ASHRAE/IESNA Standard

Similar documents
August 15, 2013 Page 1 of 19

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

2009 IECC Commercial Mechanical Requirements

HVAC Mandatory Provisions Part II, Page 1

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

C.E.P., C.E.M, C.I.P.E.

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*

SESSION Michigan Energy Code (MEC) Update (3 Technical) Per SMACNA Standard (TAB, Duct Design) and ASHRAE ( ) ASHRAE Detroit Members:

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

COMcheck Software Version Review Mechanical Compliance Certificate

COMMERCIAL ENERGY EFFICIENCY

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

2018 International Energy Conservation Code (IECC) Updates

COMcheck Software Version Mechanical Compliance Certificate

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

1 - This title will copy onto other forms Date

2006 Washington State Nonresidential Energy Code Compliance Form Washington State Nonresidential Energy Code Compliance Forms Revised July 2007

COMMERCIAL ENERGY EFFICIENCY

COMcheck Software Version Mechanical Compliance Certificate

Application of the 2012 North Carolina Energy Conservation Code

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Energy-Efficiency Measures List

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Interior Lighting Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

Mechanical Compliance Certificate

Dehumidifying with Dedicated Outdoor Air

COMcheck Software Version Mechanical Compliance Certificate

Small Building Program Design Phase Assistance

HVAC Controls Upgrades: Requirement Details ( )

HVAC Controls Upgrades: Requirement Details ( )

Summary Comparison of Simulation Program Features

Strategies for Building Energy Efficiency

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

August 27, Section 3.2 Definitions. On page 11 delete the following definition:

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Agenda and Objectives

High Performance Building Guide 1

EarthWise System Seminar

COMcheck Software Version

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

WSA120: New Energy Codes and Lighting Controls

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

Massachusetts Energy Code Compliance Support Commercial Energy Code Building Mechanical & Service Water Heating Provisions

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

COMMERCIAL ENERGY EFFICIENCY

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Temperature. In the HVAC area, we talk about two kinds of temperatures.

ENGINEERING. Edition No. 13 October 2002

4. OVERVIEW OF MECHANICAL SYSTEM

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

CHAPTER 4. HVAC DELIVERY SYSTEMS

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

HVAC Trajectories toward Zero

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Appendix 13. Categories of Cooling and Heating systems

The Ed Roberts Campus Berkeley, CA

TECHNICAL REPORT 3 Mechanical Systems and Existing Conditions Northfield Mental Healthcare Center Northfield, Ohio

COMcheck Software Version Mechanical Compliance Certificate

1 Exam Prep Energy Efficient Building Construction in Florida Questions

Designing Energy Efficient Outdoor Air Systems

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Table of Contents. List of Figures and Tables. Executive Summary: 3 ASHRAE Standard 62.1 Section 6 Analysis 7

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (SI Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Zoned Rooftop Systems. Light commercial packaged rooftop systems from Trane

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Adding More Fan Power Can Be a Good Thing

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Method to test HVAC equipment at part load conditions

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Residential New Home Construction Checklist

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Missouri HERO Program Residential Eligible Product List

Mechanical Technical Report 3. Mechanical Systems Existing Conditions Evaluation

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Notable Changes in the Mechanical Codes

Trane Engineers Newsletter Live

MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

Transcription:

ASHRAE/IESNA Standard 90.1-1999 An inside look at the requirements of Standard 90.1-1999 Energy Standard for Building Except Low-Rise Residential Building Mick Schwedler, PE Sr. Principal Applications Engineer Member SSPC 90.1, 1995-1999 The Trane Company

Goal Gain a working knowledge of ASHRAE Standard 90.1

Background Historical perspective of ASHRAE/IESNA Standard 90.1 90.1 1975 (origin) 90.1 1989 (past) 90.1 1999 (present)

Goals Of Standard 90.1 1999 Energy efficiency But based on life-cycle cost economics Ease of use Global possibilities

Highlights of Standard 90.1 1999 Reorganized for ease of use Written in code language Uses dual units (SI,IP) Implementation considered

Impact in the United States Energy Policy Act of 1992 (EPAct) NEPA Slide

Impact in the United States EPAct States must meet or exceed the requirements of Standard 90.1 1989 DOE must evaluate any revisions to 90.1 DOE can then obligate states to update their codes

Economic Criteria Common economic criteria applied to all sections

Purpose of Standard 90.1-1999 The purpose of this standard is to provide minimum requirements for the energy-efficient design of buildings except low-rise residential buildings

Scope Of Standard 90.1 1999 New buildings, systems New portions of buildings and their systems New systems and equipment in existing buildings Excludes low-rise residential - Standard 90.2

Definitions Definitions Abbreviations Acronyms

Administration & Enforcement Compliance requirements new buildings existing buildings additions alterations Compliance documentation drawings, manuals labeling

Complying With 90.1 1999 New buildings Requirement of each section OR Energy Cost Budget (ECB) Specific tradeoffs for compliance Existing buildings Requirements of each section - limited Specific tradeoffs for compliance

Standard 90.1 1999 Covers Envelope HVAC Service water heating Power Lighting Electric motors

Building Envelope

Building Envelope Based on climate and space type Glazing limit (windows) OR Building Envelope Tradeoff Option Insulation levels Construction Space Type

Features Envelope criteria based on typical envelope assemblies and class construction New true prescriptive option Precalculated values for compliance Benefit is more uniform and fairer implementation

Building Envelope Glazing U-factor, solar heat gain coefficient Orientation Percentage Air leakage sealing, weatherseals, vestibules Building envelope tradeoff option, ENVSTD 3.0 software

Prescriptive Compliance Fenestration Skylight area as a % of gross roof area Vertical fenestration glazing area as a % of gross wall area U-factor is dependent on type SHGC is dependent on orientation

Prescriptive Compliance-Opaque No calculations required Specify insulation R-value or... Look up common U-factors

Overall U-factors: Roofs Roofs with insulation above deck Metal building roofs Roofs with metal joists Wood-framed roofs with attics Single-rafter roof/ceilings with wood joists

Overall U-Factors: Above-Grade Walls Mass walls Metal building walls Metal-framed walls Wood-framed walls

Typical Table Components Roofs Nonresidential Assembly Maximum Insulation Minimum Insulation Entirely above U-0.093 R-10 Deck cont. ins. Metal Building U-0.070 R-19 Attic and Other U-0.034 R-30

Envelope summary Based on space type Single table per climate Common U-factors available Trade-off procedure

HVAC & Service Water Heating

HVAC Section 3 paths to compliance Simplified Approach Mandatory plus prescriptive Mandatory and ECB There s more

Simplified Approach HVAC Section Purpose Same requirements Fits on two pages Limited to Buildings with 1 or 2 stories Air-cooled HVAC systems dedicated to a single zone Buildings less than 25,000 square feet

Mandates HVAC Section Requirements address Equipment Efficiencies Controls Construction and insulation Drawings, manuals and commissioning Part of prescriptive and ECB compliance paths

Equipment Covered HVAC Section Packaged equipment Heat pumps Chillers Packaged terminal/room air conditioners Furnaces Boilers Cooling towers

Equipment Efficiency Examples HVAC Section Type Minimum Efficiency Efficiency 10/29/2001 15-ton rooftop 8.5 EER 9.7 EER 300-ton watercooled centrifugal chiller 5.20 COP 5.30 IPLV 6.10 COP 6.10 IPLV

Equipment Covered for the First Time HVAC Section Ground-source heat pumps Replacement PTAC s PTHP s Single- and double-effect absorption chillers Heat rejection equipment Hot water boilers

Mandatory Control HVAC Section Zone control capability Off-hour controls Automatic Shutdown Setback 75 Optimum start above 10,000 cfm Shutoff damper Zone isolation

Control Off-Hour Controls HVAC Section Automatic Shutdown Automatic time clock w/10 hour battery back up occupancy sensor manually operated timer w/max. 2 hr duration Security system interlock

Mandatory Construction & Insulation HVAC Section Durable insulation Duct and plenum insulation Duct sealing Leakage tests Piping Insulation

Mandatory Completion Requirements HVAC Section Drawings Manuals Operating Maintenance Balancing Airside > 1hp - except calibrated VAV Hydronic pumps >10 hp

Prescriptive HVAC Section Requirements address Economizers Simultaneous heating and cooling Air system design and control Hydronic system design and control Heat rejection equipment control and limitations Heat recovery Exhaust hoods

Prescriptive Economizers HVAC Section Climate and Size Dependent Numerous exceptions High limit controls are climate dependent Airside - up to 100% OA Waterside Size requirement Reduce pressure drop effect

Economizers Climate and Size HVAC Section o. of Hours Between 8 am and 4 pm with 55 F < T db < 69 F 1% Cooling Design Wet-Bulb Temperature T wb < 69 F 69 F T wb 73 F T wb > 73 F Minimum System Size (Btu/h) Minimum System Size (Btu/h) Minimum System Size (Btu/h) 0-199 N.R. N.R. N.R. 200-399 135,000 N.R. N.R. 400-599 135,000 N.R. N.R. 600-799 65,000 135,000 N.R. 800-999 65,000 135,000 135,000 1000-1199 65,000 65,000 135,000 > 1199 65,000 65,000 65,000 R. means that there is no system size for which an economizer is a requirement in this climate.

Economizers Example requirements HVAC Section Locale 1% Design WB No. Hours 8 am 4 pm 55<Tdb<69 System size at which economizer is required Miami, FL 77 259 No economizer required Evansville, IN 76 611 No economizer required Chicago, IL 73 613 135,000 Btuh (11.25 tons) New York, NY 73 790 135,000 Btuh (11.25 tons) Denver, CO 59 739 65,000 Btuh (5.4 tons) Boston, MA 71 713 135,000 Btuh (11.25 tons) Minneapolis, MN 71 566 No economizer required Tucson, AZ 65 716 65,000 Btuh (5.4 tons) San Francisco, CA 62 1796 65,000 Btuh (5.4 tons)

Prescriptive HVAC Section Simultaneous heating and cooling Limits recooling, reheating or mixing Limited airflow per zone Hydronic systems Three pipe not allowed Two pipe changeover control Heat pump systems Two-position valve

Simultaneous heating and cooling Airflow limits per zone HVAC Section Standard 62 zone requirements, or... 0.4 cfm/ft2, or... 300 cfm, or... Standard 62, 6-1 implementation

Simultaneous heating and cooling Dehumidification HVAC Section Prevent Reheating Mixing of hot and cold air streams Heating and cooling of same air stream

Simultaneous heating and cooling Dehumidification HVAC Section Exceptions Reducing supply air flow to 50%, or min. ventilation Systems under 6.67 tons that can unload at least 50% Systems smaller than 3.3 tons Process applications 75% of reheat or recool energy is recovered or solar

Prescriptive Air system design and control HVAC Section Fan system power limitation Applies to systems > 5 hp Limits based on nameplate hp Credits available VAV fan control Motors >= 25 hp 30% design wattage at 50% air volume DDC: Fan pressure optimization

Air system design and control Fan system power HVAC Section Supply Air Volume Allowable Nameplate Motor Power Constant Volume < 20,000 cfm (9400 L/s) 1.2 hp/1000 cfm (1.9 kw/1000 L/s) 20,000 cfm (9400 L/s) 1.1 hp/1000 cfm (1.7 kw/1000 L/s) Variable Volume 1.7 hp/1000 cfm (2.7 kw/1000 L/s) 1.5 hp/1000 cfm (2.4 kw/1000 L/s)

Prescriptive HVAC Section Hydronic system design and control Variable flow required when > 100 feet and 50 hp motor Pump isolation Series chiller exception Written to give latitude Reset with Exceptions Improper operation Variable flow

Prescriptive Heat rejection equipment HVAC Section Fan speed control 7.5 hp and up capability to operate at 2/3 speed or less Exceptions Condenser fans on multiple circuits Condenser fans on flooded condensers Climates with a lot of cooling. 1/3 of the fans on a multiple fan application

Prescriptive Energy recovery HVAC Section Airside 70% OA and 5000 cfm total 50% effectiveness Service Water Heating 24 hrs per day and Heat rejection > 6 MMBtuh and SWH load 1 MMBtuh

Prescriptive Exhaust hoods HVAC Section Kitchen hoods > 5,000 cfm Fume hoods Total > 15,000 cfm Capability to < 50% or... Direct make-up at least 75% of exhaust rate at specified conditions or... Heat recovery for make-up air

Prescriptive Radiant heating HVAC Section Loading docks Unenclosed spaces

Prescriptive Hot Gas Bypass Limitation HVAC Section >= 7.5 tons Multiple steps or continuous unloading Rated Capacity Maximum Hot Gas Bypass Capacity (% of Total Capacity) 240,000 Btu/h (70 kw) 50% > 240,000 Btu/h (70 kw) 25%

Service Water Heating Efficiency Insulation Service Water Heating System Controls Pool heaters and covers Prescriptive for Space and water heating Service water heating

Lighting

Lighting Scope Lighting Control Interior and exterior Lighting Power Interior and exterior Building type and use

Interior Control Requirements At least one control in each space Automatic shutoff for buildings > 5,000 ft 2 Reduced general lighting for use during clean-up

Interior Lighting Power Building Area Method Building Budget (W) = LPD x area (ft 2 ) Where LPD is Lighting Power Density (W/ft 2 )

Building Area Lighting Power Densities Hospital 1.6 W/ft 2 Library 1.5 W/ft 2 Manufacturing 2.2 W/ft 2 Museum 1.6 W/ft 2 Office 1.3 W/ft 2 Retail 1.9 W/ft 2 School 1.5 W/ft 2

Interior Lighting Power Space-by-Space Method (W/ft 2 ) Office Enclosed 1.5 Office Open 1.3 Conference 1.5 Training 1.6 Lobby 1.8 Dining 1.4 Food Prep 2.2 Corridor 0.7 Restroom 1.0 Active Storage 1.1 Lounge 1.4 Power may be traded between spaces

Additional Interior Lighting Power Decorative luminaires - 1.0 W/ft 2 in space where used Luminaires designed to eliminate computer screen glare - 0.35 W/ft 2 Accent Lighting Additional 1.6 W/ft 2, or Additional 3.9 W/ft 2 for fine merchandise

Exterior Lighting Controls Must have some means of automatic shutoff during daylight hours.

Exterior Building Lighting Power Application Building Entrance w/ canopy Building Entrance w/o canopy Building exit Building facades Power Limits 3 W/ft 2 of canopied area 33 W/lin ft of door width 20 W/lin ft of door width 0.25 W/ft 2 of vertical facade

Site Lighting luminaire efficacy 60 lumens/watt for lamp/ballast combinations > 100

Lighting Alterations in Existing Buildings Replacement of lighting systems meet the lighting power density requirements New control devices have a maximum area they can cover Exception: When <50% of luminaires replaced

Electric Motors Motor efficiency

Energy Cost Budget (ECB) maximum allowable energy cost for the proposed design Computer simulation for tradeoffs between building functions

ECB Compliance = estimated annual energy cost of proposed building less than or equal to energy cost of complying equivalent building

Who s Affected? Owners Occupants Consulting engineers System designers Installers Operators

ASHRAE/IESNA Standard 90.1 Published Members - $75 Non-members - $98 Available www.ashrae.org 800-527-4723 (U.S. & Canada) 404-636-8400 Being studied by the U.S. DOE (EPAct) Likely to be adopted by some Under continuous maintenance

Questions?