An MRI Centre An MRI centre shall be defined as a facility with the following minimum requirements as listed in sections A to G below:

Similar documents
A. General Safety LAB/ROOM: INSPECTED BY: DATE:

LABORATORY INSPECTION CHECKLIST

Laboratory Safety Audit

University of California, Davis Laboratory Self-Inspection Checklist

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

HEALTHCARE SAFETY INSPECTION

Laboratory Safety Audit

Laboratory Inspection (version 3) Criteria Action Plan

Laboratory Information

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

EMERGENCY RESPONSE PLAN FOR

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

1. Researchers are familiar with the location and contents of: The lab s Chemical Hygiene Plan YES NO

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

WTAMU Academic Research Environmental Health and Safety (AR-EHS) Laboratory Inspection Checklist

INFECTION PREVENTION AND CONTROL ENVIRONMENTAL AUDIT TOOL

Chapter 3: Emergency Planning for Laboratories

WORKPLACE AND SAFETY SIGNS

HEALTH AND SAFETY MANUAL

Laboratory Safety Laboratory Inspection Checklist

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

General Procedures: Materials Synthesis Lab 1358 CNAM/Toll

product guide 240 VOLTS NO ENTRY 240 VOLTS DANGER SAFETY SIGNS AND LABELS WE DESIGN IT - WE MAKE IT - IN AUSTRALIA

Employee Health Protection

LAB SAFETY FOR CUSTODIANS

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

APPLICATION FOR AUTHORISATION - PART 1

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Laboratory Inspection Checklist

MIT Emergency Response Guide

Safety In Chemistry. Identified Risks and Hazards

UNIVERSITY OF OXFORD FIRE RISK ASSESSMENT

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

EAST TENNESSEE STATE UNIVERSITY LABORATORY/CLINIC SAFETY INSPECTION PROGRAM

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety

Laboratory Inspection Checklist

WTAMU Academic Research Environmental Health and Safety (AR-EHS) Laboratory Inspection Checklist

Institutions NUMBER: Food Service Safety And Sanitation

The Beamsley Project RISK ASSESSMENT - CENTRE

The list is not exhaustive and where there is any doubt about the VAT status of items not included here please contact the UCL Tax Team.

DRAFT. Module 4. Decontamination & Environmental Cleaning

INSTRUCTIONS TO COMPLETE INSPECTION FORM:

MAINE. Downloaded g. Maintain an effective pest control program so that the facility is free of pests and rodents;

16.11 PARISH INSPECTION CHECKLIST

Jennings Street School

ISO 7010 INTERNATIONAL STANDARD. Graphical symbols Safety colours and safety signs Registered safety signs

HEALTH AND SAFETY INDUCTION CHECKLIST

Department Of Public Works: Internal Operations

Part B Health Facility Briefing & Design 150 Linen Handling Unit

-SAMPLE- Safety Inspection Checklist: Manufacturing

PURPOSE OF THE PROCEDURE

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

Florida International University. Biosafety Cabinet Program

WORKPLACE SAFETY INSPECTION CHECKLIST

AUGUSTANA MIQUELON LAKE RESEARCH STATION (AMLRS) WORKING ALONE PROCEDURES

SAFE ENVIRONMENTS/HEALTH & SAFETY MONITORING TOOL

OHS WORKPLACE INSPECTION (1) SCHEDULE AND RATINGS

Laser Class 4 Laser Type Nd-YAG Laser Manufacturer New Wave Research Laser Model SoloII-30 PIV Laser Serial / Id # Serial number 16582

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

INCA Head Start. Safe Environments Checklist

OH&S Purchasing Guidelines

Sample Facilities & Equipment WHS Checklist

Fire Risk Assessment

School EMERGENCY PLAN

Safety instructions and routines on lab Faculty of Odontology Malmö University

LABORATORY SAFETY. Discipline of Metallurgy Engineering and Materials Science Indian Institute of Technology (IIT) Indore DECLARATION

Fire Risk Assessment

Chemical Spill Control

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) Environmental and Occupational Health and Safety Manual

STUDENT SAFETY RULES

MONTHLY SAFETY INSPECTION REPORT

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST

Enclosure 4- RISK ASSESSMENT

Fume Hood Safety TYPES OF FUME HOODS

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

Class II Biosafety Cabinets

Department of Civil and Environmental Engineering University of Waterloo

Departmental New Employee Safety Orientation

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

University of Maryland Baltimore Environmental Health and Safety updated 1/3/2018 General Lab Inspection Common Findings and Corrective Actions

Office Safety Inspection Checklist

WORKPLACE EVALUATION CHECKLIST & REPORT

Safe Use of a Class II Biological Safety Cabinet

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Student Lab Procedures. Lab Safety Orientation

Health & Safety Induction. Faculty of Engineering Dr Julie Etches Faculty Safety Manager & Advisor

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Opening a Personal Service Premises in Manitoba

Quarterly Safety/Building Inspection Form

Freda M. Carter.

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

PART V: WORKING WITH LASERS

Transcription:

An MRI Centre An MRI centre shall be defined as a facility with the following minimum requirements as listed in sections A to G below: A. Personnel B. Services C. Premises - Physical Design, Layout, Furnishing and Ancillary Facilities D. Equipment Devices and Supplies E. Safety and Security F. Schedules G. Records A. Personnel The minimum qualification for the practitioner in charge shall be A registered Radiographer / Sonographer (3 years minimum post qualification experience and registered with Allied Health Professions Council). The additional staff Technicians full time, holding degree/diploma (2 years) from recognized institutions. B. Services Magnetic Resonance Imaging Any other requirement that may be prescribed by the Board. C. Premises Physical Design, Layout, Furnishing and Ancillary Facilities Information desk A waiting and reception area; separate from the radiation area Standard MRI room; Provision for changing room; Provision for washed clean linens; DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 1 of 9

A protective cubicle; One sizeable processing room equipped with a set of manual processors, including a drier; Backup of Generator, UPS, emergency light Washable floors with floor drains; Clean patients toilet and bath facilities with adequate water supply; Adequate general water supply; Constant electricity supply with alternative power supply in good working condition Approved certification for facilities with magnetic resonance imaging from the Nuclear Regulatory Authority. Any other requirement that may be prescribed by the Board. D. Equipment, Devices and Supplies MRI machine minimum 1.0 TESLA (Enclose a scanned copy of Supporting Document) Equipment for resuscitation of patient should be MRI compatible. Facilities for computer printer reports. Backup of Generator, UPS, Emergency light Automatic Film Processor Unit. Adequate workload minimum 100 MRI per month One MRI couch; 2 lead aprons; Hangers all sizes; Cassettes all sizes; MRI viewing box. Boyles trolley in protective cubicle in radiation room Equipment for resuscitation of patients like Boyle trolley, suction machines, emergency drugs, to combat any allergic reactions. Anesthetics Coverage during procedures involving IV contrast media use. DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 2 of 9

Sterilized instruments & disposable syringes needles, catheters for procedures like HSG, MCU, RGU etc. Wheel chair (s) should be able to go to equipment room Patient trolley (s) should be able to go to equipment room Provision for hard copy & computer printout reports Procedures for processing (transport, disposal) of used medical devices, supplies and equipment. Any other requirement that may be prescribed by the Board E. Safety and Security (Sections 1 to 12) 1. Structural a. Unobstructed access to facility b. Easily accessible to the disabled and aged c. Parking area d. Roof walls and ceiling intact e. Windows and Doors for facility intact with mosquito netting f. Facilities for storage of outer garments and personal items away from work area 2. General g. Adequate working space h. Clear separation of different general areas (reception, registration, consulting, diagnostics, observation areas) i. Separate work and storage areas are provided within the facility for processes/procedures, administration tasks and associated paperwork/reference material. a. Non-slip floors b. Unobstructed walkways, paths and corridors c. Adequate illumination d. Adequate ventilation 3. Signage a. Department/ Unit signs DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 3 of 9

b. Directional signs c. Warning signs d. Emergency evacuation diagram clearly displayed in all areas e. Entry and exit signs f. Hazard/safety signage on entrance/s clearly visible and contains information including: i. Authorized access only ii. No food or drink allowed iii. Type of chemicals iv. Supervisor contact details 4. Hygiene and Sanitation a. Fairly distributed number of pedal operated dust bins b. Means of decontamination of hands c. Posters on appropriate handwashing technique d. Posters on appropriate use of toilet facilities e. Signs for disposal of different types of waste f. Cleaning time tables for all rooms, offices and bathrooms 5. Protective Clothing and Gear a. Lead-lined aprons b. Thyroid & Gonads protective shield c. Masks d. Gloves e. Covered shoes f. Goggles /Protective eye gear g. Protective hair nets h. Protective laboratory coats i. Protective feet covers j. Provision for washed and clean linen 6. Biohazards a. Procedures for handling, storage, treatment, transportation and disposal of waste (colour codes for different waste etc) DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 4 of 9

b. Sharps disposal c. Consumables disposal d. Biological waste disposal e. Incineration procedures for biological waste f. Protocols and procedures for managing accidents with sharps g. Protocols and procedures for managing cross contamination 7. Emergency a. Exit doors clearly marked and can be opened from inside (not padlocked) b. Exit doors unobstructed from inside and outside the building c. Fire equipment (fire blanket, extinguisher, hose reel) is accessible and clear of obstruction d. Fire equipment (fire blanket, extinguisher, hose reel) have been inspected/tagged within the last 6 months. e. Fire exit and escape (for structures 2 storey and above) clearly marked and devoid of obstruction f. A first aid kit is located in the near vicinity. g. Smoke detectors are working and clear of obstruction. 8. Biosafety a. Procedures in place to account for all samples, reagents or materials b. Appropriate biosafety signage at the entrance to applicable units and on storage room doors/vessels c. A supply of disinfectant for decontamination purposes is available and is clearly labelled. d. Instructions for dilution of disinfectant is clearly displayed e.g chlorine solution e. Diluted bleach is stored away from heat and is kept in lightproof containers with the preparation date displayed. 9. Biosecurity a. There is appropriate signage at the entrance to all areas. b. All GMO and Quarantine samples labelled appropriately DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 5 of 9

c. All samples, reagents, liquids are appropriately stored in appropriate storage vessels and clearly labelled d. All samples are secondary contained (fridges and freezers count as secondary containment within a lab) e. Security arrangements are in place and various applicable areas have clearly marked restricted access f. Procedures are in place for the transport of materials g. All surfaces (including furniture) within the laboratory are smooth, impermeable to water and resistant to any decontaminant materials. h. There are locks on fridges and freezers. i. There are appropriate pest control procedures in place (spraying, weeding etc.) j. All windows and walls are intact and sealed and there are no gaps. 10. Chemicals, Handling and Storage a. Chemicals stored in appropriate containers. b. Containers are labelled correctly (e.g. not handwritten, label contains minimum chemical name and pictogram depicting hazard level). c. Chemicals are stored according to compatibility. d. Compatibility chart is readily available. e. Dangerous goods are stored under COSHH guidelines (Control of Substances Hazardous to Health). f. COSHH cabinets must be used, labelled and maintained in accordance with COSHH practices and other international best practices including but not limited to i. Self-closing and close fitting doors ii. Locking automatically (flammable) iii. Locking mechanism in 2 or more places (flammable/corrosive) iv. Self-releasing locking mechanism (oxidizing agents and organic peroxides) v. Clearance from ignition/heat sources (flammable, oxidizing agents, organic peroxides) DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 6 of 9

vi. Ventilation vii. COSHH approved labels for various hazards (toxic, danger to environment, corrosive etc.) 11. Flammable Liquids (if applicable) a. Must be stored in suitable closed vessels in limited quantities in fire resistant cabinets or bins designed to retain spills b. Cabinets to be located in designated well ventilated areas away from the immediate area for processing but not placed in a way to jeopardize the means of escape from other areas c. Must be stored away from other dangerous substances that can increase the risk of fire or compromise the integrity of the storage container or cabinet 12. Radiation a. Access to Designated Radiation Areas limited only to authorised persons. b. Suitable radiation/contamination monitoring equipment is available and in working condition. c. X-ray and other radiation producing equipment is kept in a room solely dedicated to it. d. Ionizing equipment is contained in appropriate enclosures. e. Enclosures have interlocks preventing users from being within the confines of the enclosure. f. Visible and audible signals are provided inside and outside enclosures to provide warning before and during irradiation. g. Fail-safe mechanisms are provided to prevent generation of X-rays. h. The laboratory is secured against unauthorised access. i. Radiation storage sites are lockable, secured and shielded as required. j. All work with radioactive material is segregated from other work. k. Spill trays and absorbent bench coverings are available. l. The counting apparatus is in a separate room. m. All containers are labelled appropriately. DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 7 of 9

n. Routine radiation monitoring of all technical staff & doctor through DRP/BARC o. The monitoring equipment has been calibrated and up to date. p. The radioisotope laboratory is placarded with i. The identification of the laboratory, ii. Main potential hazards, iii. Personal protective equipment is to be worn, iv. After hours contact name and phone number. F. Schedules Preventive maintenance schedules for the building housing the facility together with fixtures Preventive maintenance scheduled for equipment used in the facility Standard Operation Procedures Fire practices, drills, fire alarm tests and their results and action taken where applicable Any other applicable schedule or drill. G. Records Facility equipment records; Facility inspection records; Waste tracking log book; Occupational log books to record results of all staff investigations; Log books for recording accidents and injuries at the facility; Log books for recording potential and actual infections Routine (monthly/quarterly) data on ailments/illnesses/conditions reported at the facility Any other relevant records prescribed by the board DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 8 of 9

DIAGNOSTIC IMAGING TECHNOLOGY CENTRE REQUIREMENT Page 9 of 9