WM3000 WIRELESS MODULES

Similar documents
Installation and ZONES: Operation Manual. Model: ON STI-34108

Rev D 3/20/17

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

EW 40 Wireless Fan Control

Fire / CO Alarm Interface

WIRELESS COLOR FORECAST STATION

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Rack Mount Series Installation Guide

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Agri-Alert 800 EZe Alarm System Owner s manual

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

HomeLink Wireless Control System

Long Range Radio Alarm Transmitter

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

1126 Series Ceiling Mount PIR Motion Detector

Installation & Operating Instructions

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Atomic Projection Alarm Clock

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Installation Guide for models:

Wireless Weather Station. Table of Contents

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

CAUTIONS ON INSTALLATION

WatchDog Wireless Crop Monitor Operation Manual

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Exit Stopper. STI-6400 Series

L. Terminal block Connecting Label:

WIRELESS COLOR WEATHER STATION

Wireless Color Weather Station

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

2G & 3G GSM Portable PIR Alarm

Campers Alert TM Portable System Hunters Alert TM Portable System

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

WIRELESS FORECAST STATION

Beacon 410A Gas Monitor Operator s Manual

AURATON 2005 / 2005 TX

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

NetworX NX-548E Receiver Installation Instructions

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Sidekick II Receiver Model # SK2-SS 418MHz

Beacon 800 Gas Monitor Operator s Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

20 Light Remote Annunciator

Addendum for STI-6406 with Dual Access Control

Exit Stopper. STI-6400 Series

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

G34 AU1B (External Ultrasonic Sensor) Version 3

Wireless Driveway and Intruder Alert

Honeywell Temperature & Humidity Sensor with LCD

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

QUICK INSTALLATION GUIDE

Home Doorway Alert Kit

Helios W.E.S & 2000 (Wireless Emergency Stop) User Guide. E6, Version 1.2. Helios Global Tech Ltd.

Installation Guide for models:

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

WIRELESS COLOR FORECAST STATION

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Agri-Alert 800EZe. Alarm System. Alarm. System in Standby. Burglary Armed. Online (phone) Green = zone activated Amber = zone bypassed.

Pioneer-R16 Gas Monitor Operator s Manual

Long Range Radio Alarm Transmitter

Secure WANDERING INSTALLATION AND USAGE GUIDE

WIRELESS WEATHER STATION

4100U City and Relay Cards Installation Instructions

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

FEATURES AND SPECIFICATIONS

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

WIRELESS COLOR WEATHER STATION

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Model 4001 Series Single Channel Controller

EVO192 v3.0 Fire and Burglary What s New

Keys for base station: 1. MODE 2. CHANNEL 3. MAX/MIN 4. UP/(C/F) 5. SET/(AL.ON/OFF) 6. DOWN/(12/24) 7. SNOOZE 8. ALERT 9. RESET

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

CO2Sensor Basic / ES 999

1125 PIR Motion Detector

Color Forecast Station. Table of Contents

Ion Gateway Cellular Gateway and Wireless Sensors

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Booster Power Supply Manual

High Resolution Display WIRELESS COLOR WEATHER STATION

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Digital Thermometer with Ice Alert and Clock

English. Series. Installation and Use Manual

PRODUCT DIAGRAM PACKAGE CONTENTS

2G & 3G GSM Wireless Beam Alarm

Water Tank Level Monitor

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Mobeye CM2410 GSM fire alarm communicator

Transcription:

WM3000 WIRELESS MODULES $$:05 $$:07 INSTALLATION INSTRUCTIONS

Table of Contents Installation... 3 Mounting Instructions & Connections... 3 Setting the Dip Switches... 4 Setting the Recognition Time... 4 Testing... 5 Alarm Signals... 7 Technical Specifications... 7 Wiring Diagram... 8 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice due to further developments. This device complies with Part 15 of the FCC rules, operation of this device is subject to the following conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation. 2 AA-WM3000 rev.02

The AA-WM3000 wireless modules are designed for use with the AA 800T, the AA 2400, and the AA 9600 Agri Alerts. Installation Mounting Instructions & Connections 0. Mount the Agri Alert and the power pack in the desired location. 1. Locate the AA-WM3000Rx close by in a suitable location so there are the least amount of obstructions to the transmission signal between the Rx and the Tx. 2. Check that the on/off switch (Fig.1, #2) of the receiver is in the off position. 3. Connect the 12vdc power cord supplied with the receiver, to the fused Aux. 12 volt dc supply in the Agri Alert. Be careful to observe the correct polarity when making the connections. 4. Plug the other end of the power cord into the receiver. (Fig. 1, #3) 5. Connect each one of the channel relay outputs (Fig.1, #4) to a separate zone input on the Agri Alert. 6. Program the zone types in the Agri Alert as Dry Contact with the appropriate N/O or N/C, W or W/O ELR designations. Program the zone Recognition Times to (2) two seconds. 00:00:02. (Caution: programming the recognition times at more than 3 seconds will prevent the Agri Alert from getting the signal from the receiver relay when an alarm occurs.) 7. Locate the transmitters in the desired locations again being careful to choose a location that will have the least amount of signal obstructions between it and the receiver. 8. Connect the 9 volt battery supplied, to the connector (Fig 2, #10) and properly secure the battery in the holder provided (Fig.2 #9). 9. Set the dip switches as explained in the following section. AA-WM3000 rev.02 3

Setting the Dip Switches 1. Set the 8 dip switches (Fig.1, #1) on the receiver to the desired positions. Each receiver must be set to a different switch combination. (There are 256 possible combinations to choose from.) 2. Set the first 8 dip switches on the transmitter (Fig.2 #5) to the same positions as the settings on the receiver that it is going to be transmitting signals to. 3. Set the last switches 9 & 10 (Fig.2, #6) according to the channel desired in the receiver (see chart below). Switch 9 Switch 10 Channel ON ON 1 OFF ON 2 ON OFF 3 OFF OFF 4 Setting the Recognition Time The recognition time is the time an alarm input must be active before it constitutes a valid alarm condition. To set this delay, place the Recognition Time jumper at the right position on the circuit board of the transmitter: 0 or 30 seconds. Recognition Time Jumper JP1 JP1 0 second 30 seconds 4 AA-WM3000 rev.02

Testing 1. Be sure that the Agri Alert is powered up and that the appropriate zones are activated. 2. Turn on the receiver by pushing the on/off switch (Fig.1, #2) to the on position. The red LED light should now be on. (Fig.1, #11) 3. At the transmitter, set the Recognition Time jumper (Fig.2, #7) to 0 second. Close up then enclosure then press the test push button (Fig.2, #13) on the outside of the box. When the push button has been activated, the transmission LED (Fig.2, #12) lights up for 4 seconds and the Low Batt LED (Fig.2, #14) lights up at low intensity while pressing the button. 4. Check that the receiver has actually received the signal and that the proper channel has activated. This must also result in the zone on the Agri Alert being triggered. Be aware that the channel relay (Fig.1, #4) in the receiver will only be activated for a period of 4 seconds on each transmission from a transmitter that is assigned to it. This will mean that when you acknowledge an alarm from a wireless zone in the Agri Alert, the alarm zone may appear normal again. This is because the channel relay has already reset itself. Use the alarm memory key to review the alarms that have occurred. (You could also adjust the alarm reset time in the Agri Alert to a higher value if desired.) 5. Each transmitter must be tested for proper functioning and signal transmission. The receiver must receive the signal each time the transmitter is triggered or the transmitter should be relocated. In some cases, it may be best to relocate the receiver as well. 6. When you are satisfied with the location of the transmitters, connect the alarm sensors (normally open) to the input terminals (Fig.2, #8) on each transmitter. 7. Finish your testing by creating an actual alarm condition at each sensor and ensuring that the desired result is achieved at the Agri Alert. 8. Remember to place the Recognition Time jumper back to the proper setting when your tests are complete. AA-WM3000 rev.02 5

Important Notes Whenever changes have been made to the Recognition Time jumper or to any of the dip switches on the receiver or on the transmitters, the on/off switch on the receiver must to moved to the off position and then back to the on position. This will reset the receiver and will ensure that it is properly aligned with the transmitters that are programmed to it. Always perform a test after making any changes to the dip switches or any of the jumpers. - For maximum range between the transmitter and receiver, the receiver should be mounted horizontally on a wall and as high off the floor as possible. - The input configuration to the WM3000Tx must be a normally open dry contact for this unit to function properly. - Although the maximum range is about 3000 feet, things such as hills, trees, metal siding and stucco can all reduce the range. - Battery life in the transmitter will largely depend on how many times the transmitter is required to operate and the battery s ambient temperature. - As a precaution, test the battery regularly by sending a test transmission. Under normal conditions the expected battery life is approximately 1 year and therefore it is recommended that the battery be replaced after one year. Test the transmitter to know if it is working properly. - Use discretion when choosing wireless alarm transmission over hardwired systems. Due to the inherent risks of using wireless battery operated equipment, the customer must be aware of, and willing to accept the limitations involved with this equipment. 6 AA-WM3000 rev.02

Alarm Signals The WM300Tx sends an alarm signal to the WM3000Rx (and the Agri Alert) when one of the two following situations occurs: Relay Activation When the device connected to the input terminals of the transmitter is activated (the normally open contact closes), the WM3000Tx waits for the Recognition Time and then sends an alarm signal to the WM3000Rx (and the Agri Alert). The WM3000Tx will re-transmit the alarm signal every 10 minutes for as long as the signal is present at the input terminals. Low Battery The WM3000Tx also sends an alarm signal when the transmitter s battery is too low. In this case, the Low Battery pilot light located in the transmitter slowly flashes at low intensity. The WM3000Tx sends the alarm signal to the WM3000Rx (and the Agri Alert) every 30 minutes for a low battery. Technical Specifications Frequency 433.92 MHz Type of modulation: FSK modulation Power output: 10 mw Operating voltage: 12VDC 12 volt DC output current: 400 ma maximum Relay output rating: 24VDC at 3 Amp AA-WM3000 rev.02 7

Wiring Diagram 1 Dip switches [Receiver] ANTENNA 1 11 3 2 2 On-Off switch [Receiver] 3 Power cord connector [Receiver] 4 Channel relay outputs [Receiver] ON OFF CH 1 CH 2 CH 3 CH 4 CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 12 V OUT ON OFF 5 Dip switches 1-8 [Transmitter] 6 Dip switches 9-10 [Transmitter] 7 Recognition time jumper [Transmitter] 8 Input terminals [Transmitter] 9 Battery holder [Transmitter] NO NC COM NO NC COM NO 4 NC COM NO NC COM + - POWER 10 9 7 12 5 6 ANTENNA BATTERY JP1 0 Sec 30 Sec 10 Battery connector [Transmitter] 11 Status LED [Receiver] 12 Transmission LED [Transmitter] 13 Push button [Transmitter] 14 Low Battery LED [Transmitter] Figure 1: Receiver 14 SW0 SW1 OUT + OUT - ON OFF 910 8 13 Figure 2: Transmitter 890-00428 rev. 02 REV. 02