Resolution Compatibles Flex GSM IGM is a GSM cellular device that provides

Similar documents
Tech Support Line: (715) Concord 4 RE927X

SYSTEM ENHANCEMENT MODULE

BAT LTE SKU: IPD-BAT-LTE

BAT WIFI SKU: IPD-BAT--WIFI

RE6100 Series Helix Security and Automation Platform

SYSTEM ENHANCEMENT MODULE

GLOBAL. InstallatIon & operation manual

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Installation Instructions

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

NetworX NX-548E Receiver Installation Instructions

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Long Range Radio Alarm Transmitter

Long Range Radio Alarm Transmitter

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

X64 Wireless Training

GEM-P800 Programming Instructions

EVO192 v3.0 Fire and Burglary What s New

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

RESOLUTION PRODUCTS 2015 COMPATIBLES CATALOG

installation & operation manual

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

4-PGM Expansion Module

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

PC51O2-433NA v1.0 Installation Manual

Long Range Radio Alarm Transmitter

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

What s New. Installation Manual. Please see page ii. Version 2.X

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

8-zone Expansion Module

Now with 16.5 VAC Transformer Requires Compass Version A (or higher) for GSM Downloading

DSC PowerSeries NEO Quick Start Guide

Installation Manual RF55O1-433

SuperBus Hardwire Output Module (HOM) Document Number: Rev. D March 1999

Concord 5 TouchScreen Installation Sheet

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Uplink Remote Installation Guide 5500EZ

ThinkPro Security and Automation Panel User Guide

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Version 1.03 January-2002 USER S MANUAL

System Programming Guide

StarLink SLE Commercial Series Dual-Path Alarm Communicators INSTALLATION INSTRUCTIONS

SENTROL ZX200/ZX210. Security System Control. Installation/ Programming

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Ion Gateway Cellular Gateway and Wireless Sensors

JA-63 Profi User manual

Contents. Programming Worksheets 22. Appendix A: Guidelines for Locating Smoke Detectors 27. Index 28

PERMACONN PM1030 Includes DI300. Installation Manual

NetworX Series NX-870E Fire Supervision Module Installation and Startup

All-In-One Wireless Security System V1.0. Model #: MG-6060

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

SENTROL ZX400/ZX410. Security System Control. Programming

TELGUARD TG-4 CDMA. Revised August 14, PROPRIETARY INFORMATION For use by TELGUARD customers only. Distribution to others strictly prohibited.

LyricTM. Programming Guide. Controller. Ref: LCP500-L/LCP500-LC V1 11/15 Rev A

AXI LED USER MANUAL (REV. 1.0)

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Contents. Glossary

StarLink SLE-LTE Residential / Commercial Series Alarm Communicators INSTALLATION INSTRUCTIONS

Wireless External Alarm

Pet Immune SAW PIR Motion Sensor

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

ADEMCO LYNX XL SERIES Security System

Simon XTi Quick Operation Guide

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications S E C T I O N 1

1126 Series Ceiling Mount PIR Motion Detector

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

Caddx Installation Instructions Package

ADEMCO LYNX XL SERIES Security System

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Outdoor External Strobe Siren. ADD-ON DEVICE Quickstart Guide. What's inside: 1x Outdoor External Strobe Siren

System Manual W A R N I N G. PC6O1O Software Version 2.1

6HFXULW\6\VWHP,QVWDOODWLRQDQG6HW8S*XLGH N7227AUV2 12/99

RE6100 Series Helix Security and Automation Platform E I D

GEM-P800. Control Panel/Communicator. Installation Instructions

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

Property of Monitronics Inc

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

LYNX Touch Security System

Control/Communicator Installation Manual

PC4020 v3.2 Installation Manual DLS-3 v1.3

Impassa CDMA Module INSTALLATION GUIDE

Smart Security, Always Connected

Always Armed, Never Disarmed User Guide

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

FTP-1000 Touchpad/Display Installation Manual

Alula SOLUTIONS & SERVICES

Transcription:

RE927X 3G Flex GSM Interactive Gateway Module Resolution Compatibles Flex GSM IGM is a GSM cellular device that provides interactive services and home automation to existing security systems. Features Connects panels to the GSM cellular network Provides interactive services without panel replacement 5 year warranty Installation 1. Set up an account with your interactive services provider. Mounting Screw Locations 2. Mount the IGM to a wall using the mounting holes on the back plate. Do not mount inside of a metal can. The cellular antennas need to be in free air to communicate. Mount as high in the building as possible to optimize cellular strength. 3. Program the panel to use the IGM. (Refer to the programming section for your panel.) 4. Wire the panel to the IGM. (Refer to the programming section for a wiring diagram for your panel.) The IGM power supply must have a battery backup. Maximum cable length to the panel: 18 gauge wire = 350 feet 22 gauge wire = 130 feet 24 gauge wire = 75 feet G I INSTALL U E I D Wall Tamper (Do not over tighten mounting screw) Note: Be sure to verify that all report codes are being properly reported to the central station after you have installed the IGM module or modified any reporting program settings in the installer programming menu. Not Used Verify proper enrollment and operation using your control panel s installation manual.

Honeywell Vista 20P and Vista 15P, Vista 21IP Programming Compatible Panels Vista 20P version 4.0 or later (controls only partition one) Vista 15P version 4.0 or later Vista 21P version 3.13 or later 1. Set up an account with your interactive services provider. 2. Add a contact that uses the system MASTER CODE to the account before connecting the IGM. This is required for the IGM to be able to properly configure the system settings. 3. Disarm the system (all partitions). 4. The IGM automatically talks with the Vista using AUI 2, which is usually enabled by default. Enabling AUI 2 if not default: Enable AUI 2 in the *189 field. If another device is using AUI 2, that device must first be moved to a different AUI address. The other device should be moved to AUI 1 for Vista 15P and AUI 1, 3, or 4 for Vista 20P. 5. Vista panels that have a *91 field that supports RIS need to have RIS disabled. No action is required if RIS is not supported. 6. Use programming option *188 to disable keypad lockout. Keypad lockout: Vista 15P and 20P panel versions 10.21 and later have the keypad lockout feature enabled by default and it is recommended this feature be disabled to prevent possible keypad lockout conditions if the system master code in the IGM is not synchronized with the master code in the Vista panel. If it is required to have the keypad lockout feature enabled, it is critical that the system master code be set up as a contact for this account before connecting the module to the panel (see step 2 above). Also, all changes to the system master code must be done at the user portal or dealer portal, not at the keypad. Failing to do this may result in a keypad lockout condition. 7. Power down the Vista system. 8. Set IGM s panel selector switch to HONEYWELL. 9. Connect the Vista system and IGM as shown in the wiring diagram below. Note: For Vista 21IP panels, Internal IP/GSM jumper needs to be set to OFF. 10. Power up the Vista system and the IGM will automatically program it. Make sure all partitions are disarmed. The Vista system will be busy for 50-60 seconds after power up before it will automatically program. IGM will enable the following settings automatically: * IP/GSM device (*29) = 1 (enabled) * Communicate to IP/GSM device first (*55) = 1 (IP/GSM first) * Opening report (*65) = 1 (enabled) * Closing report (*66) = 1, 1 (stay closing and away closing reports enabled) * Alarm cancel report (*68) = 1 (enabled) * AC power restoral report (*73) = 1 (enabled) * Low Battery restoral report (*74) = 1 (enabled) * Phone Monitor (*92) = 0 (disabled) 11. Once the keypad(s) displays DISARMED Ready to Arm, installation is complete. IGM Honeywell Panel Black 4 AUX- Red 5 AUX+ Green 6 DATA IN Yellow 7 DATA OUT

DSC Power Series Programming Compatible Panels PC580 (Power 432) PC1555 (Power 632) PC1555MX (Power 632) PC5010 (Power 832) PC5020 (Power 864) PC5015 (Power 832) PC1616 PC1832 PC1864 1. Set up an account with your interactive services provider. 2. Add a contact that uses the system MASTER CODE to the account before connecting the IGM. This is required for the IGM to be able to properly configure the system settings. 3. Program the DSC panel using an INSTALLER CODE. Panel Programming Disable the IGM ([380]:[1]) Disable the Telephone Line Monitor ([015]:[7]) Delete Telephone Numbers (programming section 301-303) Verify Alt Comm ([351]:[5]) is enabled Verify T-Link is Disabled ([382]:[5]) Verify Master Code Not Changeable is Disabled ([015]:[6]) Verify Access Code Required for *1, *2, *3 menus is disabled ([022]:[1]) Verify that keypad lockout is either zero (disabled) or higher than 6 ([012]) If you have removed any bus devices, perform a Module Supervision Reset ([902]) 4. Verify alarm report codes are setup properly for zones that are being used, 1-64 (programming section 320-349). System will report as Burg (130) if programmed as FF. 5. If using Aux input (PGM2) verify Aux input report codes are setup properly (programming section 329:4). System will report as Fire (110) if programmed as FF. 6. To enable reporting of the Period Test Transmission, program the Periodic Test Transmission ([348]:[4]) and the Periodic Test Transmission with Trouble ([348]:[3]) reporting codes to 02. 7. All other reports are hard coded in the IGM and cannot be changed regardless of what is entered in the programmed location. Format and account number have no effect on reporting. 8. Disarm the system (all partitions). 9. Power down the DSC system. 10. Set IGM s panel selector switch to DSC/OTHER. 11. Connect the DSC system and the IGM as shown in the wiring diagram below. 12. Power up to the DSC system. The DSC control panel will begin automatic configuration. This can take up to 2 minutes. 13. Installation is complete. IGM DSC Panel Red Black Green Yellow AUX+ AUX- GRN YEL

DSC Panel Reporting Codes Event Report Code AC Fail/Restore 301 Panel Low Battery/Low Battery Restore 302 Opening/Closing Report 400 Cancel Report 406 Zone Alarm See below Keypad Fire Panic 110 Keypad Aux Panic 100 Keypad Police Panic 120 Duress 121 Periodic Test Transmission 602 Periodic Test With Trouble Transmission 608 Table of all events reported by the IGM when connected to a DSC panel. Zone Alarm Reporting Automatic Contact ID is not supported. Manually programmed reporting codes are only supported for alarms on zones 1-64 ([320] - [324]) and for alarms on the PGM2/Aux input ([329] option 4) which is reported as zone number 99. If Report Codes have not been manually programmed for zone alarms, zone alarm reporting codes default to the following: * Any zone alarm (zones 1-64): Code 1130 (Burglary) * PGM2/Aux input (zone 99, likely a 2-wire Smoke): Code 1110 (Fire)

Caddx NX Programming Compatible Panels All NX series panels 1. Set up an account with your interactive services provider. 2. Add a contact that uses the system MASTER CODE to the account before connecting the IGM. This is required for the IGM to be able to properly configure the system settings. 3. Disarm the system (all partitions). 4. Power down the NX system. 5. Set the IGM s panel selector switch to NX. 6. Connect the NX panel and the IGM as shown in the wiring diagram. 7. Power up the NX system and the IGM will automatically program it. IGM will enable the following settings automatically: * Enable opening and closing reports * Set telephone line cut delay to 0 (No TLM) 8. Installation is complete. Wait until the CS and platform LEDS have stopped blinking before entering program mode. Additional Notes for NX Installations Some NX panels limit the number of non-keypad devices that are supported. Be sure that the panel you are connecting the IGM to does not have more than the number of supported devices connected. User codes that are added to the system or edited thru the IGM will have the default or previous partitions enabled. If you desire the users to have different partitions enabled, you will need to modify the partitions thru the NX keypad. 6-digit access codes are not supported. IGM CADDX Panel Red POS KP Black COM KP DATA KP

Interlogix Concord Programming Compatible Panels Concord 4 1. Set up an account with your interactive services provider. 2. Add a contact that uses the system MASTER CODE to the account before connecting the IGM. This is required for the IGM to be able to properly configure the system settings. 3. Disarm the system (all partitions). 4. Program the Concord panel using an INSTALLER CODE. Panel Programming Turn off ACCESS CODE LOCK (0003) Delete phone numbers for CS1-CS3 (01000-01020) Turn on OPENING REPORTS for partition 1 (06100) Turn on CLOSING REPORTS for partition 1 (06101) 5. If there is an automation or wireless reporting device (i.e. automation module, cell backup module) already connected to the panel, remove the device and delete it from the panel. Concord 4 only supports 1 automation bus device. 6. Power down the Concord system. 7. Set the IGM s panel selector switch to INTERLOGIX. 8. Connect the Concord panel and the IGM as shown in the wiring diagram. 9. Power up the Concord system. Concord programming if first time powered with a IGM Do not press any keys on the keypad for the first 2 minutes after power up. After 2 minutes, initiate a bus scan (8 installer code+1). Do not press any keys on the keypad for 1 minute after you have performed the bus scan. 10. Installation is complete. Additional Notes for Concord Installations Be sure to turn off ACCESS CODE LOCK before adding the IGM. If the CS or Platform LED is still blinking, refer to Trouble Shooting the Panel Connection. It is normal for the keypad to display Enter Light Key a few times after connecting the IGM to the panel. If the keypad continues to display Enter Light Key, verify you have the correct system master code setup in the account. Interlogix Panel IGM GND 3 Red 4 A 5 B 6 Black Red

Paradox Programming Compatible Panels Paradox MG5050 1. Set up an account with your interactive services provider 2. Enter System Programming Menu on panel using Dealer Code (Default Code=0000) 3. Enter System Setup under the Menu Tab 4. Enter Advanced under the Installer Programming menu 5. Select System Programming under the Advanced Programming tab 6. Enter Section [911] under System Programming 7. Enter a PC Password (Ex. 9999) and hit Next PC Password Used for authentication so IGM can communicate with the panel This code will be entered into the dealer portal later Do not use the same code as the master code 8. Exit to main page by pressing the home icon in the top left corner of the screen 9. Power the system down 10. Set IGM slider switch to DSC/Other 11. Plug IGM into the serial connector via IGM-Paradox cable (sold separately) 12. Power the system up 13. From the Dealer Portal of your service provider, select Contacts tab and Edit master user 14. Add the panel s master code for User ID: Master (Default master code is 1234) 15. Enable master authority level for this master user 16. Select Users tab 17. Add User ID: Password using PC Password code entered earlier (Ex. 9999) IGM Data B Data A Ground Power Serial

Napco GEM Programming Compatible Panels GEM P816 GEM P1632 1. Set up an account with your interactive services provider. 2. Add a contact that uses the system DEALER CODE to the account before connecting the IGM. This is required for the IGM to be able to properly configure the system settings. 3. Disarm the system. 4. Program the Napco system using a DEALER CODE. Panel Programming Add an additional keypad. Program zone reporting codes. * Version 29 and older uses locations 0358-0373. * Version 30 and newer uses locations 0720-0735. * The IGM uses the left digit of the data entry to generate reporting codes for each zone Verify the DEALER CODE entered on the online portal matches the code in the panel. This step is only required on PANEL VERSION 30 OR NEWER. * Disable Enable Keypad 1 Only Programming. (Location 2053, bit 7) 5. Exit dealer programming, 6. This step is only required on PANEL VERSION 29 OR OLDER. Move keypad 1 to a different keypad address as this will allow the IGM to program the Napco panel. Steps to Move Keypad 1 to a Different Keypad Address Power down the Napco system. Find the mode jumper located on the Napco panel board. Move the mode jumper to the CONFIG state. Power up the Napco system. The display should show 01 OUT OF SYSTEM. Press 1 1 1 2 3 + FUNCTION. Cycle through the menu until you see Keypad Address. Change the keypad address to an open keypad location. Press enter or on/off to save the entry. Power down system and move the mode jumper back to NORM. 7. Set IGM panel selector switch to DSC/OTHER. 8. Connect the Napco system and IGM as shown in the wiring diagram. Be sure to add a jumper wire between TX and RX. 9. Power up the Napco system and the IGM will automatically program it. Make sure all partitions are disarmed. Programming starts as soon as a connection is made to the interactive server. Once the connection is made programming will last roughly 3 minutes. IGM will read the following data fields. Access Codes, Reporting Codes, Enable Global Ambush Code, Global Ambush Code IGM will change the following data fields. CS Receiver 1 Format (C Ademco Point ID ) 10. The keypad(s) should display SYSTEM READY. 11. Installation is complete. IGM Napco Panel Red 9 RED Black 10 BLK Green 11 GRN Yellow 12 YEL Jumper Wire

Napco GEM Programming Compatible Panels GEM P800 GEM P801 1. Set up an account with your interactive service provider. 2. Add a contact that uses the system DEALER CODE to the account before connecting the IGM. This is required for the IGM to be able to properly configure the system settings. 3. Disarm the system. 4. Program the Napco system using a DEALER CODE. Panel Programming Program zone reporting codes. Programming location 61. Note: The following zone types will be treated as 24-hour zones: (1) Fire, (2) Panic, (4) Hold- Up (7) Gas Alarm, (8) Heat Alarm, (B) 24-hour alarm Verify the Dealer Code entered on the online portal matches the code in the panel. Disable telco reporting for zones 1-8. 5. Exit dealer programming. 6. Power down the panel. 7. Set the IGM panel selector switch to DSC/OTHER. 8. Power up the Napco panel. The IGM will automatically program it. make sure all partitions are disarmed and dealer programming has been exited. Programming starts as soon as a connection is made to the interactive server. Once the connection is made programming willl last roughly 1 minute. IGM will read Access Code 1, Reporting Code Configuration. 9. The keypad(s) should display SYSTEM READY. 10. Installation is complete. IGM Napco Panel Power PWR 16 Ground GND 17 Data DATA 18

Texecom Programming Not yet supported, coming soon.

Operation Events are reported to both the monitoring receiver and the interactive server. All events use Contact ID reporting codes. Events reported by default Alarms Alarm cancels Openings Closings System Low Battery System Low Battery Restoral AC Power Fail (delayed by some panels) AC Power Restoral (delayed by some panels) Honeywell Vista panels can enable additional event reporting by using system programming. Remote control of the system can be done through the interactive services platform. Arming/Disarm control and status apply only to partition 1. Z-Wave devices can be controlled using the interactive services platform. approxi- Factory default button will reset the IGM if held for 5 seconds, and if held for mately 10 seconds will factory default the IGM. LED flashes twice when the IGM is factory defaulted. Cellular LED indicators LED Power (Green) Cellular (Red) CS (Red) Platform (Yellow) Indication Flashing off once every second - Primary Mode Flashing off once every three seconds - Backup Mode ON - Registered with the local cellular network ON - Connected to central station Blinking - Problem detecting panel type ON - Connected to panel and interactive server Blinking - Problem communicating to the panel Cellular signal bar LEDs indicate the quality of the cellular connection. A minimum of two signal bar LEDs is recommended. Number of Signal Bar LEDs Cellular Signal Strength Lit 0 Bad (0 to 6) 1 Marginal (7 to 9) 2 Acceptable (10 to 12) 3 Good (13 to 17) 4 Best (17+)

Troubleshooting Symptom Platform LED Blinking Troubleshooting Steps General 1. Incorrect wiring 2. Incorrect panel switch position 3. Unsupported panel version 4. Unsupported panel model 5. Panel is in Installer Program Mode Honeywell Vista 1. AUI not enabled 2. AUI used for some other function 3. LRR not enabled 4. Another LRR or IP/GSM device connected to panel bus Interlogix Concord 4 1. Module not enrolled into the Concord Bus (perform another bus scan) 2. Another Automation device is enrolled on the Concord Bus NX 1. Some NX panels limit the number of non-keypad devices they support. Be sure that the panel you are connecting the IGM to does not have more than the number of support devices connected. (i.e. some NX-4 panels only support 1 module in addition to keypads so they cannot support both an IGM and a wireless receiver. ) Symptom CS Light Blinking CS Light Off Both Lights Off Supervisory Trouble Information Troubleshooting Steps 1. Verify the panel selection switch location 2. Verify wiring 3. Verify the panel is supported by the gateway (both panel type and version) Ensure an account has been created and activate at the central station or monitoring station. If registration information changes after the IGM is powered up, perform a factory default. Ensure an account has been created and that it is active/live. If registration information changes after the IGM is powered up, perform a factory default. Honeywell- LRR Fault/bF error - Verify panel is 4.0 or later.

Troubleshooting Cellular communication problems can be solved in many ways: Make sure antenna is securely screwed into the circuit board connector Reposition the unit (move or rotate) Move the unit higher in the building Move the unit away from metal objects (appliances, ducts) Move the unit closer to a window Move to one of the below higher performance antenna options Antenna Options Internal antenna - RE040 Good Performance Offers a compact solution Wall drop antenna - RE034 and RE034-0 Better performance Antenna can be hidden in the wall

Side mount antenna - RE041 Best performance Offers optimal cellular performance Approved side mount antennas Antenna Nearson Taoglas Multi-Tech Systems Inc. Pulse Larsen Antennas Abracon Model T6155AM-LTE-S TG.30.8111 ANLTE2-10HRA SPDA24700/2700 APAMPSLJ-140

This Page Intentionally Left Blank

Specifications Physical Housing Dimensions Weight Mounting Fastener Reported Indications Current Draw 8.5 x 5.0 x 1.3 inches 10.0 ounces #4 or #6 (not provided) Cover Tamper, Wall Tamper 200mA (Nominal) Environmental Operating Temperature Maximum Humidity 32 F to 120 F 85% non-condensing relative humidity Panel Compatibility Honeywell DSC Caddx Interlogix Napco Paradox Texecom Vista 15P, Vista 20P PC580 (Power 432), PC1555 (Power 632), PC1555MX (Power 632), PC5010 (Power 832), C5020 (Power 864), PC5015 (Power 832), PC1616, PC1832, PC1864 All NX series panels Concord 4 GEM P800, GEM P801, GEM P816, GEM P1632 MG5050 None yet Models RE927X-00-00 RE927X-01-00 Flex GSM IGM Flex GSM IGM with Zwave Certification RE927X FCC, PTCRB Specifications subject to change without notice WARRANTY Alula will replace non-portable products that are defective in their first five (5) years and portable products that are defective in their first two (2) years. FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Alula could void the user s authority to operate this equipment. RF Exposure: To satisfy FCC RF Exposure Requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. TRADEMARKS ALULA IS A TRADEMARK OWNED BY ALULA HOLDINGS, LLC. GE, INTERLOGIX, HONEYWELL, DSC, 2GIG, QOLSYS AND, NAPCO ARE TRADEMARKS OWNED BY GENERAL ELEC- TRIC COMPANY, UNITED TECHNOLOGIES ELECTRONIC CON- TROLS INC., HONEYWELL INTERNATIONAL INC., TYCO SAFETY PRODUCTS CANADA LTD, NORTEK SECURITY & CONTROL LLC, TYCO SAFETY PRODUCTS CANADA LTD, NAPCO SECURITY TECH- NOLOGIES, INC., RESPECTIVELY. ALULA. PRODUCTS WILL FUNCTION WITH ONE OF EITHER INTERLOGIX (FORMERLY GE), HONEYWELL, DSC, 2GIG, QOLSYS OR NAPCO SYSTEMS. HOWEVER, NO ALULA PRODUCT IS PRO- DUCED BY, ENDORSED BY, NOR IS OFFICIALLY ASSOCIATED WITH INTERLOGIX (FORMERLY GE), HONEYWELL, DSC, 2GIG, QOLSYS OR NAPCO. ALULA RECOMMENDS VERIFYING PROPER ENROLL- MENT AND OPERATION, PER CONTROL PANEL INSTALLATION INSTRUCTIONS, AT INSTALLATION. 47-0043-00 RevB 2018-04-10 Tech Support Line (888) 88-ALULA (888) 882-5852 alula.net