Parameter Specification Ice signal activates when ice thickness on probe exceeds 0.020 ± 0.005 in (0.5 ± 0.1 mm) Operates when ice thickness on probe exceeds the set point Discrete Output Signals Built-In-Test (BIT) Output Format Serial Output Serial Output Baud Rate Serial Port Parameter Setting Serial Connector Data Output Electrical Supply Voltage Environmental Operating Temperature Storage Temperature Humidity Ice signal Operating status signal Performed at initial power-up. If a failure is detected and verified, the sensor stops detecting and annunciating ice presence, the probe heaters are disabled; and a failure is annunciated. Hardware and software BIT verifies that internal electronics are functioning properly during ongoing operation. RS-485 (half duplex) 4800 bps 8-N-1 (8 data bits, no parity, 1 stop bit) Conxall Mini-Con-X 7280-5SG-300 Field Connector In response to poll command 85 265 V AC 47 64 Hz, 50 W -55 to +70ºC (-67 to +158ºF) -65 to +70ºC (-85 to +158ºF) 0 100% (noncondensing) 17

Parameter Mechanical Mounting Enclosure Dimensions (without mounting tabs) Weight Shipping Weight Specification Unistrut mounted on single- leg pedestal; 2½" pipe NEMA 4X electro-polished 304 stainless steel 20.35" H 12.00" W 9.07" D (51.7 cm 30.5 cm 23.0 cm) 5.5 kg (12 lb) 7.5 kg (17 lb) 18

11. WARRANTY Unless specified otherwise, All Weather Inc. (the Company) warrants its products to be free from defects in material and workmanship under normal use and service for one year from date of installation or a maximum of two years from date of shipment, subject to the following conditions: (a) The obligation of the Company under this warranty is limited to repairing or replacing items or parts which have been returned to the Company and which upon examination are disclosed, to the Company s satisfaction, to have been defective in material or workmanship at time of manufacture. (b) The claimant shall pay the cost of shipping any part or instrument to the Company. If the Company determines the part to be defective in material or workmanship, the Company shall prepay the cost of shipping the repaired instrument to the claimant. Under no circumstances will the Company reimburse claimant for cost incurred in removing and/or reinstalling replacement parts. (c) This warranty shall not apply to any Company products which have been subjected to misuse, negligence or accident. (d) This warranty and the Company s obligation thereunder is in lieu of all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, consequential damages and all other obligations or liabilities. No other person or organization is authorized to give any other warranty or to assume any additional obligation on the Company s behalf, unless made in writing and signed by an authorized officer of the Company. 19

All Weather Inc. 1165 National Drive Sacramento, CA 95818 6496-001 Fax: 916.928.1165 Revision A Phone: 916.928.1000 September, 2012 Toll Free: 800.824.5873