AGF Manufacturing Inc.

Similar documents
D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

AGF Manufacturing Inc. Inspector's Test and Drain Valves for Residential and Commercial Wet Fire Sprinkler Systems

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Gas Station & C Store SECTION CWM Job No

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

SPRINKLERS TABLE OF CONTENTS

WET-PIPE SPRINKLER SYSTEMS

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Model F3 Dry Sprinklers

A. This section includes design and performance information for fire protection and suppression systems.

TECHNICAL DATA. 319a. January 27, 2012

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

TECHNICAL DATA OBSOLETE

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

Model 5100A, 5200A, and 5100ALBV Owner s Manual

Cater Hoses. Manufactured to BS669 PT2: /2 & 3/4 Braided Cater Hose with Lanyard - Quick Release

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

Intelligent Refrigeration Solutions

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

InterSeptor Centrifugal Separators Operating & Maintenance Manual

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

TOTALPAC2 Integrated Fire Protection System

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

Gas Range Catalogue. Tel: +44 (0) Fax: +44 (0) Website:

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION

PATENTED TECHNOLOGY THE CORE OF ANY PROFESSIONAL HYDRONIC INSTALLATION

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

10.85 VicFlex Sprinkler Fittings

water source / fan coils

Model F1FR Series Quick Response Standard Spray

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Design and Construction Standards SECTION PLUMBING EQUIPMENT

A. This Section includes the following domestic water piping specialties:

standard response dry horizontal sidewall sprinklers

SECTION DRY-PIPE SPRINKLER SYSTEMS

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

quick response Sprinkler 105a October 25, 2010

ALARM VALVE MODEL: SDH-AVA TECHNICAL DATA : OPERATION DESCRIPTION. Flange X Groove Groove X Groove Bar (250 PSI)* WORKING PRESSURE

Discontinued Product

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

esfr dry pendent sprinkler Vk501 (k14.0)

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

SECTION DRY-PIPE SPRINKLER SYSTEMS

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Environmental Health & Safety

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

North Hanover Township School District North Hanover Township, New Jersey

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

technological solutions LIST PRICE BOOK Building the Future Together Effective November 1, 2016 All Prior Issues Void PL-CIM_V0013.

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

esfr dry pendent sprinkler Vk502 (k14.0)

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

TECHNICAL DATA OBSOLETE

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

Davies Carries Parts for MF & SF Series Glycol Feeders

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Flow Control for Fire Protection

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Transcription:

AGF Manufacturing Inc. Manual and Automatic Air Venting Valves BR-PURGEnVENT_2019 1/19 Reliability, Versatility, Code Compatibility

PURGEnVENT AIR VENTING VALVES NFPA 13 (2016) standard requires the addition of an air vent on each wet fire sprinkler system to help mitigate internal pipe corrosion. PURGEnVENT Air Venting Valves are designed to work alone or in tandem to eliminate as much excess air from the wet fire sprinkler system as possible. NFPA 13 (2016) 7.1.5 Air Venting A single air vent with a connection conforming to 8.16.6 shall be provided on each wet pipe system utilizing metallic pipe. 8.16.6* Air Venting The vent required by 7.1.5 shall be located near a high point in the system to allow air to be removed from that portion of the system by one of the following methods: Manual valve, minimum 1/2 (15mm) size Automatic air vent Other approved means www.purgenvent.com

MANUAL AIR VENTING VALVES Model 7910MAV The PURGEnVENT Model 7910 is a Manual Air Vent (MAV) for wet fire sprinkler systems. The Model 7910MAV is designed to exceed NFPA 13 standard that requires a single air vent be provided on each system utilizing metallic pipe. To vent air, open the Model 7910MAV while the system is being filled and close the valve when the system is full. While the system is in operation the Model 7910MAV can be opened and closed in rapid succession to vent any remaining air from the system; keep the M7910MAV closed during normal system operation. AGF recommends installing the M7910MAV at the end of system branch lines, at the highest and furthest points of the system, and at the top of supply risers. The M7910MAV can also be used as a vacuum break while draining the system. Installation Locations 1. 2. Ball Float Strainer Screen 1 2 Item ID 7910MAV Item Description 1/2 Manual Air Vent (MAV) NOTE: Factory Mutual does not offer an approval standard for manual air venting valves. AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com

PURGEnVENT AUTOMATIC AIR VENTING VALVES Model 7900AAV The PURGEnVENT Model 7900 is an Automatic Air Vent (AAV) for wet fire sprinkler systems. The Model 7900AAV is designed to exceed NFPA 13 standard that requires a single air vent be provided on each system utilizing metallic pipe. The patent-pending, one-piece isolation valve includes a purge valve with hose connection, strainer, and automatic air vent. To purge air from the system while it is being filled attach a hose to the purge valve s outlet and open the valve while the system is being filled. Close the purge valve when the system is filled and the automatic air vent will continue to vent excess air while the system is in operation. Close the isolation valve and remove the purge valve at the union to clean the strainer. By opening the purge valve the M7900AAV can also be used as a vacuum break while draining the system. AGF recommends installing the M7900AAV at the end Installation Locations of system branch lines. 6 5 7 8 1 1. Patented, FM Approved, UL Listed M7900V Air Release Valve. 2. Forged brass body with 1 NPT isolation valve. 3. Stainless Steel 20 mesh strainer. 4. Adjustable purge valve with hose connection, thread cap, and lanyard. 2 3 4 5. 6. Unique conical shape maximizes clearance to protect valve from contamination. Recessed venting valve prevents damage to vent mechanism and float. 7. Single float on rigid shaft only allows vertical movement. 7610-2281 : 0500 8. Bubble Breaker aids in the passage of air to the vent and acts as a secondary filter. Item ID 7900AAV Item Description 1 Automatic Air Vent (AAV)

AUTOMATIC AIR VENTING VALVES Model 7930ECA The PURGEnVENT Model 7930ECA is a Automatic Air Vent for wet fire sprinkler systems. The Model 7930ECA takes the UL Listed Model 7900 Automatic Air Vent (AAV) and adds a close nipple and end cap for easy installation onto the end of system branch lines. Install the M7930ECA at the end of system branch lines. Installation Locations 1 2 1. Patented, FM Approved, UL Listed M7900V Air Release Valve. 2. UL Listed, 1 NPT isolation valve with stainless steel 20 mesh strainer and adjustable purge valve with hose connection, thread cap, and lanyard. 3. UL Listed, FM Approved, standard groove connection end cap with close nipple. 3 Sizes: 7610-2281 : 0500 2 2½ 3 4 6 8 Item ID 7930ECA-20 7930ECA-25 7930ECA-30 7930ECA-40 7930ECA-60 7930ECA-80 *Coupling not included Item Description 1 Automatic Air Vent with 2 End Cap* 1 Automatic Air Vent with 2½ End Cap* 1 Automatic Air Vent with 3 End Cap* 1 Automatic Air Vent with 4 End Cap* 1 Automatic Air Vent with 6 End Cap* 1 Automatic Air Vent with 8 End Cap* AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com

PURGEnVENT AUTOMATIC AIR VENTING VALVES Model 7950ILV The PURGEnVENT Model 7950 is an Inline Vent (ILV) for wet fire sprinkler systems. The Model 7950ILV is designed to exceed NFPA 13 standard that requires a single air vent be provided on each system utilizing metallic pipe. When filling the system the large diameter of the separation chamber allows the water to drop to the bottom and the air to rise up through the Air Scoop and be released by the UL Listed, FM Approved M7900V. As water exits the separation chamber it is reduced back to the supply line s diameter which pushes air back towards the chamber. The remaining air is pushed up the back side of the air scoop through it s quick vent channel where it is released through the M7900V. To purge air from the system while it is being filled attach a hose to the purge valve s outlet and open the valve while the system is being filled. Close the purge valve when the system is filled and the automatic air vent will continue to vent excess air while the system is in operation. Close the isolation valve and remove the purge valve at the union to clean the strainer. By opening the purge valve the M7900AAV can be used as a vacuum break while draining the system. AGF recommends installing the M7950ILV after the floor control assembly. If extra space is needed the separation chamber can be turned 45 to create additional vertical space. 3 4 1 2 Sizes: 2 2½ 3 4 6 8 1. Patented, FM Approved, UL Listed M7900V Air Release Valve. 2. Forged brass body with 1 NPT, UL Listed isolation valve. 3. Air Scoop with Patent Pending Quick Vent Channel. 4. Separation Chamber. Air Scoop Patent Pending Quick Vent Channel 7610-2281 : 0500 Item ID 7950ILV-20 7950ILV-25 7950ILV-30 7950ILV-40 7950ILV-60 7950ILV-80 Item Description 2 Collection Chamber and Air Scoop with M7900 Automatic Air Vent 2½ Collection Chamber and Air Scoop with M7900 Automatic Air Vent 3 Collection Chamber and Air Scoop with M7900 Automatic Air Vent 4 Collection Chamber and Air Scoop with M7900 Automatic Air Vent 6 Collection Chamber and Air Scoop with M7900 Automatic Air Vent 8 Collection Chamber and Air Scoop with M7900 Automatic Air Vent

Dimensions & Orientation Typical Installation Orientation Alternative Installation Orientation ITEM ID SIZE A B (EST.) C (EST.) L ITEM ID SIZE A B (EST.) C (EST.) L 7950A-20 2 2 3/8 [60] 5 1/4 [133] 11 1/8 [283] 14 [356] 7950A-40 4 4 1/2 [114] 6 1/4 [160] 12 1/8 [309] 14 [356] 7950A-25 2 1/2 2 7/8 [73] 5 1/2 [140] 11 3/8 [289] 14 [356] 7950A-60 6 6 5/8 [168] 7 7/8 [198] 13 3/4 [348] 18 [457] 7950A-30 3 3 1/2 [89] 5 3/4 [146] 11 5/8 [295] 14 [356] 7950A-80 8 8 5/8 [219] 8 7/8 [225] 14 3/4 [375] 18 [457] Installation Locations AGF Manufacturing Inc. Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com

AGF Manufacturing Inc. 100 Quaker Lane Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.agfmanufacturing.com