REPORT DOCUMENTATION PAGE

Similar documents
Direct measurement of the aerosol absorption and extinction cross section for a variety of chemical and biological simulants in the LWIR

Vision Protection From Lasers Overview for Dr. Beagley, Australia

Gamma-ray Irradiation Effects on InAs/GaSb-based nbn IR Detector

The Conservation Fund The Center for Conservation and Development

A Novel Approach for a Hostile Arms Fire Sensor

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

REPORT DOCUMENTATION PAGE

Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments

Low Impact Development at Naval Facilities: Opportunities and Constraints

Industrial Workshop Gettysburg, PA February 26, 2004

MINIMUM PERFORMANCE REQUIREMENT FOR AIR FORCE FLIGHTLINE FIRE EXTINGUISHERS:

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

ECBC SBIR/STTR Projects. ECBC SBIR/STTR MSCoE STRF Conference

FIRE PROTECTION FOR. Dist A. MILITARY GROUND VEHICLES. Steve McCormick US Army RDECOM-TARDEC.

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Force Protection Joint Experiment (FPJE) Battlefield Anti-Intrusion System (BAIS) Sensors Data Analysis and Filtering Metrics

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

Room Temperature MWIR FPAs: Return of the Lead Salts?

InAsSb detectors for visible to MWIR high operating temperature applications

Sustainability Criteria for Planning, Constructing, and Operating Contingency Bases

IEEE JOURNAL OF QUANTUM ELECTRONICS, VOL. 46, NO. 6, JUNE /$ IEEE

Design Considerations for Abrasive Blast Rooms & Recovery Systems

BRITE II Characterization and Application to a New Advanced Flight Motion Simulator

EVALUATION OF FIKE CORPORATION S EXPLOSION SUPPRESSION SYSTEM FOR ULTRA-HIGH SPEED FIRE SUPPRESSION APPLICATIONS

T2SL production and development at IRnova from MWIR to VLWIR detection

InAs/Ga(In)Sb superlattice based infrared detectors using nbn design

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

AFRL-RB-WP-TR

HANTAVIRUS PREVENTION: CLEANUP OF RODENT CONTAMINATION

SEMICONDUCTOR LASERS. Second Edition. The Institute of Optics, University of Rochester Rochester, New York. and. Niloy K. Dutta

Understanding total measurement uncertainty in power meters and detectors

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

lighting control systems Division - Name - Date - Language 1

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

T2SL technology for Mid-IR detectors

Optical Properties of Blocking Glass in the WFC3 IR Channel

Temperature dependent Components within the Pyroelectric Detector

Uncooled operation of IR photodetectors

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Semiconductor Radiation Detectors

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Distribution Restriction Statement

Separation of the Pyro- and Piezoelectric Response of Electroactive Polymers for Sensor Applications

A MICROCOMPUTER-BASED LIFE-SAFETY MONITORING SYSTEM FOR ELDERLY PEOPLE

TESTS OF ADSIL COATING

Tatsuya Yamaguchi, Hiroshi Ohno, Yu Matsumoto, Taiyo Matsumura, Yukitaka Shinoda, Takashi Ono Nihon University, Tokyo, Japan

MULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING

Effect of Contamination on the Sensitivity of Optical Scatter Smoke Sensors

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

Establishing a Center of Excellence for. Security Science and Engineering

Publication American Institute of Physics. Reprinted with permission.

Infrared Technology And Applications Xxviii (Proceedings Of Spie)

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

IMPLEMENTATION OF A NOVEL STRUCTURAL HEALTH MANAGEMENT SYSTEM FOR STEEL BRIDGES

Sensor Grand Challenges: An NVESD Perspective

Highly Near-Infrared-Sensitive, Printed Flexible Thermistors. Austin Shearin ext Brewer Science Inc.

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

by Richard W. Bukowski Center for Fire Research Program for Fire Detection and Control Systems National Bureau of Standards Washington,

Exercise 1: IR Transmission and Reception

Scholars Research Library

Measurement system for detection of Radon in building

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Remote Helium Cooling Loops for Laboratory Applications

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

Imaging detection of CO 2 using a bispectral type-ii superlattice infrared camera

TECHNICAL REPORT NATICK/TR-17/015

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

REPORT DOCUMENTATION PAGE

Technological developments in infrared imaging: a fast growing market Dr. François Simoens, CEA-Leti, Marketing & Strategy Manager

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Dedicated Closed Circuit Hydrostatic Fan Drive Control

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

Assessing Directly Connected Impervious Areas in Residential Subdivisions in Western Sydney, NSW

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

Low-frequency noises as a tool for UV detector characterisation

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Autonomous Wide Aperture Cluster for Surveillance (AWACS) WHOI Component

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

EAT 212 SOIL MECHANICS

Dual-Band Imaging of Military Targets Using a QWIP Focal Plane Array

Distributed Temperature Sensing

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Health Monitoring System Using FBG-Based Sensors for a 12-Story Building with Column Dampers.

3D-Evaluation Method for Descaling Capability of Hot Strip Mill

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

Photovoltaic Power Generation

Gallium nitride micromechanical resonators for IR detection

Heat Management Methodology

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

UL268 7 th challenge with single infrared smoke detector

Can Short Term ARRA Stimulus Funding Achieve Long Term Market Transformation? 1

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

DEVICE SPECIFICATION FOR PYROELECTRIC IR-DETECTOR

Transcription:

REPORT DOCUMENTATION PAGE Form Approved OMB NO. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggesstions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA, 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any oenalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 13-10-2014 Conference Proceeding 4. TITLE AND SUBTITLE Defect-related dark currents in III-V MWIR nbn detectors 3. DATES COVERED (From - To) - 5a. CONTRACT NUMBER W911NF-11-1-0378 5b. GRANT NUMBER 6. AUTHORS Bjørn F. Andresen, Gabor F. Fulop, Charles M. Hanson, Paul R. Norton, G. R. Savich, D. E. Sidor, X. Du, M. Jain, C. P. Morath, V. M. Cowan, J. K. Kim, J. F. Klem, D. Leonhardt, S. D. Hawkins, T. R. Fortune, A. Tauke-Pedretti, G. W. Wicks 5c. PROGRAM ELEMENT NUMBER 611102 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAMES AND ADDRESSES University of Rochester 518 Hylan Bldg. 8. PERFORMING ORGANIZATION REPORT NUMBER Rochester, NY 14627-0140 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 12. DISTRIBUTION AVAILIBILITY STATEMENT Approved for public release; distribution is unlimited. 10. SPONSOR/MONITOR'S ACRONYM(S) ARO 11. SPONSOR/MONITOR'S REPORT NUMBER(S) 60124-EL.6 13. SUPPLEMENTARY NOTES The views, opinions and/or findings contained in this report are those of the author(s) and should not contrued as an official Department of the Army position, policy or decision, unless so designated by other documentation. 14. ABSTRACT The effect of defects on the dark current characteristics of MWIR, III-V nbn detectors has been studied. Two different types of defects are compared, those produced by lattice mismatch and by proton irradiation. It is shown that the introduction of defects always elevates dark currents; however the effect on dark current is different for nbn detectors and conventional photodiodes. The dark currents of nbn detectors are found to be more tolerant of defects compared to pn-junction based devices. Defects more weakly increase dark currents, and cooling reduces the defect-produced dark currents more rapidly in nbn detectors than in conventional photodiodes. 15. SUBJECT TERMS infrared detectors, MWIR, nbn, photodiode, defects, irradiation, lattice mismatch, dark current. 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF a. REPORT b. ABSTRACT c. THIS PAGE ABSTRACT UU UU UU UU 15. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON Gary Wicks 19b. TELEPHONE NUMBER 585-275-4867 Standard Form 298 (Rev 8/98) Prescribed by ANSI Std. Z39.18

Report Title Defect-related dark currents in III-V MWIR nbn detectors ABSTRACT The effect of defects on the dark current characteristics of MWIR, III-V nbn detectors has been studied. Two different types of defects are compared, those produced by lattice mismatch and by proton irradiation. It is shown that the introduction of defects always elevates dark currents; however the effect on dark current is different for nbn detectors and conventional photodiodes. The dark currents of nbn detectors are found to be more tolerant of defects compared to pn-junction based devices. Defects more weakly increase dark currents, and cooling reduces the defectproduced dark currents more rapidly in nbn detectors than in conventional photodiodes. Conference Name: SPIE Defense + Security Conference Date: May 06, 2014

Defect related dark currents in III-V MWIR nbn detectors G. R. Savich a, D. E. Sidor a, X. Du a, M. Jain a, C. P. Morath b, V. M. Cowan b, J. K. Kim c, J. F. Klem c, D. Leonhardt c, S. D. Hawkins c, T. R. Fortune c, A. Tauke-Pedretti c, G. W. Wicks* a a The Institute of Optics, University of Rochester, 275 Hutchison Rd, Rochester, NY 14627-0186, USA; b Air Force Research Laboratory, Space Vehicles Directorate, 3550 Aberdeen Ave SE, Kirtland AFB, NM, USA 87117; c Sandia National Laboratories, Albuquerque, NM, USA 87185 ABSTRACT The effect of defects on the dark current characteristics of MWIR, III-V nbn detectors has been studied. Two different types of defects are compared, those produced by lattice mismatch and by proton irradiation. It is shown that the introduction of defects always elevates dark currents; however the effect on dark current is different for nbn detectors and conventional photodiodes. The dark currents of nbn detectors are found to be more tolerant of defects compared to pn-junction based devices. Defects more weakly increase dark currents, and cooling reduces the defect-produced dark currents more rapidly in nbn detectors than in conventional photodiodes. Keywords: infrared detectors, MWIR, nbn, photodiode, defects, irradiation, lattice mismatch, dark current. 1. INTRODUCTION 1.1 Barrier Architecture Detectors The recent introduction of barrier architecture detectors has created the potential for improved performance for MWIR detection, particularly in the III-V material family 1. This new class of detector has already shown significant advantages over conventional device architectures, like the pn junction based photodiode, due to their ability to naturally suppress many dark current mechanisms. Barrier architecture detectors have successfully shown suppression of surface leakage currents, depletion layer generation-recombination currents, trap-assisted tunneling, and direct band-to-band tunneling currents 2,3. Furthermore, these devices have shown performance near Rule 07, indicating nearly Auger limited performance comparable to state-of-the-art HgCdTe MWIR detectors 4. 1.2 Defect-Dominated Dark Currents In some applications for MWIR detectors, detectors may become limited by defect-related dark currents. The addition of defect states to the crystal structure of semiconductor-based detectors tends to increase the dark current of these devices. Significantly increasing the defect concentration can cause a measurable reduction in device performance 5. Examples of cases where defect processes may dominate the dark current include grown-in defects such as in superlattice-based detectors; growth on mismatched substrates; and cases where devices will be subjected to the effects of a radiation filled environment. In such cases, using the detector architecture that minimizes the effects of the induced defects is an important consideration. The present work demonstrates that barrier architecture detectors have significant advantages over conventional pn photodiodes in these cases. *wicks@optics.rochester.edu; phone 1 585 275-4867; fax 1 585 244-4936

2. GENERATION RECOMBINATION CURRENTS IN PHOTODETECTORS 2.1 Depletion Region Generation Recombination Current Shockley-Read-Hall (SRH) theory for generation and recombination in pn junction depletion regions describes the effect of defects on dark current density 6,7. The theory predicts that the main effects of temperature and defect concentration are given by: J Depletion Ce E g 2 kt N defect (1) For depletion layer limited generation, SRH theory indicates a thermal activation energy of half the bandgap, and a direct proportionality between dark current density and defect density. 2.2 Neutral Region Generation Recombination Current Shockley s original theory also describes generation processes in neutral regions of semiconductors 6,7. This process has a smaller magnitude effect than depletion region generation, and thus has traditionally been less important, at least in pn junctions. Defect-related generation in neutral regions has different dependences on defect density and temperature than generation in depletion regions. The main effects in the neutral region are given by: J Neutral Ce Eg kt N defect (2) In the neutral region case, the dark current density due to defects maintains a full bandgap thermal activation energy, and is proportional to the square root of the defect density. Although neutral region defects will increase the dark current density, the effect is smaller than that of depletion region defects. 2.3 Generation Recombination Currents in nbn Photodetectors and Conventional Photodiodes In conventional pn junction based photodiodes, generation in both the neutral region and the depletion region may occur; however, depletion region generation is usually dominant, thus defect-related dark currents in pn photodiodes are approximately equal to the dark current generated in the depletion region as indicated in equation 1. nbn detectors, ideally, do not have depletion regions. When nbn detectors are defect-dominated, only neutral region generation currents are possible, therefore, dark current density for defect-dominated nbn s follows equation 2. The differing generation currents that dominate defect-limited pn junction photodiodes and nbn detectors results in two practical effects. Defect related dark currents in nbn detectors show a reduced dependence on the defect density when compared to photodiodes, and cooling is more efficient in reducing nbn s dark current due to the full bandgap activation energy.

3. PERFORMANCE OF InAs PHOTODIODES AND nbn DETECTORS InAs pn junction photodiodes were grown via molecular beam epitaxy (MBE) on both lattice matched and lattice mismatched substrates. Lattice mismatched samples were grown on both InP and GaAs substrates. The InAs buffer thickness on mismatched substrates was varied. Other studies have shown that the defect concentration due to the lattice-mismatch scales inversely with the buffer layer thickness 8. Dark current is plotted against the inverse of the buffer thickness in figure 1. Figure 1. Current density vs. reciprocal buffer thickness for lattice mismatched InAs pn junction photodiodes on GaAs and InP substrates. Reciprocal buffer thickness is directly proportional to the density of defects that are associated with the lattice mismatch. Dark current density is shown to be well fit by a direct proportionality to the defect density. The y-intercept point, indicated at zero reciprocal buffer thickness, or infinite buffer thickness, represent devices on lattice matched, InAs substrates. Since reciprocal buffer thickness is directly proportional to the defect density, fig. 1 shows that the dark current in mismatched pn photodiodes is directly proportional to the defect density, in agreement with equation 1. The lattice mismatch between InAs and GaAs is approximately twice that of the mismatch between InAs and InP, which causes the increased slope and thus elevated dark currents of the InAs photodiodes on GaAs substrates. The y-intercept value indicates the natural dark current present in the InAs detectors due to normal latticematched crystal growth and related dark current mechanisms. The horizontal axis indicates only the defects induced by the lattice mismatch. Superlattice, MWIR nbn detectors were grown and irradiated with 63 MeV protons at low temperatures. The square of the dark current is plotted against proton fluence in figure 2.

Figure 2. Square of the dark current as a function of proton fluence for proton irradiated MWIR nbn photodetectors. The square of the dark current is directly proportional to the proton fluence and the proton fluence is directly proportional to the defect density. The dark current in nbn detectors is proportional to the square root of the defect density. There is a linear relationship between the square of the dark current and the proton fluence. Assuming that the density of irradiation-produced defects is proportional to the fluence, fig.2 indicates that the defect-related dark current in nbn detectors is proportional to the square root of the defect density, in agreement with equation 2. Since defect-related dark currents in conventional pn junction based photodiodes are directly proportional to the defect density, nbn detectors show an increased tolerance to defects by comparison. As in the case of the lattice-mismatched photodiodes, the y- intercept value is indicative of the natural dark current of the devices, present without the introduction of defects due to proton irradiation. The horizontal axis represents only the defects induced via proton irradiation at operating temperatures. The temperature dependences of dark currents of both pn junction and nbn device architectures has also been studied. Figure 3 shows an Arrhenius graph of dark current density of conventional InAs photodiodes, grown both on a lattice matched, InAs substrate, and a lattice mismatched, GaAs substrate. Figure 3. Dark current versus reciprocal temperature for lattice matched and lattice mismatched (GaAs substrate) InAs pn photodiodes. The thermal activation energy of lattice matched InAs photodiodes is equal to the bandgap of InAs (~0.31eV) down to ~210K at which point devices become surface leakage limited. Mismatched photodiodes on GaAs substrates exhibit activation energies slightly less than one half of the bandgap (~0.11eV) indicating behavior dominated by SRH generation in the depletion region.

Lattice matched, conventional InAs photodiodes show full bandgap activation energy, ~0.31 ev, from 300K to about 210K. Below this point, the dark current density becomes temperature independent, indicating the onset of surface leakage limited performance. The lattice mismatched InAs photodiode on a GaAs substrate shows an activation energy of ~0.11 ev, showing elevated dark currents on account of the increase in defects as well as a reduced rate of reduction in dark current density under cooling. Dark current density as a function of temperature has also been studied for InAs nbn detectors on both InAs substrates and lattice mismatched GaAs substrates (figure 4). Figure 4. Dark current versus reciprocal temperature for lattice matched and lattice mismatched (GaAs substrate) InAs nbn detectors. The thermal activation energy (~0.35eV) is equal to the bandgap of InAs over the entire temperature range for both lattice matched and mismatched devices. Mismatched nbn detectors exhibit increased dark current densities compared to lattice matched nbn detectors. The InAs nbn detectors on GaAs substrates show about an order of magnitude more dark current than comparable lattice matched InAs nbn s, indicating that inducing defects increases dark current levels in nbn detectors; however, the lattice mismatched nbn maintains a full bandgap activation energy, ~0.35 ev, equal to that of the lattice matched nbn across the entire measureable temperature range. This is a significant advantage that nbn detectors hold over conventional pn photodiodes. Although defect-limited nbn detectors and conventional photodiodes both show elevated dark currents compared to low defect concentration devices, the nbn maintains its full bandgap activation. This means defect-limited nbn detectors respond better to cooling than comparable pn junction based devices where depletion layer generation currents limit the defect-related activation energy to one half of the bandgap. 4. CONCLUSIONS Defects elevate dark currents in both nbn detectors and conventional pn junction photodiodes; however, in cases where the defects limit dark currents, barrier architecture detectors offer significant benefits over pn photodiodes. nbn detectors are naturally more tolerant to increases in defect concentration, and defect-related dark currents reduce more quickly in nbn detectors under cooling. As a result, nbn detectors may be operated at a higher temperature than pn junction photodiodes in the presence of high defect levels. Defect-limited InAs nbn s show about four orders of magnitude less dark current, compared to conventional photodiodes at an operating temperature of 200K.

REFERENCES [1] Maimon, S. and Wicks, G.W., nbn detector, an infrared detector with reduced dark current and higher operating temperature, Appl. Phys. Lett. 89 (15), 151109 (2006). [2] Pedrazzani, J.R., Maimon, S., and Wicks, G.S., Use of nbn structures to suppress surface leakage currents in unpassivated InAs infrared photodetectors, Electron Lett. 44 (25), 1487 (2008). [3] Savich, G.R., Pedrazzani, J.R., Sidor, D.E., Maimon, S., Wicks, G.W., Dark current filtering in unipolar barrier infrared detectors, Appl. Phys. Lett. 99 (12), 121112 (2011). [4] Tennant, W.E., Lee, D., Zandian, M., Piquette, E., and Carmody, M., MBE HgCdTe Technology: A Very General Solution to IR Detection, Described by Rule 07, a Very Convenient Heuristic, Journal of Electronic Materials 37 (9), 1406 (2008). [5] Cowan, V.M., Morath, C.P., Hubbs, J.E., Myers, S., Plis, E., Krishna, S., Radiation tolerance characterization of dual band InAs/GaSb type-ii strain-layer superlattice pbp detectors using 63 MeV protons, Appl. Phys. Lett. 101 (25), 251108 (2012). [6] Shockley, W., Read, Jr., W.T., Statistics of the recombinations of holes and electrons. Phys. Rev. 87 (5), 835 (1952). [7] Sah, C.-T, Noyce, R.N., Shockley, W., Carrier generation and recombination in p-n junctions and p-n junction characteristics, Proc. IRE 45 (9), 1228 (1957). [8] Krier, A., Suleiman, W., Uncooled photodetectors for the 3-5µm spectral range based on III-V heterojunctions, Appl. Phys. Lett. 89 (8), 083512 (2006).