BIRMINGHAM TOWNSHIP CHESTER COUNTY, PENNSYLVANIA Subdivision and Land Development Ordinance No Dated 02/18/03

Similar documents
NORTH COVENTRY TOWNSHIP SUBDIVISION & LAND DEVELOPMENT ORDINANCE LIGHTING

in the IESNA Lighting Handbook and applicable Recommended Practices, except as otherwise required by the Board of Supervisors. 2.

from Warwick Township, Chester County, Zoning Ordinance, Amended April 7, 2008

Union Township Berks County Outdoor Lighting 08/18/03 ORDINANCE NO

Uniformity Avg. : Min. Maintained Use/Task

SUBDIVISION & LAND DEVELOPMENT ORDINANCE

UPPER DUBLIN TOWNSHIP MONTGOMERY COUNTY, PA STAND-ALONE LIGHTING ORDINANCE

MODEL OUTDOOR LIGHTING ORDINANCE FOR USE AS A STAND-ALONE CODE

ARTICLE 22, DIVISION 10 LIGHTING

SECTION LIGHTING REGULATIONS

ARTICLE 10 EXTERIOR LIGHTING

ARTICLE 31 EXTERIOR LIGHTING

ARTICLE XVI LIGHTING, NOISE AND ODOR/ODOROUS MATTER Shelby County Zoning Regulations 2013

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

CHAPTER 32 EXTERIOR LIGHTING

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

Article 14. LIGHTING REGULATIONS

8.6 EXTERIOR LIGHTING

Public Hearing, July 12, 2018

Lighting Guidelines. Planning Services Department Corporation of the Municipality of Clarington

CHAPTER 7 DEVELOPMENT STANDARDS

Section 7.02 Lighting Standards

PD-32: Light Pollution

Draft Dark Sky Ordinance. This chapter shall be known as the Malibu Dark Sky Ordinance.

Monterey Downtown Lighting Strategy

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

Landscape and Streetscape Design 2.5

WHEREAS, the Board has determined that the adoption of this Local Law will not have a significant negative impact upon the environment;

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

C HAPTER 7: S TREETS, P ARKING & L IGHTING

Design Guidelines for Exterior Lighting

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

How Photometric Design Enhances Energy Savings and Asset Management

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

ORDINANCE NO. 14,767

Community Sensitive Lighting

The purpose of the requirements in this Article is to provide for landscaping and screening of parking and other outdoor areas that will:

Outdoor Lighting for Julian Dark Sky Network, 2/10/18. Paul Ericson, PE San Diego IDA Board Member / Design Principal, Stantec

a. Sample Streets b. Technical Sketches c. Product Information d. Proposed Dark Skies By-law e. Proposed Sign By-law f. Public Consultation

ORDINANCE. WHEREAS, the Local Planning Agency of the Town of Davie held a public hearing on the night sky regulations on December 10, 2008; and

Lighting Design Criteria: Codes and Standards

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

LANDSCAPE ORDINANCE PASADENA PLANNING DEPARTMENT (713) FAX (713)

Global Tech LED 8901 Quality Rd Bonita Springs, FL, Fuel Station Lighting Solutions

SITE PLAN GUIDELINES Effective November 1, 2000

ARTICLE RRCO RED ROCK CORRIDOR OVERLAY DISTRICT

Lindsey Beane. Executive Summary

BUILDING DESIGN STANDARDS FACILITIES MANAGEMENT AND ANCILLARY SERVICES EXTERIOR IMPROVEMENTS DIVISION 32 Exterior Lighting

SECTION 1000 HIGHWAY CORRIDOR OVERLAY DISTRICT REGULATIONS

CHAPTER SPECIAL PURPOSE AND OVERLAY ZONING DISTRICTS

Chapter SAR, SENSITIVE AREA RESORT ZONE

VALLEY COUNTY MINIMUM STANDARDS FOR PRIVATE ROAD DESIGN AND CONSTRUCTION

Lighting Depth Part 1: Exterior Space

ARTICLE 9: LANDSCAPING AND FENCING REQUIREMENTS

City of Bonner Springs, Kansas

Building Exterior Lighting Grant Program. Applications will be reviewed April 1, July 1 and October 1, 2019

PROTECTION. Chapter 1050 LIGHT POLLUTION

ARTICLE IX SPECIAL PERMIT USES

F. Driveways. Driveways which provide access to off-street parking or loading from public streets shall comply with the following:

The Highway Overlay District applies to an area within the City of Papillion's zoning jurisdiction described as:

BUG stands for Backlight, Uplight and Glare. The acronym

COMMUNITY DEVELOPMENT DEPARTMENT

VILLAGE OF SKOKIE Design Guidelines for Mixed-Use Districts NX Neighborhood Mixed-Use TX Transit Mixed-Use CX Core Mixed-Use

MEDWAY PLANNING BOARD MINOR SITE PLAN PROJECTS Application Guidelines

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Guidelines for Municipal Streetlighting in the Right of Way

5.7 Design Criteria for the Private Realm Organization of Private Realm Design Standards and Guidelines Guidelines vs.

ARTICLE XII BUFFER REQUIREMENTS

Technical Report One

STREET LIGHTING CATALOGUE

DESIGN REVIEW STANDARDS CITY OF LANGLEY

CHAPTER ADDITIONAL REQUIREMENTS IN THE NC, NEIGHBORHOOD COMMERCIAL ZONE

Section: TABLE OF CONTENTS Lighting. 07.A General B Lighting Levels Minimum Lighting Requirements

Sidewalks Street Lights

Article VII. Article VII. Development Site and Subdivision Design. Contents [DRAFT - 06/16/2014]

Commercial Site Plan Review Checklist

CITY OF KEIZER MASTER PLAN APPLICATION & INFORMATION SHEET

Chapter Master Planned Communities (MPC) District

Design Guidelines for the Route 30 Corridor Master Plan: Subdivision and Land Development Elements

PARKLET PROPOSAL PACKAGE & PROCESS

BE IT ORDAINED by the Council of the City of Newport News, Virginia:

SITE PLAN REVIEW PROCESS

FREEWAY/TOURIST DISTRICT

REPRINT OF THE CITY OF ERIE ZONING ORDINANCE WATERFRONT CONDITIONAL USE REQUIREMENTS

PLANNING APPROVAL & PLANNED UNIT DEVELOPMENT Date: April 6, 2017

ORDINANCE NO /2008

CHAPTER 10 GC GENERAL COMMERCIAL DISTRICT

A BILL FOR AN ORDINANCE TO AMEND CHAPTER 9, KAUAI COUNTY CODE 1987, RELATING TO STREET REQUIRE:MENTS FOR SUBDIVISIONS

Appendix I Lighting Evaluation

ARTICLE LANDSCAPING, LIGHTING AND SIDEWALKS

TOWN OF BAY HARBOR ISLANDS PLANNING AND ZONING BOARD

The Brown Road Innovation Zoning District shall be specified for the areas as designated on the Charter Township of Orion Zoning Map.

Glenborough at Easton Land Use Master Plan

CHAPTER 21 NC-PUD NEIGHBORHOOD COMMERCIAL PUD DISTRICT

D. Landscape Design. 1. Coverage Intent: To provide adequate landscaping materials that enhance the appearance of development projects.

Chapter 19.5 LANDSCAPING REQUIREMENTS

2005 Title 24 Outdoor Lighting Regulations Overview. 77 slides

DEVELOPMENT STANDARDS

City of Brantford. Site Plan Manual. Technical Standards

CITY PLAN COMMISSION STAFF REPORT

Transcription:

BIRMINGHAM TOWNSHIP CHESTER COUNTY, PENNSYLVANIA Subdivision and Land Development Ordinance No. 0302 Dated 02/18/03 Section 103-40. OUTDOOR LIGHTING A. Purpose. The standards in this section shall require and set minimum standards for outdoor lighting in order to: (1) Provide for and control lighting in outdoor public places where public health, safety and welfare are potential concerns. (2) Protect drivers and pedestrians from the disabling glare of non-vehicular light sources. (3) Protect neighbors and the night sky from nuisance glare and light trespass from poorly shielded, aimed, placed, applied or maintained light sources. (4) Promote energy efficient lighting design and operation. (5) Protect and retain the intended character of Birmingham Township. B. Applicability (1) Outdoor lighting shall be required for safety and personal security for uses that operate during hours of darkness where there is public assembly and/or traverse, including but not limited to the following: commercial, industrial, public-recreational, institutional and multi-family residential developments. (2) The Board of Supervisors may, in its sole discretion, require lighting be incorporated for other uses or locations or may restrict lighting in any of the above uses, as deemed necessary. (3) The glare-control requirements herein contained apply to lighting in all above-mentioned uses as well as, but not limited to, sign, architectural, landscape, recreational, and residential lighting. (4) Temporary decorative lighting is exempt from all but the glare control requirements of this Ordinance. C. Definitions (1) Footcandle a unit of incident light quantity measurable with an illuminance meter, a.k.a. footcandle meter or light meter. (2) Full Cutoff - a term used by the lighting industry to describe a lighting fixture from which no light is emitted at or above a horizontal plane drawn through the bottom of the fixture and no more than 10% of the lamp's light intensity is emitted at an angle 10 degrees below that horizontal plane, at all lateral angles around the fixture. (3) Glare the sensation produced by excessive direct or reflected light that causes annoyance, discomfort or loss in visual performance to the eye. Glare is subjective and cannot be measured with a meter. (4) Illuminance the quantity of incident light per unit area, measured with a light meter in footcandles (or lux). (5) Light Trespass the light created by a lighting installation, which extends beyond the boundaries of the property on which the installation is sited. (6) Lumen the light-output rating of a lamp (light bulb), as used in the context of this Ordinance.

D. Criteria (1) Illumination Levels (a) (b) Lighting, where required or permitted by this Ordinance, shall have intensities and uniformity ratios in accordance with the recommended practices of the Illuminating Engineering Society of North America (IESNA) as contained in the IESNA Lighting Handbook, 9th Edition or subsequent editions, or as contained in current publications of the IESNA Recommended Practices or Design Guides. The intensity of illumination projected onto a residential property from anther property shall not exceed 0.1 vertical footcandle measured line-of-sight from any point on the adjacent residential property. (2) Lighting Fixture Design (a) Fixtures shall be of a type and design appropriate to the lighting application and aesthetically acceptable to the Township. (b) For the lighting of predominantly horizontal surfaces such as, but not limited to, roadways, areas of vehicular and pedestrian passage, merchandising and storage areas, automotive-fuel dispensing facilities, automotive sales areas, loading docks, cul-de-sacs, active and passive recreational areas, building entrances, sidewalks, paths, site entrances and parking areas, fixtures shall be aimed straight down and shall meet IESNA full-cutoff criteria, unless the aggregate wattage per-fixture does not exceed the output of a standard 60-watt incandescent lamp, in which case non-cutoff fixtures shall be permitted. (c) For the lighting of non-horizontal surfaces such as, but not limited to, facades, landscaping, signs, fountains, displays, flags and statuary, the use of lighting not meeting IESNA full cutoff criteria shall be permitted only with the approval of the Board of Supervisors or its designee, based upon acceptable glare control (approval shall not be required if the aggregate wattage per fixture does not exceed the output of a standard 60-watt incandescent lamp, i.e. 1000 lumens). (d) Barn lights, aka dusk-to-dawn lights, shall not be permitted where they are visible from other uses or properties, unless fitted with a reflector or shield to render them full cutoff. E. Installation (1) Electrical feeds for fixtures mounted on poles shall be run underground, not overhead. (2) Lighting standards to the rear of parking spaces shall be placed a minimum of five (5) feet outside paved area, curbing or tire stops, or on 2

concrete pedestals at least thirty (30) inches high above the pavement, or suitably protected by other approved means. (3) Fixtures meeting IESNA full-cutoff criteria shall not be mounted in excess of twenty (20) feet above finished grade of the area being illuminated. (4) Fixtures not meeting IESNA full-cutoff criteria shall not be mounted in excess of sixteen (16) feet above grade of the area being illuminated. F. Maintenance Lighting fixtures and ancillary equipment shall be maintained so as always to meet the requirements of this Ordinance. G. Recreational Lighting (1) When facilities for outdoor recreational activities (such as, but not limited to, baseball, tennis, football and miniature golf), are specifically permitted by the Township for operation during hours of darkness, excluding recreational accessory uses which are permitted on properties in the RA, A-RT, R-1 and R-2 zoning districts, the following lighting requirements shall apply: (a) Lighting shall be accomplished only through the use of fixtures conforming to IESNA full-cutoff criteria, or as otherwise approved by the Township based on suitable control of glare and light trespass. (b) For new recreational facilities and recreational facilities wishing to change their hours of operation during hours of darkness, sporting events shall be timed so that all lighting in the sports facility, other than lighting for safe exit of patrons, shall be extinguished by 10:00 p.m., regardless of such occurrences as extra innings or overtimes. (c) Golf driving ranges and trap shooting facilities shall not be artificially illuminated. (d) The foregoing outdoor recreational activities shall not be illuminated if located within any residential district or sited on a nonresidential property located within 1200 feet of a residential use. (e) Maximum mounting heights for recreational lighting shall be in accordance with the following: [1] Basketball 20 H. Plan Submission [2] Football 70 [3] Soccer 70 [4] Little League Baseball (a) 200 Radius 60 (b) 300 Radius 70 [5] Miniature Golf 20 [6] Tennis 20 [7] Track 20 3

(1) For subdivision and land-development applications where site lighting is required or proposed, lighting plans shall be submitted to the Township for review and approval with any preliminary or final subdivision/landdevelopment plan application and with any conditional use, special exception, variance application or any building permit where requested, and shall include: (a) (b) (c) (d) A site plan, complete with all structures, parking spaces, building entrances, traffic areas (both vehicular and pedestrian), vegetation that might interfere with lighting, and adjacent uses that might be adversely impacted by the lighting, and a layout of all proposed fixtures by location, mounting height and type. The submittal shall include in addition to area lighting, exterior architectural lighting, building-entrance lighting, landscape lighting, etc. 10 x10 illuminance-grid (point-by-point) plot of maintained footcandles, plotted out to 0.0 footcandles, which demonstrates compliance with the light trespass, intensity and uniformity requirements as set forth in this Ordinance or as otherwise required by the Township. The lamp lumen rating and type, maintenance (light-loss) factors and IES file names used in calculating the illuminance levels shall be documented on the plan. Description of the proposed equipment, including fixture catalog cuts, photometrics, glare reduction devices, lamps, on/off control devices, mounting heights, pole foundation details and mounting methods. Plan Notes The following notes shall appear on the lighting plans: [1] Post-approval alterations to lighting plans or intended substitutions for approved lighting equipment shall be submitted to the Township for review and approval. [2] The Township reserves the right to conduct post-installation nighttime inspections to verify compliance with the requirements of this Chapter, and if appropriate, to require remedial action at no expense to the Township. [3] Applicant shall identify the following items in a Not: (1) the date and edition of the IESNA Manual which was in effect when the land development application was approved; (ii) the specific lighting criteria (intensity, illumination levels and uniformity ratio) that applied to the development as contained in the IESNA Handbook or Recommended Practices or Design Guides that were in effect when the application was approved. (2) When requested by the Township, applicant shall also submit a visualimpact plan that demonstrates appropriate steps have been taken to 4

mitigate on-site and off-site glare and light trespass and taken to retain the Township s intended character. 5