Instrumentation Products and Applications

Similar documents
Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac- Carriers Type Universal

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Safe area; Zone 1 and Zone 2

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Product Information to the manual

SIL2-Interface/ -Signal Conditioners Series DuoTec

Model 144H. Product Data Sheet , Rev DB February Content

On the job around the clock 24/7: Fire detection systems

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

SITRANS T temperature transmitters A broad product family for every application. sitrans

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

FAHM Co. Temperature Transmitter PTT74 Series

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Operating Instructions Edition 02/2007

Temperature Measurement Transmitters for field mounting

Inductive slot sensor

Model 144H. Product Data Sheet , Rev DB February Content

Products and performance

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

PEPPERL+FUCHS GmbH

operational excellence Solutions for

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Dräger Polytron 7000 Fixed gas detector

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

explosion protection automation global partner of the process industry

Electronic Pressure Digest. Pressure and Temperature Transmitters

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

OOH740-A9-Ex Multi-sensor fire detector

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

polar zone components and systems for extreme temperatures

OOH740-A9-Ex Multisensor fire detector

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

RAYCHEM NGC-30 COMPONENTS

Certificate of Compliance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Level gauges Series LS Level indicator, switch and transmitter for liquids

FDOOT241-A9-Ex Multisensor fire detector

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Bionics Instrument. Alarm Handling. Gas Alarm Systems

INTERFACE AND SYSTEM SOLUTIONS. Explosion protection for automation

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

Technical Data. Dimensions

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Dependable Solutions for Gas Detection

Temperature Solutions Line Card

SET-2000 Hi Level/Oil

Assembly. Host Sub-D Alarm

Fire and Gas Monitoring Panel ST7-HV

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Intrinsically Safe Solutions

DB5 Intrinsically Safe Sounder Type DB-5

Today's world of increasing

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

SIFLOW FC070 Coriolis mass flow transmitter As easy to install as playing a CD. siflow

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

Tank Gauging System Special Safety Instruction

System 9000TS Sequence of Events Recorder

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Operating Instructions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Technical Data. Dimensions

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Temperature measurement with SITRANS T siemens.com/processinstrumentation

YOUR PARTNER IN FIRE & GAS DETECTION

MSI Safety relays. MSI-T functions

Temperature sensors SensyTemp TSP Measuring insets TSA

MODEL 9010/9020 LCD CONTROL UNIT

Analog Input Module IC670ALG630

OPTIBAR DP 7060 Supplementary Instructions

SUPREMATouch Modular Fire & Gas Detection System

Symphony Plus Combustion instruments

Building system automation. How to use

OilSET-1000 (12 VDC)

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

SET Installation and Operating Instructions. Level switch for one sensor

IECEx Certificate of Conformity

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

EXCELLENCE in Solutions Products Service

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

Fixed Gas Detection System/Meridian CERTIFICATION

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

Transcription:

1 1/0

Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems The instrumentation we have on offer is found on the following pages: Products, consultation and services concerning intrinsic safety. Benefit from our decades of experience in the development, manufacture and use of I.S. products. In Chapter 2 we present our selection of off-the-shelf safety barriers. In Chapter 3 you will find our I.S. interfaces with galvanic isolation in three different mechanical designs: for DIN rail mounting, Eurocards and plug-in modules. Since 1987 we have worked intensively with field bus technology: in Chapter 4 you will find everything that you should know about our fieldstation VOS 200. VOS 200? A remote I/O for installation in Zone 1. In addition, we present our newest product I.S. 1. Terminals for operating and monitoring in the industrial and explosionprotected version are illustrated in Chapter 5. Last but not least, we have combined consultation, system engineering and services for you in our Competence Center instrumentation systems (Turn to Chapter 6). 1/1

1 Instrumentation Products and Applications Product Overview Chapter 2: Safety barriers Page 2/1 Extensive program for standard instrumentation applications and for general applications 1 or 2 channels Exchangeable back-up fuse - one single nominal value for all safety barriers Snap-on mounting; simultaneous connection to potential equalisation/ground Short-circuit-proof Global certifications Chapter 3: I.S. Isolators Page 3/1 I.S. Isolators (DIN rail mounting) System with broad functionality Easy mounting on DIN rail or mounting plate Inputs or outputs, intrinsically safe [EEx ia] IIC Global certifications Galvanic isolation between input, output and power supply I.S. Isolators (Eurocards) Standard format Eurocard 19", 4 TE, 3 HE High packing density through multi-channel devices Simple plug-in mounting in racks Possibility of prepackaged mounting in system racks Client-specific system solutions I.S. Isolators (Modules) Simple, prepackaged assembly in module carriers with 16 or 32 signals Plug-in modules with many functions Field connections with plugs or plug-in terminals System cable to the control system Signal duplication or signal loo-pin via terminals Galvanic isolation between input, output and power supply Inputs or outputs, intrinsically safe [EEx ia] IIC Chapter 4: Remote I/O Page 4/1 Fieldstation VOS 200 Remote I/O for installation in Zone 1 Inputs and outputs, intrinsically safe I.S. AI, AO, HART, DI, DO, temperature, frequency HART communication with PC software Redundancy for field bus, central unit, power supply Hot swap under Ex-conditions for all units Communication: Modbus, Profibus DP etc. Mechanics, terminals, field housing freely configurable 1/2

Instrumentation Products and Applications Product Overview 1 Chapter 4: Remote I/O (continued) Remote I/O System Modular Remote I/O system for DIN rail mounting Installation in Zone 1 or Zone 2 / Div 2 or in the safe area Simple engineering through PowerBus Devices: BusRail, CPU & power module, various I/O modules Input and output. Intrinsically safe I.S. HART-communication for transmitters and control valves Redundancy for field bus and CPU & Power Module Hot swap under Ex-conditions for all modules Communication: Modbus, Profibus DP etc. Service bus for configuration, fault diagnosis, HART-communication Field housing freely configurable Chapter 5: Operating and Monitoring Systems Page 5/1 Terminals for industrial areas Various displays (text, graphics, colour graphics) Possibility of connecting bar code readers High functionality Simple and comfortable engineering Large selection of connections to PLC/DCS Integrated multi-lingual capability and help functions Terminals for hazardous areas For use in Zone 1 and Zone 2 Various displays (text, graphics, colour graphics) Possibility of connecting I.S. bar code readers High functionality Simple and comfortable engineering Large selection of connections to PLC/DCS Integrated multi-lingual capability and help functions Chapter 6: Instrumentation Systems Page 6/1 The competence center instrumentation systems completes our service. Here you will find engineers dealing with project management: Consulting Engineering Cabinet design and manufacture Commissioning Service Training 1/3

1 Instrumentation Products and Applications Applications Application / field device in Safety I.S. Isolators Remote I/O hazardous areas barriers in hazardous areas DIN rail mounting DIN rail Euro- Modules Euro- Modules mounting cards cards 2-wire transmitter 9002/13-280-110-00 9303/11 9601/.1 9103/.1 9541 9460 Page 2/6 Page 3/4 Page 3/61 Page 3/66 Page 4/8 Page 4/25 9001/51-280-091-14 Page 2/2 2-wire HART transmitter 9002/13-280-110-00 9303/13 9601/.3 9103/.3 9541 9461 Page 2/6 Page 3/4 Page 3/61 Page 3/66 Page 4/8 Page 4/25 9001/51-280-091-14 Page 2/2 2-wire SMART transmitter 9002/13-280-110-00 9303/15 9601/.5 Page 2/6 Page 3/4 Page 3/61 9001/51-280-091-14 Page 2/2 4-wire transmitter 9002/34-280-000-00 9318/11 9615/.8 9118/11 9541 9460 Page 2/6 Page 3/12 Page 3/61 Page 3/74 Page 4/8 Page 4/25 4-wire HART transmitter 9002/34-280-000-00 9541 9461 Page 2/6 Page 4/8 Page 4/25 i/p converter, control valve, indicator 9001/01-280-110-10 9311 9615 9111 9561 9465 Page 2/2 Page 3/8 Page 3/61 Page 3/70 Page 4/15 Page 4/25 9002/13-280-110-00 9318/12 9618 9118/12 Page 2/6 Page 3/14 Page 3/61 Page 3/76 i/p converter, HART control valve 9001/01-280-110-10 9318/16 9118/16 9561 9466 Page 2/2 Page 3/18 Page 3/78 Page 4/15 Page 4/25 9002/13-280-110-00 Page 2/6 1/4

Instrumentation Products and Applications Applications 1 Application / field device in Safety I.S. Isolators Remote I/O hazardous areas barriers in hazardous areas DIN rail mounting DIN rail Euro- Modules Euro- Modules mounting cards cards HART multiplexer 9148 9548 Page 3/84 Page 4/11 Resistance thermometer (RTD) 9002/22-032-300-11 9324 9623 9124 9543 9480 Potentiometer Page 2/4 Page 3/22 Page 3/62 Page 3/80 Page 4/10 Page 4/25 9002/22-093-040-00 9326 Page 2/4 Page 3/26 Thermocouple 9002/22-093-300-00 9324 9623 9124 9542 9481 Page 2/3 Page 3/22 Page 3/62 Page 3/80 Page 4/9 Page 4/25 9323 Page 3/20 mv signal 9002/22-093-300-00 9323 Page 2/3 Page 3/20 Contact, opto coupler output 9001/01-252-057-14 9350 9650 9150 9551 9470 Page 2/3 Page 3/36 Page 3/62 Page 3/86 Page 4/12 Page 4/25 9001/01-252-060-14 9250 Page 2/3 Page 3/30 9251 Page 3/32 NAMUR proximity switch 9350 9650 9150 9551 9470 Page 3/36 Page 3/62 Page 3/86 Page 4/12 Page 4/25 9250 Page 3/30 9251 Page 3/32 Pulse signal voltage 9001/03-280-000-10 9350/10-24 9650/.0-24 9150/10-24 9555 Page 2/5 Page 3/36 Page 3/62 Page 3/86 Page 4/13 1/5

1 Instrumentation Products and Applications Applications Application / field device in Safety I.S. Isolators Remote I/O hazardous areas barriers in hazardous areas DIN rail mounting DIN rail Euro- Modules Euro- Modules mounting cards cards Solenoid valve, LED indicator 9001/01-252-100-14 9351 9651 9151 9571 9475 Page 2/3 Page 3/40 Page 3/62 Page 3/90 Page 4/14 Page 4/25 9002/13-252-121-04 Page 2/3 Fire & gas detector 9001/01-280-165-10 9311/52 9615/.2 9111/52 9581 Page 2/5 Page 3/8 Page 3/61 Page 3/70 Page 4/16 9541 Page 4/8 Vibration sensor 9002/00-260-138-00 9307 Page 2/6 Page 3/6 Intrinsically safe field bus 9373/11 9503 9440 RS 485, RS 422 Page 3/48 Page 4/18 Page 4/25 9373/21 Page 3/50 Intrinsically safe field bus 9372/11 fiber optic Page 3/44 9372/21 Page 3/46 Intrinsically safe field bus 9375 IEC H1 Page 3/52 Intrinsically safe power feed of a 9004 9381 9581 load Page 2/5 Page 3/54 Page 4/16 1/6

Instrumentation Products and Applications Applications 1 Performance class Operating and Monitoring Systems Safe area Hazardous area Text MT-40 ET-4 MT-60 Page 5/5 MT-80 Page 5/4 Graphics MT-50 ET-6 MT-120 ET-9752 Page 5/4 Page 5/5 Visualisation MT-300 ET-8 Page 5/4 Page 5/5 1/7

1 Instrumentation Products and Applications Engineering Selection of I.S. interfaces - I.S. safety engineering Case I: Engineering of an I.S. interface with active input or output The I.S. interface should be selected such that the safe maximum values of the I.S. interface (U m, I m and P m) are less than, and the values C a and L a are greater than the safe maximum values of the field device. These values (U max, I max, C i and L i) are to be derived from the test certificate of the field device. Otherwise, the national standards for the installation of intrinsically safe circuits should be applied. U max ³ U m I max ³ I m P max ³ P m C i C a L i L a To be used for the following interconnections: Field device (selection) Isolator 2-wire transmitter Transmitter supply unit 9303 9601 9103 Control valve ma isolating repeater (I.S. output) 9311 9615/.1; 9615/.2; 9111 i/p converter 9318/12 9615/.4 9118/12 analog/digital indicator 9318/16 9618/12 9118/16 Fire & gas detector ma isolating repeater (I.S. output) 9311/52 9615/.2 9111/52 mv source mv isolating repeater 9323 Vibration sensor Isolating repeater for 9307 vibration sensors NAMUR proximity switch Switching repeater 9350/.0-1. 9650/.0-1. 9150/.0-1. 9250 9251 Solenoid valves Binary output 9351 9651 9151 Indicator light Intrinsically safe load Intrinsically safe power supply 9381 1/8

Instrumentation Products and Applications Engineering 1 Case II: Engineering of an I.S. interface with passive input The safe maximum values of the field device (U max, I max) must not exceed the maximum connectable values (U m, I m) of the I.S. interface. These values are to be derived from the respective test certificates. Moreover, the interconnection of field device and I.S. interface must not exceed the intrinsic safety limits (highest permissible values for total voltage, current, capacitance and inductance, see ignition curves). Otherwise, the national specifications for the installation of intrinsically safe circuits should be applied. U max U m I max I m P max P m To be used for the following interconnections: Field device (selection) Isolator 3/4-wire transmitter ma isolating repeater (I.S. input) 9318/11 9615/.8 9118/11 Pulse signal source Switching repeater 9350/10-24-10 9650/.0-24-10 9150/10-24-10 (with passive input) Case III: Engineering of an I.S. interface connected to a simple electrical apparatus Simple electrical apparatus: An electrical component or a combination of components of simple design with precisely known electrical parameters that does not affect the intrinsic safety of the circuit in which it(they) is(are) to be installed. Simple electrical apparatuses can be: a) Passive components, for example, switches, junction boxes, resistors and simple semiconductor components; b) Sources of stored energy with precisely known parameters, for example, capacitors or inductors, the values of which are taken into account, if the overall safety of the system is assessed; c) Energy sources, for example thermocouples and photocells that generate no more than 1,5 V, 100 ma and 25 mw. Inductors or capacitors that are contained in these sources must be taken into account as in b). Their interconnection with an I.S. interface is therefore likewise intrinsically safe (EN 60 079-14). Otherwise, the national standards for the installation of intrinsically safe circuits should be applied. To be applied for the following interconnections: Field device (selection) Isolator Thermocouples Multi-purpose transmitters 9324 9623 9124 mv isolating repeaters 9323 Resistance thermometers, Multi-purpose transmitters 9324 9623 9124 Potentiometers Resistance isolating repeaters 9326 Contacts, Switching repeaters 9350 9650 9150 opto coupler output 9250 9251 1/9