EFBW series - BiWire Ultra control panel

Similar documents
Industries. As a premier global manufacturing company, we believe that great brands are

Eaton is a global leader with expertise in:

Cooper Industries (UK) Ltd

Conventional systems Product Name

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Conventional Fire Detection

Installation and user manual for the BiWire / Conventional Repeater Panel

Fire Product Catalog

Xenex Conventional Fire Detection & Alarm System

The complete conventional fire warning system

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Fire Signalling. Signalling Solutions

System 800 Addressable Fire Detection & Alarm System

Addressable and Conventional Fire Protection

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

4 wire conventional alarm system

Emergi-Lite Orbis detectors

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

MINERVA MZX125 Digital Addressable Fire Detection System

Conventional Smoke Detectors KFAPO

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation, Operating and Maintenance Manual

5000 INSTALLATION GUIDE

ELECTRONIC SOUNDER STROBE Model : AVD-C407

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Control Panel Engineering and Commissioning Instructions

Sita200plus. 200detectors. Single loop analogue addressable System

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Conventional Audible Visual Range

MINERVA MX. 800 Series Ancillary Equipment

Fire Signalling. Signalling Solutions

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Fire Signalling. Signalling Solutions

Touch Screen 1 loop Addressable Fire Alarm Panel

Opal TM AV Devices. Data Sheet. Benefits

Cooper Fire Systems. UL Listed Range

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

OPERATION AND INSTALLATION MANUAL

Wireless Fire & Security Solutions. Fire Product Showcase

Door Release Power Supply

intelligent solutions

INPUT / OUTPUT MINI MODULES

Excel-EN Conventional Fire Control Panel

Fire. DF6000 Control Panel. User Manual. Assessed to: ISO 9001:2000 Certification number: 714h/01

Conventional Fire Alarm System 2014 V1.2

MINERVA MZX125. Digital Addressable Fire Detection System

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Analogue addressable devices

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

LF-4000 Series Conventional Fire Alarm Control Unit

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Installation, Commissioning & Operating Manual

CONTENTS NBM-06 Bell (6") Page 1

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Intelligent addressable fire alarm control panel

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Opal TM AV Devices. Data Sheet. Benefits

Series 65 Product Guide MAN 3036

Wireless Fire & Security Solutions. Fire Product Showcase

Evolution Analogue Addressable Fire System

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

DF6000 INSTALLATION MANUAL. Document Drg Ref PR CPR F1141. Assessed to ISO 9001:2008 Certification number 714w/01

Conventional Leaflets

Fire detection and alarm system Installation instructions

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

CF3000 INSTALLATION MANUAL. Document Drg Ref PR CPR F1140. Assessed to ISO 9001:2008 Certification number 714w/01

An introduction to... Sigma

good things in small packages

Precept Marine Control Panel Application Guide

AP200 SERIES INTELLIGENT ALARM DEVICES

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Specification/ Data Sheet

CONVENTIONAL AUDIBLE VISUAL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Our technology, your peace-of-mind. Product list

Evacuate everyone Sonos Pulse & Nexus Pulse

Intelligent Single Loop Fire Alarm Control Panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

FEC400 Series. Installation Manual

EN54-23 Beacons & Sounder Beacons

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

UL Systems. UL intelligent addressable systems Product Name

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

EMERGENCY LIGHTING SYSTEM

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

Intelligent Security & Fire Ltd

Accessible Toilet Alarm

Industrial Signalling

Transcription:

4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional detectors, sounders and EN54-23 approved beacons all share the same zone wiring. This delivers significant savings in both cable and installation costs without sacrificing the systems capability. Supporting up to 52 devices per zone, all panels in the range have the facility to flash detector LED s to facilitate the location of any wiring faults. Features Choice of 2, 4 and 8 zone control panels Detectors and sounders share the same wiring One man test facility Class change input Interlink relay functionality for connecting 2 BiWire Ultra panels together Supports an expansion card for Fire Routing Equipment, Fire Protection Equipment and fire relays per zone. Modern and discreet enclosure Benefits EFBW2ZONE EFBW4ZONE EFBW8ZONE No. of zones 2 4 8 Detectors per zone Maximum loading per zone 32 32 32 200mA 200mA 200mA Repeater Port Tailored to the size and need of the building Reduced cost of installation Simple system testing by a single fire alarm technician Capability to sound class change bell in schools Interlink relay allows for greater system flexibility Comprehensive protection for safety of building occupants

4.2 Control panels and repeater panels Technical specification Dimensions EFBW2ZONE EFBW4ZONE EFBW8ZONE Description 2 zone panel 4 zone panel 8 zone panel Specification Number of Zones 2 4 8 Devices Per Zone Max of 32 Detectors and Manual Callpoints, Zone loading cannot exceed 200mA in alarm Maximum Loading Per Zone Standby Zone Voltage Alarm Zone Voltage Fuse Protection Per Zone End of Line Termination Fire, Fault & Interlink Relay 200mA Min: 22V DC, Max: 24V DC Min: 31V DC, Max: 33V DC 250mA PTC Standard panel connections EOLM-3 Only (Do not use EOLM-1 or EOLM-2) Type: Volt-Free, Single Pole Double Throw, Rating: 30V DC, 1A, Fuse 1.1A PTC Auxiliary Output V: 0V DC (Standby)/30V DC (Alarm +/-10%), Imax: 50mA, Fuse: 50mA PTC Class Change Short circuit to trigger input, open circuit to clear input Mains rating 230V Ah +10%/-15% 50Hz Battery rating 2 x 12V 5Ah Changeable power fuses Repeater Port Yes Environmental Operating temperature Relative humidity IP Rating Physical Weight (excluding batteries) Material Cabling Cable access Cable type Mains 1A anti surge Battery 6-3A anti surge -5 C to +40 C 93% +/-3% non-condensing IP30 2.25kg PC ABS Front and Rear 29 x 20mm drill positions Slots for rear cable entry Firetuf FT120 / FP200 2 core 1.5mm, 2 screened fire rated cable, 500m (max per zone) Description Height (mm) Width (mm) Depth (mm) Complete Panel 336 375 134 Backbox 273 338 88 Status indication 1. When the fire panel enters a fault condition it will turn on the General Fault indicator and the appropriate fault indicator (refer to 8 for more details). The panel buzzer will sound a slow pulsing tone. 2. System Fault Severe failure of the panel, the service company must be contacted immediately. Repeater Fault Communication with a repeater panel has been lost 3. Battery Fault Battery voltage missing Mains Fault Mains supply missing 4. Battery Failure Battery impedance failure Charger Fault Charger voltage missing 5. Sounder Fault Short circuit or open circuit condition detected on the zone will prevent the activation of sounders if fitted on that zone 6. FRE Fault Short circuit or open circuit condition detected on the FRE output 7. FPE Fault Short circuit or open circuit condition detected on the FPE output 8. Detector Removed Fault A detector head has been removed Zone Fault Short circuit or open circuit condition detected on the zone. Catalogue numbers Description Eaton 2 zone BiWire Ultra panel EFBW2ZONE Eaton 4 zone BiWire Ultra panel EFBW4ZONE Eaton 8 zone BiWire Ultra panel EFBW8ZONE BiWire End of line module BWEOLM 2 zone relays + FRE/FPE BW0B2Z 4 zone relays + FRE/FPE BW0B4Z 8 zone relays + FRE/FPE BW0B4Z

EFBW5IN1DET - BiWire Ultra detector 5 in 1 The BiWire Ultra range offers a multi-mode, 5 in 1 detector, approved to both EN54 parts 5 & 7, which covers many building needs. It s quick and simple to install with a stylish low profile design. The detector is mounted on our standard conventional base (FXN520). Each detector is fitted with a 360 viewable LED for indication. This 5 in 1 detector can be configured to operate as either an optical detector, photo-thermal detector or 1 of 3 heat detector modes (rate of rise and 2 fixed heat models) using the four position switches located at the back of the detector. The EFBW5IN1DET is certified for use in all 5 modes. Features Five modes in one detector Offers a range of sensor types 360 indicator LED using lightpipe technology Positive lock indication Easy to maintain/service Benefits Suitable for a broad range of applications Wide viewing angle for increased LED visibility Quick and simple to install Discreet design for incorporation into any decor

Technical specification Dimensions EFBW5IN1DET Description Detector 5 in 1 Standards EN54 Part 5 & 7 2001 Dia Supply ratings Operating voltage 15V DC to 30V DC Standby current Startup current 30µA (max) 340µA (max) D1 D2 Alarm current 25mA (max) Fixing information Mounting position Ceiling in open areas Mounting options Surface mount with FXN520 base Area coverage 100m² (subject to local standards) System wiring 2 Core Environmental Operating temperature -20ºC to 75ºC (dependent on setting) Humidity (non condensing) 0 to 93% Dia (mm) D1 (mm) D2 (mm) 104 55 42 Physical Construction Colour Dimensions excl base (dia x depth) Dimensions incl base (dia x depth)) Ingress protection EMC Compatibility Suitable for use with PC/ABS White 104mm x 42mm 104mm x 55mm IP40 CE Marked Eaton s BiWire Ultra fire system Performance Feature Optical smoke mode Photothermal mode Rate of rise mode Fixed heat 77 C mode Fixed heat 92 C mode Area coverage 100m 2 100m 2 50m 2 50m 2 50m 2 (subject to local standards) Heat class N/A A2S A1R BS CS Alarm temperature N/A 60 C 60 C 77 C 92 C Installation 1. Detectors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised detector removal without the use of a special tool. 4. Positive click mechanism incorporated to provide clear indication when detector is correctly located in base. User interface 1. Red LED to indicate alarm condition. 2. Amber LED to indicate chamber fault/drift compensation limit. 3. All wiring connections are via a common mounting base (supplied separately). Catalogue numbers Description Detector 5 in 1 Standard base EFBW5IN1DET FXN520

EF5021BW range - BiWire Ultra base sounder & base sounder VAD The BiWire Ultra base sounder and base sounder VAD can be used both with a detector or as a stand alone device. The base sounder and base sounder VAD are certified to EN54-3 and EN54-23 respectively. The base sounder and base sounder VAD both incorporate a detector mounting base allowing a detector to be fitted directly to the base, or alternatively a cover plate can be used to provide a dedicated, discreet stand alone device. Features Available in both sounder only and sounder VAD Certified to EN54-3 & EN54-23 Cover plate (optional) Benefits Offers a compact design and reduces time of installation of the base with the detector Easy to maintain and service Standalone base sounder or base sounder VAD offers the flexibility of use with or without the detector

Technical specification Dimensions EF5021BWS / EF5021BWSB Supply Voltage (Alarm) 25.5~35 Vdc Supply Voltage (Standby) 18~25.5 Vdc Cable Size/type 0.5~2.5mm / FIRETUF, FP200 or MICC Standby Current (BiWire Mode) <15μA Current (High Volume) Sdr Only = 4.7mA, AV = 11mA Current (Low Volume) Sdr Only = 2.6mA, AV = 8.7mA Sound Output (High Volume) 90 +/- 3dB(A) Sound Output (Low Volume) 80 +/- 3dB(A) Operating Temperature -10 to +55ºC (93% ± 3%RH) Material ABS / PC FR Plastic Environmental Category IP21C Tones 3 Flash Rate 0.5Hz (Not applicable to EF5021BWS) Flash On Period 60ms (Not applicable to EF5021BWS) Dia D Dia (mm) D (mm) 115 44 Installation Standard connections 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only) 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Cables pass through aperture in sounder body and terminate at the front. 6. Connections are to connector block on front of main sounder body. System functionality 1. Volume and tone are set by control panel, no need to access sounder to alter setting. 2. Soft addressed. Compatible Conventional Control Panelsl -ZONE + + VE - VE 2 1 + LED 3 E 4 remote indicator (optional) 2 1 LED 3 E 4 EOLM-1 end of line monitor device Catalogue numbers Description BiWire Ultra base sounder BiWire Ultra base sounder VAD Cover Plate (Pack of 5) EF5021BWS EF5021BWSB CASC

EF009, EF009SB - BiWire Ultra wall sounder & wall sounder VAD The BiWire Ultra wall sounder and wall sounder VAD offer low current consumption and high sound output. The BiWire Ultra range of sounders has been designed to meet the latest European Standards - EN54-3 and EN54-23. It is offered in two variants, sounder only or a combined sounder VAD. Features Ultra low current consumption Certified to EN54-3 and EN54-23 High sound output Weatherproof option Benefits Maximises number of devices on a system Certified for Fire use Ideal for large installations Easy to maintain and service

Technical specification EF009SB / EF009SBWP & EF009 / EF009WP Supply Voltage (BiWire Alarm) 25.5~35 Vdc Supply Voltage (BiWire Standby) 18~25.5 Vdc Supply Voltage (Conventional) 18~35 Vdc Cable Size/type 0.5~2.5mm / FIRETUF, FP200 or MICC Standby Current (BiWire Mode) <15μA Current (High Volume) Sdr Only = 4.8mA, AV = 11mA Current (Low Volume) Sdr Only = 2.6mA, AV = 8.7mA Sound Output (High Volume) 99 +/- 3dB(A) Sound Output (Low Volume) 89 +/- 3dB(A) Operating Temperature -25 to +70ºC (95%RH) Material ABS FR Plastic Environmental Category EF009SB: IP21C EF009SBWP: IP66 Tones 3 Flash Rate 0.5Hz (Not applicable to EF009(WP)) Flash On Period 60ms (Not applicable to EF009(WP)) Installation Dimensions 1. First fix mounting plate is fixed to wall. 2. Cable entry is from rear, or top/bottom. 3. Connections are to main sounder body. 4. Separate alarm line in and alarm line out terminals are provided. D H Interface options Sounder operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Standard connections W Description H (mm) W (mm) D (mm) EF009 / EF009SB 106 106 91 EF009WP / EF009SBWP 110 110 100 + + - - Compatible Conventional Control Panel WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable. Catalogue numbers Description BiWire Ultra wall sounder BiWire Ultra wall sounder, weatherproof BiWire Ultra wall sounder VAD BiWire Ultra wall sounder VAD, weatherproof EF009 EF009WP EF009SB EF009SBWP

EF201BWCP, EF203BWCPWP - BiWire Ultra callpoints Two versions of the BiWire Ultra callpoints are available in this range, the EF201BWCP which can be either surface or flush mounted and the EF203BWCPWP which is a weatherproof version. Both the EF201BWCP and the EF203BWCPWP are compatible with the Eaton s BiWire Ultra range of fire systems. These callpoints are designed for fast and simple installation and are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories is available to maximise the functionality of the callpoint for particular applications. Features Fast fit clip on front cover Wide range of accessories Heavy duty terminals Two models available: - Internal - Weatherproof (IP65) Single tool for test and access Robust construction Benefits Quick and simple to install Easy to maintain and service Versatile installation Weatherproof variant suitable for outside use

Technical specification Supply Voltage Cable Size/type Standby Current Alarm Current Low Level Alarm Current Operating Temperature (EF201BWCP) Operating Temperature (EF203BWCPWP) Material Environmental Category LED Indicator EF201BWCP / EF203BWCPWP 18~35 Vdc 0.28mm² ~ 2.5mm² Cable shall comply with applicable standard <22μA 20mA 1mA -10 to +55ºC (95%RH) -25 to +70ºC (95%RH) ABS FR Plastic EF201BWCP: IP21C EF203BWCPWP: IP66 Red Dimensions W Standard connections COMMON 680Ω H + + - - Compatible Conventional Control Panel D Description H (mm) W (mm) D (mm) Flush mounted 87 87 36 Surface mounted 87 87 57 Weatherproof 87 87 59 WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate zone in and zone out terminals are provided for all connections. 7. Surface/flush callpoints are IP21C, weatherproof is IP66. User interface 1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element. Catalogue numbers Description Callpoint, surface/flush Callpoint, weatherproof Protective hinged cover Spacer plates (pack of 10) Recessing bezels (pack of 10) Resettable element kit (pack of 10) Spare break glasses (pack of 5) Callpoint keys (pack of 10) EF201BWCP EF203BWCPWP CXPC MBGSP MBGBEZ MBGREKIT FX5G MFBGKEY3