02PN8 HI-PE/CF --- Rev. F044GB60K10 1 METAL DETECTOR HI-PE Additional information for the HI-PE/CF Series ATTENTION! Keep the transducer matched with the electronics unit and the Technical Booklet which have the same serial number. Program Version: N86V634x Rev.: F/044GB60K10 Date 15 / 11 / 1999
2 02PN8 HI-PE/CF --- Rev. F044GB60K10 Contents CONTENTS...2 I - DESCRIPTION...3 DOCUMENT CONTENTS...3 SPECIAL FEATURES OF THE HI-PE/CF SERIES...3 CONSTRUCTION OF THE METAL DETECTOR...4 Electronics Unit...4 Antenna...4 II - INSTALLATION...5 ASSEMBLY...5 Mechanical assembly...5 Fixing the antenna in a cabin: column orientation...5 III ISTRUCTIONS FOR USE...6 SWITCHING ON THE METAL DETECTOR...6 IV - PROGRAMMING...7 Characteristics...7 New programming parameters, or those only present on some standard models...7 ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND "IS"...8 V - TECHNICAL CHARACTERISTICS...9 VI - MAINTENANCE...10 SPARE PARTS...10 HI-PE/CF-AS-140...10 Accessories...10 DECLARATION OF CE CONFORMITY...11 CEIA reserves the right to make changes, at any moment and without prior notice, to the models (including programming), their accessories and optionals, to the prices and conditions of sale.
02PN8 HI-PE/CF --- Rev. F044GB60K10 3 I - DESCRIPTION Document contents Externally, CEIA HI-PE/CF Series metal detectors appear identical to standard HI-PE models, and only differ in having some modifications to the antenna and to the programming parameters. This document illustrates these specific modifications, and we would refer users to the manual included with all models for more general information. Special features of the HI-PE/CF Series The transit of metal personal effects in common daily use through Metal Detector checkpoints generates signals which often exceed those of some types of fire-arm available on the market. Discrimination of the these by the Metal Detector therefore becomes a necessary condition for establishing access systems with high flow rates. As a solution to this problem, CEIA presents its new HI-PE/CF Metal Detector which, with its detection functions based on an innovative signal analysis system, raises the threshold of discrimination between medium-sized fire-arms and personal effects to a level up to 400% above that of the 02PN8 HI-PE model. The advantages of using this new Metal Detector are the following: a notable reduction in the need for branch staff to act to check inward- and outward-bound traffic; increase in convenience of access to the bank for customers; and, not least, the opportunity to increase the level of security. Statistical data obtained in real operating situations with the HI-PE/CF Metal Detector have demonstrated the almost total elimination of false alarms compared with earlier systems, at the same level of detection capability relating to fire-arms of conventional construction and in light metal, such as the Beretta 6.35mm. The HI-PE/CF Metal Detector keeps the same dimensions and programming characteristics as the 02PN8 HI- PE Metal Detector, so that it can be fitted into systems which were designed for the earlier model. As far as its application is concerned, the parameters already in use for walk-through Metal Detectors remain valid, in particular the importance of the electromagnetic compatibility of the metal structure. In order to guarantee the levels of performance described above, use of this new Metal Detector is restricted to cabins previously certified for electromagnetic compatibility with the HI-PE/CF Metal Detector.
4 02PN8 HI-PE/CF --- Rev. F044GB60K10 Construction of the Metal Detector Electronics Unit The HI-PE/CF electronics unit differs externally from the standard version only in the model logo. Fig. I-1: HI-PE/CF electronics unit Antenna The following table illustrates the special features of the HI-PE/CF antenna models: Model Modifications HI-PE/CFPNAS600 Corresponds to model HI-PE/PN-AS-600. Useful passage width: 680-820mm HI-PE/CF No external modification compared with version HI-PE/CN-AS-140. Useful passage width limited to 740mm (widened passage width version HI-PE/CN-AS-140L not available). HI-PE/CF-EN Corresponds to model HI-PE Elliptic. No external modification HI-PE/CF-EW (waterproof) Corresponds to model HI-PE Elliptic waterproof. No external modification Fig. I-2a: 02PN8 HI-PE/CF-AS Fig. I-2ba: 02PN8 HI-PE/CF-EN Fig. I-2c: 02PN8 HI-PE/CF-PN-AS-600
02PN8 HI-PE/CF --- Rev. F044GB60K10 5 II - INSTALLATION Assembly Mechanical assembly Fixing the antenna in a cabin: column orientation Installation of the antenna in a metal cabin generally requires a test by qualified CEIA technicians. As a result of the test, the installer is provided with any technical notes needed for installation, including instructions on how to orientate the antenna when attaching it to the base structure. Orientation of the columns is achieved by referring to the two coloured markings C to be found near the electronics unit connecting cable. C C Fig II-1a Example of column antenna arrangement, with markings C facing each other C C Fig II-1b - Example of column antenna arrangement, with markings C not aligned
6 02PN8 HI-PE/CF --- Rev. F044GB60K10 Switching on the Metal Detector III ISTRUCTIONS FOR USE After turning ON the equipment, an audible signal will sound and the display of the electronics unit will show the following information: CEIA MANUFACTURER HIPE CF MODEL ALARM INDICATION TEST - - - - WAIT INITIAL ADJUSTMENT PHASE NORMAL OPERATION Fig. III 1
02PN8 HI-PE/CF --- Rev. F044GB60K10 7 IV - PROGRAMMING Characteristics Programming parameters not applicable New programming parameters, or those only present on some standard models Modified programming parameters New functions, or those only present on some standard models SS, G1, G2, TP, CS, AU, FQ CM, RO, TI IS Direct display of the level of security IS New programming parameters, or those only present on some standard models Code Meaning Possible Type Notes values Cabin model 0-4 C/R Siting of an HI-PE/CF antenna inside a metal structure generally requires a test CM to be carried out by CEIA technicians. For installation to be possible in cabins with different characteristics, these tests must be carried out on a sample unit of each type. CEIA stores the optimum configuration of the device for each cabin which has been tested. The CM command allows the installer to select the configuration according to the cabin used. The correspondence between the numerical values of the CM setting and the type of cabin is specified in the CEIA test report, which also specifies the string of characters which appears on the display during selection as a concise denomination of the type of cabin. The 0 setting is usually reserved for the openspace configuration without surrounding metal structure. E.g. : Message FREE680 CABINA 1 Numerical Comment value 0 Metal detector without surrounding metal structure, useful passage width 680mm (model HI- PE/CF-AS-140 1 Metal detector installed in a cabin of the 1 st type CABINA 2 2 Metal detector installed in a cabin of the 2 nd type CABINA 3 3 Metal detector installed in a cabin of the 3 rd type VOID future 4 Free memory, usable for a new configuration in the RO Read out of the reception signal 0-9995 R This displays the result of the processing of the reception signals, by means of a numerical indication. It can display values from 0 to 9,995.
8 02PN8 HI-PE/CF --- Rev. F044GB60K10 Code Meaning Possible values IS TI International Security Standard Transmitter inhibitor see the followin g table NO, YES Type C,R Notes Display indication: When the value is under the alarm threshold, the indication is green, when the value is above the alarm threshold, the indication is red. Deactivates the transmitter if the Metal Detector is inhibited. The Metal Detector behaves as follows in the two different situations: TI=NO the metal detector is immediately operational when the inhibition signal is switched off TI=YES when the inhibition signal is switched off, the Metal Detector resets; in this case, it is necessary to wait a few moments (0.5 2 sec) before the Metal Detector is operational (tr in the diagram below) inhibition signal inhibition TX TX inactive alarm relay reset normal operation tr 0,5-2s Fig. IV-1 Delay before the metal detector is operational with TI=ON: after deactivation of the inhibition signal, it is necessary to wait for time tr before the detector reactivates ANALYSIS PROGRAMS AVAILABLE WITH THE COMMAND "IS" PROGRAM IS DISPLAY SECURITY LEVEL / APPLICATION SAMPLES MESSAGE* 1 NIL.1 Standard : NILECJ-STD-0601.00 Security Level 1 AM9 2 NIL.2BA Standard : NILECJ-STD-0601.00 Security Level 2 AM7 Basic specifications 3 NIL.3BA Standard : NILECJ-STD-0601.00 Security Level 3 AM5 Basic specifications 4 NIL.2AD Standard : NILECJ-STD-0601.00 Security Level 2 AM7; AN7 Additional specifications 5 NIL.3AD Standard : NILECJ-STD-0601.00 Security Level 3 Additional specifications AM5; AN5 6 HIGH IMM Level with high immunity to environmental - interference (corresponding approximately to level NILECJ 2, with additional specifications). * The display message also appears when not in programming if the key is pressed. ; The unit is programmed in the factory to ensure operation according to the IS standards for the passage width listed in the "Hardware and software configuration sheet" included at the end of the manual. If, for any reason, the passage width has been changed, this correspondence is not guaranteed.
02PN8 HI-PE/CF --- Rev. F044GB60K10 9 V - Technical characteristics Main characteristics Adjustable sensitivity with wide range of settings. International standards: Direct selection of International Security Standards. Extremely high discrimination. Extremely high immunity to both mechanical and electromagnetic interference. Programmable operation controlled by microprocessor. Programming: via incorporated keypad and display or via RS232/RS485 serial link from a personal computer or computer network. Access to programming protected by mechanical lock and two alphanumeric passwords. Automatic, cable-free synchronisation between two or more metal detectors, at a minimum distance of 5cm from each other. Highly integrated, highly reliable professional electronics. Electronics control unit separate from the detector. No initial or periodic calibration. Easy maintenance. The electronics unit can be replaced in less than one minute. Colour: light grey, RAL 7040 Alarms Audible signal: Buzzer - 90 dba (1 m). Relay output: Switch contact NA, NC, C - 1 A - 24 Vdc. Reset: PP input, automatic or manual, N.C. contact. Inhibition: INI input, N.A. contact. Self-diagnosis: Incorporated, with intermittent audible signal. Certification and compliance Harmless to wearers of pacemakers, life-support systems, pregnant women and magnetic media (floppy disks, audio-cassettes, video-cassettes and similar). Complies with NILECJ-0601-00 standards for all security levels. Complies with EC regulations and international standards on electrical safety and electromagnetic compatibility (EMC). Installation data power supply: 20 30 Vdc, 25VA max. Inputs: RS-232C interface for connection to a terminal, computer or external modem; RS-232C interface for connection to other CEIA Metal Detectors. Temperature and relative humidity: from -15 C to +70 C; from 0 to 95% (without condensation) Dimensions and weight of the electronics unit: 380 x 157 x 82 mm / 1.2 kg. Accessories / Options Metal test samples.
10 02PN8 HI-PE/CF --- Rev. F044GB60K10 VI - MAINTENANCE Spare parts HI-PE/CF-AS-140 Validity: revision 1.0, 17/07/1999 Replacement parts Description Quantity Code Electronics unit IP20 1 18292 Electronics unit card 06012SCD60 1 18754 Connector cap 1 12521 Column RX N076 1 18290 Column TX N076 1 18291 Complete electronics unit container 1 19045 Cover complete with lock 1 4074 Electronics unit key kit 1 8471 In all component orders please indicate the serial number of the device Accessories Validity: revision 1.0, 9/11/1999 Replacement parts Description Quantity Code European mains power supply unit 1 19208 USA mains power supply unit 1 19825 MDScope 1 17469 Nilecj Std 0601.00 level 1 samples 1 3501 Nilecj Std 0601.00 level 2 samples 1 3497 Nilecj Std 0601.00 level 3 samples 1 3498 In all component orders please indicate the serial number of the device
02PN8 HI-PE/CF --- Rev. F044GB60K10 11 DECLARATION OF CE CONFORMITY DECLARATION OF CONFORMITY CE DECLARATION DE CONFORMITE CE KONFORMITÄTSERKLÄRUNG CE DECLARACION DE CONFORMIDAD CE DICHIARAZIONE DI CONFORMITÁ CE Manufacturer Fabricant / Herstellers / Fabricante / Costruttore: CEIA S.p.A. Strada Provinciale di Pescaiola 54/G 52040 Viciomaggio - Arezzo - ITALY Declares that the product déclare que ce produit / erklärt, daß das Produkt / declara que el producto / dichiara che il prodotto: Product name: Nom du produit: / Produktname: Nombre del producto: / Nome: Model Série / Serie / Serie / Modello: Metal Detector Détecteur de Métaux / Elektronischer Metalldetektor Detectores de metales / Metal Detector Elettronico HI-PE/CF conforms to the following Product Specifications est conforme aux spécifications suivantes / folgenden Produktspezifikationen entspricht / es conforme a las siguientes especificaciones / è conforme alle seguenti specifiche di prodotto: Safety / Sécurité / Sicherheit / Seguridad / Sicurezza: EN 61010-1 - 1 (1993) EMC CISPR 11: 1990 / EN 55011: Group 1 - Class B EN 61000-4-2: 1995 EN 61000-4-3: 1995 EN 61000-4-6: 1995 ENV50204:1994 EN 61000-4-4: 1995 This product complies with the requirements of the Low Voltage Directive 73/23/EEC and following modifications indicated in the 93/68/EEC Directive. Le produit ci-dessus répond aux exigences de la Directive 73/23/CEE et aux modifications suivantes mentionnées dans la Directive 93/68/CEE concernant la basse tensions. Dieses Produkt entspricht den Anforderungen an Niederspannungsgeräte gemäß der Norm 73/23/EEC und nachfolgender, in der Norm 93/68/EEC angegebener Änderungen. El producto indicado cumple los requisitos de la Low Voltage Directive 73/23/CEE y siguientes modificaciones indicadas en la Directiva 93/68/EEC. Il prodotto è conforme alle norme della direttiva 73/23/EEC e successive modifiche indicate nella direttiva 93/68/EEC sulla bassa tensione. This product complies with the requirements of the EMC Directive 89/336/EEC and following modifications indicated in the 93/68/EEC Directive. Le produit ci-dessus répond aux exigences de la Directive 89/336/CEE et aux modifications suivantes mentionnées dans la Directive 93/68/CEE concernant les interférences électromagnétiques. Dieses Produkt entspricht den Anforderungen der EMC-Norm 89/336/EEC und nachfolgender, in der Norm 93/68/EEC angegebener Änderungen. El producto indicado cumple los requisitos de la Directiva EMC 89/336/CEE y siguientes modificaciones indicadas en la Directiva 93/68/EEC. Il prodotto è conforme alle norme della direttiva EMC 89/336/EEC e successive modifiche indicate nella direttiva 93/68/EEC. Arezzo, 1997 / 11 / 15 SpA Person in charge Lab. EMC Resp. Laboratoire EMC / Laborattaché EMC Resp. Laboratorio EMC / Resp. Lab. EMC Ing. E. Sorini