IMAX XTRA EL. 320kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single or multiple installations this single engine boiler offers improved installation times over dual engine units. FEATURES AND BENEFITS 2 year parts and labour warranty Simple control interface with large backlit display NOx <40mg/kWh Volt free contacts Natural Gas 0-10v BMS operation standard ErP compliant (320-395kW) Robust aluminium silicon alloy heat exchanger Suitable for single or multiple installations Building Regulation Part L2 compliant (470-620kW) Up to 109.8% part load efficiency DIMENSIONS AND CLEARANCES BOILER DIM A DIM B DIM C 320kW 835 1485 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE L SIDE REAR** FRONT B C A For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm ** This clearance dimension applies independently of the installed flue system IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 320kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 417 Boiler Dimensions mm 1485 (H) x 835 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 150 Right Side: 700 Top: 700 Rear: 150** Seasonal Efficiency (Building Regs L2) Gross % 96.8 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 32.2 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 58.9-298.4 Boiler Output (Mean 40 C) kw 66.7-323.1 Boiler Input (Gross cv) kw 338.3 Gas Inlet Size G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 25 Hydraulic Resistance (20 C T) mbar 98 Nominal Flow Rate (11 C T) l/s 6.9 Nominal Flow Rate (20 C T) l/s 3.8 Min Flow Rate (20 C T) (MAX MOD) l/s 0.76 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size G3 Water Content litres 47.3 FLUE/AIR INLET Flue Size mm 250 Flue Gas Volume m³/h 472.6 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2.65 Power Consumption Watt 610 Modulating Input V/dc 0-10V Fuse Rating Amp 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Pump Kits Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. ** This clearance dimension applies independently of the installed flue system GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211173
IMAX XTRA EL. 395kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single or multiple installations this single engine boiler offers improved installation times over dual engine units. FEATURES AND BENEFITS 2 year parts and labour warranty Simple control interface with large backlit display NOx <40mg/kWh Volt free contacts Natural Gas 0-10v BMS operation standard ErP compliant (320-395kW) Robust aluminium silicon alloy heat exchanger Suitable for single or multiple installations Building Regulation Part L2 compliant (470-620kW) Up to 109.8% part load efficiency DIMENSIONS AND CLEARANCES BOILER DIM A DIM B DIM C 395kW 835 1485 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE L SIDE REAR** FRONT B C A For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm ** This clearance dimension applies independently of the installed flue system IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 395kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 451 Boiler Dimensions mm 1485 (H) x 835 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 150 Right Side: 700 Top: 700 Rear: 150** Seasonal Efficiency (Building Regs L2) Gross % 96.8 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 40.8 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 72.6-368.3 Boiler Output (Mean 40 C) kw 80.5-399.5 Boiler Input (Gross cv) kw 417.5 Gas Inlet Size G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 25 Hydraulic Resistance (20 C T) mbar 96 Nominal Flow Rate (11 C T) l/s 8.6 Nominal Flow Rate (20 C T) l/s 4.7 Min Flow Rate (20 C T) (MAX MOD) l/s 0.94 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size G3 Water Content litres 53.3 FLUE/AIR INLET Flue Size mm 250 Flue Gas Volume m³/h 583.3 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2.57 Power Consumption Watt 592 Modulating Input V/dc 0-10V Fuse Rating Amp 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Pump Kits Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. ** This clearance dimension applies independently of the installed flue system GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211174
IMAX XTRA EL. 470kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single or multiple installations this single engine boiler offers improved installation times over dual engine units. FEATURES AND BENEFITS 2 year parts and labour warranty Simple control interface with large backlit display NOx <40mg/kWh Volt free contacts Natural Gas 0-10v BMS operation standard ErP compliant (320-395kW) Robust aluminium silicon alloy heat exchanger Suitable for single or multiple installations Building Regulation Part L2 compliant (470-620kW) Up to 109.8% part load efficiency DIMENSIONS AND CLEARANCES BOILER DIM A DIM B DIM C 470kW 835 1485 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE L SIDE REAR** FRONT B C A For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm ** This clearance dimension applies independently of the installed flue system IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 470kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 479 Boiler Dimensions mm 1485 (H) x 835 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 150 Right Side: 700 Top: 700 Rear: 150** Seasonal Efficiency (Building Regs L2) Gross % 96.9 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 47.4 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 85.2-438.6 Boiler Output (Mean 40 C) kw 95.6-475.8 Boiler Input (Gross cv) kw 496.8 Gas Inlet Size G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 24 Hydraulic Resistance (20 C T) mbar 94 Nominal Flow Rate (11 C T) l/s 10.2 Nominal Flow Rate (20 C T) l/s 5.6 Min Flow Rate (20 C T) (MAX MOD) l/s 1.12 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size G3 Water Content litres 59.3 FLUE/AIR INLET Flue Size mm 250 Flue Gas Volume m³/h 694.0 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2.91 Power Consumption Watt 670 Modulating Input V/dc 0-10V Fuse Rating Amp 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Pump Kits Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. ** This clearance dimension applies independently of the installed flue system GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211175
IMAX XTRA EL. 545kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single or multiple installations this single engine boiler offers improved installation times over dual engine units. FEATURES AND BENEFITS 2 year parts and labour warranty Simple control interface with large backlit display NOx <40mg/kWh Volt free contacts Natural Gas 0-10v BMS operation standard ErP compliant (320-395kW) Robust aluminium silicon alloy heat exchanger Suitable for single or multiple installations Building Regulation Part L2 compliant (470-620kW) Up to 109.8% part load efficiency DIMENSIONS AND CLEARANCES BOILER DIM A DIM B DIM C 545kW 835 1485 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE L SIDE REAR** FRONT B C A For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm ** This clearance dimension applies independently of the installed flue system IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 545kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 507 Boiler Dimensions mm 1485 (H) x 835 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 150 Right Side: 700 Top: 700 Rear: 150** Seasonal Efficiency (Building Regs L2) Gross % 96.9 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 57.3 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 100.7-508.6 Boiler Output (Mean 40 C) kw 113.0-552.7 Boiler Input (Gross cv) kw 576.0 Gas Inlet Size G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 24 Hydraulic Resistance (20 C T) mbar 93 Nominal Flow Rate (11 C T) l/s 11.8 Nominal Flow Rate (20 C T) l/s 6.5 Min Flow Rate (20 C T) (MAX MOD) l/s 1.3 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size G3 Water Content litres 65.3 FLUE/AIR INLET Flue Size mm 250 Flue Gas Volume m³/h 804.7 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 2.71 Power Consumption Watt 625 Modulating Input V/dc 0-10V Fuse Rating Amp 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Pump Kits Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. ** This clearance dimension applies independently of the installed flue system GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211176
IMAX XTRA EL. 620kW FLOOR STANDING CONDENSING The Imax Xtra EL range of condensing boilers is available in 5 models with outputs from 320 to 620kW. Suitable for floor standing applications in either single or multiple installations this single engine boiler offers improved installation times over dual engine units. FEATURES AND BENEFITS 2 year parts and labour warranty Simple control interface with large backlit display NOx <40mg/kWh Volt free contacts Natural Gas 0-10v BMS operation standard ErP compliant (320-395kW) Robust aluminium silicon alloy heat exchanger Suitable for single or multiple installations Building Regulation Part L2 compliant (470-620kW) Up to 109.8% part load efficiency DIMENSIONS AND CLEARANCES BOILER DIM A DIM B DIM C 620kW 835 1485 1685 The following minimum clearances must be maintained for operation and servicing: TOP R SIDE L SIDE REAR** FRONT B C A For full details of all configurations & specifications, please refer to the Imax Xtra EL installation manual. All dimensions in mm ** This clearance dimension applies independently of the installed flue system IDEAL COMMERCIAL BOILERS PO Box 103, National Avenue Kingston upon Hull, East Yorkshire, HU5 4JN F: 0844 5436181 IDEALCOMMERCIALBOILERS.COM
IMAX XTRA EL 620kW TECHNICAL SPECIFICATIONS. GENERAL Dry Weight kg 528 Boiler Dimensions mm 1485 (H) x 835 (W) x 1685 (D) Boiler Clearances mm Front: 700 Left Side: 150 Right Side: 700 Top: 700 Rear: 150** Seasonal Efficiency (Building Regs L2) Gross % 97 Min/Max Gas pressure (Nat Gas) mbar 15-20 BURNER PRE MIX Fuel (Type G20) Natural Gas Fuel Consumption (Nat Gas) m³/h 62.2 Flame Protection Ionisation Ignition Spark Boiler Output (Mean 70 C) kw 114.9-578.2 Boiler Output (Mean 40 C) kw 127.6-628.9 Boiler Input (Gross cv) kw 654.8 Gas Inlet Size G2 NOx Rating/emissions at 0% O mg/kwh Class 6 (<40) HYDRAULICS Hydraulic Resistance (11 C T) mbar 24 Hydraulic Resistance (20 C T) mbar 92 Nominal Flow Rate (11 C T) l/s 13.5 Nominal Flow Rate (20 C T) l/s 7.4 Min Flow Rate (20 C T) (MAX MOD) l/s 1.48 Min Flow Temperature C 30 Max Flow Temperature C 90 Min Working Pressure bar 1 Max Working Pressure bar 6 Max Static Head Of Water metres 61 Condensate Connection mm 21.5 High Limit Set Point C 100 flow, 100 return 105 H/Ex Flow & Return Size G3 Water Content litres 75.3 FLUE/AIR INLET Flue Size mm 250 Flue Gas Volume m³/h 914.8 Min-Max Flue Gas Temperature 80/60 C 50-63 Max Flue Resistance Pa 100 ELECTRICAL Electrical Supply 230/240V 50Hz 1 Ph Current (Max No Pump) Amp 3.35 Power Consumption Watt 770 Modulating Input V/dc 0-10V Fuse Rating Amp 7 Controls Voltage V 24 or 240 Insulation Class IP IP20 CONTROL OPERATION On/Off 0-10V DC OpenTherm High Limit Protection Low Water Protection Volt Free Common Alarm Boiler Run Indication OPTIONAL EXTRAS Modulating Sequencer Kit, including DHW Tank Kit, Plant Room Sensor Kit, 6 Zone Expansion Kit Programmable Room Thermostat Kits Outside Sensor Kit DHW Tank Sensor Kit Safety Interlock Kit BACNet Gateway Kit LONWorks Gateway Kit MODBus Gateway Kit Remote Access Kit Pump Kits Sealed System Services Flow Manifold Kit Inlet Air Filter Kit Condensate Pump Kit Room Sealed Air Duct Kit FLOOR STANDING NOx CLASS 6 BIM *2 year warranty subject to Terms and Conditions. 2 year parts and labour warranty available when registered within 30 days of installation. ** This clearance dimension applies independently of the installed flue system GET A QUOTE. W: IDEALCOMMERCIALBOILERS.COM Please note that the above information is correct at time of publication. Ideal Commercial Heating Limited has a policy of continuous development and therefore reserves the right to alter specifications without prior notification. 211177