PROFESSIONAL AIR MOVER OWNER S MANUAL

Similar documents
OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

P-200T / P-200AT / P-230AT (115V / 60Hz)

LOW PROFILE AIR MOVER

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

1 HP Air Mover. Owner s Manual

Model: B-55 (115V/60Hz)

AIR SCRUBBER OWNER S MANUAL

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

BIG BEAR VORTEX FAN MODEL #BB-2

Phoenix AirMAX - Radial Air Mover

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

owner s manual & parts list

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

AIR SCRUBBER X-3400, X-3500, X-3700

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

OmniDry 2.9 Amp Centrifugal Air Mover

MODEL:PUMA X 3-SPEED AIR MOVER

Zeus Extreme Owner's Manual

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

HEATER. Fan Forced IMPORTANT INSTRUCTIONS READ & SAVE OWNER S MANUAL. Model No.: DR W 120V 60Hz DR W 240V 60Hz

MODEL # PUMA G, 3-SPEED TRANSPORTABLE AIR MOVER

Thanks for shopping with Improvements! Quartz Comfort Furnace Heater Item #470295

22In. Oscillating Pedestal Fan. Owner s Manual

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

ELECTRIC STOVE HEATER Models: FS2213B

The Family Ceramic Heater

Infrared Portable Space Heater

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

Gallery Electric Fireplaces

AH-600 Baseboard Heater

Low Profile. Baseboard Heater

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

Electric Garage Heater

CLASSIC PLUS INFRARED ZONE HEATER

Quest Power Electric Heat EHS 62 Pro

FAN-FORCED UTILITY HEATER

Infrared Portable Space Heater

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

SOUTHERN ENTERPRISES INC.

INFRARED ZONE HEATING SYSTEM

Gallery Electric Fireplaces

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

9 TWIN WINDOW FAN MODEL: FW23-A1 SKU:

IMPORTANT SAFETY INFORMATION:

NO VENTING REQUIRED 120V AC;

With Remote Control. English

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

IMPORTANT SAFETY INFORMATION

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Quest PowerHeat HFC 100 Pro

Dr. Infrared Heater Elite Series

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

Operation and warranty Manual

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

PERSONAL SIZE FIREPLACE

AirInstinct Air Purifier

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Operator s Manual. Commercial Dryer/Air Mover. Standard Models PD350, PD500, PD750. A Tacony Company

20" Air Circulator MODEL: FB50-9HA

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

ELECTRIC FLAT PANEL FIREPLACE HEATER

ELECTRIC FIREPLACE OWNER S MANUAL

IMPORTANT SAFETY INFORMATION:

Operating Instructions & Parts Manual Models 99533, 99532

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

INFRARED ZONE HEATING SYSTEM

portable heater FAN Set up and Operating Instructions

Owner s Manual Phoenix Aquadry TX 200

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

IMPORTANT SAFETY INFORMATION:

EVAPORATIVE AIR COOLER SERVICE MANUAL

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Radiant Heater. Instruction Manual QH-200 N13275

Quest Power Electric Heat EHS 31 Pro

AH-400 Oil Filled Personal Heater

Owner s Manual Phoenix FireBird

20 High Velocity Fan with 135 Tilt Head

Landis Fume Buster 3, 4 & 5 Foot

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

STAINLESS STEEL ELECTRIC KETTLE

User s Manual & Operating Instructions

THANK YOU FOR PURCHASING A B-AIR PRODUCT.

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

Motion Sensor Oscillating Heater with Digital Control

16 OUTDOOR MISTING FAN

IMPORTANT SAFETY INSTRUCTIONS

ELECTRIC FIREPLACE CONVERTER KIT OWNERS MANUAL Model Number: EF05-23

ELECTRIC FLAT PANEL FIREPLACE HEATER

ULTRASONIC HUMIDIFIER

Instruction Leaflet. Read instructions before operating. Retain for future reference.

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Wall Mount Electric Fireplace

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Transcription:

X-600/ X-600A/ X-630 P-600/ P-630 (115V/230V) PROFESSIONAL AIR MOVER OWNER S MANUAL X-600 / X-600A / X-630 P-600 / P-630 XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USA Tel: 626-285-3301, Fax: 626-285-3302 www.xpower.ws PLEASE READ AND SAVE THESE INSTRUCTIONS

Index Introduction... 2 Operation / Instructions... 3 Safety Instructions... 4 Maintenance Instructions / Troubleshooting... 5 Specifications... 6 Warranty / Service... 7 Parts List... 8 Daisy Chain Specifications / Accessories... 9 Warranty Registration Form... 10

Introduction XPOWER Air Movers are ETL/CETL/CE/GS certified and multifunctional Air Mover with the most efficient engineering design. All XPOWER Air Features: Low power draw with a velocity over 2400 CFM when switch on High. Super quiet and super light weight. Optional Easy clean filter system. Easy carrying and storage stackable. Easily disassembled for thorough cleaning and service. Power cord lengths are 20 /25 in US and 10 for Canada Easy cord wrap on handle Safety screens on open vents. 3 speed switch. 4 air flow positions (0, 20, 45, 90 ). 0 20 45 90 Durable and rugged housing with 5 Years Warranty.

Operation / Instructions XPOWER Air Movers are intended to move air and to dry floors, walls, furniture, etc. Durable and easy to operate with an effective balance of static pressure and airflow, the units are suitable for a variety of applications. 1. XPOWER Air Movers are shipped ready to be put into service. Prior to plugging the unit into the power source, inspect completely for any shipping damage. 2. Plug the electrical cord into the power outlet. 3. Carefully place the Air Mover unit on a stable, flat dry surface. 4. The unit has four air flow positions, capable to aim airflow across flat surfaces or angled upward. 5. Turn the switch to desired speed and make sure it is operating correctly. 6. All Air Movers in operation must be supervised at all times. AIR MOVER STORAGE: Air Movers can be stacked (up to 4) on their sides for storage. NOTICE: 1.Stacking feature is not secure for transportation. 2.Remove the filters before stacking.

Safety Instructions 1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit with wet hands or while standing in water. 2. To avoid risk of injury, do not direct air flow at face or body. 3. To reduce the risk of fire or electric shock, do not use the Air Mover with any solid-state speed control device. 4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary. 5. Do not operate any Air Mover with a damaged cord or plug. Discard the unit or return it to an authorized service facility for examination and/or repair. 6. Unplug the Air Mover from the power supply before servicing or cleaning. 7. Do not run the power cord under carpeting. Do not cover the power cord with throw rugs, runners, or similar coverings. Place the power cord away from traffic area to prevent tripping. 8. Do not allow children to play with or around an Air Mover at any time. 9. Do not move or carry an Air Mover while unit is operating. 10. All Air Movers in operation must be supervised at all times.

Maintenance Instructions 1. To keep the Air Mover clean, use a damp cloth to wipe the surface of the housing. 2. Never clean the Air Mover with water. 3. When not in use, unplug and store the Air Mover in a dry indoor place out of reach of children. 4. Always disconnect the Air Mover from its power source before performing any maintenance or cleaning. 5. Clean the filters (optional item) as often as necessary to avoid loss of airflow. Troubleshooting For any problems not listed below, call your local distributor or contact our Service Department. PROBLEM POSSIBLE CAUSE SOLUTION No power input Plug in the Air Mover; check circuit breaker Air Mover not running Air over vibrates excessively Switch not turned on Air Mover fan wheel jammed Intake or exhaust blocked Turn on switch Remove material jamming fan wheel Turn unit off and allow to cool, then remove blockage Accumulation of dirt on fan blades Clean Air Mover fan blades

Specifications Model X-600 P-600 X-600A X-630 P-630 Power 1/3 hp 1/3 hp 1/3 hp 1/2 hp 1/2 hp Amp 3.8 A 3.8 A 3.8 A 5 A 5 A Weight 20 lbs 19 lbs 20 lbs 21 lbs 20 lbs Speeds Three Three Three Three Three Size (H x W x D) 16 x 16 x 16 in. 16 x 16 x 16 in. 16 x 16 x 16 in. 16 x 16 x 16 in. 16 x 16 x 16 in. Daisy Chain N.A N.A YES N.A N.A Cord Length 25 ft 20 ft 25 ft 25 ft 20 ft Overheating Protecting Thermally Protected Thermally Protected Thermally Protected Thermally Protected Thermally Protected Rated Airflow (on high) 2400 CFM 2400 CFM 2400 CFM 2800 CFM 2800 CFM Positions 4 (0, 20, 45, 90 ) 4 (0, 20, 45, 90 ) 4 (0, 20, 45, 90 ) 4 (0, 20, 45, 90 ) 4 (0, 20, 45, 90 ) Housing ABS PP ABS ABS PP Safety Marks ETL / C-ETL ETL / C-ETL ETL / C-ETL ETL / C-ETL ETL / C-ETL Filter System Optional Optional Optional Optional Optional

XPOWER LIMITED WARRANTY XPOWER Warranty covers the unit from defects in materials and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. The XPOWER Air Mover Housing is covered for a term of five years from the date of original purchase. Important! Warranty does not cover signs of misuse including, but not limited to, a unit that has been dropped, subjected to water damage, tampered with, improper voltage use and unauthorized maintenance and repairs. The POWER CORD and FILTERS are not covered by the warranty. Service In order to receive service or replacement parts under warranty, you must: A. Must Call for a Return Merchandise Authorization (RMA) number through Service Department and obtain ship back instructions. B. Must have original proof of purchase. C. Must use original none damaged packaging or Industrial certified packaging method. The end user will be responsible to ship the unit (with the RMA number showing on the shipping label) to the XPOWER Service Department. Upon inspection, we will advise you of the repairs needed and the cost (if applicable). XPOWER will provide repair or replacement parts depending on warranty. - 7 -

600 Series Parts List Item No. Parts Name Item No. Parts Name 600-1 Left Housing 600-2 Grid Cover (Motor Side) 600-3 Switch Plate 600-4 Switch Knob 600-5 Switch Plate 600-6 Motor 600-7 Right Housing 600-8 Power Cord 600-9 Fan 600-10 Grid Cover (Fan Side) 600-11 Air Outlet Grid Cover 600-12 Kick Stand 600-13 Filter I (Motor Side) 600-14 Filter II (Fan Side) 600-15 Rubber Feet (Not Shown) 600-16 Screws and Nuts (Not Shown) 600-17 Capacitor - 8 -

Daisy Chain Specifications (applicable for model X-600A) XPOWER Air Mover Model X-600A is daisy chainable with a low 3.8 amp draw. The 12-amp on-board circuit breaker will allow two (2) additional X-600A units to run on one circuit at the same time. Filters (optional) Note: Air Mover has an on-board circuit breaker. If the auxiliary outlet overloads, the circuit breaker will trip. If the breaker trips, unplug the units and press the circuit breaker reset button. Plug the units back into the power source and turn on the switch. Accessories A set of filters is available for the XPOWER Air Mover which will help prevent small debris and dust from entering the Air Mover. To clean the filters: remove filters from the unit and wash with warm soapy water, rinse with clean water and let dry thoroughly before reinstalling. Installation: Filters snap into the air inlets. Note: Filter I is for the Motor side, Filter II is for the Fan side Filter Removal: Pull the filters out of the blower. Note: After cleaning make sure the filters are dry before installing. - 9 -

WARRANTY REGISTRATION Please complete and mail or fax for your product warranty. F or a multiple units, please list serial numbers on a separate sheet of paper. Address: XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USA Tel: (626) 285-3301; Fax: ( 626) 285-3302 Company Name / Contact Person / Title Address City State / Province Zip Country Phone Fax E-mail Model # Serial #: Date of Purchase / / Purchased From Additional Comments / Suggestions

From: TO: XPOWER MANUFACTURE, INC. 220 Clary Avenue San Gabriel, CA 91776, USA Tel: (626) 285-3301; Fax: (626) 285-3302