MAXIMA ULTRA 68 D _ BARRIERA AUTOMATICA AUTOMATIC BARRIER BARRIÈRE AUTOMATIQUE AUTOMATISCHE SCHRANKE BARRERA AUTOMÁTICA

Similar documents
MAXIMA ULTRA 35 D _05_ BARRIERA AUTOMATICA AUTOMATIC BARRIER BARRIÈRE AUTOMATIQUE AUTOMATISCHE SCHRANKE BARRERA AUTOMÁTICA

CELLULA FOTOCELLULA PHOTOCELL PHOTOCELLULE LICHTSCHRANKE FOTOCÉLULA FOTOCEL FOTOCÉLULA ΦΩΤΟΚΥΤΤΑΡΟ FOTOKOMÓRKA ФОТОЭЛЕМЕНТ FOTOBUŇKA FOTOSEL

Ditec DOR Folding doors operator

Ditec QIK80EH Electromechanical barrier (Translation of the original instructions)

Ditec DAS107PLUS User Manual IP2270EN.

Motorised swing doors User manual (translation of the original instructions) IP2225EN

ALT 4 ALT 6 ALT 4K ALT 6K

MOTOR FOR SLIDING GATES SERIE GR8 220V

Downloaded from

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

USE AND INSTALLATION HANDBOOK

IS141 Rev.03 15/12/2017. BG30 Series. Sliding gates automations USER GUIDE

FLAMA USER S AND INSTALLER S MANUAL

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

CombiGrinder. Instruction manual. Grinder for cattle, horse and pet clipper blades. swiss made. Version/Index: CombiGrinder/A 09-16

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

GUIDE TO INSTALLATION

52 BERKSHIRE CEILING FAN

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Installer: (Name, address, telephone number)

Performance Thermal Binder

Installation Instructions & Operating Manual IMPORTANT

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual.

48 TAYLOR CEILING FAN

Instructions Manual Manuel d Instructions Bedienungsanleitung Manual de instrucciones Εγχειρίδιο οδηγιών Руководство по эксплуатации

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

User and maintenance manual

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

PRODUCT DIAGRAM PACKAGE CONTENTS

FRULLATORE B210 BLENDER MIXEUR STANDMIXER BEDIENUNGS- UND WARTUNGSANLEITUNG BATIDORA MANUAL DE USO Y MANTENIMIENTO MANUALE D USO E MANUTENZIONE

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Installer manual AG-WL10

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Instructions for use

Parts Available from

Simplicity Bubbler Crathco Cold Beverage Dispensers

DHUM-12 E DHUM-16 E DHUM-20 E DHUM-30 E

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid.

AUTOMATIC GRANULAR ICE FLAKER

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

SPREMIAGRUMI MANUALE D USO E MANUTENZIONE

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Electric Milk Frother

52 CEILING FAN. Owner s Manual Models #50336, 50337

Flow Factor ~

Ditec VALOR R Sliding door installed in escape routes (Original intructions)

Single Induction Hob

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

STARLIGHT EXPRESS HEATED UNDERBLANKET

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012/19/EU

Deluxe Ice Crusher. Pour la version française veuillez consulter notre site de web

Installer: (Name, address, telephone number)

PROF. RANGE COOKER MODEL: EPRC-9850FE/SS EPRC-9860E/SS. Owner s Manual Please read this manual carefully before operating your set.

Multifunction Electric Can Opener

Professional HEPA Air Cleaner

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

1125 PIR Motion Detector

SMEG S.p.A. Via L. Da Vinci, Guastalla (RE) ITALY

Scrubbing machine. Use and Maintenance manual

Millo / Millo pro. Nr x000 / 1805-x000

52 STRATHMERE CEILING FAN

51AKB / 51 AKC OWNER S MANUAL

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

Bar Fridge USER MANUAL MB46W

INSTRUCTION MANUAL VARIABLE TEMPERATURE KETTLE MANUEL D UTILISATION BOULLOIRE À TEMPÉRATURE VARIABLE MANUAL DE USO HERVIDOR DE TEMPERATURA VARIABLE

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

FCP 20-V - 30-V - 40-V

GB User and maintenance manual

GDDEM10 DEHUMIDIFIER

PRODUCT DIAGRAM PACKAGE CONTENTS

User Manual. Spend a little Live a lot. TABLE TOP COOLER

Ice Maker. De Glaçons. Portátil PIM9W. Use & Care Guide Guide d utilisation et d entretien Manual de uso y cuidado. Portable.

AUTOMATIC MODULAR ICE FLAKER

Cleaning. Owner s Manual. RoboVac 11 SM-A438-V03. For FAQs and more information, please visit:

HRC / 2V HRC TA / 2V

T B A A

Ultra Speed Burnisher 120V & 240V with NEMA Plug

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

Installer: (Name, address, telephone)

MURELLE HE 110 R (M) User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Notice d installation et d utilisation Français. Instructions for installation and use English. Manual de instalación y de uso Español

Instructions. 1 Instructions

General safety precautions English

Contents. 1. Instructions for safe and proper use Positioning of hob Attachment to support structure Electrical connection 22

PresenceLight 180 PresenceLight 360

SLEEPWELL HEATED MATTRESS PROTECTOR

User Guide. Shaft Speed 6 6-Channel Shaft Speed Monitor. Calibration and Operation Software Reference UDJ701-5

General safety precautions English

P162A Wired PIR Motion Detector

Feed Table FT42. Operator s Manual

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

Assembly- and User Manual Electric Infrared- Patio Heater MODEL: Geda HS - 2 kw Art. Nr. HS 10000

Transcription:

D812171 00550_06 16-05-17 BARRIERA AUTOMATICA AUTOMATIC BARRIER BARRIÈRE AUTOMATIQUE AUTOMATISCHE SCHRANKE BARRERA AUTOMÁTICA ISTRUZIONI D USO E DI INSTALLAZIONE INSTALLATION AND USER S MANUAL INSTRUCTIONS D UTILISATION ET D INSTALLATION INSTALLATIONS-UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION 68 MAXIMA ULTRA 68 Attenzione! Leggere attentamente le Avvertenze all interno! Caution! Read Warnings inside carefully! Attention! Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur! Achtung! Bitte lesen Sie aufmerksam die Hinweise im Inneren! Atención Leer atentamente las Advertencias en el interior! Let op! Lees de Waarschuwingen aan de binnenkant zorgvuldig!

Index 1. General information 1.1 Introduction...pag. 10 1.2 General safety...pag. 10 1.3 General...pag. 10 1.4 Technical specification...pag. 10 1.5 Overall dimensions...pag. 11 2. Installation 2.1 Cable note...pag. 11 2.2 Fixing the structure...pag. 11 2.3 Springs mounting...pag. 12 2.4 Instal the arm...pag. 13 2.5 Align the arm...pag. 13 2.6 Balancing the arm...pag. 14 2.7 Optionals...pag. 14 2.8 Electrical connections...pag. 14 3. Use and maintenance 3.1 General safety...pag. 15 3.2 Warnings...pag. 15 3.3 Use...pag. 15 3.4 Manual manoeuvre...pag. 15 3.5 Routine maintenance...pag. 15-3 -

EN 1. General information 1.1 INTRODUCTION Please read it carefully before installing the appliance, before using it and before routine or extraordinary maintenance work. The notices preceded by this symbol provide important information, the non-compliance with such instructions voids the manufacturer s guarantee. OPERATIONS THAT, IF NOT CARRIED OUT CORRECTLY, CAN BE RISKY, ARE INDICATED WITH THE FOLLOWING SYMBOLS ELECTROCUTION CRUSHING The INSTALLATION, USE AND MAINTENANCE handbook is for installers, users and maintenance engineers The Company is not liable for injury to people or animals or damage to things in the case of applications that exceed the limits specified on the enclosed technical data sheet or by a use different from what the appliance has been designed. Warning! Observe all the instructions, improper installation can result in serious injury. 1.2 GENERAL SAFETY Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children s reach. Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted. Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3,5 mm. Check that a differential switch with a 0,03A threshold is fitted just before the power supply mains. The outputs are not of type SELV (separated extra-low voltage), therefore it must not be possible to reach them. Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying and shearing, according to and in compliance with the applicable directives and technical standards. The Company decline s all responsibility with respect to the automation safety and correct operation when other manufacturer s components are used. Only use original parts for any maintenance or repair operation. Do not modify the automation components, unless explicitly authorised by the Company. Instruct the product user about the control systems provided and the manual opening operation in case of emergency. Do not allow persons or children to remain in the automation operation area. Keep radio control or other control devices out of children s reach, in order to avoid unintentional automation activation. Do not allow children to play with the equipment. The equipment may be used by children aged over 8 years old and by people with reduced physical, sensory or mental capabilities, or without experience or the necessary knowledge, provided they are supervised or after they have received instructions relating to the safe use of the equipment and have understood the dangers inherent in it. Cleaning and maintenance meant to be performed by the user must not be performed by unsupervised children. Anything which is not expressly provided for in the present instructions, is not allowed. 1.3 GENERAL The automatic electromechanical barrier is designed to control passage openings up to 8 metres wide, for a maximum torque applicable to the bar shaft of 1150 Nm, in compliance with European standards. It is suitable for industrial applications and it is the ideal solution for managing vehicle traffic. 1.4 TECHNICAL SPECIFICATIONS Power...230Vac/115Vac ±10% 50/60Hz Motor...230Vac 900RPM 14uF 0.50kW Absorbed power...650w Control unit...csb-xtreme Impact safety...encoder Opening time...4.5 6.0 s ** Arm length...4 8 m Working temp...-30*** +60 C Manoeuvres in 24h...3 000 Protection level...ip 54-10 - Net weight...95 kg Gross weight...98 kg Sound pressure level...lpa 70 db (A) ** the opening times are considered from closed bar to slow down start *** With integrated heater active

1. General information / 2. Installation EN 1.5 OVERALL DIMENSIONS 590 590 170 360 60 400 360 RIGHT barrier 1155 1155 953 950 LEFT barrier 2.1 CABLE NOTE 1) Single-phase line 2 x 1,5 + E 2) Transmitter photocell 2 x 0,5 3) Receiver photocell 4 x 0,5 4) Flashing light 2 x 0,5 5) Key selector 3 x 0,5 6) Receiver 4 x 0,5 6) Antenna RG58 7) Magnetic coil 6 3 5 1 7 2 4 2.2 FIXING THE STRUCTURE 19mm 13mm 300 300 360 Ø80 400 500 600 400 Not supplied - 11 -

EN 2. Installation 2.3 SPRINGS MOUNTING 1 2 If single spring, mount in position 1 First mount spring 2 if present. 17mm Do not tighten before the balancing arm (see point 2.6) Mount spring 1. 17mm Do not tighten before the balancing arm (see point 2.6) - 12 -

2. Installation EN 2.4 INSTALL THE ARM M16x100 Ø16 Ø6x16 M10 Ø10 Ø8 M8x20 Ø10 M10x25 M8 Ø8 Ø16 M16 M6x10 Ø6 M6x16 M6x16 Ø6 TIGHTEN 210Nm M6x10 2.5 ALIGN THE ARM Electrically connect the control unit (see point 2.8) START Insert about 1 metre of the arm in the holder Give the START command to position the arm holder horizontally Pull the arm down to help the reducer counteract the force of the pre-calibrated spring Install the arm and adjust the holder Adjustable arm holder Check that the bar is in horizontal position USE THE ADJUSTABLE ARM HOLDER TO ALIGN THE ARM WITH THE ROAD. 2 x 17mm - 13 -

EN 2. Installation Give the START command to position the arm holder vertically Opening microswitch cam Check that the bar is in vertical position 3 mm 2.6 BALANCING THE ARM TO SET THE BOOM IN VERTICAL POSITION ADJUST THE OPEN LIMIT SWITCH CAM. 45 A 19mm Put the bar in a vertical position. For the A value see TAB.1 page 34 Check that the arm is balanced at ~45 2.7 OPTIONALS 2.8 ELECTRICAL CONNECTIONS ADDITIONAL LIMIT SWITCH CSB-Xtreme Consult the control unit s installation and operating manual - 14 -

3. Use and maintenance EN 3.1 GENERAL SAFETY The barrier is designed exclusively for vehicles traffic; report and delimit any walkways through a special sign. Keep adults, children and property out of range of the automated system, especially while it is operating. For safety reasons and to comply with current standards, we recommend using the control unit. To install follow the instructions given in the enclosed GENERAL INSTRUCTIONS FOR SAFETY sheet. All electrical connections must be done in compliance with current laws. The installer must instruct the user on how to use the automatism correctly, on the manual emergency manoeuvre and on the possible risks during operation. Analyse the risks and take all the appropriate measures to eliminate them, as prescribed by the EEC machine directive 2006/42, installing the safety devices. Always disconnect the electricity before attempting any work on the system with a lockable cut-off switch. Cleaning and maintenance meant to be performed by the user must not be performed by unsupervised children 3.2 WARNINGS Correct controller operation is only ensured when the data contained in the present manual are observed. The Company is not to be held responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present manual. The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the present publication. 3.3 USE It is essential to follow the instructions given in the enclosed GENERAL INSTRUCTIONS FOR SAFETY sheet. In the case of a manual emergency manoeuvre, follow the indications described in point 3.4. Consult the control unit s installation and operating manual. 3.4 MANUAL MANOEUVRE Always disconnect the electricity before attempting any work on the system Releasing the barrier WITH MOUNTED BOOM ONLY 3.5 ROUTINE MAINTENANCE (EVERY 6 MONTHS) Maintenance must be carried out by qualified personnel only. Check the condition of the barrier structure. Check tightness of the arm. Check the condition of the spring, chain and relative anchorings. Check arm balance. Check that at the end of travel the arm is horizontal and/or vertical Check operation of the control unit and safety devices. Check operation of the manual emergency manoeuvre. Record maintenance in the form on the page 35. - 15 -

REGISTRO DI MANUTENZIONE MAINTENANCE LOG Dati impianto Installation data Installatore Installer Cliente Customer Matricola Serial number Data installazione Installation date Data attivazione Activation date Luogo Location Nr. Data Date Descrizione intervento Intervention description Firma Signature 1 2 3 4 5 6 7 8 9

INSTALLATORE INSTALLER INSTALLATEUR INSTALLATEUR INSTALATOR DATA DATE DATE DATUM FECHA ITALY