INSTALLATION MANUAL ENGLISH FRANÇAIS AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-30, 32SK Series. Outdoor unit RAS-30, 32S Series

Similar documents
R32 INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-10PKVPG-E RAS-13PKVPG-E RAS-16PKVPG-E

INSTALLATION MANUAL ENGLISH AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-05, 07, 10, 13, 16BKV-E. Outdoor unit RAS-05, 07, 10, 13, 16BAV-E

38VYX025-R, 38VYX035-R

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

RAV-SM566KRT-E RAV-SM806KRT-E

INVERTER SPLIT - TYPE

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Choosing the installation site. Installation. 07 Choosing the installation site

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

AIR CONDITIONER (MULTI-SPLIT TYPE)

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

ROOM AIR CONDITIONER INSTALLATION MANUAL

INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) ENGLISH ESPAÑOL FRANÇAIS. Indoor unit RAS-09, 12EK Series. Outdoor unit RAS-09, 12EA Series

Installation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1 RAS-4M27UAV-E RAS-3M26UAV-E. For OUTDOOR USE only.

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Installation Manual. Indoor Unit MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL

1. BEFORE INSTALLATION

[FLARE CONNECTION TYPE] ATTENTION

1. BEFORE INSTALLATION

SPLIT-TYPE ROOM AIR CONDITIONER

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

1. BEFORE INSTALLATION

38VYX110/38VYX130 I S O INSTALLATION MANUAL

AS09HPAN AS12HPAN. Split-type Air Conditioner (Cooling and Heating)

1. BEFORE INSTALLATION

Split-type Air-Conditioner

1. BEFORE INSTALLATION

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

Split-type Air-Conditioner

1. BEFORE INSTALLATION

Installation manual for room air conditioner

1. BEFORE INSTALLATION

1. BEFORE INSTALLATION

Saunier Duval Clima, S.A.

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-07SKSX-1 / RAS-07S2AX-1 RAS-09SKSX-1 / RAS-09SASX-1

Air Conditioner. user installation & manual manual. imagine the possibilities

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit. English. Model name: For commercial use

Saunier Duval Clima, S.A.

R410A SPLIT SERIES DC INVERTER

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

FLOOR TYPE AIR CONDITIONERS

RAV-SM2246AT8-E RAV-SM2246AT8J-E RAV-SM2806AT8-E RAV-SM2806AT8J-E

INSTALLATION MANUAL Duct Type Series MH FECA

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION R410A INSTALLATION MANUAL

RAV-SM1104AT8P-E RAV-SM1104AT8JP-E RAV-SM1404AT8P-E RAV-SM1404AT8JP-E

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Split-type Air-Conditioner

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

DAIKIN AIR CONDITIONER

Installation Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SP180CT-UL RAV-SP240CT-UL RAV-SP300CT-UL RAV-SP360CT-UL RAV-SP420CT-UL.

Installation Manual. Indoor Unit

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation manual. Branch kit 1:3 RBC-TRP100E AIR CONDITIONER (SPLIT TYPE) Model name: Installation manual. Air conditioner (Split type) 1 English

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

INSTALLATION INSTRUCTIONS

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO )

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

Installation Manual MMU-AP0154SH-E MMU-AP0184SH-E MMU-AP0244SH-E AIR CONDITIONER (MULTI TYPE) Indoor Unit. Model name: 1-Way Cassette Type.

INSTALLATION INSTRUCTIONS

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

INSTALLATION MANUAL. AIR CONDITIONER INDOOR UNIT (Wall Mounted Type) PART No Contents 1. SAFETY PRECAUTIONS. En-1

INSTALLATION MANUAL. R22 Split Series. Models FTY25GXV1 FTY35GXV1. Installation manual R22 Split series

Installation Instructions

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

AIR CONDITIONER (SPLIT TYPE) Installation manual. Outdoor Unit RAV-SM1603AT-E1 RAV-SM1603ATJ-E1. Model name: English. For commercial use

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

INSTALLATION INSTRUCTIONS CS-KS30NKU + CU-KS30NKUA CS-KS36NKU + CU-KS36NKUA

SPLIT -TYPE ROOM AIR CONDITIONER

AIR CONDITIONER INSTALLATION MANUAL MANUEL D INSTALLATION MANUAL DE INSTALACIÓN. INDOOR UNIT (Floor Type) UNITÉ INTÉRIEURE (type sol)

Safety Precautions WARNING INSTALLING THE UNIT POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

INSTALLATION MANUAL. AIR CONDITIONER INDOOR UNIT (Wall Mounted Type) PART No Contents 1. SAFETY PRECAUTIONS. En-1

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

MULTI TYPE ROOM AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Installation Manual. Indoor Unit

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

42PHW / 42PHQ 42PHQ...K

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Mini-Split Air Conditioner

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

AIR CONDITIONER (MULTI TYPE) Installation Manual. Indoor Unit. Model name:

Installation Instructions

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

INVENTER SPLIT -TYPE ROOM AIR CONDITIONER

INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION

High Wall Split Air Conditioners 53QHCT KHCT

AIR TO WATER HEAT PUMP. Installation Manual. Outdoor Unit. Model name: HWS-P804HR-E HWS-P1104HR-E. English

INSTALLATION INSTRUCTIONS

AIR CONDITIONER (SPLIT TYPE) Installation Manual. Indoor Unit. Installation Manual 1 English. Kurulum kılavuzu 26 Türkçe.

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Transcription:

INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) ENGLISH FRANÇAIS Indoor unit RAS-30, 32SK Series Outdoor unit RAS-30, 32S Series 1110651147 Toshiba 1110651147 (COVER_F)

EN CONTENTS FR SOMMAIRE PRES FOR SAFETY... 1 INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS... 2 Optional Installation Parts... 2 INDOOR UNIT... 3 Installation Place... 3 Cutting a Hole and Mounting Installation Plate... 3 Wiring Connection... 4 Piping and Drain Hose Installation... 4 Indoor Unit Fixing... 5 Drainage... 5 OUTDOOR UNIT... 5 Installation Place... 5 Refrigerant Piping Connection... 6 Evacuating... 6 Wiring Connection... 6 Electrical Work... 7 Refrigerant Piping... 7 OTHERS... 8 Gas Leak Test... 8 Remote Control A-B Selection... 8 Test Operation... 8 Auto Restart Setting... 8 MESURES DE SÉCURITÉ... 1 PLAN D INSTALLATION DES UNITÉS INTÉRIEURE ET EXTÉRIEURE... 2 Pièces d Installation en Option... 2 UNITÉ INTÉRIEURE... 3 Endroit d Installation... 3 Ouverture du Trou et Montage de la Plaque d Installation.. 3 Connexion des Câbles... 4 Installation de la Conduite et du Tuyau de Purge... 4 Installation de l Unité Intérieure... 5 Drainage... 5 UNITÉ EXTÉRIEURE... 5 Endroit d Installation... 5 Connexion du Tuyau Réfrigérant... 6 Evacuation... 6 Connexion des Câbles... 6 Travaux Electriques... 7 Tuyau Réfrigérant... 7 AUTRES... 8 Test de Fuite Gaz... 8 Sélection de Télécommande A-B... 8 Opération du Test... 8 Réglage de la Remise en Marche Automatique... 8 Toshiba 1110651147 (TOC)

PRES FOR SAFETY Before installation, please read these precautions for safety carefully. Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below. WARNING : It indicates that incorrect use of this unit may cause severe injury or death. : It indicate that incorrect use of this unit may cause personal injury (*1), or property damage (*2). *1 : Personal injury means a slight accident, burn, or electrical shock which does not require admission or repeated hospital treatment. *2 : Property damage means greater damage which affects assets or resources. For general public use Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed fl exible cord (design H07RN-F) or cord designation 60245 IEC66, 4.0 mm 2 or more and 1.5 mm 2 or more for connecting cable. (Shall be installed in accordance with national regulations.) To disconnect the appliance from the main power supply This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm in all poles. If this is not possible, a power supply plug with earth must be used. This plug must be easily accessible after installation. The plug must be disconnected from the power supply socket in order to disconnect the appliance completely from the mains. DANGER FOR USE BY QUALIFIED PERSONS ONLY. TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF. FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK. CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE DAMAGED. CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION. DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS. FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION. TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC. WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT (R22) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS. IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS. WARNING Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches. Do not install in a place which cannot bear the weight of the unit. Personal injury and property damage can result if the unit falls. Before doing the electrical work, attach an approved plug to the power supply cord. Also, make sure the equipment is properly earthed. Appliance shall be installed in accordance with national wiring regulations. If you detect any damage, do not install the unit. Contact your TOSHIBA dealer immediately. Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water. After unpacking the unit, examine it carefully for possible damage. Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and discharged air might disturb neighbors. To avoid personal injury, be careful when handling parts with sharp edges. Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation. REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures. EN ES FR IT PL CZ RU CR HU TR NL GR SV FI NO DK RO BG EE LV SK SI 1

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS 170 mm or more 50 mm or more 1 Installation plate For the rear left and left piping Wall 170 mm or more Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better operation. Air fi lter Do not allow the drain hose to get slack. Shield pipe Cut the piping hole sloped slightly. 5 Filter (Attach to the front panel.) 3 Batteries 6 Filter Make sure to run the drain hose sloped downward. 8 Pan head wood screw 4 Remote control holder The auxiliary piping can be connected to the left, rear left, rear right, right, bottom right or bottom left. 2 Wireless remote control Vinyl tape Apply after carrying out a drainage test. Right Rear right Remark : Detail of accessory and installation parts can see in the accessory sheet. Some pictures might be different from the actual parts. 500 mm or more Saddle 200 mm or more Extension drain hose (Not available, provided by installer) Bottom right Rear left Bottom left Insulate the refrigerant pipes separately with insulation, not together. Left 150 mm or more 8 mm thick heat resisting polyethylene foam 1000 mm or more 600 mm or more Optional Installation Parts Fixing bolt arrangement of outdoor unit Part code Parts name Q ty Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be exposed to a strong wind. Use 10 mm anchor bolts and nuts. A B C Refrigerant piping Liquid side : 6.35 mm Gas side : 15.88 mm Pipe insulating material (polyethylene foam, 8 mm thick) Putty, PVC tapes One each 1 One each 400 mm 365 mm 150 mm 525 mm 600 mm 150 mm 45 mm Drain nipple mounting hole 2

50 40 INDOOR UNIT Remote control 75 Installation Place A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor unit comes to at least 2 m height. Also, it must be avoided to put anything on the top of the indoor unit. Direct sunlight to the indoor unit s wireless receiver should be avoided. The microprocessor in the indoor unit should not be too close to RF noise sources. (For details, see the owner s manual.) A place where there are no obstacles such as a curtain that may block the signal from the remote control. Do not install the remote control in a place exposed to direct sunlight or close to a heating source such as a stove. Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference.) The location of the remote control should be determined as shown below. Indoor unit (Side view) Reception range Cutting a Hole and Mounting Installation Plate Cutting a hole Remote control (Top view) Indoor unit 35 120 180 240 The center of the pipe hole is above the arrow. Reception range When installing the refrigerant pipes from the rear 45 m from the right side edge is e center of pipe hole Pipe hole 45 Remote control 23 mm 65 mm 1. After determining the pipe hole position on the mounting plate (A), drill the pipe hole ( 65 mm) at a slight downward slant to the outdoor side. NOTE When drilling a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. Pipe hole Mounting the installation plate Offset 85mm from the left side edge is the center of pipe hole To unit out line 240mm To unit out line 35mm To unit out line 120mm 0 23 35 120 180 240 To unit out line 240mm 170 170 85 Indoor unit Thread 7 Mounting screw Weight When the installation plate is directly mounted on the wall 1. Securely fi t the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. 2. To mount the installation plate on a concrete wall with anchor bolts, use the anchor bolt holes as illustrated in the below fi gure. 3. Install the installation plate horizontally in the wall. Installation plate (Keep horizontal direction.) 5 mm dia. hole Clip anchor (local parts) Anchor bolt holes 7 Mounting screw 4 x 25 s Anchor bolt In case of block, brick, concrete or similar type walls, make 5 mm dia. holes in the wall. Insert clip anchors for appropriate mounting screws 7. Offset 23mm from the right side edge is the center of pipe hole Projection 15 mm or less 132 23 mm 2 m or more from fl oor Pipe hole ( 65 mm) 1 Installation plate When installing the installation plate with a mounting screw, do not use the anchor bolt holes. Otherwise, the unit may fall down and result in personal injury and property damage. Failure to fi rmly install the unit may result in personal injury and property damage if the unit falls. NOTE Secure four corners and lower parts of the installation plate with 4 to 6 mounting screws to install it. EN ES FR IT PL CZ RU CR HU TR NL GR SV FI NO DK RO BG EE LV SK SI 3

Wiring Connection How to connect the connecting cable Wiring of the connecting cable can be carried out without removing the front panel. 1. Remove the air inlet grille. Open the air inlet grille upward and pull it toward you. 2. Remove the terminal cover and cord clamp. 3. Insert the connecting cable (according to the local rule) into the pipe hole on the wall. 4. Take out the connecting cable through the cable slot on the rear panel so that it protrudes about 15 cm from the front. 5. Insert the connecting cable fully into the terminal block and secure it tightly with screws. 6. Tightening torque : 1.2 N m (0.12 kgf m) 7. Secure the connecting cable with the cord clamp. 8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor unit. Be sure to refer to the wiring system diagram labeled inside the front panel. Check local electrical cords and also any specifi c wiring instructions or limitations. Terminal cover Cord clamp Screw Terminal block 1. Die-cutting front panel slit Cut out the slit on the leftward or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers. 2. Changing drain hose For leftward connection, bottom-leftward connection and rear-leftward connection s piping, it is necessary to change the drain hose and drain cap. How to remove the drain hose The drain hose can be removed by removing the screw securing the drain hose and then pulling out the drain hose. When removing the drain hose, be careful of any sharp edges of steel plate. The edges can injuries. To install the drain hose, insert the drain hose fi rmly until the connection part contacts with heat insulator, and the secure it with original screw. How to remove the drain cap Clip the drain cap by needle-nose pliers and pull out. How to fix the drain cap 1) Insert hexagon wrench (4 mm) in a center head. 4 mm Heat insulator Drain hose 1 2 3 2) Firmly insert the drain cap. Screw Earth line 110 mm 20 mm Earth line No gap Insert a hexagon wrench (4 mm). Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Application causes deterioration and drain leakage from the plug. Firmly insert the drain hose and drain cap; otherwise, water may leak. about 15 cm NOTE Use stranded wire only. Wire type : H07RN-F or more How to install the air inlet grille on the indoor unit When attaching the air inlet grille, perform the same process as for removal but in reverse order. Stripping length of the connecting cable 10 mm 80 mm In case of right or left piping After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. In case of bottom right or bottom left piping After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Slit Slit Left-hand connection with piping Piping and Drain Hose Installation Piping and drain hose forming * Since dewing results in a machine trouble, make sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.) Rear right Rear left Bottom left Left Bottom right Right Die-cutting front panel slit Changing drain hose Piping preparation Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid exceeding 43 mm above the wall surface, the indoor unit may unstably be set on the wall. When bending the connecting pipe, make sure to use a spring bender so as not to crush the pipe. Bend the connecting pipe within a radius of 30 mm. To connect the pipe after installation of the unit (fi gure) 43 mm 520 mm 420 mm 80 (To the forefront of fl are) Gas side Liquid side Outward form of indoor unit R 30 mm (Use polisin (polyethylene) core or the like for bending pipe.) Use the handle of screwdriver, etc. 4

NOTE If the pipe is bent incorrectly, the indoor unit may unstably be set on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipes to the auxiliary pipes and wrap the facing tape around them. Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape. 2 1 Indoor Unit Fixing 1. Pass the pipe through the hole in the wall and hook the indoor unit on the installation plate at the upper hook. 2. Swing the indoor unit to right and left to confi rm that it is fi rmly hooked up on the installation plate. 3. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Pull the indoor unit toward you to confi rm that it is fi rmly hooked up on the installation plate. Auxiliary pipes Installation plate here. 1 Installation plate For detaching the indoor unit from the installation plate, pull the indoor unit toward you while pushing its bottom up at the specifi ed parts. Indoor unit Carefully arrange pipes so that any pipe does not stick out of the rear plate of the indoor unit. Carefully connect the auxiliary pipes and connecting pipes to one another and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint; moreover, seal the joint with the vinyl tape, etc. Since dewing results in a machine trouble, make sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.) When bending a pipe, carefully do it, not to crush it. Press (unhook) Push Push Information The lower part of indoor unit may float, due to the condition of piping and you cannot fix it to the installation plate. In that case, use the % screws provided to fix the unit and the installation plate. Drainage 1. Run the drain hose sloped downwards. NOTE The hole should be made at a slight downward slant on the outdoor side. 50 mm or more Do not rise the drain hose. Drain hose Do not put the drain hose end into water. Shield pipe Inside the room This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan. Therefore, do not store the power cord and other parts at a height above the drain guide. Do not form the drain hose into a wavy shape. % Screw % Screw Extension drain hose Space for pipes Do not put the drain hose end in the drainage ditch. 2. Put water in the drain pan and make sure that the water is drained out of doors. 3. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. Arrange the drain pipe for proper drainage from the unit. Improper drainage can result in dew-dropping. Wall Drain guide EN ES FR IT PL CZ RU CR HU TR NL GR Installation Place A place which provides enough spaces around the outdoor unit as shown in the diagram A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration A place where the operation noise and discharged air do not disturb your neighbors A place which is not exposed to a strong wind A place free of a leakage of combustible gases A place which does not block a passage When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. An allowable length of the connecting pipe is up to 25 m. An allowable height level is up to 10 m. A place where the drain water does not cause any problems OUTDOOR UNIT 1. Install the outdoor unit in a location where there are no obstructions near its air intake or air outlet. 2. When the outdoor unit is installed in a place that is always exposed to strong winds like on the coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield. 3. Especially in windy areas, install the unit to prevent the admission of wind. 4. Installation in the following places may result in trouble. Do not install the unit in such places. A place full of machine oil. A saline-place such as the coast. A place full of sulfi de gas. A place where high-frequency waves are likely to be generated, such as from audio equipment, welders, and medical equipment. Strong wind SV FI NO DK RO BG EE LV SK SI 5

Refrigerant Piping Connection Flaring 1. Cut the pipe with a pipe cutter. Die Pipe 90 2. Insert a fl are nut into the pipe and fl are the pipe. Projection margin in flaring : A (Unit : mm) A Tightening connection Align the centers of the connecting pipes and tighten the fl are nut as far as possible with your fi ngers. Then tighten the nut with a spanner and torque wrench as shown in the fi gure. Outer dia. of copper pipe Tightening torque 6.35 mm 16 to 18 (1.6 to 1.8 kgf m) 15.88 mm 65 to 80 (6.5 to 8.0 kgf m) Tightening torque of flare pipe connections Obliquity Roughness Warp Outer dia. A of copper pipe Rigid Imperial 6.35 1.0 to 1.5 1.5 to 2.0 15.88 1.0 to 1.5 2.0 to 2.5 Do not apply excess torque. Otherwise, the nut may crack depending on the conditions. Flare at indoor unit side (Unit : N m) 1. Connect the charge hose from the manifold valve to the service port of the packed valve at gas side. 2. Connect the charge hose to the port of the vacuum pump. 3. Open fully the low pressure side handle of the gauge manifold valve. 4. Operate the vacuum pump to start evacuating. Perform evacuating for about 15 minutes if the piping length is 20 meters. (15 minutes for 20 meters) (assuming a pump capacity of 27 liters per minute) Then confi rm that the compound pressure gauge reading is 101 kpa ( 76 cmhg). 5. Close the low pressure side valve handle of the gauge manifold valve. 6. Open fully the valve stem of the packed valves (both gas and liquid sides). 7. Remove the charging hose from the service port. 8. Securely tighten the caps on the packed valves. Compound pressure gauge 101 kpa ( 76 cmhg) Handle Lo Charge hose Packed valve handling precautions Pressure gauge Charge hose Vacuum pump Connecting pipe Manifold valve Handle Hi (Keep full closed) Vacuum pump adapter for counter-fl ow prevention Packed valve at gas side Packed valve at liquid side Service port (Valve core (Setting pin)) TO CHARGE REFRIGERANT Non refrigerant charging Less than 15 m Refrigerant charging 15 25 m (30g/m) Open the valve stem until it touches the stopper. Once it is in contact with the stopper, refrain from applying any more force than is necessary. Securely tighten the valve stem cap with torque in the following table: Externally threaded side Half uniont Flare at outdoor unit side Flare nut Internally threaded side Pipe side Tightening torque A Gas side ( 15.88 mm) Liquide side ( 6.35 mm) Service port 65 to 80 N m (6.5 to 8.0 kgf m) 16 to 18 N m (1.6 to 1.8 kgf m) 9 to 10 N m (0.9 to 1.0 kgf m) 5 mm 4 mm Hexagon wrench is required. A Use a wrench to secure. Use a torque wrench to tighten. KEEP IMPORTANT 5 POINTS FOR PIPING WORK. (1) Take away dust and moisture (inside of the connecting pipes). (2) Tighten the connections (between pipes and unit). (3) Evacuate the air in the connecting pipes using a VACUUM PUMP. (4) Check gas leak (connected points). (5) Be sure to fully open the packed valves before operation. Evacuating Wiring Connection 1. Remove the valve cover, the electric parts cover and the cord clamp from the outdoor unit. 2. Connect the connecting cable to the terminal as identifi ed by the matching numbers on the terminal block of indoor and outdoor unit. 3. Insert the power cord and the connecting cable carefully into the terminal block and secure it tightly with screws. 4. Use vinyl tape, etc. to insulate the cords which are not to be used. Locate them so that they do not touch any electrical or metal parts. 5. Secure the power cord and the connecting cable with the cord clamp. 6. Attach the electric parts cover and the valve cover on the outdoor unit. After the piping has been connected to the indoor unit, you can perform the air purge together at once. AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump. Do not use the refrigerant in the outdoor unit. For details, see the manual of the vacuum pump. Using a vacuum pump Be sure to use a vacuum pump with counter-fl ow prevention function so that inside oil of the pump does not fl ow backward into pipes of the air conditioner when the pump stops. 6

Electrical Work 1. The supply voltage must be the same as the rated voltage of the air conditioner. 2. Prepare the power source for exclusive use with the air conditioner. Stripping length of the connecting cable REFRIGERANT PIPING Knockout of Pipe Cover Knockout procedure Terminal block Earth line Cord clamp Round type terminal 60 Power supply cord 6 L N 10 100 Power supply cord 60 Earth line Terminal screw Round type terminal 6 Cord clamp 1 2 3 Screw 10 130 Rear direction Pipe cover PLATE-TRANSPORTATION Should be take off and no need to fi x. The indoor/outdoor connecting pipes can be connected in rear direction. Take off the knockout part of the pipe cover through which pipes Detach the pipe cover and tap on the knockout section a few times with the shank of a screwdriver. A knockout hole can easily be punched. After punching out the knockout hole, remove burrs from the hole and then install the supplied protective bush and guard material around the passage hole to protect wires and pipes. Be sure to attach the pipe covers after pipes have been connected. Cut the slits under the pipe covers to facilitate the installation. After connecting the pipes,be sure to mount the pipe cover. The pipe cover is easily mounted by cutting off the slit at the lower part of the pipe cover. EN ES FR IT PL CZ Cable tie Power supply cord Protective bush * Be sure to wear heavy work gloves while working. RU CR HU TR Model 30S (AR Series) 32S (AR Series) 30S (EG Series) Power source Maximum running current Plug socket & fuse rating Power cord 50Hz, 220-240 V Single phase 50Hz, 220-230 V Single phase 25A 27A 21A 30A 30A 25A 4 mm 2 (H07RN-F or 60245 IEC66) or 3.5 mm 2 (AWG-12) Supplied protective bush Supplied passage hole guard material * Attach the guard material securely so that it dose not come loose. NL GR SV FI Wrong wiring connection may cause some electrical parts burn out. Be sure to comply with local rule on running the wire from indoor unit to outdoor unit (size of wire and wiring method, etc.). Every wire must be connected fi rmly. If incorrect or incomplete wiring is carried out, it will cause an ignition or smoke. Prepare the power supply for exclusive use with the air conditioner. This product can be connected to the mains. Connection to fi xed wiring : A switch which disconnects all poles and has a contact separation of at least 3 mm must be incorporated in the fi xed wiring. NO DK RO BG NOTE : EE Wire type : More than 1.5 mm 2 (H07RN-F or 60245 IEC66) or 1.3 mm 2 (AWG-16) LV SK SI 7

OTHERS Gas Leak Test Test Operation To switch the TEST RUN (COOL) mode, press RESET button for 10 seconds. (The beeper will make a short beep.) Flare nut connections (Indoor unit) Hi POWER FILTER PAP TIMER OPERATION Service port cap connection Flare nut connections (Outdoor unit) Valve stem cap connection RESET button RESET Auto Restart Setting Check the flare nut connections, valve stem cap connections and service port cap connection for gas leak with a leak detection or soap water. Remote Control A-B Selection When two indoor units are installed in the same room or adjacent two rooms, if operating a unit, two units may receive the remote control signal simultaneously and operate. In this case, the operation can be preserved by setting either one remote control to B setting. (Both are set to A setting in factory shipment.) The remote control signal is not received when the settings of indoor unit and remote control are different. There is no relation between A setting/b setting and A room/b room when connecting the piping and cables. To separate using of remote control for each indoor unit in case of 2 air conditioners are installed near. Remote Control B Setup. 1. Press RESET button on the indoor unit to turn the air conditioner ON. 2. Point the remote control at the indoor unit. 3. Push and hold button on the Remote Control by the tip of the pencil. 00 will be shown on the display. 4. Press during pushing. B will show on the display and 00 will disappeared and the air conditioner will turn OFF. The Remote Control B is memorized. Note : 1. Repeat above step to reset Remote Control to be A. 2. Remote Control A have not A display. 3. Default setting of Remote Control from factory is A. This product is designed so that, after a power failure, it can restart automatically in the same operating mode as before the power failure. Information The product was shipped with Auto Restart function in the off position. Turn it on as required. How to set the Auto Restart 1. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds) 2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not blink) In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate. B Display 00 Display PRESET FAN 8