COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz

Similar documents
COOLING ONLY HEAT PUMP

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of

PCV1217. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCVAU0828B WATER COOLED INVERTER SERIES. HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to

Single outdoor unit series suitable for homes, offices, shops, and middle-sized buildings

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

OOL ING ONL Y HE AT P UM P PCV0612C. C ooling Only 50 Hz/60 Hz. Heat P ump 50 Hz/60 Hz

VRVIV-0117-E. Cooling Only 50 Hz

FOR REPLACEMENT USE PCV1213. Cooling Only 50 Hz

VRV systems. Superior heating under low temperature conditions

W SERIES. PCVMT1603aprv WATER COOLED SYSTEM. Cooling Only 50 Hz

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

PCV0320. Quieter, Smaller, Sleeker, Simpler: The is now four times better. Even earth friendly with a higher COP.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Inverter Wall Mounted

Inverter Wall Mounted

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

PVVVN1325aprv. PCVAU1327 Preview. Cooling Only / Heat Pump 50 Hz

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

PCR0709A. Options. Indoor unit

DAIKIN Modular Inverter Air Cooled Chiller

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

Inverter Wall Mounted

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

The Comfort and Luxury You Deserve

FBQ. DC Duct Heat Pump or Cooling Only

LV Series. SEER 15+ Concealed Built in Heat Pump

Quick & High Quality replacement

The Comfort and Luxury You Deserve

Split Type Air Conditioners

Product. ortfolio. Integrated climate control

FAQ. Wall Mount Heat Pump or Cooling Only

VRV IV S-series heat pump

. Creating Maximum Comfort

LV Series. SEER 20+ Wall Mount Heat Pump

Quick & High Quality replacement

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz]

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

SiBE39-402A. Service Manual. R-410A Heat Pump 50Hz

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS PRODUCT PORTFOLIO

Energy-saving operation

Up to SEER 26.1 Wall Mount Heat Pump

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Daikin Inverter Ducted Systems

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

The Multi-talented VRV-S.

R410A RZR-0916-C Authorized dealer: Catalogue No. PCSMY1546 Tel: Tel:

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

EPCE03-06D. The Next Generation of Air Conditioning Systems

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Product. ortfolio. Integrated climate control

PLXSID1605. Warning HEAD OFFICE :

The Comfort and Luxury You Deserve

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU1117

EDUS M. General Information. RXYQ-TYDN 3 phase, 460V, 60Hz. RXYQ-TTJU 3 phase, 208/230V, 60Hz

SiE Service Manual. RXYQ5-48MAY1 R410A Heat Pump 50Hz

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

VRV HEAT RECOVERY

HEATING AND COOLING SOLUTIONS DUCTED HEAT PUMPS PCDUNZ0717

PCH0601 HE A T R E CLA IM V E N T ILA T ION

3 rd Generation of VRV. The professional solution for your professional project

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

Daikin Airconditioning UK Ltd

Heat Pump Air Conditioning Systems

Air conditioners, heating & cooling for shops,restaurants and offices

Concealed ceiling units

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Inventor of the Inverter Digital Inverter System

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517

Air Conditioners Heating & Cooling

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

Air Conditioners Heating & Cooling

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517

INVERTER DUCTED SYSTEMS

FTQ. Daikin Inverter Ducted Heat Pump

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Daikin air conditioners for your home

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioners Heating & Cooling

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Transcription:

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. PCV0612F Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. JMI-0107 Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. JQA-1452 Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management. A special air conditioning system designed for small offices and shops Dealer Specifications, designs and other content appearing in this brochure are current as of August 2012 but subject to change without notice. Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ c All rights reserved 08/12 Y.K. COOLING ONLY Only 50 Hz/60 Hz HEAT PUMP Heat Pump 50 Hz/60 Hz

The ideal air conditioning system for small offices and shops Extending the core 5S concept Space saving, Sufficient capacity, Slim design, Soundreduced operation and Single phase power supply Daikin s VRVIII-S offers added value with the 1E concept Easy installation. With all these features and more, we proudly present the ideal air conditioning system designed for small-sized buildings. Slim, compact and sufficient capacity The VRVIII-S is highly space saving, featuring slim and compact outdoor units. It is suitable for small offices and shops with capacities of 4, 5 and 6 HP. Volume Approx. 50% reduction 765 320 The S5S concept Space saving Sufficient capacity Slim design Sound-reduced operation Single phase power supply 5S+1E concepts of Easy installation E 1E concept Contents Footprint 635 VRVIII Approx. 40% reduction 900 (5 HP) (4, 5, 6 HP) VRVIII (5 HP) (4, 5, 6 HP) Outdoor unit can be installed on a balcony The compact, trunk-shaped outdoor unit can easily be installed on a balcony, realising complete system installation within each floor. This enables more useful utilisation of the space on the building rooftop. 1 Introduction... page 1 Main features...page 3 Control systems... page 9 Indoor unit lineup... page 15 Specifications... page 25 Indoor units... page 25 Outdoor units... page 32 Option list... page 33 Indoor units... page 33 Outdoor units...page 35 Control systems...page 35 2

MAIN FEATURES Wide range of choices To suit the variety of rooms found in small offices and shops, the VRVIII-S system offers wide range of indoor and outdoor units. VRVIII-S indoor and outdoor units are almost as easy to install as residential air conditioning systems, making them ideal for small offices and shops. Indoor units 14 types 71 models* A wide range of indoor units includes 71 models in 14 types. The indoor units can be selected to match every room and preference. Outdoor units 3 models Outdoor unit can be selected from three models to provide the power that suits your needs. The trunk-shaped outdoor unit can be neatly installed outside the office. Outdoor unit lineup Model Name Capacity Range Capacity Index RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE 4 HP (11.2 ) 5 HP (14.0 ) 6 HP (15.5 ) 100 125 140 Indoor unit lineup Ceiling Mounted Cassette (Round Flow) Ceiling Mounted Cassette (Compact Multi Flow) Ceiling Mounted Cassette (Double Flow) Ceiling Mounted Cassette Corner Model Name FXFQ-PVE FXZQ-MVE FXCQ-MVE FXKQ-MAVE FXDQ-PBVE (with drain pump) 14 types 71 models* 20 25 32 40 50 63 80 100 125 Capacity Range 0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP Capacity Index 20 25 31.25 40 50 62.5 80 100 125 140 6 HP 140 Slim Ceiling Mounted Duct Ceiling Mounted Duct FXDQ-PBVET (without drain pump) FXDQ-NBVE (with drain pump) FXDQ-NBVET (without drain pump) FXMQ-PVE (700 width type) (900/1,100 width type) Ceiling Suspended FXHQ-MAVE Wall Mounted New FXAQ-PVE New New New New New New Floor Standing FXLQ-MAVE Concealed Floor Standing FXNQ-MAVE Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system. * 13 types and 68 models for 60 Hz specifications. Connection unit series indoor units (50 Hz only) Ceiling Suspended Cassette Model Name FXUQ-MAV1 Capacity Range Capacity Index Connection Unit 0.8 HP 1 HP 1.25 HP 1.6 HP 20 25 31.25 40 2 HP 3 HP 4 HP 5 HP 50 71 100 125 BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE 3 Note: BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details. 4

MAIN FEATURES Energy efficiency and quiet operation Outdoor units use Daikin s unique scroll compressor to realise energy saving performance and quiet operation. High COP during both cooling and heating operations One of the top features of the VRVIII-S is its energy efficiency. It achieves high COP during cooling and heating operations by employing Daikin s unique scroll compressor. Quiet operation provides luxurious comfort Quietness is yet another important feature of Daikin s VRVIII-S system. To reduce noise and realise comfortable operation, latest technologies and features are applied to the outdoor units. 4 HP 5 HP 6 HP 4 HP 5 HP 6 HP VRVII-S Previous model RXYM-MVM 3.65 3.28 2.92 3.68 3.41 3.19 Above values are based on the following nominal conditions: 2 Ceiling Mounted Cassette (Round Flow) type units are connected (4 HP: FXFQ50P x 2; 5 HP: FXFQ63P x 2; and 6 HP: FXFQ63P + FXFQ80P.) : Indoor temp. of 27 CDB, 19 CWB, and outdoor temp. of 35 CDB. : Indoor temp. of 20 CDB, and outdoor temp. of 7 CDB, 6 CWB. Lower operation sound is achieved in cooling operation! VRVII-S Previous model RXYM-MVM High COP achieved in all ranges! 1 db(a) reduced in each model! 4 HP 51-1dB(A) 50 5 HP 52-1dB(A) 51 A collection of cutting-edge technologies realises efficient and quiet operation. The high efficiency compressor to achieve a higher COP 1 Compressor equipped with Reluctance DC motor Daikin DC inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet* 1 and reluctance torque* 2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. Motor efficiency (%) 90 80 70 60 Reluctance DC motor More than 20% AC motor Conventional DC motor 50 0 30 60 90 120 Rotational speed (rps) Small load Low capacity Large load High capacity Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products. *1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2 The torque created by the change in power between the iron and magnet parts. Reluctance DC motor >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency. Sine wave DC inverter 2 3 1 RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE Nighttime quiet operation function Operation sound level selectable from 3 steps for the night mode Mode 1. Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours* 1 after the peak temperature in the daytime, and operation will return to normal 10 hours* 2 after that. The operation sound level for the night mode can be selected from 47 db(a) (Step 1), 44 db(a) (Step 2) and 41 db(a) (Step 3). Mode 1. Automatic mode Capacity % Load % 100 Peak in outdoor temperature 8 hrs 10 hrs 50 (Initial setting) (Initial setting) 2 Smooth Air Inlet Bell Mouth and Aero Spiral Fan These two features work to reduce sound. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence. With the bent blade edge Without the bent blade edge Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence. 5 Mode 2. Manual mode Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA104A61 or DTA104A62, and a locally obtained timer are necessary.) Mode 3. Combined mode Combinations of modes 1 and 2 can be used depending on your needs. *1. Initial setting. Can be selected from 6, 8 and 10 hours. *2. Initial setting. Can be selected from 8, 9 and 10 hours. Operation sound db(a) 0 50 47 44 41 Step 1 max. - 3 db(a) ( 4 HP/11.2 ) Step 2 max. - 6 db(a) ( 4 HP/11.2 ) Step 3 max. - 9 db(a) ( 4 HP/11.2 ) Night mode starts Night Mode Step 1: 47 db(a) Step 2: 44 db(a) Step 3: 41 db(a) Night mode ends 8:00 12:00 16:00 20:00 0:00 4:00 8:00 Note: This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in the graph is just an example. The capacity reduction rate differs depending on the operation sound level step selected. 3 DC fan motor Efficiency improved in all areas compared to conventional AC motors, especially at low speeds. DC fan motor structure Efficiency (%) 100 80 60 40 Approx. 40% increase 20 DC motor efficiency (comparison with AC motor) DC motor Approx. 20% increase AC motor 0 200 300 400 500 600 700 800 900 1000 Motor speed (rpm) Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory. 6

MAIN FEATURES Design flexibility VRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and multiple indoor unit combinations, which provides generous freedom for office and shop design both inside and out. As many as 9 indoor units can be connected to a single outdoor unit Multiple indoor unit combinations are possible.* As many as 9 indoor units can be connected to a single outdoor unit, making the VRVIII-S a remarkably versatile system. * Total capacity index of connectable indoor units must be 50-130 % of the capacity index of the outdoor unit. For a 6 HP installation Long piping design possible The VRVIII-S provides the long piping length possibility of 150 m, with a total piping length of 300 m. If the outdoor unit is installed above indoor units the level difference can be up to a maximum of 50 m. These generous allowances facilitate an extensive variety of system designs. Actual piping length Max. 150 m 1 2 3 4 5 6 7 8 9 Total piping length Max. 300 m Max. 9 units * 2 >> Max. 8 indoor units for a 5 HP installation >> Max. 6 indoor units for a 4 HP installation Max. 15 m Level difference between indoor units Max. 50 m* 1 Level difference Notes: *1. 40 m when the outdoor unit is installed below indoor units. *2. Maximum piping length between the indoor unit and the first branch is 40 m. Easy installation A variety of functions are provided that make installation easier, such as simple wiring and piping and automatic test operation. Easy wiring A printed circuit board has been adopted that is easy to see and wire during installation. Automatic test operation Simply press the test operation button and the unit performs an automatic system check, including wiring, shutoff valves, and sensors. The results are returned automatically after the check finishes. Simple wiring and piping connection Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily. >> Super wiring system A super wiring system is used to enable shared use of the wiring between indoor and outdoor units and the central control wiring, with a relatively simple wiring operation. The DIII-NET counication system is employed to enable the use of advanced control systems. Central remote controller Outdoor unit Indoor unit Previous model VRVII-S >> REFNET piping system Wide operation temperature range The versatile operation range of the VRVIII-S system works to reduce limitations on installation locations. The operation temperature range for heating goes all the way down to -20 C, while cooling can be performed with outdoor temperatures as high as 46 C. Both these achievements are due to the adoption of a high-pressure dome-type compressor. Outdoor temperature ( CDB) 50 40 30 20 10 0-10 Certified operation temperature range 46 CDB -5 CDB Outdoor temperature ( CWB) 20 15.5 CWB 10 0-10 -20 20 CWB Daikin s advanced REFNET piping system makes installation easy. Only two main refrigerant lines are required in any one system. REFNET greatly reduces the imbalances in refrigerant flow between units, while using small-diameter piping. 7 8

CONTROL SYSTEMS Control systems The VRVIII-S system uses the same DIII-NET counication system as the VRV, enabling the use of advanced control systems. Individual control systems Navigation remote controller (Wired remote controller) (Option) Large buttons and arrow keys for easy operation. Guide on display gives an explanation of each setting. Backlight and dot matrix LCD display for easy viewing. Weekly schedule timer can be set up easily. 10 display languages are available. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian and Turkish) Wireless remote controller (Option) The same operation modes and settings as with wired remote controllers are possible. A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included. A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow, Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted type is mounted into the indoor unit. Signal receiver unit can be installed on the panel ex. Ceiling Mounted Cassette (Round Flow) type BRC1E61 Signal receiver unit (Separate type) Wired remote controller (Option) Displays current airflow, swing, temperature, operating mode and timer settings. Wired remote controller with weekly schedule timer (Option) Adds weekly schedule timer function. Wireless remote controller *Wireless remote controller and signal receiver unit are sold as a set. *Refer to page 35 for the name of each model. Signal receiver unit (Installed type) BRC1C62 Control of Cool/Heat In all the series of VRV, Cool/Heat changeover in the same refrigerant changeover circuit can be changed by the remote controller of the indoor unit. Outdoor unit Equipment related to the central control BRC1D61 Notes: 1. Standard remote controllers (BRC1C62) not required. 2. If the BRC1D61 is connected to the centralised remote controllers (DCS303A51, DCS302CA61, DCS301BA61, DST301BA61), the schedule function is not available. The wired remote controller supports a wide range of control functions Group control One remote controller can control the operation of max.16 indoor units at the same time. 1 Control by two remote controller The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely. (The last coand has a priority.) Of course, the group control by two remote controller is also possible. Simplified remote controller (Option) Exposed type (BRC2C51) Concealed type (For hotel use) (BRC3A61) The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms. The exposed type remote controller is fitted with a thermostat sensor. Wide variation of remote controllers for indoor units Navigation remote controller (Wired remote controller) (BRC1E61) Wired remote controller (BRC1C62) The concealed type remote controller smartly fits into a night table or console panel in a hotel room. FXFQ FXZQ FXCQ FXKQ FXDQ FXMQ FXHQ FXAQ FXL(N)Q FXUQ Remote controller Remote controller Remote controller Remote controller Remote controller Remote controller 1 2 3 Remote controller Heat Reclaim Ventilator Indoor unit Forced OFF input Remote controller 4 2 Remote control The wiring of remote controller can be extended to max. 500 m and it is possible to install the remote controllers for the different indoor units in one place. 3 Control for the combined operation The operation of Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter. 4 Expansion of system control The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc. Wired remote controller with weekly schedule timer (BRC1D61) Wireless remote controller* (Installed type signal receiver unit) Wireless remote controller* (Separate type signal receiver unit) Simplified remote controller (Exposed type) (BRC2C51) Simplified remote controller (Concealed type: for Hotel use) (BRC3A61) 9 Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. *Refer to page 35 for the name of each model. 10

CONTROL SYSTEMS Centralised control systems Up to 64 groups of indoor units (128 units) can be centrally controlled. Optional controllers for centralised control can be combined and optimised in accordance with building scale and purpose. System integration with various air-conditioning peripheral equipment such as Heat Reclaim Ventilator is easy. Wiring can be run up to a total length of 2 km, and adapts easily to large-scale system expansion. DCS303A51 Residential central remote controller* (Option) Max. 16 groups of indoor units can be easily controlled with the large LCD panel. Max. 16 groups (128 indoor units) controllable Backlight and large LCD panel for easy readability ON/OFF, temperature settings and scheduling can be controlled individually for indoor units. All indoor units can be turned on or off at once with ALL button. Each group has a dedicated button for convenience. Outside temperature display *For residential use only. Cannot be used with other centralised control equipment. Central remote controller (Option) Unified on/off controller (DCS301BA61) Connection of up to 8 units possible Connectable number of centralised control equipment Address setting of central control can be performed from the remote controller. Independent and centralised control of Heat Reclaim Ventilator is possible. DCS302CA61 Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller. Max. 64 groups (128 indoor units) controllable Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers, which can control from 2 different places. Zone control Malfunction code display Max. wiring length 1,000 m (Total: 2,000 m) Connectable with Unified ON/OFF controller, schedule timer and BMS system Airflow volume and direction can be controlled individually for indoor units in each group operation. Ventilation volume and mode can be controlled for Heat Reclaim Ventilator. Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer. Central remote controller Unified on /off controller Schedule timer 2 units 8 units 1 unit Group control of up to 16 units is possible 1 (group control via automatic address setting) Unified ON/OFF controller (Option) Max. 16 groups of indoor units can be operated simultaneously/individually. Forced shut-down input Central remote controller (DCS302CA61) Up to 2 units connectable Schedule timer (DST301BA61) 1 unit connection possible; 8 weekly schedule control patterns possible System without remote control is also available. Interface adaptor for SkyAir series (built-in indoor unit) (DTA102A52) 6 cores 7 cores max. Unification adaptor for computerised control (DCS302A52) Central control adaptor kit (DTA107A55) Wiring adaptor for other airconditioners (DTA103A51) Interlink Building Management System (host computer monitor panel) also possible 1. Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. Certain indoor units limit the functions of some control systems. For more details, please refer to the Engineering Data Book. Outdoor-air processing unit can be connected. DCS301BA61 DST301BA61 Max. 16 groups (128 indoor units) controllable 2 remote controllers can be used to control from 2 different places. Operating status indication (Normal operation, Alarm) Centralised control indication Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 ) Connectable with Central Remote controller, Schedule timer and BMS system Schedule timer (Option) Max. 128 indoor units can be operated as prograed schedule. Max. 128 indoor units controllable When used in combination with a central remote controller, a maximum of 8 weekly schedule patterns can be set, while the central controller can be used to select desired zones. Up to 2 ON/OFF pairs can be set per day. Max. 48 hours back up power supply Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 ) Connectable with Central Remote controller, Unified ON/OFF controller and BMS system 11 12

CONTROL SYSTEMS Advanced control systems New One touch selection to total air comfort Daikin proudly introduces its new intelligent Touch Manager, a VRV system controller featuring an array of simple, useful system management functions for added value. Up to 2,560 groups (5,120 indoor units) can be controlled by one system system overview Air Conditioning Network Service System Internal modem (option) New DCM601A51 Counication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system. system overview DCS601C51 System Dio Unit DEC102A51 (Option) Input (Lights) Di Unit DEC101A51 (Option) Input (Key signal - General purpose ADP) Phone line LAN line Max. 64 groups Set temperature change coand OFF coand Internet Intranet LAN itm plus adaptor line Max. 50m itm plus adaptor (Max. 7 adaptors) Web Access USB memory Fire alarm Di/Pi line Max. 200m h meter I/O expansion line Max. 500m Di/Pi port I/O System (Max. 30 modules) I/O module I/O module I/O module Air Conditioning Network Service System modem for Via internet System Components ACC centre Air Conditioning Network Service System (Optional Maintenance Service) RS-232C D -NET Plus Adaptor DCS601A52 (Option) Indoor Unit D -NET Number of indoor units expanded from 64 to 128. Heat Reclaim Ventilator Web Access Lighting Pump Fan Sensor Features Central control Handy area settings simplify detailed management of VRV. Display of floor plans enables a quick search of desired air conditioning units. Operation history shows manner of control and origin in past operations of air conditioning units. Remote access Remote access with a PC allows total air conditioning management using the same type of screens as those displayed in the intelligent Touch Manager. Authorised users can centrally control individual air conditioning units from their own computers. Automatic control VRVs are controlled automatically throughout the year by the schedule function. Interlocking VRVs and other equipment enables easy automation of building facilities operation. Setback adjusts temperature settings even when rooms are unoccupied. Energy management The Energy Navigator feature simplifies energy management by tracking energy consumption data and identifying inefficient operation. Troubleshooting Contact information of maintenance contractors can be registered and displayed. E-mails are sent automatically to alert of malfunctions and potential trouble. The intelligent Touch Manager can link to the Air Conditioning Network Service System for 24-hour monitoring of operating conditions and status. Scalability A single intelligent Touch Manager can manage a small building or be expanded to handle medium- to large-sized buildings. Large building properties can also take advantage of the itm integrator to link up and expand system up to 5 intelligent Touch Managers for integrated control. Features Colour LCD touch panel icon display Small manageable size Simplified engineering Multi language (English, French, Italian, German, Spanish, Dutch, Portuguese, Chinese and Korean) Yearly schedule Auto heat/cool change-over Temperature limitation Enhanced history function Simple Interlock Function Built-in modem for connecting to Air Conditioning Network Service System (Option) Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option) Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit) 13 14

INDOOR UNIT LINEUP Ceiling Mounted Cassette (Round Flow) FXFQ25P/ FXFQ32P/ FXFQ40P FXFQ50P/ FXFQ63P/ FXFQ80P FXFQ100P/ FXFQ125P Ceiling Mounted Cassette (Compact Multi Flow) FXZQ20M/ FXZQ25M FXZQ32M/FXZQ40M FXZQ50M 360 airflow improves temperature distribution and offers a comfortable living environment. Quiet, compact, and designed for user comfort The industry s first* Round Flow Ceiling Mounted Cassette type offers 360 airflow with improved temperature distribution. 4-way flow Round Flow Dimensions correspond with 600 X 600 architectural module ceiling design specifications. Low operation sound level (db(a)) FXZQ-M 20/25 32 40 50 There are areas of There are much fewer uneven temperature. areas of uneven temperature. *As of April 2004, the release date for Japan. All models are lighter than the conventional ones. Ex: Models FXFQ25P-50P are 4.5 lighter (reduced from 24 to 1 ). pump is equipped as standard accessory, and the lift height has been improved from 750 to 850. 850 A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating. Treated surface Resists soiling Example of airflow patterns: 360 airflow is available, as well as 2- to 4-way flows, so you can choose the most suitable airflow pattern depending on location or room layout. Untreated surface Dirt and grime Condition after exposure to the smoke of 600 cigarettes in 1 m 3 enclosed space. Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level FXFQ-P Sound level (HH/H/L) 25/32 40 50 63 100 (db(a)) 125 30/28.5/27 31/29/27 32/2/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 80 All-round flow An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean. The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter. 4-way flow 3-way flow L-shaped 2-way flow Sound level (H/L) Comfortable airflow 1 Wide discharge angle: 0 to 60 0 Auto swing 60 60 0 Fixed angles: 5 levels Angles can be also set on site to prevent drafts (0-35 ) or soiling of the ceiling (25-60 ), other than standard setting (0-60 ). 2 230 V 240 V 2-, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room. 4-way flow 30/25 32/26 36/28 41/33 32/26 34/28 37/29 42/35 3-way flow 0 0 60 60 L-shaped 2-way flow For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close each unused outlet. pump is equipped as standard accessory with 750 lift. 750 15 Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet. 16

INDOOR UNIT LINEUP Ceiling Mounted Cassette (Double Flow) FXCQ20M/ FXCQ25M/ FXCQ32M FXCQ40M/ FXCQ50M/ FXCQ63M FXCQ80M/ FXCQ125M Ceiling Mounted Cassette Corner FXKQ25MA/ FXKQ32MA FXKQ40MA/ FXKQ63MA Thin, lightweight, and easy to install in shallow ceiling spaces Slim design for flexible installation The low profile unit (only 305 high) can be installed in a ceiling space as shallow as 350. All models feature a compact design with a depth of only 600. FXCQ-M 20 305 (When a high-efficiency filter is attached, the unit's height is 400.) Low operation sound level Sound level (H/L) 25/32 40/50 63 80 (db(a)) 125 220 V 32/27 34/28 34/29 37/32 39/34 44/38 240 V 34/29 36/30 37/32 39/34 41/36 46/40 Designed with higher airflow suitable for high ceiling application up to 3 metres. Slim body needs only 220 space above the ceiling. If you use a panel spacer (option), the unit can be installed in the minimum space of 195. Min.195 20 Single-flow type allows effective air discharge from corner or from drop-ceiling. pump is equipped as standard accessory with 500 lift. 500 Panel spacer Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature. (m) 3 2 1 28 C 32 C 30 C 26 C 24 C 22 C 20 C 0 1 2 3 4 5 6 (m) Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall. Main body Downward discharge Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature. pump is equipped as standard accessory with 600 lift. Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method). A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3 Set for front discharge using a suspended ceiling. Main body Air discharge grille (Option) Air discharge grille (Option) 600 Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy. Downward discharge is shut off and air is blown straight out (front discharge). A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3 17 18

INDOOR UNIT LINEUP Slim Ceiling Mounted Duct Slim design, quietness and static pressure switching Ceiling Mounted Duct FXMQ20P/ FXMQ25P/ FXMQ32P FXMQ40P/ FXMQ50P/ FXMQ63P FXMQ80P/ FXMQ100P/ FXMQ125P FXMQ140P Suited to use in drop-ceilings! FXDQ20PB/ FXDQ25PB/ FXDQ32PB Only 700 in width and 23 in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels. Great for hotel use! Only 700 200 FXDQ40NB/ FXDQ50NB/ FXDQ63NB Only 200 in height, this model can be installed in rooms with as little as 240 depth between the drop-ceiling and ceiling slab. 900 200 1,100 in width for the FXDQ63NB model. Middle and high static pressure allows for flexible duct design A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility. 30 Pa 100 Pa for FXMQ20P-32P 30 Pa 160 Pa for FXMQ40P 50 Pa 200 Pa for FXMQ50P-125P 50 Pa 140 Pa for FXMQ140P All models are only 300 in height, an improvement over the 390 height of conventional models. The weight of the FXMQ40P has been reduced from 44 to 28. Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level FXDQ-PB/NB 20/25/32 40 Sound level 33/31/29 34/32/30 35/33/31 36/34/32 (HH/H/L) The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 db(a). Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa. 50 (db(a)) 63 AIR Discharge grille* Suspension bolt* AIR Air filter Suction grille* External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model. 10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models. 15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models. 240 *To be obtained locally FXDQ-PB and FXDQ-NB models are available in two types to suit different installation conditions. FXDQ-PB/NBVE: with a drain pump (750 lift) as a standard accessory FXDQ-PB/NBVET: without a drain pump 750 Ceiling 300 Easy installation in buildings with narrow ceiling spaces pump is equipped as standard accessory with 700 lift. 700 Ceiling Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level FXMQ-P 20/25 32 Energy-efficient 40 The adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 20% decrease in energy consumption. (FXMQ125P) 50 (db(a)) 140 Sound level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43 (HH/H/L) 63 80/100 125 Improved ease of installation Airflow rate can be controlled using a remote controller during test operation. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately ±10% of the rated HH tap airflow for FXMQ20P-125P. Improved ease of maintenance The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. 19 20

INDOOR UNIT LINEUP Ceiling Suspended Wall Mounted FXHQ32MA/ FXHQ63MA FXHQ100MA New FXAQ20P/ FXAQ25P FXAQ32P/ FXAQ40P FXAQ50P/ FXAQ63P Slim body with quiet and wide airflow Adoption of QUIET STREAM FAN Stylish flat panel design harmonised with your interior décor Stylish flat panel design creates a graceful harmony that enhances any interior space. Uses the quiet stream fan and many advanced technologies. Sound absorption material Flat panel can be cleaned with only the single pass of a cloth across their smooth surface. Flat panel can also be easily removed and washed for more thorough cleaning. Turbulent flow is produced Quiet stream fan Straightening vane Low operation sound level FXAQ-P 20 25 32 40 50 (db(a)) 63 Low operation sound level (db(a)) Sound level (H/L) 35/31 36/31 38/31 39/34 42/37 47/41 FXHQ-MA Sound level (H/L) 32 36/31 63 39/34 100 45/37 pan and air filter can be kept clean by mould-proof polystyrene. Installation is easy pump kit (option) can be easily incorporated. Vertical auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops. 100 600 pump kit (built inside main unit) Wide air discharge openings produce a spreading 100 airflow. Maintenance is easy Non-dew Flap with no implanted bristles Bristle-free Flap minimises contamination and makes cleaning simpler. Easy-to-clean flat design Non-dew Flap Maintenance is easier because servicing can be performed from below the unit. A long-life filter (maintenance free up to one year) is equipped as standard accessory. 5 steps of discharge angle can be set by remote controller. Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 10 for cooling and 70 for heating) Flexible installation pipe can be fitted to from either left or right sides. pump kit is available as optional accessory, which lifts the drain 1,000 from the bottom of the unit. Height of drain-up 1,000 pump kit Indoor unit 21 22

INDOOR UNIT LINEUP Floor Standing FXLQ20MA/ FXLQ25MA FXLQ32MA/FXLQ40MA FXLQ50MA/ FXLQ63MA Connection unit series indoor units Ceiling Suspended Cassette (50 Hz only) FXUQ71MA FXUQ100MA FXUQ125MA Suitable for perimeter zone air conditioning Floor Standing types can be hung on the wall for easier floor cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier. A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3 Concealed Floor Standing Wall hanging Floor installation This thin indoor unit achieves optimum air distribution, and can be installed without the need for ceiling cavity Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available. 4-way airflow from the centre of the store. The 3-way airflow can distribute comfortable air throughout the room. Only one unit is needed to distribute comfortable air throughout an L-shaped store. FXNQ20MA/ FXNQ25MA FXNQ32MA/ FXNQ40MA FXNQ50MA/ FXNQ63MA Designed to be concealed in the perimeter skirting-wall The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design. The connecting port faces downward, greatly facilitating on-site piping work. A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m 3 Connecting port Refrigerant piping Applies also to Floor Standing type (FXLQ-MA). Connection unit BEVQ71MA/BEVQ100MA/BEVQ125MA Liquid pipe Refrigerant piping layout VRV -S series outdoor unit Gas pipe length* 1 Connection unit is the device for connecting above indoor unit to VRVIII-S. Connection unit for indoor unit BEVQ-MAVE Indoor unit External wiring layout Super wiring (DIII-NET) Single-phase 220-240 V power supply Indoor unit Remote controller *1 Model FXUQ-MA Maximum piping length between the BEV unit and the indoor unit. 5 m Notes: When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA102A52). Connection unit BEVQ-MA is necessary for each indoor unit. The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m. The BEV unit must be installed within a maximum height difference between indoor units of 15 m. Branching of the refrigerant piping is not possible downstream of the BEV unit. 23 24

SPECIFICATIONS 25 INDOOR UNITS Ceiling Mounted Cassette (Round Flow) capacity capacity (50 Hz/60 Hz) Airflow rate (HH/H/L) Sound level (HH/H/L) Panel (Option) Model Colour Weight (*1) (*1) (*1) FXFQ25PVE FXFQ32PVE FXFQ40PVE FXFQ50PVE FXFQ63PVE FXFQ80PVE FXFQ100PVE FXFQ125PVE 2,500 9,900 2.9 2,800 10,900 3.2 Galvanised steel plate 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 288X840X840 288X840X840 1 VP25 (External Dia, 32/Internal Dia, 25) BYCP125K-W1 Fresh white 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 5.5 3,200 12,600 3.7 3,400 13,600 4.0 1 5.5 1-phase, 220-240 V/220 V, 50/60 Hz 4,000 16,000 4.7 4,300 17,100 5.0 459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794 1 5.5 5,000 19,800 5.8 5,400 21,500 6.3 1 5.5 6,300 24,900 7.3 6,900 27,300 8.0 22 5.5 8,000 31,700 9.3 2.8 3.6 4.5 5.6 7.1 9.0 8,600 34,100 10.0 22 5.5 10,000 39,600 11.6 10,800 42,700 12.5 5.5 12,500 49,500 14.5 11.2 14.0 13,800 54,600 0.033/0.032 0.033/0.032 0.047/0.042 0.052/0.050 0.066/0.063 0.093/0.092 0.187/0.186 0.209/0.208 0.027/0.027 0.027/0.027 0.034/0.034 0.038/0.038 0.053/0.053 0.075/0.075 0.174/0.174 0.200/0.200 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 16.0 32/26/20 33/28/22.5 db(a) 30/28.5/27 30/28.5/27 31/29/27 32/2/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 Ceiling Mounted Cassette (Compact Multi Flow) capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) Sound level (H/L) Panel (Option) 230 V, 50 Hz- 240 V, 50 Hz- 220 V, 60 Hz Model Colour Weight (*1) (*1) (*1) db(a) FXZQ20MVE 2,000 7,800 2.3 2.2 2,200 8,500 2.5 0.073/0.075 0.064/0.069 9/7 318/247 Galvanised steel plate 30/25-32/26-32/29 30/25-32/26-32/29 32/26-34/28-33/29 36/28-37/29-36/30 41/33-42/35-41/34 55X700X700 2.7 FXZQ25MVE 1-phase, 220-240 V/220 V, 50 Hz/60 Hz 2,500 9,900 2.9 2.8 2,800 10,900 3.2 0.073/0.075 0.064/0.069 9/7 318/247 VP20 (External Dia, 26/Internal Dia, 20) 55X700X700 2.7 FXZQ32MVE Note: Specifications are based on the following conditions; : Indoor temp.: (*1)27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 3,200 12,600 3.7 3.6 3,400 13,600 4.0 0.076/0.080 0.068/0.073 /7.5 335/265 286X575X575 18 BYFQ60B8W1 White (6.5Y/0.5) 55X700X700 2.7 FXZQ40MVE 4,000 16,000 4.7 4.5 4,300 17,100 5.0 0.089/0.095 0.080/0.088 11/8 388/282 55X700X700 2.7 25 25 5.5 FXZQ50MVE 5,000 19,800 5.8 5.6 5,400 21,500 6.3 0.115/0.128 0.107/0.122 14/10 493/353 55X700X700 2.7 Ceiling Mounted Cassette (Double Flow) capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) Sound level (H/L) Ceiling Mounted Cassette Corner capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) 50 Hz 60 Hz 220 V Sound level (H/L) 240 V Panel (Option) Model Colour Weight 220 V 240 V Panel (Option) Model Colour Weight (*1) (*1) (*1) db(a) (*1) (*1) (*1) db(a) FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE 2,000 7,800 2.3 2,200 8,500 2.5 7/5 247/177 32/27 305X775X600 26 FXKQ25MAVE 2,500 9,900 2.9 2,800 10,900 3.2 11/9 FXKQ32MAVE 3,200 12,600 3.7 3,400 13,600 4.0 Galvanised steel plate FXKQ40MAVE 4,000 16,000 4.7 4,300 17,100 5.0 FXKQ63MAVE 6,300 24,900 2.8 3.6 4.5 7.1 7.3 6,900 27,300 8.0 11/9 13/10 18/15 388/318 388/318 459/353 635/530 38/33 38/33 40/34 42/37 40/35 40/35 42/36 44/39 215X1,110X710 31 70X1,240X800 8.5 BYBC32G-W1 1-phase, 220-240 V/220 V, 50/60 Hz 0.066/0.069 0.066/0.069 0.076/0.092 0.105/0.120 0.046/0.049 0.046/0.049 0.056/0.072 0.085/0.100 11/8.5 11/8.5 13/10 18/13 388/300 388/300 459/353 635/459 215X1,110X710 31 VP25 (External Dia, 32/Internal Dia, 25) BYK45FJW1 70X1,240X800 8.5 Galvanised steel plate VP25 (External Dia, 32/Internal Dia, 25) White (10Y9/0.5) 53X1,030X680 53X1,030X680 53X1,030X680 53X1,245X680 53X1,245X680 53X1,430X680 53X1,920X680 53X1,920X680 8.0 2,500 9,900 2.9 2,800 10,900 3.2 9/6.5 318/230 34/28 305X775X600 26 8.0 1-phase, 220-240 V/220 V, 50/60 Hz 3,200 12,600 3.7 3,400 13,600 4.0 9/6.5 318/230 34/28 305X775X600 26 8.0 4,000 16,000 4.7 4,300 17,100 5.0 12/9 424/318 34/29 305X990X600 31 8.5 BYBC50G-W1 5,000 19,800 12/9 424/318 34/29 305X990X600 32 8.5 White (10Y9/0.5) 215X1,110X710 31 70X1,240X800 8.5 16.5/13 582/459 37/32 305X1,175X600 305X1,665X600 305X1,665X600 35 BYBC63G-W1 26/21 918/741 39/34 47 12.0 BYBC125G-W1 215X1,310X710 34 BYK71FJW1 70X1,440X800 33/25 1,165/883 44/38 34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40 5.8 5,400 21,500 6.3 6,300 24,900 7.3 6,900 27,300 8.0 8,000 31,700 9.3 8,600 34,100 10.0 12,500 49,500 14.5 2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0 13,800 54,600 0.077/0.081 0.092/0.095 0.092/0.095 0.130/0.132 0.130/0.132 0.161/0.157 0.209/0.216 0.256/0.278 0.044/0.048 0.059/0.062 0.059/0.062 0.097/0.099 0.097/0.099 0.126/0.124 0.176/0.183 0.223/0.245 Note: Specifications are based on the following conditions; : Indoor temp.: (*1)27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 16.0 48 12.0 26

SPECIFICATIONS 27 Slim Ceiling Mounted Duct (700 width type) capacity capacity (FXDQ-PBVE: 50 Hz/60 Hz) (FXDQ-PBVET: 50 Hz/60 Hz) Airflow rate (HH/H/L) with drain pump without drain pump External static pressure Sound level (HH/H/L) 2 3 (*1) (*1) (*1) Pa db(a) FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET 2,000 7,800 2.2 2,200 8,500 2,500 9,900 2,800 10,900 Galvanised steel plate 3,200 12,600 3,400 13,600 2.5 3.2 4.0 0.086/0.092 0.086/0.092 0.089/0.095 0.067/0.073 0.067/0.073 0.070/0.076 8.0/7.2/ 282/254/226 1-phase, 220-240 V/220 V, 50/60 Hz 2.3 2.9 3.7 8.0/7.2/ 282/254/226 8.0/7.2/ 282/254/226 33/31/29 33/31/29 33/31/29 200X700X620 23 2.8 3.6 0.067/0.073 0.067/0.073 0.070/0.076 0.067/0.073 0.067/0.073 0.070/0.076 30-10 1 200X700X620 23 VP20 (External Dia, 26/Internal Dia, 20) 200X700X620 Slim Ceiling Mounted Duct (900/1,100 width type) capacity capacity (FXDQ-NBVE: 50 Hz/60 Hz) (FXDQ-NBVET: 50 Hz/60 Hz) Airflow rate (HH/H/L) with drain pump without drain pump External static pressure Sound level (HH/H/L) 2 3 (*1) (*1) (*1) Pa db(a) 4,000 16,000 4,300 17,100 1-phase, 220-240 V/220 V, 50/60 Hz 5,000 19,800 5,400 21,500 Galvanised steel plate 44-15 1 VP20 (External Dia, 26/Internal Dia, 20) 23 FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE FXDQ40NBVET FXDQ50NBVET FXDQ63NBVET 6,300 24,900 4.7 5.8 7.3 4.5 5.6 7.1 6,900 27,300 5.0 6.3 8.0 0.160/0.182 0.165/0.185 0.181/0.192 0.147/0.168 0.152/0.170 0.168/0.179 0.147/0.168 0.152/0.170 0.168/0.179 0.147/0.168 0.152/0.170 0.168/0.179 10.5//8.5 371/335/300 12.5/11.0/10.0 441/388/353 16.5/14.5/13.0 583/512/459 34/32/30 35/33/31 36/34/32 200X900X620 27 200X900X620 28 200X1,100X620 Note: Specifications are based on the following conditions; : Indoor temp.: (*1) 27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 1: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.) 2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 db(a). 3: Values are based on the following conditions: FXDQ-PB external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa. 31 Ceiling Mounted Duct capacity capacity (50 Hz/60 Hz) Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) capacity capacity (50 Hz/60 Hz) 1-phase, 220-240 V/220 V, 50/60 Hz Galvanised steel plate FXMQ40PVE 16,000 FXMQ50PVE Note: Specifications are based on the following conditions; : Indoor temp.: (*1) 27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P. 4,000 4.7 4,300 17,100 5.0 565/459/388 300X700X700 28 VP25 (External Dia, 32/Internal Dia, 25) 5,000 19,800 5.8 4.5 5.6 5,400 21,500 0.081/0.080 0.081/0.080 0.085/0.084 0.194/0.193 0.215/0.214 0.069/0.069 0.069/0.069 0.073/0.073 0.182/0.182 0.203/0.203 Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) (*1) (*1) (*1) FXMQ20PVE 2,000 7,800 2.3 2.2 2,200 8,500 2.5 9/7.5/6.5 318/265/230 6.3 16/13/11 18/16.5/15 635/582/530 1 1 1 1 1 Pa 30-100 30-100 30-100 30-160 50-200 db(a) 33/31/29 300X550X700 25 FXMQ25PVE 2,500 9,900 2.9 2.8 2,800 10,900 3.2 9/7.5/6.5 318/265/230 33/31/29 300X550X700 25 FXMQ32PVE 3,200 12,600 3.7 3.6 3,400 13,600 4.0 /8/7 335/282/247 34/32/30 39/37/35 41/39/37 300X550X700 25 300X1,000X700 FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE 6,300 24,900 7.3 6,900 27,300 8.0 688/618/565 300X1,000X700 36 8,000 31,700 9.3 8,600 34,100 10.0 883/794/706 300X1,000X700 36 1-phase, 220-240 V/220 V, 50/60 Hz 10,000 39,600 11.6 10,800 42,700 12.5 Galvanised steel plate 1,130/953/812 300X1,400X700 46 12,500 49,500 14.5 7.1 9.0 11.2 14.0 13,800 54,600 0.230/0.229 0.298/0.297 0.376/0.375 0.461/0.460 0.218/0.218 0.286/0.286 0.364/0.364 0.449/0.449 (*1) (*1) (*1) 16.0 1/17.5/16 25/22.5/20 32/27/23 39/33/28 1 1 1 1 Pa 50-200 50-200 50-200 50-200 db(a) 42/40/38 43/41/39 43/41/39 44/42/40 VP25 (External Dia, 32/Internal Dia, 25) 36 1,377/1,165/988 1,624/1,377/1,130 300X1,400X700 46 14,300 57,000 16.7 16.0 15,500 61,400 18.0 0.461/0.460 0.449/0.449 46/39/32 50-140 1 46/45/43 300X1,400X700 47 28

SPECIFICATIONS Ceiling Suspended capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) Sound level (H/L) Wall Mounted capacity capacity Power consumption Airflow rate (H/L) Sound level (H/L) (*1) (*1) (*1) db(a) (*1) (*1) (*1) db(a) FXHQ32MAVE 3,200 12,600 3.7 3,400 13,600 4.0 FXHQ63MAVE 24,900 White (10Y9/0.5) Note : Specifications are based on the following conditions; : Indoor temp.: (*1) 27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level : Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 6,300 7.3 6,900 27,300 8.0 FXHQ100MAVE 10,000 39,600 11.6 3.6 7.1 11.2 10,800 42,700 12.5 424/353 618/494 883/688 195X960X680 24 1-phase, 220-240 V/220 V, 50/60 Hz 0.111/0.142 0.115/0.145 0.135/0.199 0.111/0.142 0.115/0.145 0.135/0.199 12/10 17.5/14 25/1 36/31 39/34 45/37 195X1,160X680 28 VP20 (External Dia, 26/Internal Dia, 20) 195X1,400X680 FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE 2,000 7,800 2.3 2.9 3.2 36/31 290X795X238 11 1-phase, 220-240/220V, 50/60Hz 2,500 3,200 4,000 9,900 12,600 16,000 3.7 White (3.0Y8.5/0.5) 38/31 290X795X238 11 4.7 2.2 2.8 3.6 4.5 2,200 8,500 2.5 0.019 0.029 7.5/4.5 265/159 35/31 290X795X238 11 2,800 3,400 4,300 10,900 13,600 17,100 4.0 8/5 8.5/5.5 5.0 12/9 282/177 300/194 424/318 39/34 290X1,050X238 14 VP13 (External Dia, 18/Internal Dia, 13) 5,000 19,800 5,400 21,500 42/37 290X1,050X238 14 33 6,300 24,900 7.3 6,900 27,300 0.028 0.030 0.020 0.033 0.050 0.034 0.035 0.020 0.039 0.060 5.8 5.6 6.3 15/12 19/14 530/424 7.1 8.0 671/494 47/41 290X1,050X238 14 Floor Standing /Concealed Floor Standing FXLQ FXNQ capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) 220 V Sound level (H/L) 240 V Dimensions (HXWXD) FXLQ FXNQ FXLQ FXNQ (*1) (*1) (*1) db(a) FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE 2,000 7,800 2.3 2.2 2,200 8,500 7/6 247/212 600X1,000X222 25 2,500 9,900 2.9 2.8 2,800 10,900 FXLQ: Ivory white (5Y7.5/1) / FXNQ: Galvanised steel plate 7/6 247/212 600X1,000X222 25 1-phase, 220-240 V/220 V, 50/60 Hz 12,600 282/212 388/300 494/388 565/424 21O.D. Note: Specifications are based on the following conditions; : Indoor temp.: (*1) 27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 3,200 3.7 3.6 3,400 13,600 8/6 600X1,140X222 30 4,000 16,000 4.7 4.5 4,300 17,100 2.5 3.2 4.0 5.0 11/8.5 600X1,140X222 30 5,000 19,800 5.8 5.6 5,400 21,500 6.3 14/11 600X1,420X222 36 6,300 24,900 7.3 6,900 27,300 0.049/0.047 0.049/0.047 0.090/0.079 0.090/0.084 0.110/0.105 0.110/0.108 0.049/0.047 0.049/0.047 0.090/0.079 0.090/0.084 0.110/0.105 0.110/0.108 8.0 16/12 35/32 35/32 35/32 38/33 39/34 40/35 37/34 37/34 37/34 40/35 41/36 42/37 600X1,420X222 610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220 19 19 23 23 27 27 7.1 36 29 30

SPECIFICATIONS Connection unit series indoor units * A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data Book for details. * If indoor units from the Connection unit series are connected within a single refrigerant system to indoor units from any other series, cooling/heating switchover will not be possible using the remote controller of the Connection unit series indoor units. However, if the remote controller of an indoor unit from the other series is set as a master remote controller, cooling/heating switchover will be possible. * If all indoor units are from the Connection unit series, an outdoor unit Cool/Heat selector will be needed to enable cooling/heating switchover. * Group control between Connection Unit series equipment within one system is possible. However, group control with the other VRV indoor units is not possible. Ceiling Suspended Cassette (50 Hz only) capacity (Max.) Indoor unit capacity Power consumption Airflow rate (H/L) Indoor unit Connection unit Liquid Gas Kcal/h(*1) (*1) 7,100 (*1) 28,300 Kcal/h 8.3 7,700 30,700 9.0 671/494 165X895X895 25 1-phase, 220-240 V, 50 Hz 10,000 39,600 11.6 10,800 42,700 12.5 White(10Y9/0.5) 1,024/741 230X895X895 VP 20 (External Dia. 26/Internal Dia. 20) 31 (Flare) (Flare) 12,500 49,500 14.5 8.0 11.2 14.0 12,000 47,800 Sound level (H/L) 230 V db(a) 40/35 43/38 44/39 FXUQ71MAV1 BEVQ71MAVE 0.189 0.169 FXUQ100MAV1 BEVQ100MAVE FXUQ125MAV1 BEVQ125MAVE 14.0 1,130/812 230X895X895 Note: Specifications are based on the following conditions; : Indoor temp.: (*1) 27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 27 CDB, 19 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 0.298 0.278 0.298 0.278 19/14 29/21 32/23 31 Only capacity OUTDOOR UNITS Capacity control % colour Compressor Motor output Airflow rate Dimensions (H x W x D) Kcal/h RXMQ4PVE RXMQ5PVE RXMQ6PVE 1-phase, 220-230 V, 50 Hz/220 V 60 Hz 9,600 12,000 13,300 38,200 47,700 52,900 11.2 14.0 15.5 2.95 3.97 4.44 24 to 100 Hermetically sealed scroll type 2.5 3.0 3.5 1,345 x 900 x 320 125 Sound level db(a) 50 51 53 Operation range CDB -5 to 46 Refrigerant Heat Pump capacity capacity Power consumption Capacity control % colour Airflow rate Charge Liquid Gas Dimensions (H x W x D) Kcal/h Kcal/h Compressor Motor output ø (Flare) Ivory white (5Y7.5/1) 106 R-410A 4.0 ø (Flare) 1-phase, 220-230 V, 50 Hz/220 V 60 Hz 24 to 100 Hermetically sealed scroll type 1,345 x 900 x 320 125 ø (Flare) ø (Flare) ø19.1 (Brazing) RXYMQ4PVE RXYMQ5PVE RXYMQ6PVE 9,600 12,000 13,300 38,200 47,800 52,900 11.2 14.0 15.5 10,800 13,800 15,500 42,700 54,600 61,400 12.5 16.0 18.0 2.95 3.97 4.44 3.27 4.09 4.82 Ivory white (5Y7.5/1) 2.5 3.0 3.5 Sound level (/) db(a) 50/52 51/53 53/55 Operation range Refrigerant Charge Liquid Gas CDB CWB R-410A ø19.1 (Brazing) Note: Specifications are based on the following conditions; : Indoor temp.: 27 CDB, 1 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 20 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. Refrigerant charge is required. 106-5 to 46-20 to 15.5 4.0 31 32