DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Similar documents
DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT POWER. High energy efficiency Compact and quiet

DYNACIAT ILG. Use. Description. Heat pumps

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

AQUACIAT2 HYBRID. Natural GAS condensation boiler Self-adjusting electronic control. Use. Range. Heat pumps and gas boilers

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

High temperature air-to-water heat pumps

Compact and silent Scroll compressors All-season operation

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

High temperature air-to-water heat pumps

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only.

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Aquaciat Free cooling

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Water chillers water/water type SIGMA Technical information manual

NA G DYNACIAT LG - LGP LG - LGP. DYNACIAT power

kw COOLING kw HEATING

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

TCHE-THHE TCEE

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TCHVZ TCEVZ

30RH B Nominal cooling capacity kw Nominal heating capacity kw

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

30HXC Nominal cooling capacity kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

Air-to-water scroll chillers

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

TCHE-THHE TCEE

Air Cooled Chillers & Heat Pumps WinPACK HE-A

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

44,9 202,0 kw. technicalcatalogue

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

MACH N-407 Heat Pump Air-Cooled Chiller

Neosys Product catalogue

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

SyScroll 40 to 75 Air NEW

MAC N-407 Air-Cooled Chiller

GP SERIES Packaged Chillers

Blue Box Epsilon Echos +

Vertical self-contained air conditioner

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Modular Air-cooled Chillers

Transcription:

High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER LGN series single unit water chillers without condensers are machines designed for air conditioning applications in community and service sector buildings, as well as for industrial premises and processes. These units are designed to be installed as standard in rooms that are protected against freezing temperatures and inclement weather. Range DYNACIAT - DYNACIAT POWER LGN series Cooling-only model without condenser (for split system). Description DYNACIAT - DYNACIAT power LGN series models are supplied as standard with the following components: - chilled-water evaporator - chilled-water outlet power control - control, automatic operation and start-up box:. Electrical supply: Three-phase 50 Hz - 400V (+10%/-10%) + Earth. Control circuit 1~50Hz 230V (+10%/-10%) (transformers fitted on unit as standard) - casing for indoor installation The entire DYNACIAT - DYNACIAT power LGN range conforms to standards and the following European EC directives: - Machinery directive 2006/42/EC - Electromagnetic compatibility directive 2014/30/EU - EMC immunity and emissions EN 61800-3 C3 - Low voltage directive 2014/35/EU - RoHS 2011/65/EU - Pressure equipment directive (PED) 2014/68/EU - Machinery directive EN 60-204 -1 - Refrigerating systems and heat pumps EN 378-2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 1

Main components n Casing - Removable galvanised metal panels - RAL 7024 and RAL 7035 lacquer coating n Hermetic SCROLL compressors - Built-in electric motor cooled by suction gases - Motor protected by internal winding thermostat - Placed on anti-vibration mounts - Integrated crankcase heater n Evaporator - Brazed-plate exchanger(s) - End and inside plates in AISI 316 stainless steel - High-performance, optimised plate patterns - Thermal insulation n Condenser - Unit without condenser - Connection possible on CIAT OPERA-type separate air cooled condenser - Refrigerating sleeves available as an option n Cooling accessories - Dehumidifier filters with rechargeable cartridges - Hygroscopic sight glasses - Solenoid valves on liquid refrigerant lines - Thermostatic expansion valves (700V to 1000V models) - Electronic expansion valves (1100V to 2400V models) - Electronic evaporation pressure controller. n Control functions and safety devices - Thermostatic or electronic expansion valve(s) - Refrigerant high and low-pressure safety devices, - Safety valves on refrigeration circuit - Temperature and pressure sensors - Evaporator water flow controller n Electrics box The fully wired electrics box which houses all the electrical components and the electronic CPU board, controls the entire unit, monitors its operation, adjusts water setpoints and interfaces with an external control system. It comprises: - Control and power circuits - Wire numbering - Main safety switch with handle on front - Control circuit transformer - Circuit breakers on the power and control circuits - Compressor and motor switch(es) - Main earth connection - Microprocessor-controlled electronic control unit CONNECT2 - Alarm or information signals on free terminals n CONNECT2 electronic control module CIAT electronic control module with microprocessor and CPU, with central automatic operation and access to internal operation states. Features: - Start, stop, reset or remote control - Operating mode selector - Outputs RS485 for CMS link (ModBus-JBus) additional potential-free (dry) contact card adapter remote control adapter - Multilingual analogue LCD and LED display Functions: - Operation information displayed via: multilingual clear-text messages direct temperature and pressure readings - complete management of compressors with start-up sequence, timer and runtime balancing Master/slave Management allows two machines to be controlled on a single water loop, by alternating the master and slave according to the running time. - Short-cycle protection - Self-adjusting and proactive functions with adjustment of settings drift control - Series stage system on multiple compressors reduces power according to cooling or heating demands measured from water temperature - Monitoring of internal operation parameters - Second setpoint management - Setpoint adjustment by 4-20 ma signal - Master/slave operation - Weekly programming - Direct readout of water temperatures - Diagnosis of operation and fault states: HP/LP, water flow, compressor motor(s), frost protection - Remote management and remote monitoring n Remote control CONNECT2 is equipped as standard with an RS485 serial port offering a range of remote management, monitoring and diagnostic options via the communication bus. Several contacts are available as standard, enabling the unit to be controlled remotely by cabled link: - automatic operation control: when this contact is open, the machine stops - setpoint 1/setpoint 2 selection: when this contact is closed, a second cold setpoint is activated (energy storage mode, for example) - setpoint adjustable by 4-20 ma signal: this input is used to adjust the setpoint - compressor load shedding: closing the contact or contacts concerned allows the power or cooling consumption of the machine to be limited by stopping one or more compressors - water pump 1 and 2 control: these outputs control the contact switches for one or two water pumps - fault reporting: this contact indicates the presence of a major fault which has caused one or both cooling circuits to stop. n Power control Series stage output control system on the compressors 2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Standard equipment/available options DYNACIAT - DYNACIAT POWER LGN 120V to 600V 700V to 2400V Safety switch l l Control circuit transformer l l Electrical cabinet wire numbers l l RS485 communication interface l l Water flow controller l l Master/slave control of two machines l l Ethernet gateway l l Electronic expansion valve - l 1100-2400 s 700-1000 Low Noise version (compressor casing) - s Xtra Low Noise version (compressor casing with noise insulation) l s Discharge pipe shut-off valve z - Compressor suction shut-off valves - s Low-temperature glycol/ (0 C to -12 C) l s Soft start s s Water filter on evaporator z z Phase controller (reversal, loss, asymmetry, over and under voltage) z z Anti-vibration mounts l z Evaporator flexible hydraulic sleeves z z Flexible sleeve for refrigerant pipe connection z - Refrigerant leak detection z z Remote control unit (remote control console) z z Relay board with dry contacts z z Energy meter - s MULTICONNECT multi-unit management z z LONWORKS / BACNET gateway z z l Supplied as standard s Factory-fitted option z Option supplied in kit - Not available HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 3

Technical characteristics 120V 150V 200V 240V 300V 350V 400V 500V 540V 600V Performance Refrigeration circuit Compressor Net cooling capacity (1) kw 32.2 41.5 55.8 62.6 83.6 94.4 108 135 145.2 165.1 Net power input (2) kw 8.5 11.2 15 17 22.6 26.1 29.8 36.8 39.5 44.7 Net EER kw 3.79 3.72 3.72 3.68 3.69 3.62 3.62 3.67 3.68 3.69 Discharge output 40.7 52.7 70.8 79.7 106.2 120.5 137.8 171.8 184.7 209.8 Lw / Lp (3) db(a) 67 70 69 70 73 74 75 76 75 76 Quantity 1 2 Refrigerant (GWP) R410A (2 088) Refrigerant charge Refrigerant not supplied (nitrogen charge) Type Hermetic SCROLL (2 900 rpm) Quantity 1 2 4 Start-up mode Direct in line in series No. of stages 1 2 3 2 4 Power control Power distribution per circuit C1/C2 Refrigerant oil type % 100-0 100-50-0 100-57- 43-0 100-63- 37-0 100-50-0 100-72-50-22-0 100-75-50-25-0 % 50 / 50 45 / 55 50 / 50 POE 3MAF (32CST) Oil capacity l (cir.1) 3.25 4.14 6.5 6.5 8.28 8.84 9.76 11.24 8.28 8.28 l (cir.2) - - - - - - - 6.5 8.28 Type Brazed-plate heat exchanger Quantity 1 Water content l 2.7 3.6 4.8 5.3 9.9 11.3 12.8 15.7 15.2 19.8 Evaporator High pressure circuit Dimensions Weight Min / max water outlet temperature C -12 C/+18 C Min/max water flow m 3 /h 3.5/11.2 4.8/14.6 6.2/19.8 7.0/22.2 9.5/29.2 10.9/34.0 12.4/38.4 15.2/47.5 16.4/51.1 19.1/58.4 Minimum system water volume l 226 299 197 222 292 286 279 454 217 274 Hydraulic connections Ø G 1''1/2 G 2 G 2''1/2 PN16 DN80 flanges Minimum system diameter Ø DN 50 DN 65 DN 80 Max service pressure bar 10 bar water side Type Without condenser Male gas discharge D Ø (cir1) 7/8" 1"1/8 1"3/8 1"1/8 1"1/8 D Ø (cir2) - - - - - - - - 7/8" 1"1/8 Male liquid return L Ø (cir1) 5/8" 7/8" 1"1/8 7/8" 7/8" L Ø (cir2) - - - - - - - - 7/8" 7/8" Max service pressure bar 40.5 bar Storage temperature C -20 C/+50 C Length mm 798 1492 2380 Width mm 883 Height mm 1201 Weight (empty) kg 216 282 361 364 544 569 610 671 861 1023 Weight in operation kg 224 291 372 375 563 590 647 704 908 1082 (1) Net outputs for chilled water temperature +12 C/+7 C and condensation +45 C (2) Compressors net power input (3) Lw: overall power level as per standard ISO 3744 LP: overall pressure levels measured at 10 m in a free field, calculated using the formula LP=Lw-10 log S Values calculated for a refrigerant connection 7 m in length 4 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Performance Refrigeration circuit Compressor Evaporator Technical characteristics DYNACIAT POWER LGN 700V 800V 900V 1000V 1100V 1200V 1400V 1600V 1800V 2100V 2400V Net cooling capacity (1) kw 203,4 235,3 263,2 293,1 323 354 401 447,9 520,5 590,4 656,9 Net power input (2) kw 53,6 61,7 69,8 78 86,2 94,2 107,3 120,3 142,9 163 183,2 Net EER 3,79 3,81 3,77 3,76 3,75 3,76 3,74 3,72 3,64 3,62 3,59 Discharge output 257 297 333 371,1 409,2 448,2 508,2 568,2 663,4 753,4 840,1 Lw/Lp - Standard (3) db(a) 89/57 90/58 89/57 90/58 91/59 95/63 96/64 93/61 95/63 97/65 Lw/Lp Low Noise (3) db(a) 84/52 85/53 86/54 87/55 88/56 90/58 91/59 89/57 90/58 91/59 Lw/Lp Xtra Low Noise (3) db(a) 79/47 80/48 81/49 82/50 85/53 86/54 85/53 86/54 87/55 Quantity 2 Refrigerant (GWP) R410A (2 088) Refrigerant charge Refrigerant not supplied (nitrogen charge) Type Hermetic SCROLL (2 900 rpm) Quantity 4 6 Start-up mode Power control No. of stages 100-78- % 71-50-28-21-0 Direct in line in series 6 4 6 4 6 4 6 4 6 8 6 100-75- 50-25-0 100-78- 71-50-28-21-0 100-75- 50-25-0 100-78- 71-50-28-21-0 100-75- 50-25-0 100-78- 71-50-28-21-0 100-75- 50-25-0 100-83- 66-50-33-16-0 100-84-66-48-36-30- 18-15-0 100-83- 66-50-33-16-0 Power distribution per circuit C1/C2 % 50 / 50 45 / 55 50 / 50 Refrigerant oil type POE 160SZ POE 3MAF Oil capacity l (cir.1) 13.4 14.4 12.6 18.9 l (cir.2) 13.4 14.4 12.6 18.9 Type Brazed-plate heat exchanger Quantity 1 Water content l 20 23 26 29 32 37 50 57 64 77 77 Min / max water outlet temperature C -12 C / +18 C Min/max water flow m 3 /h 22/70 26/81 29/82 33/105 35/113 38/124 44/137 51/151 61/150 68/150 74/150 Minimum system water volume l 636 880 844 1146 1043 1346 1286 1735 1262 1336 1595 Hydraulic connection Ø VICTAULIC DN 100 VICTAULIC DN 125 VICTAULIC DN 150 Minimum system diameter Ø DN 100 DN 125 DN 150 Max service pressure bar 10 bar water side Type Without condenser High pressure circuit Male gas discharge Male liquid return D Ø (cir1) 1"3/8 1"5/8 2"1/8 D Ø (cir2) 1"3/8 1"5/8 2"1/8 L Ø (cir1) 1"1/8 1"3/8 1"5/8 L Ø (cir2) 1"1/8 1"3/8 1"5/8 Max service pressure bar 40.5 bar Dimensions Weight Storage temperature C -20 C/+50 C Length mm 2099 2499 3350 Width mm 996 Height mm 1869 1887 1970 Weight (empty) kg 920 1019 1036 1148 1180 1223 1389 1462 1993 2071 2106 Weight in operation kg 968 1072 1096 1216 1250 1311 1476 1557 2165 2265 2314 (1) Net outputs for chilled water temperature 12 C/7 C and condensation 45 C (2) Compressors net power input (3) Lw: overall sound power level as per ISO3744 LP: overall pressure levels measured at 10 m in a free field, calculated using the formula LP=Lw-10 log S Values calculated for a refrigerant connection 7 m in length HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 5

Electrical characteristics 120V 150V 200V 240V 300V 350V 400V 500V 540V 600V COMPRESSOR Voltage V 400V - 3Ph - 50Hz (+10%/- 10%) Maximum rated current A 23.2 30.2 42.2 46.2 60.2 66.2 76 91.8 106.2 120.2 Starting current (1) A 137 174 139 160 204 255 302 317.8 250 264 Starting current with Soft Start option (1) A 70 60 76 93 90 167 194 210 136 150 REMOTE CONTROL AUXILIARY CIRCUIT Voltage V 230V - 1Ph - 50Hz (+10%/- 10%) Transformer fitted Maximum rated current A 0.4 0.6 Transformer capacity VA 100 160 Electrics box protection rating IP 22 Machine protection rating IP 22 Breaking capacity ka 50 Max. cable section according to disconnect switch (2) Max. cable section according to rating (3) mm 2 10 35 70 mm 2 10 16 25 35 50 DYNACIAT POWER LGN 700V 800V 900V 1000V 1100V 1200V 1400V 1600V 1800V 2100V 2400V COMPRESSOR Voltage V 400V - 3Ph - 50Hz (+10%/- 10%) Maximum rated current A 140 160 182 205 218 232 266 295 356 399 443 Starting current (1) A 316 334 391 414 480 494 586 615 607 720 763 Starting current with Soft Start option (1) A 230 248 287 310 352 366 429 453 483 562 605 REMOTE CONTROL AUXILIARY CIRCUIT Voltage V 230V - 1Ph - 50Hz (+10%/- 10%) Maximum rated current A 0.8 1.3 Transformer capacity VA 160 250 Electrics box protection rating IP 21 Machine protection rating IP 21 Breaking capacity ka 40.5 61.5 70 Max. cable section according to disconnect switch (2) Max. cable section according to rating (3) mm 2 240 300 mm 2 95 120 185 240 2 x 185 (1) Starting current of largest compressor + maximum current of other compressors under full load (2) Max. cable section permitted by the disconnect switch in terms of cable diameter and connection terminals (3) Min. cable diameter required, determined from maximum rated currents. 6 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Condenser cooling and heating discharge outputs DYNACIAT - DYNACIAT POWER LGN R410A LGN 120V 150V 200V 240V 300V 350V 400V Evaporator water outlet temperature ( C) Cc: Gross cooling capacity Pi: Compressors gross absorbed power. Hc: Gross heating capacity CONDENSATION TEMPERATURE ( C) 35 40 45 50 55 Cc Pi Hc Cc Pi Hc Cc Pi Hc Cc Pi Hc Cc Pi Hc kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw -12 16.5 6.6 22.8 15.1 7.4 22.2 13.6 8.3 21.5 11.8 9.4 20.5-8 19.5 6.6 25.8 18.2 7.4 25.3 16.7 8.3 24.6 14.9 9.4 23.8-4 23.1 6.7 29.4 21.7 7.4 28.8 20.0 8.3 28.0 18.2 9.4 27.1 16.2 10.6 26.2 0 27.3 6.7 33.7 25.8 7.4 32.9 24.1 8.3 32.0 22.2 9.4 31.1 20.1 10.6 30.1 2 29.4 6.7 35.8 27.8 7.4 35.0 26.0 8.3 34.0 24.1 9.4 33.0 21.8 10.6 31.9 5 34.0 6.7 40.4 32.2 7.4 39.4 30.2 8.3 38.2 28.0 9.4 37.0 25.6 10.6 35.7 7 36.4 6.8 42.9 34.6 7.5 41.7 32.4 8.3 40.5 30.1 9.3 39.1 27.6 10.6 37.8 10 40.6 6.8 47.2 38.6 7.5 45.8 36.4 8.3 44.4 33.9 9.3 42.9 31.2 10.5 41.3 12 43.4 6.8 50.0 41.3 7.5 48.6 38.9 8.3 46.9 36.3 9.3 45.3 33.4 10.5 43.6 15 47.8 6.9 54.5 45.5 7.5 52.8 42.9 8.3 51.0 40.1 9.3 49.2 37.1 10.5 47.2 18 52.7 6.9 59.4 50.2 7.6 57.6 47.2 8.4 55.4 44.3 9.3 53.4 41.0 10.5 51.1-12 21.7 8.6 29.9 20.3 9.6 29.3 18.9 10.6 28.9 17.1 11.9 28.4-8 25.8 8.6 34.1 24.3 9.6 33.5 22.7 10.7 32.9 21.0 11.9 32.3-4 30.3 8.7 38.8 28.7 9.7 38.1 26.9 10.7 37.2 25.0 11.9 36.4 22.8 13.4 35.5 0 34.9 8.8 43.4 33.3 9.7 42.7 31.4 10.8 41.9 29.4 12.0 40.9 27.2 13.4 40.0 2 37.6 8.8 46.0 35.8 9.7 45.2 33.9 10.8 44.3 31.7 12.0 43.3 29.4 13.4 42.2 5 43.1 8.9 51.6 41.2 9.8 50.6 39.0 10.9 49.5 36.6 12.0 48.2 33.9 13.5 46.9 7 46.1 8.9 54.7 44.1 9.9 53.6 41.8 10.9 52.3 39.3 12.1 51.0 36.5 13.5 49.5 10 51.5 9.0 60.2 49.3 9.9 58.8 46.7 10.9 57.3 43.9 12.1 55.7 40.9 13.5 54.0 12 54.9 9.0 63.7 52.6 9.9 62.3 49.9 11.0 60.5 47.0 12.1 58.8 43.8 13.5 56.9 15 60.5 9.1 69.6 58.0 10.0 67.7 55.0 11.0 65.7 51.9 12.2 63.7 48.5 13.6 61.6 18 66.4 9.2 75.7 63.6 10.1 73.6 60.5 11.1 71.3 57.1 12.3 69.0 53.4 13.6 66.6-12 27.4 11.7 39.1 25.2 13.2 38.4 23.0 14.9 38.0-8 33.2 11.7 44.9 30.8 13.2 44.0 28.5 14.9 43.4 26.0 16.9 42.9-4 39.5 11.7 51.2 37.0 13.2 50.2 34.4 14.9 49.2 31.4 16.8 48.2 28.4 19.0 47.4 0 47.1 11.6 58.7 44.3 13.1 57.4 41.3 14.8 56.1 38.3 16.7 55.0 34.7 18.9 53.6 2 50.7 11.6 62.3 47.7 13.1 60.8 44.8 14.7 59.5 41.3 16.7 58.0 37.8 18.8 56.6 5 58.4 11.7 70.0 55.4 13.1 68.5 52.1 14.7 66.8 48.3 16.6 64.8 44.3 18.7 63.0 7 62.5 11.7 74.2 59.6 13.1 72.6 56.1 14.7 70.8 52.0 16.5 68.5 47.9 18.6 66.6 10 70.0 11.8 81.7 65.3 13.1 78.5 62.6 14.7 77.3 58.0 16.5 74.5 54.1 18.6 72.7 12 74.8 11.9 86.7 71.0 13.2 84.2 67.3 14.7 82.0 63.0 16.5 79.5 58.6 18.5 77.1 15 82.1 12.0 94.1 78.5 13.3 91.8 74.3 14.8 89.0 69.8 16.5 86.3 63.5 18.5 82.0 18 90.2 12.2 102.3 86.3 13.4 99.7 81.8 14.9 96.6 77.1 16.5 93.6 71.5 18.5 90.0-12 30.9 13.2 44.1 28.6 14.8 43.4 25.7 16.6 42.3-8 37.4 13.2 50.7 34.9 14.9 49.8 32.1 16.7 48.8 28.7 18.8 47.5-4 44.5 13.3 57.7 41.8 14.9 56.6 38.8 16.7 55.5 35.3 18.8 54.1 31.4 21.3 52.7 0 70.5 13.4 83.8 66.3 14.9 81.2 61.3 16.7 78.0 58.3 18.8 77.1 53.4 21.2 74.5 2 57.1 13.3 70.4 54.0 14.8 68.8 50.6 16.7 67.2 46.7 18.8 65.5 42.3 21.2 63.5 5 65.6 13.3 78.9 62.2 14.9 77.1 58.4 16.7 75.1 54.1 18.8 72.9 49.5 21.2 70.7 7 70.5 13.4 83.8 66.3 14.9 81.2 63.0 16.7 79.7 58.3 18.8 77.1 53.4 21.2 74.5 10 78.8 13.5 92.2 74.8 14.9 89.8 70.4 16.7 87.1 65.5 18.7 84.2 60.5 21.1 81.6 12 83.9 13.5 97.5 80.1 15.0 95.1 74.9 16.7 91.6 70.2 18.7 88.9 65.0 21.1 86.1 15 92.8 13.7 106.5 87.7 15.1 102.7 83.2 16.7 99.9 77.4 18.7 96.1 71.8 21.1 92.9 18 102.0 13.9 115.9 97.3 15.2 112.5 92.0 16.8 108.8 85.9 18.8 104.7 79.7 21.1 100.8-12 42.3 17.1 59.4 39.8 19.4 58.7 36.9 21.5 58.2 33.5 24.0 57.5-8 50.5 17.2 67.7 47.7 19.5 66.8 44.5 21.6 65.9 41.1 24.1 65.0-4 59.5 17.3 76.8 56.4 19.7 75.8 52.8 21.8 74.4 49.0 24.3 73.0 44.8 26.7 71.7 0 70.2 17.5 87.6 66.7 19.9 86.5 62.7 22.0 84.6 58.6 24.4 82.8 53.7 26.9 80.7 2 75.8 17.5 93.3 72.0 20.0 91.9 67.4 22.1 89.3 63.4 24.5 87.7 58.1 27.0 85.1 5 87.1 17.6 104.7 82.8 20.1 103.0 78.1 22.3 100.3 73.0 24.7 97.6 67.5 27.2 94.6 7 93.4 17.7 111.1 88.9 20.2 109.1 83.9 22.3 106.2 78.5 24.8 103.1 72.6 27.3 99.9 10 104.3 17.8 122.1 99.4 20.3 119.7 93.9 22.5 116.5 88.0 24.9 112.9 81.6 27.5 109.1 12 111.5 17.9 129.4 106.2 20.4 126.6 100.5 22.6 123.1 94.2 25.1 119.2 87.5 27.6 115.1 15 123.1 18.0 141.1 117.2 20.6 137.5 111.0 22.8 133.7 104.1 25.2 129.3 96.8 27.8 124.6 18 135.5 18.0 153.5 129.1 20.8 149.3 122.3 23.0 145.0 114.9 25.3 140.2 106.9 28.0 134.9-12 46.5 20.0 66.5 43.6 22.1 65.7 40.7 24.7 65.4-8 55.8 20.2 76.0 53.0 22.3 75.4 49.4 24.8 74.2 45.8 27.8 73.6-4 66.5 20.5 86.9 62.8 22.5 85.4 59.2 25.0 84.2 54.8 27.9 82.7 50.4 31.3 81.7 0 79.0 20.7 99.7 74.8 22.8 97.7 70.4 25.2 95.7 65.7 28.1 93.7 60.6 31.3 91.9 2 85.8 20.9 106.7 81.0 23.0 104.0 76.2 25.4 101.6 71.7 28.2 99.9 65.9 31.4 97.3 5 98.7 21.1 119.8 93.4 23.2 116.7 88.2 25.6 113.8 82.3 28.4 110.6 76.2 31.6 107.8 7 105.6 21.2 126.8 100.7 23.4 124.1 94.8 25.8 120.5 88.3 28.5 116.8 82.0 31.7 113.7 10 119.0 21.3 140.4 113.1 23.6 136.6 106.4 26.0 132.4 99.8 28.8 128.6 92.5 31.9 124.4 12 127.3 21.4 148.7 121.1 23.7 144.8 114.3 26.2 140.4 106.9 28.9 135.8 99.5 32.1 131.5 15 140.8 21.5 162.3 133.8 23.8 157.6 126.4 26.4 152.7 118.5 29.1 147.7 110.3 32.3 142.6 18 155.1 21.5 176.6 147.4 24.0 171.3 139.6 26.5 166.1 131.0 29.4 160.3 121.8 32.5 154.4-12 53.7 22.9 76.6 50.7 25.4 76.1 47.4 28.3 75.8-8 64.4 23.2 87.6 60.8 25.7 86.4 57.1 28.5 85.6 53.1 31.8 85.0-4 76.2 23.5 99.7 72.2 25.9 98.1 68.0 28.7 96.7 63.2 32.0 95.2 58.2 35.7 93.9 0 90.6 23.8 114.3 85.6 26.2 111.9 80.8 29.0 109.8 75.5 32.2 107.7 69.4 35.8 105.2 2 97.5 23.9 121.4 92.7 26.4 119.1 87.1 29.1 116.2 81.3 32.3 113.6 75.3 35.9 111.2 5 112.8 24.1 136.9 106.7 26.6 133.3 100.8 29.4 130.1 94.3 32.5 126.9 87.5 36.1 123.6 7 121.0 24.2 145.1 115.0 26.7 141.7 108.3 29.5 137.8 101.5 32.7 134.1 93.9 36.2 130.1 10 135.3 24.3 159.6 128.7 26.9 155.6 121.5 29.7 151.3 115.1 32.9 148.0 106.0 36.4 142.3 12 144.9 24.4 169.3 138.0 27.0 165.0 130.3 29.8 160.1 122.1 33.0 155.1 113.3 36.5 149.8 15 160.3 24.4 184.7 152.2 27.1 179.3 144.1 30.0 174.1 135.1 33.2 168.3 125.7 36.7 162.4 18 176.8 24.4 201.2 168.2 27.2 195.4 159.1 30.1 189.2 149.6 33.3 182.9 139.0 36.9 175.9 Standard conditions required. Calculated fouling 0.00005 m 2 C/W HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 7

Condenser cooling and heating discharge outputs DYNACIAT - DYNACIAT power LGN R410A LGN 500V 540V 600V 700V 800V 900V 1000V Evaporator water outlet temperature ( C) CONDENSATION TEMPERATURE ( C) 35 40 45 50 55 Cc Pi Hc Cc Pi Hc Cc Pi Hc Cc Pi Hc Cc Pi Hc kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw -12 68.7 28.5 97.2 65.1 31.6 96.7 60.8 35.1 95.9 55.4 39.1 94.4-8 81.6 28.8 110.3 77.1 31.8 109.0 72.2 35.4 107.6 67.1 39.3 106.4-4 95.6 29.0 124.6 90.6 32.1 122.7 85.0 35.6 120.6 79.1 39.6 118.6 72.8 44.0 116.8 0 115.3 29.3 144.6 109.2 32.4 141.6 102.7 35.9 138.6 95.9 39.8 135.7 88.6 44.3 132.9 2 123.8 29.5 153.3 117.5 32.5 150.0 110.6 36.0 146.5 103.2 39.9 143.1 95.5 44.4 139.8 5 141.4 29.8 171.2 134.1 32.8 166.9 127.4 36.2 163.6 118.9 40.1 159.1 110.1 44.6 154.7 7 152.3 29.9 182.2 144.0 32.9 176.9 135.5 36.3 171.8 127.4 40.2 167.6 117.3 44.7 161.9 10 169.4 30.2 199.6 160.9 33.1 194.0 151.8 36.5 188.3 142.3 40.4 182.7 132.1 44.8 176.9 12 180.7 30.3 211.1 171.6 33.3 204.9 162.1 36.6 198.7 152.0 40.5 192.5 141.4 44.9 186.2 15 198.0 30.6 228.6 188.4 33.5 221.9 178.2 36.9 215.0 167.2 40.7 207.9 155.6 45.0 200.7 18 217.7 30.9 248.7 207.0 33.8 240.7 195.9 37.1 233.0 183.9 40.9 224.8 171.3 45.2 216.5-12 70.5 30.3 100.8 66.2 33.8 100.0 59.1 37.9 97.0-8 87.6 30.5 118.1 82.3 34.0 116.3 76.1 38.0 114.1 69.3 42.7 112.0-4 103.2 30.6 133.8 97.6 34.3 131.9 90.9 38.2 129.1 83.4 42.8 126.2 75.8 48.1 123.9 0 122.5 30.8 153.3 116.0 34.6 150.5 108.7 38.5 147.2 100.8 42.9 143.8 92.0 48.1 140.1 2 132.0 30.9 162.9 125.2 34.7 159.8 117.5 38.6 156.1 109.1 43.0 152.1 99.9 48.2 148.1 5 151.9 31.0 182.8 144.2 34.9 179.1 135.7 38.8 174.5 126.5 43.2 169.7 116.3 48.3 164.6 7 162.9 31.1 194.0 154.8 35.0 189.9 145.8 38.9 184.7 135.9 43.4 179.3 125.3 48.4 173.7 10 181.8 31.2 213.0 172.8 35.3 208.0 162.8 39.2 202.0 152.3 43.5 195.9 140.8 48.5 189.3 12 194.8 31.4 226.1 185.2 35.3 220.5 174.9 39.3 214.2 163.5 43.7 207.2 151.3 48.7 200.0 15 214.8 31.5 246.2 204.6 35.4 240.0 193.3 39.4 232.7 181.0 43.9 224.9 167.8 48.9 216.6 18 236.4 31.6 268.0 225.3 35.5 260.8 212.9 39.6 252.4 199.7 44.1 243.8 185.4 49.1 234.4-12 85.1 34.3 119.3 78.8 38.8 117.6 72.8 42.4 115.3-8 99.7 34.3 134.0 94.1 38.9 133.1 88.0 42.7 130.6 81.1 47.9 129.0-4 117.5 34.4 151.9 111.3 39.1 150.4 104.3 43.0 147.3 96.9 48.1 145.0 88.5 53.6 142.0 0 132.4 34.5 166.8 126.6 39.2 165.8 122.7 43.4 166.1 112.0 48.5 160.5 106.6 53.9 160.4 2 148.5 34.5 183.0 140.2 39.4 179.5 131.0 43.6 174.6 121.2 48.7 170.0 112.1 54.0 166.0 5 171.9 34.6 206.5 163.6 39.5 203.1 154.3 44.0 198.3 144.2 49.3 193.4 133.2 54.4 187.6 7 184.4 34.7 219.1 175.4 39.7 215.1 165.6 44.2 209.8 154.9 49.5 204.4 143.3 54.6 197.9 10 205.8 34.8 240.6 196.2 39.9 236.1 185.4 44.6 230.0 173.6 49.9 223.5 160.9 55.0 215.9 12 220.2 34.9 255.1 209.9 40.0 249.9 198.3 44.8 243.1 186.0 50.1 236.1 172.6 55.3 227.9 15 242.9 35.0 277.9 231.4 40.2 271.5 219.0 45.1 264.1 205.5 50.4 255.9 191.1 55.7 246.8 18 267.6 35.1 302.7 255.1 40.4 295.4 241.4 45.5 286.8 226.8 50.6 277.5 210.9 56.1 267.0-12 99.1 43.2 140.2 93.6 48.2 139.3 87.0 53.9 137.7 79.8 60.3 136.1-8 119.1 43.1 160.4 113.5 48.0 159.4 105.3 53.7 156.2 96.7 60.0 153.3 88.0 67.2 150.9-4 140.3 42.9 181.6 132.5 47.9 178.4 123.8 53.5 174.9 114.5 59.8 171.3 104.8 66.9 167.9 0 170.9 42.8 212.3 161.9 47.7 207.8 151.7 53.2 202.8 141.0 59.5 197.8 131.1 66.6 194.4 2 184.4 42.8 225.9 175.2 47.7 221.2 164.2 53.2 215.3 154.2 59.4 211.1 141.5 66.5 204.9 5 212.0 42.8 253.6 201.5 47.6 247.7 190.1 53.0 241.3 178.1 59.2 235.0 165.2 66.2 228.6 7 227.2 42.9 268.9 215.9 47.6 262.1 203.9 53.0 255.2 191.2 59.2 248.2 177.6 66.1 241.1 10 253.7 43.0 295.7 241.9 47.7 288.3 228.6 53.0 280.0 214.5 59.1 271.6 199.5 66.0 263.1 12 271.5 43.1 313.6 258.3 47.7 304.8 244.3 53.0 295.9 229.6 59.1 286.8 213.8 66.0 277.5 15 298.6 43.3 341.0 284.5 47.9 331.3 269.4 53.1 321.1 253.3 59.1 310.7 236.3 65.9 300.1 18 327.8 43.6 370.6 312.2 48.1 359.3 296.8 53.3 348.7 278.9 59.2 336.5 260.5 66.0 324.4-12 117.2 48.9 163.9 109.9 53.5 161.7 102.1 60.6 159.6 94.3 67.5 158.1-8 138.9 48.9 185.8 130.8 53.6 183.0 122.2 60.6 180.2 112.6 67.6 177.1 102.6 76.1 174.3-4 163.2 48.9 210.3 154.3 53.7 206.8 144.3 60.7 202.7 133.7 67.6 198.7 123.9 76.1 196.4 0 198.3 48.8 245.6 188.0 53.9 240.6 176.2 60.8 234.9 163.7 67.7 229.1 150.7 76.1 223.6 2 213.3 48.8 260.6 202.1 54.0 254.8 190.8 60.8 249.5 177.1 67.8 242.6 164.9 76.1 238.0 5 245.2 48.9 292.8 232.8 54.1 285.7 220.3 60.9 279.1 205.7 67.9 271.3 190.9 76.1 264.2 7 263.0 49.0 310.7 249.3 54.2 302.3 235.5 61.0 294.5 220.7 67.9 286.4 204.9 76.1 278.2 10 293.3 49.2 341.4 278.9 54.5 332.1 263.7 61.1 322.8 247.0 68.0 313.4 230.5 76.1 303.9 12 312.9 49.4 361.2 297.8 54.7 351.2 281.7 61.2 340.9 264.6 68.1 330.5 246.6 76.1 320.1 15 343.8 49.9 392.7 327.6 55.1 381.4 310.9 61.2 370.5 292.0 68.1 358.0 272.3 76.1 345.9 18 377.5 50.4 427.0 359.9 55.5 414.2 341.7 61.4 401.6 321.2 68.2 387.5 300.0 76.1 373.8-12 132.2 54.6 184.2 124.8 60.7 182.3 116.3 67.4 180.0 107.3 75.0 177.7-8 156.5 54.9 209.2 147.7 61.0 205.9 138.0 67.8 202.4 127.9 75.4 199.2 117.1 84.1 196.1-4 183.9 55.2 237.0 174.0 61.2 232.7 163.2 68.1 228.1 151.1 75.7 223.1 138.8 84.4 218.5 0 223.0 55.5 276.8 211.3 61.6 270.7 198.8 68.4 264.4 184.8 76.1 257.5 170.1 84.8 250.8 2 239.6 55.7 293.6 227.1 61.7 286.7 214.3 68.5 280.3 200.2 76.2 273.2 186.0 84.9 267.0 5 275.0 56.1 329.6 262.1 62.1 322.2 247.0 68.8 313.4 231.1 76.5 304.6 214.1 85.1 295.7 7 294.9 56.4 349.8 280.1 62.3 340.6 264.3 69.0 331.1 247.8 76.6 321.7 230.3 85.2 312.1 10 328.4 56.9 383.9 312.4 62.7 373.5 295.7 69.4 363.0 277.5 76.9 351.9 258.0 85.5 340.3 12 350.4 57.3 406.4 333.3 63.0 394.7 315.9 69.6 383.6 296.4 77.1 371.1 276.0 85.7 358.6 15 385.2 57.9 441.9 366.4 63.6 428.5 348.0 70.1 416.2 327.0 77.5 402.3 304.4 86.0 387.5 18 422.1 58.7 479.7 401.8 64.3 464.6 382.3 70.7 451.3 358.8 78.0 434.7 335.1 86.4 418.8-12 144.7 60.2 202.1 139.9 66.7 203.2 130.5 73.9 200.3 120.8 82.0 197.8-8 174.3 60.9 232.7 165.2 67.2 229.4 155.2 74.4 225.9 145.4 82.5 223.4 132.8 91.7 219.0-4 204.4 61.5 263.6 193.7 67.8 258.7 184.0 75.0 255.7 170.2 83.0 249.2 155.3 92.2 242.4 0 247.5 62.3 307.8 236.4 68.6 302.6 221.2 75.7 293.9 205.6 83.7 285.7 190.9 92.8 279.3 2 266.5 62.6 327.2 252.9 68.9 319.4 237.9 76.0 311.0 223.7 84.1 304.3 206.5 93.1 295.4 5 306.4 63.4 368.0 293.0 69.7 360.5 276.5 76.8 350.6 259.1 84.7 340.6 237.8 93.7 327.6 7 329.2 63.9 391.4 312.9 70.1 381.0 293.8 77.1 368.4 276.0 85.1 358.1 257.4 94.1 347.7 10 367.6 64.7 430.7 350.0 70.9 419.0 331.2 77.9 406.7 310.3 85.8 393.2 288.2 94.8 379.5 12 392.6 65.2 456.4 373.9 71.4 443.5 353.4 78.4 429.5 331.2 86.3 414.7 308.1 95.2 399.9 15 430.9 66.1 495.7 410.2 72.3 480.7 389.0 79.2 466.2 365.0 87.1 449.5 339.6 96.0 432.3 18 472.7 67.1 538.6 450.3 73.2 522.0 426.0 80.1 504.1 401.4 88.0 486.9 373.7 96.8 467.5 Cc: Gross cooling capacity Pi: Compressors gross power input. Hc: Gross heating output to be discharged Standard conditions required. Calculated fouling 0.00005 m 2 C/W 8 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Condenser cooling and heating discharge outputs DYNACIAT - DYNACIAT power LGN R410A LGN 1100V 1200V 1400V 1600V 1800V 2100V 2400V Evaporator water outlet temperature ( C) CONDENSATION TEMPERATURE ( C) 35 40 45 50 55 Cc Pi Hc Cc Pi Hc Cc Pi Hc Cc Pi Hc Cc Pi Hc kw kw kw kw kw kw kw kw kw kw kw kw kw kw kw -12 165.9 67.6 230.4 156.0 74.8 227.0 143.7 82.9 221.9 132.6 92.1 219.0-8 192.2 67.9 257.3 181.5 75.1 253.1 169.9 83.1 248.9 157.4 92.3 244.6 144.1 102.7 240.5-4 224.9 68.4 290.7 213.3 75.5 285.7 199.9 83.5 279.6 185.5 92.5 273.4 170.5 102.8 267.7 0 272.4 69.0 339.2 258.8 76.1 332.2 242.9 84.0 323.5 226.2 93.0 315.1 208.1 103.2 306.3 2 293.1 69.3 360.3 278.7 76.4 352.5 261.9 84.3 343.0 244.3 93.2 333.6 225.0 103.4 323.6 5 337.3 69.8 405.2 320.6 76.9 395.2 302.5 84.9 384.5 283.8 93.8 374.1 261.2 103.9 360.7 7 360.9 70.2 429.2 342.7 77.2 417.7 324.1 85.2 406.5 303.3 94.1 393.9 281.1 104.2 381.1 10 401.7 70.7 470.7 383.4 77.8 459.1 361.9 85.7 445.0 340.1 94.6 431.5 315.2 104.6 415.9 12 429.1 71.0 498.5 408.1 78.2 484.2 387.1 86.1 470.7 362.4 94.9 454.3 337.5 105.0 438.8 15 471.6 71.6 541.7 448.7 78.7 525.5 425.3 86.6 509.6 399.5 95.5 492.1 372.0 105.5 474.0 18 516.6 72.2 587.4 492.1 79.3 569.7 466.9 87.2 552.0 438.7 96.1 532.2 409.1 106.1 511.9-12 174.1 74.8 244.7 163.7 82.6 241.2 152.5 91.6 237.5 141.8 101.9 235.1-8 210.0 75.0 281.8 198.5 82.9 277.6 185.4 91.9 272.7 171.3 102.0 267.7-4 246.1 75.3 318.6 233.2 83.2 313.0 219.3 92.0 307.1 203.4 102.0 300.3 185.8 113.5 293.1 0 298.1 75.7 371.3 283.0 83.6 363.6 268.8 92.4 357.5 249.7 102.3 347.6 229.2 113.6 337.3 2 322.1 75.9 395.7 304.6 83.8 385.5 286.4 92.6 375.4 266.5 102.5 364.7 245.2 113.7 353.6 5 369.9 76.3 444.1 352.2 84.3 433.8 331.7 93.0 421.5 310.7 102.9 409.7 286.7 114.0 395.9 7 398.1 76.5 472.6 379.1 84.5 461.2 355.2 93.2 445.4 332.7 103.1 432.1 307.2 114.2 416.8 10 445.6 76.8 520.6 423.7 84.8 506.3 400.4 93.7 491.2 375.4 103.5 475.4 347.8 114.6 458.2 12 475.2 77.0 550.5 451.9 85.1 534.8 428.2 93.9 519.4 400.6 103.7 501.0 371.6 114.8 482.4 15 522.2 77.2 597.9 497.9 85.3 581.3 470.7 94.2 562.5 441.8 104.1 542.8 410.1 115.2 521.5 18 572.6 77.4 648.5 546.0 85.6 629.8 517.0 94.5 609.3 485.6 104.4 587.1 452.1 115.5 564.0-12 201.1 81.8 283.0 190.0 91.1 281.1 178.0 101.5 279.6-8 237.8 82.6 320.4 226.7 91.8 318.5 212.1 102.1 314.2 196.6 113.7 310.3-4 278.9 83.6 362.5 267.2 92.6 359.9 251.9 102.8 354.8 233.9 114.3 348.2 215.6 127.3 342.9 0 338.7 85.1 423.8 322.4 93.9 416.3 303.7 103.9 407.6 283.5 115.3 398.8 260.3 128.1 388.4 2 364.5 85.8 450.3 347.5 94.5 442.0 324.6 104.4 429.0 303.1 115.7 418.8 283.4 128.5 411.9 5 417.7 87.3 505.0 398.2 95.9 494.1 374.9 105.6 480.5 351.2 116.8 468.0 325.5 129.5 454.9 7 447.1 88.2 535.3 426.1 96.6 522.7 401.6 106.3 507.9 376.6 117.4 494.0 349.3 130.0 479.3 10 499.5 89.8 589.3 474.5 98.1 572.6 449.6 107.6 557.3 421.5 118.6 540.1 391.7 131.1 522.8 12 532.1 90.8 623.0 506.0 99.0 605.0 479.1 108.5 587.6 450.5 119.4 569.9 418.8 131.9 550.7 15 584.7 92.6 677.3 556.3 100.6 656.9 528.0 110.0 638.0 495.8 120.8 616.5 462.1 133.1 595.2 18 640.8 94.5 735.4 610.4 102.4 712.8 579.2 111.6 690.9 545.0 122.3 667.2 508.7 134.6 643.2-12 228.4 90.4 318.8 216.8 99.9 316.6 203.9 110.8 314.7-8 269.9 91.5 361.4 255.1 101.3 356.4 240.7 112.3 353.0 223.8 124.6 348.3-4 314.7 93.0 407.6 298.6 102.7 401.3 282.7 113.8 396.5 265.2 126.2 391.3 243.7 139.9 383.6 0 379.9 95.1 475.0 360.7 104.8 465.4 339.6 115.7 455.3 320.2 128.1 448.3 292.2 141.7 433.9 2 407.7 96.1 503.8 387.7 105.7 493.4 366.3 116.5 482.8 341.8 128.8 470.6 315.7 142.5 458.2 5 467.2 98.2 565.4 445.7 107.6 553.3 419.7 118.3 537.9 394.2 130.4 524.7 365.0 144.1 509.1 7 499.0 99.4 598.4 476.5 108.7 585.2 448.8 119.2 568.0 422.3 131.4 553.6 391.1 144.9 536.1 10 556.3 101.7 658.0 529.2 110.7 639.8 502.5 121.1 623.6 470.8 133.0 603.8 439.4 146.5 585.9 12 592.1 103.2 695.3 565.2 112.1 677.2 534.6 122.3 656.9 503.6 134.1 637.7 468.2 147.5 615.7 15 649.1 105.7 754.8 620.0 114.0 734.0 587.5 124.3 711.8 554.6 135.9 690.5 516.0 149.1 665.2 18 710.5 108.5 819.0 685.0 116.0 801.0 646.7 127.0 773.7 607.8 138.0 745.8 568.3 151.0 719.3-12 258.1 112.0 370.1 244.9 123.7 368.6 229.5 136.6 366.1-8 308.5 112.3 420.8 291.9 124.3 416.2 273.8 137.4 411.3 254.9 154.0 408.9-4 363.5 112.9 476.4 344.5 125.0 469.5 323.4 138.3 461.7 301.6 154.8 456.4 278.6 171.9 450.5 0 442.5 114.2 556.7 419.7 126.3 546.0 394.5 139.5 534.0 368.1 155.6 523.7 340.1 173.1 513.1 2 475.3 114.8 590.1 451.5 126.7 578.2 426.8 140.1 566.9 397.4 156.1 553.6 367.6 173.5 541.1 5 544.1 116.1 660.3 515.7 127.4 643.2 487.2 140.9 628.1 455.2 156.8 612.0 423.1 174.1 597.2 7 582.1 116.9 699.0 552.2 128.0 680.2 522.0 141.4 663.4 489.1 157.3 646.5 454.1 174.6 628.6 10 648.7 118.3 767.0 615.9 129.8 745.7 582.0 143.1 725.1 546.2 158.4 704.6 507.9 176.0 683.9 12 692.1 119.2 811.3 657.9 130.7 788.6 621.8 143.9 765.7 583.4 159.2 742.6 542.2 176.7 718.9 15 760.6 120.6 881.3 723.7 132.1 855.8 685.1 145.3 830.4 644.2 160.5 804.7 597.5 177.9 775.4 18 834.0 122.2 956.2 794.5 133.6 928.1 752.4 146.8 899.3 708.0 162.0 870.1 659.7 179.5 839.2-12 302.4 124.5 426.9 287.6 138.6 426.2 268.8 154.5 423.3 244.4 172.1 416.4-8 357.9 125.8 483.7 338.5 139.6 478.2 321.3 155.4 476.7 297.6 173.0 470.6-4 419.5 127.2 546.8 402.4 141.0 543.4 373.6 156.4 530.0 347.7 173.8 521.5 320.5 193.5 514.0 0 501.3 129.3 630.6 476.8 142.7 619.5 447.7 157.9 605.6 418.7 175.2 593.9 387.8 194.8 582.5 2 541.2 130.3 671.5 511.5 143.6 655.1 484.2 158.7 642.9 450.7 175.9 626.5 416.9 195.3 612.3 5 615.4 132.5 747.9 585.1 145.5 730.6 551.4 160.4 711.8 516.0 177.4 693.3 478.3 196.7 675.0 7 660.7 133.8 794.5 626.0 146.6 772.6 591.6 161.4 753.0 555.6 178.4 733.9 514.0 197.6 711.6 10 734.1 136.1 870.2 699.4 148.8 848.2 660.8 163.3 824.2 620.6 180.1 800.7 577.6 199.2 776.8 12 783.4 137.7 921.1 744.9 150.2 895.1 706.2 164.7 870.9 663.3 181.3 844.6 616.9 200.3 817.2 15 859.8 140.2 1000.0 819.1 152.6 971.6 776.4 166.9 943.3 729.7 183.3 913.0 680.3 202.2 882.5 18 944.6 143.2 1087.8 895.3 155.1 1050.4 851.7 169.3 1021.0 801.7 185.6 987.2 748.3 204.3 952.6-12 345.0 137.1 482.0 325.8 152.0 477.8 304.8 168.5 473.3 277.8 187.1 465.0-8 405.5 139.2 544.7 383.6 154.2 537.7 361.8 170.9 532.7 335.3 189.5 524.8 302.4 210.3 512.7-4 473.4 141.5 614.9 448.7 156.4 605.1 426.1 173.3 599.4 395.2 191.9 587.1 361.4 212.7 574.1 0 562.7 144.6 707.3 534.1 159.3 693.3 505.4 175.9 681.3 475.2 194.7 670.0 438.7 215.6 654.3 2 601.5 146.0 747.5 572.2 160.5 732.7 541.2 177.1 718.3 507.5 195.8 703.2 471.7 216.8 688.5 5 683.8 149.0 832.8 652.1 163.3 815.4 616.6 179.6 796.2 578.0 198.1 776.1 537.4 219.0 756.4 7 731.6 150.8 882.4 695.6 164.9 860.5 659.0 181.1 840.1 618.7 199.5 818.1 575.7 220.3 795.9 10 811.9 154.1 966.0 773.3 167.8 941.1 732.8 183.7 916.5 688.3 201.9 890.1 640.9 222.5 863.3 12 865.3 156.3 1021.6 824.0 169.8 993.8 781.3 185.5 966.8 735.0 203.5 938.5 685.7 224.0 909.7 15 949.9 160.0 1110.0 904.9 173.1 1078.1 858.8 188.5 1047.3 809.6 206.2 1015.8 755.7 226.5 982.1 18 1037.5 163.1 1200.6 991.6 176.1 1167.7 942.2 191.9 1134.1 888.6 209.3 1097.9 831.7 229.3 1061.0 Cc: Gross cooling capacity Pi: Compressors gross power input. Hc: Gross heating output to be discharged Standard conditions required. Calculated fouling 0.00005 m 2 C/W HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 9

Sound levels Split system The distinguishing feature of the range is its rigorous design incorporating the latest "noiseless" assembly techniques guaranteeing a reduction in vibrations and sound pollution: n Scroll compressor(s) fitted on anti-vibration mounts. n Refrigerating circuit fitted on anti-vibration mounts on a structure which is insulated from the frame (120 to 600). n Pipes uncoupled from unit structure. n Sound power level ref 2 x 10-12 Pa ±3 db (Lw) DYNACIAT SOUND POWER LEVEL SPECTRUM (db) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Overall level Lw db(a) 120V 77 65 65 59 59 61 59 67 150V 78 74 72 67 60 64 57 70 200V 78 60 60 62 62 64 62 69 240V 78 68 68 62 62 64 62 70 300V 81 77 75 70 63 67 60 73 350V 82 75 75 68 64 69 63 74 400V 83 76 76 69 67 70 64 75 500V 84 74 77 67 69 72 66 76 540V 83 78 76 70 66 69 64 75 600V 84 80 78 73 66 70 63 76 n Sound pressure level ref 2 x 10-5 Pa ± 3 db (Lp) Measurement conditions: n free field n 10 metres from machine, 1.50 metres above floor level n directivity 2 DYNACIAT SOUND PRESSURE SPECTRUM (db) 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Overall level LP db(a) 120V 46 34 34 28 28 29 28 35 150V 47 43 41 35 29 33 25 39 200V 47 28 29 31 31 33 30 38 240V 47 37 37 31 31 32 31 38 300V 50 46 44 38 32 36 28 42 350V 51 43 43 37 33 38 31 42 400V 52 44 45 37 36 39 32 44 500V 53 43 45 36 38 40 34 45 540V 51 46 44 39 34 37 33 43 600V 52 48 47 41 35 39 31 45 N.B.: Sound pressure levels depend on the installation conditions of each system. As such, the levels listed above are given for information only. We remind you that only sound power levels are comparable and certified. 10 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Sound levels STANDARD version (without noise insulation on compressors) n Sound power level ref 2 x 10-12 Pa ±3 db (Lw) DYNACIATpower SPECTRE DE NIVEAU DE PUISSANCE (db) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Niveau puissance global db(a) 700V 75 78 84 80 84 80 89 800V 77 78 83 81 87 81 90 900V 76 77 86 82 85 80 90 1000V 75 75 88 83 82 78 89 1100V 77 82 89 85 82 78 90 1200V 78 84 90 87 81 77 91 1400V 82 90 85 90 91 85 95 1600V 82 90 85 91 92 87 96 1800V 90 89 91 88 86 83 93 2100V 90 90 90 91 89 84 95 2400V 90 90 90 92 91 85 97 n Sound pressure level ref 2 x 10-5 Pa ±3 db (Lp) Measurement conditions: free field, 10 metres from machine, 1.50 metres above floor level, directivity 2. DYNACIATpower SPECTRE DE NIVEAU DE PUISSANCE (db) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Niveau puissance global db(a) 700V 43 46 52 48 52 48 57 800V 45 46 51 49 55 49 58 900V 44 45 54 50 53 48 58 1000V 43 43 56 51 50 46 57 1100V 45 50 57 53 50 46 58 1200V 46 52 58 55 49 45 59 1400V 50 58 53 58 59 53 63 1600V 50 58 53 59 60 53 64 1800V 58 57 59 56 54 51 61 2100V 58 58 58 59 57 52 63 2400V 58 58 58 60 59 53 65 N.B.: Sound pressure levels depend on the installation conditions of each system. As such, the levels listed here are given for information only. Only the sound power levels are comparable and certified. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 11

Sound levels LOW NOISE version (compressor casing) n Sound power level ref 2 x 10-12 Pa ±3 db (Lw) DYNACIATpower SPECTRE DE NIVEAU DE PUISSANCE (db) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz n Sound pressure level ref 2 x 10-5 Pa ±3 db (Lp) Measurement conditions: free field, 10 metres from machine, 1.50 metres above floor level, directivity 2. Niveau puissance global db(a) 700V 80 78 83 76 77 74 84 800V 82 78 82 76 79 76 85 900V 81 77 85 77 78 74 85 1000V 80 75 87 78 75 73 86 1100V 82 82 88 81 74 72 87 1200V 83 84 89 82 74 71 88 1400V 87 90 84 85 83 80 90 1600V 87 90 84 87 85 81 91 1800V 89 87 87 81 80 79 89 2100V 89 88 87 84 82 80 90 2400V 89 88 87 86 84 80 91 DYNACIATpower SPECTRE DE NIVEAU DE PUISSANCE (db) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Niveau puissance global db(a) 700V 48 46 51 44 45 42 52 800V 50 46 50 44 47 44 53 900V 49 45 53 45 46 42 53 1000V 48 43 55 46 43 41 54 1100V 50 50 56 49 42 40 55 1200V 51 52 57 50 42 39 56 1400V 55 58 52 53 51 48 58 1600V 55 58 52 55 53 49 59 1800V 57 55 55 49 48 47 57 2100V 57 56 55 52 50 48 58 2400V 57 56 55 54 52 48 59 N.B.: Sound pressure levels depend on the installation conditions of each system. As such, the levels listed here are given for information only. Only the sound power levels are comparable and certified. 12 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Sound levels XTRA LOW NOISE version (compressor casing with noise insulation) n Sound power level ref 2 x 10-12 Pa ±3 db (Lw) DYNACIATpower SPECTRE DE NIVEAU DE PUISSANCE (db) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Niveau puissance global db(a) 700V 78 75 76 67 73 72 79 800V 79 75 75 68 75 73 80 900V 79 74 78 69 74 72 80 1000V 78 73 80 70 71 70 80 1100V 79 79 81 72 70 70 81 1200V 80 81 82 74 70 69 82 1400V 84 87 77 77 79 77 85 1600V 84 88 77 78 81 79 86 1800V 87 84 84 76 75 75 85 2100V 88 84 83 79 78 76 86 2400V 89 84 83 81 79 77 87 n Sound pressure level ref 2 x 10-5 Pa ±3 db (Lp) Measurement conditions: free field, 10 metres from machine, 1.50 metres above floor level, directivity 2. DYNACIATpower SPECTRE DE NIVEAU DE PUISSANCE (db) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz Niveau puissance global db(a) 700V 46 43 44 65 41 40 47 800V 47 43 43 36 43 41 48 900V 47 42 46 37 42 40 48 1000V 46 41 48 38 39 38 48 1100V 47 47 49 40 38 38 49 1200V 48 49 50 42 38 37 50 1400V 52 55 45 45 47 45 53 1600V 52 56 45 46 49 47 54 1800V 55 52 52 44 43 43 53 2100V 56 52 51 47 46 44 54 2400V 57 52 51 49 47 45 55 N.B.: Sound pressure levels depend on the installation conditions of each system. As such, the levels listed here are given for information only. Only the sound power levels are comparable and certified. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 13

Operating range LGN 120 to 2400 Condensation temperature ( C) Glycol compulsory Evaporator limits -12-8 -4 Evaporator water outlet temperature ( C) The curves opposite represent the minimum and maximum temperature differences permissible for chilled water or glycol/water mix according to the outlet temperature. Example: For one water outlet: + 5 C Minimum difference: 2.6 C Water temperature: 7.6/5 C Maximum difference: 6 C Water temperature: 11/5 C If the temperature difference calculated is outside the two curves, contact us. T admissible water inlet/outlet temperature difference ( C) Brazed plate evaporator Maximum T Minimum T coefficients Water outlet temperature ( C) Calculation T for performance tables n 30% concentration by weight of glycol. n Solution freezing point: -17.5 C. K: correction factors. Values read in instructions: Cc: cooling capacity based on selection tables. Pi: compressor power input based on selection tables. DP: Water pressure drop based on the curves, for the corresponding corrected flow rate (Qc). Corrected values based on calculations opposite: Ccc: Corrected cooling capacity. Qc: Corrected chilled water flow. DHc: Corrected water pressure drop (evaporator or condenser. Evaporator CORRECTION Cooling capacity Chilled water flow rate Water pressure drop Avg. temp. gradient POSITIVE TEMP. NEGATIVE TEMP. K Calculation method K Calculation method 0,98 Ccc = Cc x 0.98 1,00 See selection table Ccc x 0.86 Ccc x 0.86 1,05 Qc = x 1.05 1,10 Qc = x 1.10 DT DT 1,15 DHc = DC x 1.15 1,30 DHc = DC x 1.30 12/7 C See operating limits 14 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Correction coefficients for ethylene glycol n Evaporator Condenser Volume percent concentration of ethylene glycol n Glycol concentration required Multiplier correction factor Cooling capacity Water flow rate Pressure drops 10 0,99 1,05 1,05 20 0,985 1,10 1,10 30 0,98 1,15 1,15 40 0,97 1,20 1,23 Volume concentration in % 0 10 20 30 40 Ethylene glycol Propylene glycol Freezing point C 0-4 -10-18 -27 Minimum water outlet C 5 +3-1 -7-14 Freezing point C 0-4 -9-16 -25 Minimum water outlet C 5 +4 +1-4 -9 Minimum water volume The Connect controller uses anticipation logic making it particularly flexible in adjusting operation by authorising changes to settings, particularly on hydraulic systems with low water volumes. By adjusting compressor running times, it prevents short-cycle protection cycles from starting and, in most cases, eliminates the need for a buffer tank by improving the reliability of the machine. The calculation of the minimum water volume is given for EUROVENT rated conditions, in cooling mode only. N.B.: Calculations of minimum volumes of chilled water are made for the following conditions: - chilled water temperature to evaporator: 12 C/7 C - condensation temperature: 45 C This value is applicable for most air conditioning applications (unit with fan coil units) Comment: For installations running with a low volume of water (assembly with air handling unit) or for industrial processes, the buffer tank is a required component. 120V 150V 200V 240V 300V 350V 400V 500V 540V 600V Min. system capacity (litres) 226 299 197 222 292 286 279 454 217 274 DYNACIAT POWER LGN 700V 800V 900V 1000V 1100V 1200V 1400V 1600V 1800V 2100V 2400V Min. system capacity (litres) 636 880 844 1146 1043 1346 1286 1735 1262 1336 1595 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 15

Water pressure drop LGN 120-600 Shell and tube evaporator water pressure drop 16 Water pressure drop (mwc) 10 8 6 5 4 3 2 120V 150V 200V 240V 300V 400V 350V 500V 600V 540V 1 0.8 3 4 5 6 7 8 9 10 15 20 30 40 50 60 70 80 Water flow rate m 3 /h Do not extrapolate the curves. Always stay within minimum and maximum flow rate values. Evaporator water pressure drop filter 8 6 4 2 120V - 150V 300V - 350V 400V - 500V Water pressure drop (mwc) 1 0.8 0.6 0.4 0.2 200V - 240V 540V - 600V 0.1 3 4 5 6 7 8 9 10 15 20 30 40 50 60 70 80 Water flow rate m 3 /h 16 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Hydraulic specifications LGN 700-2400 n Shell and tube evaporator water pressure drop DYNACIAT POWER LGN Water pressure drop (mwc) 12.1 10 9 8 7 6 5 4 3 2 700V 800V 900V 1000V 1400V 1100V 1200V 1600V 2100V - 2400V 1800V 0.9 1 0.8 0.7 20 25 30 40 50 60 70 80 90 100 150 Water flow rate m 3 /h Do not extrapolate the curves. Always stay within minimum and maximum flow rate values. n Evaporator water pressure drop filter 7.3 6 5 4 3 Water pressure drop (mwc) 2 1 0.8 0.6 0.5 0.4 0.3 0.2 700V to 900V 1000V to 1600V 1800V to 2400V 0.1 20 25 30 40 50 60 70 80 90 100 150 Water flow rate m 3 /h HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 17

Dimensions 120V - 500V Fig.1 Fig.2 788 1483 175 150 150 150 L D 2 1 325 276 280 280 L D 2 1 A 873 1201 150 E 150 E 150 1201 798 1493 883 60 763 763 60 60 136 526 136 60 286 921 286 LGN 120 150 200 240 300 350 400 500 Figure 1 2 A 127 120 D 7/8 1 1/8 1 3/8 D L Discharge pipe(s) connection Fluid return pipe(s) connection Chilled water inlet Chilled water outlet Electrical supply L 5/8 7/8 1 1/8 G 1 1/2 G 2 G 2 1/2 E Ø 40 Ø 60 Weight (kg) empty 216 282 361 364 544 569 610 671 in operation 224 291 372 375 563 590 647 704 18 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Dimensions 540V - 600V 210 275 275 275 380 680 L D L' D' 2370 E 2 1 150 80 1201 98 110 873 2380 883 60 763 60 286 1808 286 Circuit 1 Circuit 2 Weight (kg) LGN 540 600 D 1 1/8 L 7/8 D 7/8 1 1/8 L 7/8 PN16 DN80 flanges E Ø 60 Ø 60 empty 861 1023 In operation 908 1082 D D L L E Discharge pipe(s) connection Fluid return pipe(s) connection Chilled water inlet Chilled water outlet Electrical supply HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 19

Dimensions Split system n DYNACIAT POWER LGN 700V to 1200V 340±10 49±10 996 3 4 5 6 1221 183 152 148 P P 137 1 2 1207 568 Door opening Ouverture de la porte 1000 P 1869 125 585 585 Wooden blocks X 4 Cales bois X4 125 2099 1104 4 6 3 5 129 433 E 2 Electrical connection on the side Noise insulation panels option Discharge pipe(s) connection - Fluid return pipe(s) connection Chilled water inlet Chilled water outlet 217 1 LGN 700 800 900 1000 1100 1200 Circuit 1 5 1 3/8 1 5/8 6 1 1/8 1 3/8 Circuit 2 Weight (kg) 3 1 3/8 1 5/8 4 1 1/8 1 3/8 DN 100 VICTAULIC DN 125 VICTAULIC empty 920 1019 1036 1148 1180 1223 in operation 968 1072 1096 1216 1250 1311 20 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Dimensions n DYNACIAT POWER LGN 1400V to 1600V 3 4 5 6 184 151 149 340±10 63±10 1 2 532 Door opening Ouverture de la porte 996 1221 P P 765 763 2499 1240 600 Wooden blocks X 4 Cales bois X4 P 1104 125 1887 4 6 3 5 131 451 E Electrical connection on the side Noise insulation panels option Discharge pipe(s) connection - Fluid return pipe(s) connection 2 Chilled water inlet Chilled water outlet 217 1 LGN 1400 1600 Circuit 1 5 1 5/8 6 1 3/8 Circuit 2 Weight (kg) 3 1 5/8 4 1 3/8 DN 125 VICTAULIC empty 1389 1462 in operation 1476 1557 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 21

Dimensions n DYNACIAT Power LGN 1800V to 2400V 996 A E 161±10 Door opening Ouverture de la porte 1240.5 532 1 2 1104 663±4 663±4 P P P 1221 185 151 148 3 4 5 6 1969 170 P 800 125 1135 3349 1135 Wooden blocks Cales bois X X44 1084 1 220 2 140 422 3 5 4 6 E Circuit 1 Circuit 2 LGN 1800 2100 2400 5 2 1/8 6 1 5/8 3 2 1/8 4 1 5/8 DN 150 VICTAULIC Electrical connection on the side Noise insulation panels option Discharge pipe(s) connection - Fluid return pipe(s) connection Chilled water inlet Chilled water outlet Weight (kg) empty 1993 2071 2106 in operation 2165 2265 2314 22 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

Schematic installation diagram LGN series n Installation with CIAT OPERA-type separate air-cooled condenser L A J E G H C I K K F B D DYNACIAT Power LGN L A E I C G H I K D B F K J J A : Chilled water circuit B : Control valve C : Water top-up D : Expansion vessel E : Hydraulic safety valve F : G : H : I : J : Drain Shut-off valve Water filter (Compulsory) Flexible connections Refrigerant safety valve K : Temperature measuring well L : Communication BUS connection (RS485) between drycooler controller and chiller N.B.: the system schematic diagrams are provided for information purposes only; under no circumstances do they constitute a model for installation. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 23

Installation recommendations n Water quality criteria to be respected N.B.: It is essential that an 800 micron water filter be placed on the unit's water inlet during installation. The quality of the water used has a direct impact on the correct and compliant operation of the water chiller and its service life. This is particularly true if the water used clogs or corrodes components or promotes the growth of algae or micro-organisms. The water must be tested to determine whether it is suitable for the unit and whether chemical treatment will suffice to make it of acceptable quality and if a water softening/demineralising system should be installed. The results of the analysis must confirm whether the site's water is compatible with the various materials used on the CIAT unit's circuit: - 99.9% copper tubes brazed with copper and silver, - threaded bronze couplings or flat steel flanges, depending on the unit model, - plate heat exchangers and AISI 316/DIN 1.4401 stainless steel connections brazed with copper and silver. N.B.: The guarantee shall be void if these instructions are not followed. n Lifting and handling The utmost safety precautions must be taken when lifting and handling the unit. Always follow the lifting diagram affixed to the unit and the installation, operation, commissioning and maintenance manual. Before attempting to lift the unit, make sure the path leading to its intended location is free from obstacles. Always keep the unit vertical when moving it. Never tip it or lie it on its side. n Choosing a location for the unit DYNACIAT POWER units are designed for installation in a machine room. Precautions should be taken to protect it from freezing temperatures. Special attention should be paid to ensure sufficient free space (including at the top) to allow maintenance. The unit must be placed on a perfectly level, fireproof surface strong enough to support it once charged. Noise pollution from auxiliary equipment such as pumps should be studied thoroughly. Depending on the room and its structure, potential noise transmission routes should be studied, with assistance from an acoustical engineer if necessary, before installing the unit. Flexible couplings MUST be placed over pipes (available as options). n Machine room ventilation According to the regulations in force in the place in which the machine is to be installed, the machine room must comply with certain ventilation rules for fresh air to ensure there is no risk of discomfort or hazard in the event of a refrigerant leak. n Assembly of separately supplied accessories: A number of optional accessories may be delivered separately and installed on the unit on site. Always follow the instructions in the user manual (Installation, Operation, Commissioning and Maintenance). n Electrical connections: Always follow the instructions in the user manual (Installation, Operation, Commissioning and Maintenance). All information concerning electrical connections is stated on the wiring diagrams provided with the unit. Always follow this information to the letter. Electrical connections must be made in accordance with best current practices and applicable standards and regulations. Electrical connections to be made on site: unit's electrical supply, outdoor operation authorisation (optional) information feedback (option). It should be noted that the unit's electrical system is not protected against lightning strikes. Therefore components to protect against transient voltage surges must be installed on the system and inside the electrical supply unit. 24 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

n Pipe connections: Always follow the instructions in the user manual (Installation, Operation, Commissioning and Maintenance) All pipes must be correctly aligned and slope toward the system's drain valve. Pipes must be installed to allow sufficient access to the panels and fitted with heat insulation. Pipe mountings and clamps must be separate to avoid vibrations and placing pressure on the unit. Water shut-off and control valves must be fitted when the unit is installed. - Pipe connections to be made on site:. system water supply with pressure-reducing valve,. evaporator and discharge, - Accessories essential to any hydraulic system must also be installed, such as: - a thermostatically-controlled valve for controlling the flow rate of cooling water placed at the condenser water inlet or outlet.. water expansion vessel,. drain nozzles at pipe low points,. exchanger shut-off valves equipped with filters,. air vents at pipe high points, - check the system's water capacity (install a buffer water tank if necessary),. flexible couplings on exchanger inlets and outlets,. thermometers on each water inlet and outlet to allow all the necessary checks during start-up and maintenance. N.B.: - Pressure in the water circuits below 4.0 bar. - Place the expansion vessel before the pump. - Do not place any valves on the expansion vessel. - Make sure the water circulation pumps are placed directly at the exchanger inlets. - Make sure the pressure of the water drawn in by the circulation pumps is greater than or equal to the required minimum NPSH, particularly if the water circuits are "open". - Test the water quality in accordance with the relevant technical requirements. - Take the necessary precautions to protect the unit and hydraulic system from freezing temperatures (e.g. allow for the possibility of draining the unit). If glycol is added to prevent freezing, check its type and concentration beforehand. - Before making any final hydraulic connections, flush the pipes with clean water to remove any debris in the network. n Refrigerant connections Performance levels are provided for a refrigerant connection between the LGN unit and the OPERA (7 m long). The maximum recommended length is 30 m, with a maximum height difference of 15 m. - Always follow the instructions in the user manual (Installation, Operation, Commissioning and Maintenance). - The pipes are made from refrigeration quality copper and in accordance with accepted engineering practice. - CIAT does not offer this equipment which is designed to be connected to a non-brand condenser or refrigerant connections, nor can CIAT provide system start-up services in this case. - The pipes must be carefully routed taking into account the constraints of the oil return to the compressor and pressure drops which could affect performance levels. n Commissioning Dynaciat machines must be commissioned by CIAT or a CIAT-approved firm. Always follow the instructions in the user manual (Installation, Operation, Commissioning and Maintenance). Partial list of precommissioning checks: - Correct positioning of unit, - Power supply protections, - Phases and direction of rotation, - Wiring connections on unit, - Direction of water flow in unit, - Cleanliness of water circuit, - Adjusting water flow rate to specified value, - Pressure in the refrigeration circuit, - Direction of rotation of compressors, - Water pressure drops and flow rates, - Operating readings. n Maintenance operations Specific preventive maintenance operations must be carried out regularly on the unit by CIAT-approved firms. The operating parameters are read and noted on a "CHECK LIST" form to be returned to CIAT. To do this, always refer to and follow the instructions in the user manual (Installation, Operation, Commissioning and Maintenance). You must take out a maintenance contract with a CIAT-approved refrigeration equipment specialist. Such a contract is required even during the warranty period. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 25

Air-cooled condensers n Available in a wide range of sizes and 6 fan speeds, OPERA adapts to the dimensional or acoustic constraints of each site. 26 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B

USER-FRIENDLY INTERFACE CONSOLE - LCD display (4 lines of 24 characters each) - Pressure and temperature readings - Diagnosis of operation and fault states - Master/slave control of two machines in parallel - Fault memory management - Pump management - Time schedules - Remote control PRODUCT FUNCTIONALITY MULTICONNECT MULTI-UNIT MANAGEMENT (option) Main functions available: - Management of up to 8 units on a single water loop - Management in COOLING mode (water chiller) or HEATING mode (heat pump) - Management of chilled-water or hot-water pumps - Centralised management of a backup unit - Machine load shedding - System time programming - Energy storage mode management - Unit running time balancing Via dry contact POTENTIAL-FREE (DRY) CONTACTS AVAILABLE AS STANDARD Inlets: - Automatic operation control - Selection of setpoints 1 / 2 - Setpoint adjustable by 4-20 ma signal - Heating/cooling mode selection - Compressor load shedding Outlets: - General fault reporting - Pump control COMMUNICATION Customer CMS Additional outlets available as options: - Water flow fault - Frost protection fault - Pump fault - Fan fault (air-to-water machine) - Low and high pressure fault - Compressor safety fault - Discharge temperature fault - Compressor operating status Via BUS communication OUTLET AS STANDARD - Open ModBus-JBUS RS 485 protocol (standard) - ModBus-ETHERNET TC/IP protocol (standard) - LONWORKS protocol (option) - BACNET protocol (option) CIAT SYSTEM FUNCTIONALITY Communication with Hysys system (generator, transmitter, air handling unit), controlled by an Easy CIATcontrol or Smart CIATcontrol touch tablet. Logging of consumption data and temperatures Optimal Water : optimisation of producer performance based on building requirements Optimal Stop and Start: optimisation of the building restart time Communication with CIAT Energy Pool controlled by Power Control. Integrated Power Control: Energy optimisation of refrigeration and heating using several generators, Manages free cooling capacity Uses heat recovery to supply domestic hot water. Smart CIATControl Power Control HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.705 B 27