Questionnaire on activities in radiometry and photometry. Reply from: Korea Research Institute of Standards and Science (KRISS)

Similar documents
Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

Quality Manual of Optical Power Measurements

Publication American Institute of Physics. Reprinted with permission.

Development and setting up a calibration facility for UV sensors at high irradiance rates

Spectrum Detector, Inc.

Integrating Sphere Detectors. Wide Range of Stock Items. Individual Custom Configuration and Design. OEM Design and Production. Traceable Calibrations

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

SPECTRAL INSTRUMENTATION

Development of a variable output LED-365 irradiance standard

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

REVIEW OF ULTRAVIOLET AND HIGH POWER LASER MEASUREMENT STANDARDS AT NIST *

Equipment specifications (D6)

Fundamentals of Far-infrared

Lighting Measurement Solutions

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

Propagation loss in optical fibers (01/29/2016)

Understanding total measurement uncertainty in power meters and detectors

818 Series Low-Power Detectors

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

An FT-NIR Primer. NR800-A-006

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Optics & Radiometry Laboratory

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

CALIBRATION HOW IT WORKS

TE LINTELO SYSTEMS BV. light metrology opto-electronic equipment lasers optical components fiber optics. photonics is our passion!

CALIBRATION HOW IT WORKS

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Power Meters Energy Meters

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Comparative study of the conventional and optical communication analog fire detector signal attenuations with various number of fire detectors

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

Digital Sensors Erythema Sensor PMA2101

SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY

CALIBRATION HOW IT WORKS

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Mark Farries. Gooch & Housego

APPLIED. OMA-406R Rackmount Process Analyzer

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

OMA-300 Process Analyzer

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

Current Research Topics in Optical Sensors and Laser Diagnostics

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

Industrial presentation. Philippe Marchais - July 3rd, NDIP Tours

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

UV LED Measurement Status Update

Optical Measurement Techniques for LED Clusters and LED Safety

Fibre Optic Sensors: basic principles and most common applications

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Fli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution

Technological developments in infrared imaging: a fast growing market Dr. François Simoens, CEA-Leti, Marketing & Strategy Manager

Exhibitor Listing S48 S11 S46 S22 S24 S32

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Wildland fire phenomenology experiments:

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

State of the Corona Camera Industry Past, Present and Future RIAAN ROSSOUW

The FEL Facility Optical Diagnostics and FEL Characterization

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Pyroelectric detectors based on high-performance PMN-PT single crystals

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

gray Laser Power Detectors For fast and accurate measurements

UV measurements for medical applications using SiC photodiodes

Optical imaging using coherent anti-stokes Raman scattering and other nonlinear mechanisms

Specifications Wavelength Range: 190 nm to 800 nm continuous

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Broadening IR applications through using spectral filters

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

LUXEON Rebel. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON Rebel Photobiological Safety Report

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

THE PLACE TO BE FOR AUVERGNE RHÔNE-ALPES COMMITTED FRENCH TECH MEMBER

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

PLACEMENT BROCHURE Optoelectronics & Optical Communication(JOP) Official Website:

Radioactive waste repositories monitoring

2018 New Infrared Technologies, S.L.

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Instruments Designed for POF & Fibre Optic Cable Testing

Noyes OFL 250B Specs Provided by

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Technical Information OUSAF44

NanoReady. Micro UV-Vis Spectrophotometer

Recent Advances in Solid State Lasers and Nonlinear Optics for Remote Sensing

1.1. SYSTEM MODELING

Transcription:

CCPR/16-04 Questionnaire on activities in radiometry and photometry Reply from: Korea Research Institute of Standards and Science (KRISS) Delegate: Seung Kwan Kim 1. Summarize the progress in your laboratory in realizing top-level standards of: (a) broad-band radiometric quantities Improvement of radiation thermometer calibration Spectral responsivity measurement with high dynamic range is important to reduce the uncertainty of radiation thermometer calibration. We improved the spectral responsivity measurement of our high temperature radiation thermometer to have a dynamic range of more than 10 8 by utilizing a high power super-continuum laser (SCL) and a double grating monochromator. We also improved the wavelength accuracy of the monochromator to be less than 5 pm by measuring an absorption spectrum of water and oxygen in the air through a trap detector and a wavelength meter. As a result, we could reduce the dynamic range related uncertainty component down to 0.002 K from 0.5 K at 3021 K and the wavelength related uncertainty component down to 0.015 K from 0.3 K at 3021 K. We submitted the results to Metrologia this year. (b) spectral radiometric quantities Calibration of detection efficiency of photon counting detector We developed a practical calibration method of the detection efficiency of photon counting detectors. In order to facilitate it, a switched integrating amplifier-based photocurrent meter that can measure photocurrent down to 100 femto ampere level was developed. The photon counting detector under test with a fiber-coupled input is directly compared with a reference photodiode without using any calibrated attenuator. The calibration was carried out in a wide wavelength range from 480 nm to 840 nm using a fluorescence from a GaN laser diode. The relative standard uncertainty of the detection efficiency was evaluated to be from 0.8 % to 2.2 % varying with wavelength. This work was reported at Single Photon Workshop in 2015

and published in Metrologia 2016. The work on the development of the switched integrating amplifier was also published in Applied Optics 2016. Re-establishment of NIR spectral responsivity scale using a pyroelectric detector We constructed a new pyroelectric detector-based spectral responsivity comparator using a 275 W QTH lamp and an additive double monochromator that can produce more than 5 µw output power per 20 nm bandwidth (FWHM) from 800 nm to 1700 nm. Using this new comparator we achieved the expanded uncertainty of less than 1 % (k=2) when we scaled the spectral responsivity to the KRISS working standard InGaAs detector with the spectral responsivity of the KRISS Si trap detector. From this work, we can disseminate the spectral responsivity scale to industry through InGaAs detector-based certified reference material. Improvement of spectral diffuse reflectance scale transfer We are developing a relative spectral diffuse reflectance (SDR) measurement setup in order to calibrate our spectrophotometer with low uncertainty and to accommodate the artifacts of CCPR-K5. Since it was not easy to directly measure general samples with our primary standard setup using Sharp-Little method, we have used a transfer

standard to calibrate our spectrophotometer but the uncertainty could not have been reduced further because its size and geometry were limited by the primary standard setup. By adopting a relative SDR setup we can overcome the size and geometry limitation to reduce the uncertainty and have capability to accommodate general samples. We finished constructing the relative SRD setup and obtained promising result where the difference between NIST and KRISS traceable measurement was less than 0.2 % in visible range. We submitted the intermediate results to Metrologia this year where we describe the design, theoretical analysis, experimental results and the uncertainty evaluations in detail. (c) photometric quantities Establishment of total spectral radiant flux standard for LED and OLED We established the standard system to provide measurement service for total spectral radiant flux for LED and OLED in the wavelength range from 350 nm to 850 nm. It uses a spectral irradiance standard lamp and a total luminous flux standard lamp to scale the total spectral radiant flux. The overall uncertainty is about 3 % (k=2) in a whole range when we use the DUT size within 25 mm by 25 mm. We transferred the technology of building up the total spectral radiant flux testing system to the LED manufacturing division in Samsung Electronics and helped them to open a standard laboratory traceable to KRISS. 2. What other work has taken place in your laboratory in scientific or technological areas relevant to the CCPR?

Development of single photon source based on Si vacancy center in nano-diamond We built up a single photon generator using a nano-diamond sample having Silicon vacancy centers. Its configuration is a confocal microscope to focus pump photons at 671 nm to a single isolated Silicon vacancy center and collect fluorescence photons from it through a photon-counting detector or a photon level spectrometer. We succeeded in obtaining fluorescence photons from a single isolated Silicon vacancy center and capturing the spatial image with a size of less than 0.6 µm in FWHM. We also succeeded in measuring its spectrum showing the fluorescence photons with a zero phonon line at 738 nm. We are now carrying out g(2)(τ) measuring experiment to demonstrate single photon generation. The intermediate results were reported at QCMC 2016. Development of Mid-IR tunable optical source based on OPO Increasing demand for calibration and test of detectors, cameras, and spectrometers in IR wavelength range beyond NIR makes us start preparing radiometric tools to expand our capability to MIR range. Our initial research work is to develop tunable narrow band optical sources in MIR range based on optical parametric oscillator technology. So far, we succeeded in obtaining the laser output mechanically tunable between 2.6 µm and 3.5 µm from an OPO cavity with a fan-out grating type MgO:PPLN pumped by a single longitudinal mode Nd:YAG laser at 1064 nm. In addition, we developed a tunable single longitudinal mode Tm-doped fiber ring laser in 2 µm range in order to pump a ZGP crystal to obtain OPO output between 4 µm and 8 µm. The tunable fiber laser development was published in IEEE Journal of Photonics in 2016.

CCPR/16-04 3. What work in PR has been/will be terminated in your laboratory, if any, in the past /future few years? Please provide the name of the institution if it has been/will be substituted by a DI or accredited laboratory. None 4. What are present, new or emerging needs of users of your services that are not being supported sufficiently by current CCPR activities or initiatives? In the light of this information please suggest desirable changes in the future working program of the CCPR. There is increasing demand for calibration and test of detectors, cameras, spectrometers, and spectral reflectance/emissivity of materials in mid- and farinfrared range from the sectors of remote sensing and material science. Although the quantities are already listed in the CMC service categories, no explicit activity exists currently within CCPR. Formation of a task group to initiate a working program in the mid- and far-infrared radiometry is suggested. 5. What priorities do you suggest for new research and development programmes at NMIs in the area of Photometry and Radiometry? - Primary standards for few photon-level radiometry - Scale realization and dissemination in the UV (< 300 nm) and mid/far-ir (> 3 µm) - Research on optical properties of materials (analysis and synthesis)

6. Are there any research projects where you might be looking for collaborators from other NMIs or are there studies that might be suitable for collaboration or coordination between NMIs? - Calibration of quantum efficiency of single photon counters as a function of wavelength - Development of single photon sources - Spectral responsivity scale for UV (< 300 nm) and IR (> 1600 nm): realization, dissemination, and validation of scale - Spectral reflectance scale for UV (< 300 nm) and IR (> 1600 nm): realization, dissemination, and validation of scale 7. Have you got any other information to place before the CCPR in advance of its next meeting? None 8. Bibliography of radiometry and photometry papers of your laboratory since the last CCPR (September 2014)? [1] Sun Do Lim, Jae-Keun Yoo and Seung Kwan Kim, Widely Tunable Watt-Level Single-Frequency Tm-Doped Fiber Ring Laser as Pump for Mid-IR Frequency Generation, IEEE Photon. J. 8 (3), 1502006 (2016). [2] Hee Jung Lee, Seongchong Park, Hee Su Park, Kee Suk Hong, Dong-Hoon Lee, Heonoh Kim, Myoungsik Cha and Han Seb Moon, Wavelength-scanning calibration of detection efficiency of single photon detectors by direct comparison with a photodiode, Metrologia 53, 908-917 (2016). [3] Seongchong Park, Kee-Suk Hong and Wan-Seop Kim, Switched integration amplifier-based photocurrent meter for accurate spectral responsivity measurement of photometers, Appl. Opt. 55 (9), 2285-2293 (2016). [4] Helmi Zaini, Jae-Keun Yoo, Seongchong Park and Dong-Hoon Lee, Indoor calibration method for UV index meters with a solar simulator and a reference spectroradiometer, Int. J. Metrol. Qual. Eng. 7, 101 (2016). [5] Kee-Suk Hong, Seongchong Park, Seung-Kwan Kim, Seung-Nam Park and Dong- Hoon Lee, Realization of the Spectral Responsivity Scale based on an Absolute Cryogenic Radiometer, J. Kor. Phys. Soc. 67 (12), 2045-2058 (2015). [6] Jisoo Hwang and Ki-Lyong Jeong, Surface Color Measurement Uncertainties, J. Opt. Soc. Kor. 19 (6), 649-657 (2015). [7] Seung Kwan Kim, Dong-Hoon Lee and Seung-Nam Park, APMP supplementary comparison on fiber optic power responsivity APMP.PR-S2, Metrologia Tech. Suppl. 52, 02002 (2015). [8] Khaled Mahmoud, Seongchong Park, Seung-Nam Park and Dong-Hoon Lee, An imaging spectrophotometer for measuring the two-dimensional distribution of spectral reflectance, Metrologia 51, S293-S301 (2014). [9] S. D. Lim, A. M. Karmalawi, S. G. R. Salim, M. A. Soliman, B. H. Kim, D. H. Lee, Y. S. Yoo, A Method to Improve the Temperature Distribution of Holder Around the Fixed-Point Cell Position, Int. J. Thermophys. 35, 1169-1179 (2014). [10] Gen Jung Kim, Yong Shim Yoo, Bong Hak Kim, Sun Do Lim and Jong Hyun Song, A small-size transfer blackbody cavity for calibration of infrared ear thermometers, Physiol. Meas. 35, 753-762 (2014).