Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

DIVISION 15 MECHANICAL

SECTION DUCTWORK

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

SECTION AIR DUCT ACCESSORIES

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SECTION DUCTWORK

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION AIR HANDLING UNIT

INDEX OF VA STANDARD DETAILS AS OF DECEMBER 2014

1.1 This section applies to air handling units for HVAC Systems.

SECTION (15820) - AIR DUCT ACCESSORIES

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION AIR OUTLETS AND INLETS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Contents INDEX. TDM Series Indirect Fired Heaters

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

DOCUMENT TABLE OF CONTENTS

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

SECTION AIR COILS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

University of Delaware

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

NC State University Design and Construction Guidelines Division 23 Basic Mechanical Requirements

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Ultra-sorb Models LV and LH

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

CxA to Answer this Section

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SAFETY AND INSTALLATION MANUAL MODEL 8100

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

AIR DUCT ACCESSORIES

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION AIR COILS

DUCT SYSTEMS CHAPTER 6

SECTION PLUMBING EQUIPMENT

University of Delaware

Inspection Checklist Mechanical Final

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Linear Floor Heaters

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

OKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS

DUCT SYSTEMS CHAPTER 6

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

HVAC Equipment Access Equipment Location

Direct Fired Heater Model AD Specification

TYPICAL CPA SPECIFICATIONS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION COOLING TOWERS

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

SECTION STEAM CONDENSATE PUMPS

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Chilled Water DOAS Fan Powered Terminal Units

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

DIVISION 23 - HVAC HVAC Air Distribution

AIR HANDLER SPECIFICATION

Inspection Checklist Mechanical Rough in

System and equipment drains shall be piped to a floor drain. Gauges shall be provided on the suction and discharge side of all pumps installed.

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

DIVISION 23 - HVAC HVAC Air Distribution

Union County Vocational - Technical Schools Scotch Plains, New Jersey


Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SECTION (15833) - HVAC POWER VENTILATORS

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

DIVISION 23 HVAC Hydronic Piping Systems

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

DUCT SYSTEMS CHAPTER 6

A. Codes and Standards that are Standard at the University:

Transcription:

DRAWING SYMBOLS 2 H4 DETAIL NUMBER DRAWING NUMBER WHERE DRAWN A H7 SECTION LETTER DRAWING NUMBER WHERE SHOWN BUILDING NO. WHERE EQUIPMENT IS LOCATED. EQUIPMENT ABBREVIATION (SUPPLY FAN) 26-SF 3 SUPPLY FAN NO. 3 IN BUILDING NO. 26 TYPICAL UNIT NO. BUILDING NO. WHERE EQUIPMENT IS LOCATED ITEM (TERMINAL UNIT SHOWN) 26-TU-I-I ITEM NUMBER (TERMINAL UNIT NO. 1) SERVED BY AIR HANDLER UNIT NO. 1 DETAIL TITLE / DRAWING SYMBOLS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230511-08.DWG

DUCTWORK SYMBOLS UP DN SUPPLY DUCT (UP & DOWN) UP DN EXHAUST DUCT (UP & DOWN) UP DN RETURN DUCT (UP & DOWN) ROUND AND SQUARE 4-WAY CEILING DIFFUSERS SQUARE 3-WAY CEILING DIFFUSERS SQUARE 2-WAY CEILING DIFFUSERS SQUARE 1-WAY CEILING DIFFUSERS LINEAR SLOT DIFFUSER SUPPLY TOP REGISTER OR GRILLE (WALL TYPE) EXHAUST OR RETURN CEILING REGISTER OR GRILLE EXHAUST OR RETURN BOTTOM REGISTER OR GRILLE (WALL TYPE) EXHAUST OR RETURN REGISTER OR TOP GRILLE (WALL TYPE) VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF CONNECT NEW DUCT TO EXISTING DUCT R INCLINED RISE, IN DIRECTION OF AIR FLOW D INCLINED DROP, IN DIRECTION OF AIR FLOW LIMIT OF DEMOLITION DETAIL TITLE / DUCTWORK SYMBOLS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230511-09.DWG

DUCTWORK SYMBOLS FC FLEXIBLE CONNECTION, EQUIPMENT, VIBRATION, OR SEISMIC VANED ELBOW (PROVIDE ALL SQUARE OR RECTANGULAR ELBOWS WITH VANES EVEN IF SYMBOL IS MISSING) VANED ELBOW (SHORT RADIUS) STANDARD RADIUS ELBOW (LONG RADIUS) 10x8 NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH) EXISTING DUCT TO REMAIN EXISTING DUCT TO BE REMOVED LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL SECTION.) FLEXIBLE DUCTWORK (INSULATED) DUCT WITH SOUND LINING MANUAL VOLUME DAMPER VD FD FIRE DAMPER BACK DRAFT DAMPER BDD DETAIL TITLE / DUCTWORK SYMBOLS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230511-10.DWG

AIR TERMINAL SYMBOLS TERMINAL UNIT WITH REHEAT COIL MB DOUBLE DUCT MIXING BOX. FAN POWERED VARIABLE VOLUME TERMINAL UNIT WITH HEATING COIL. DETAIL TITLE / AIR TERMINAL SYMBOLS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230511-13.DWG

1/4"x1 1/4" [6.4x31.4mm] IRON PIPE STRAP WATER STOP EXTERIOR WALL FLANGED CONNECTION PIPE SLEEVE 1/4"x1 1/4" [6.4x31.4mm] IRON PIPE CLAMP HIGH DENSITY POLYETHYLENE (HDPE) SLEEVE WITH INTEGRAL HOLLOW MOLDED STOP RING 4" WATER [100mm] LARGER THAN OUTSIDE DIAMETER OF PIPE 4" [100mm] 5/8" [16mm] ROD # SUPPORT ANCHOR (CONDENSER WATER OR CHILLED WATER) NTS DETAIL TITLE / SUPPORT ANCHOR (CONDENSER WATER OR CHILLED WATER) SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230511-26.DWG

# VARIES REMOVABLE COVER HIGH DENSITY INSERT TYPICAL COLD PIPE TYPICAL TYPE 40 SHIELD BANDED TO PIPE HOT PIPE TYPE 39 SADDLE CAULK AND SEAL 3/4" [19mm] 7/8"[22mm] 4"[100mm] 5.4# SLOPE CENTER BOLT FOR SPAN GREATER THAN 24"[600mm] 2 - SUPPORTS UP TO 24" [600mm] SPAN NOTES: 1. COORDINATE TRENCH DETAIL WITH ARCHITECTURAL & STRUCTURAL. PIPE TRENCH IN BUILDING 2. REFER TO SPECIFICATION, SEALING & CAULKING. NTS DESIGNER'S NOTE: COORDINATE TRENCH DETAIL WITH ARCHITECTURAL & STRUCTURAL. VARIES DETAIL TITLE / PIPE TRENCH IN BUILDING SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230511-27.DWG

STEAM LINE CONDENSATE RETURN LINE PROVIDE TWO "U" BOLTS WITH NUT & LOCK NUT ON STEAM LINE. SPOT WELD "U" BOLT TO PIPE & BOLT TO CHANNEL. PROVIDE ONE "U" BOLT WITH NUT & LOCK NUT ON RETURN LINE. SPOT WELD "U" BOLT TO PIPE & BOLT TO CHANNEL CHANNEL TO BE SET IN SIDE WALL OF TRENCH. CONCRETE TRENCH SIZE OF STEAM LINE GOVERNS SIZE OF CHANNEL. PLAN VIEW SCHEDULE SIZE OF PIPE INCH [mm] SIZE OF "U" BOLT INCH [mm] SIZE OF CHANNEL INCH [mm] 1-2 [25-50] 3/8 [10] DIA. 6 x 10.5 [150x265] 2-1/2-5 [65-125] 1/2 [15] DIA. 8 x 13.75 [200x345] 6-8 [150-200] 3/4 [20] DIA. 10 x 20 [250x500] SCHEDULE FOR 8 FT. [2.4m] SPAN OR LESS. # ANCHOR INSTALLATION STEAM/CONDENSATE PIPING IN TRENCH NTS DETAIL TITLE / ANCHOR INSTALLATION - STEAM/CONDENSATE PIPING IN TRENCH SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230511-28.DWG

b a b c FLEXIBLE MECHANICAL COUPLING (TYPICAL) HANGER (TYPICAL) ANCHOR (TYPICAL) d SEISMIC JOINT d DETAIL "A" (STEEL PIPE FOR WATER/GLYCOL) NOTE: 1. SEISMIC SEPARATION ASSEMBLY DETAIL SHOWN IN NFPA 13 (SPRINKLER PIPING), UTILIZING FLEXIBLE MECHANICAL COUPLINGS, MAY BE USED IN LIEU OF PIPING DETAIL SHOW ABOVE. SCHEDULE FOR PIPING CROSSING A SEISMIC JOINT LOCATION PIPE DETAIL DIMENSIONS INCHES [mm] a b c d e f - - - - - - - - - - - - - - - - - - # PIPING CROSSING A SEISMIC JOINT DETAIL "A" NTS DESIGNER'S NOTE: 1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOT MANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS AND MODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT PROJECT-SPECIFIC. THE MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THE DISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER. DETAIL TITLE / PIPING CROSSING A SEISMIC JOINT DETAIL "A" SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230511-29.DWG

b a b c RISE UP 12" [300mm] MINIMUM e HANGER (CLOSE TO ELBOW) d ANCHOR ANCHOR SEISMIC JOINT f f DETAIL "B" (PLASTIC PIPE FOR PRESSURIZED SYSTEMS) SCHEDULE FOR PIPING CROSSING A SEISMIC JOINT LOCATION PIPE DETAIL DIMENSIONS INCHES [mm] a b c d - - - - - - - - - - - - - - # NTS PIPING CROSSING A SEISMIC JOINT DETAIL "B" DESIGNER'S NOTE: 1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOT MANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS AND MODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT PROJECT-SPECIFIC. THE MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THE DISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER. DETAIL TITLE / PIPING CROSSING A SEISMIC JOINT DETAIL "B" SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230511-30.DWG

b a b A 6" [150mm] d HANGER A c & FLEXIBLE: BRONZE HOSE BRAID WITH SOLDIERED OR BRAZED ENDS HANGER ANCHOR ANCHOR e SEISMIC JOINT e DETAIL (COPPER "C" PIPE) COPPER PIPE 6" [150mm] 4" [100mm] MINIMUM RISE FLEXIBLE HOSE SECTION "A-A" SCHEDULE FOR PIPING CROSSING A SEISMIC JOINT DIMENSIONS INCHES [mm] LOCATION PIPE DETAIL a b c d e - - - - - - - - - - - - - - - - # PIPING CROSSING A SEISMIC JOINT DETAIL NTS DESIGNER'S NOTE: 1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOT MANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS AND MODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT PROJECT-SPECIFIC. THE MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THE DISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER. DETAIL TITLE / PIPING CROSSING A SEISMIC JOINT DETAIL "C" "C" SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230511-31.DWG

b a b HANGER c HANGER FLEXIBLE BALL JOINT HANGER d SEISMIC JOINT d ANCHOR DETAIL "D" (STEEL PIPE FOR STEAM OR WATER) ANCHOR SCHEDULE FOR PIPING CROSSING A SEISMIC JOINT LOCATION PIPE DETAIL DIMENSIONS INCHES [mm] a b c d - - - - - - - - - - - - - - PIPING CROSSING A SEISMIC # NTS JOINT DETAIL "D" DESIGNER'S NOTE: 1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOT MANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS AND MODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT PROJECT-SPECIFIC. THE MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THE DISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER. DETAIL TITLE / PIPING CROSSING A SEISMIC JOINT DETAIL "D" SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230511-32.DWG

a HANGER d b FLEXIBLE CONNECTOR c HANGER HANGER SEISMIC JOINT e e ANCHOR ANCHOR DETAIL "E" (STEEL PIPE FOR WATER) SCHEDULE FOR PIPING CROSSING A SEISMIC JOINT LOCATION PIPE DETAIL DIMENSIONS INCHES [mm] a b c d e f - - - - - - - - - - - - - - - - - - PIPING CROSSING A SEISMIC # NTS JOINT DETAIL "E" DESIGNER'S NOTE: 1. THIS CONFIGURATION SHOWN IN THIS DETAIL IS A SUGGESTED ARRANGEMENT, NOT MANDATED FOR USE IN AS IS CONDITION. THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER IN CHARGE OF THE PROJECT SHALL PROVIDE SEISMIC CALCULATIONS AND MODIFY THE CONFIGURATION AS NEEDED TO MAKE THE ARRANGEMENT PROJECT-SPECIFIC. THE MECHANICAL DESIGNER SHALL COMPLETE THE BLANK SCHEDULES BY INSERTING THE DISTANCES, TO BE CALCULATED AND FURNISHED BY PROVIDED BY THE REGISTERED PROFESSIONAL STRUCTURAL ENGINEER. DETAIL TITLE / PIPING CROSSING A SEISMIC JOINT DETAIL "E" SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230511-33.DWG

+Fy STEAM NOZZLE +My +Mz +Mx +Fz FRONT OF BOILER +Fx LONG AXIS OF BOILER ISOMETRIC VIEW TABLE OF FORCES AND MOMENTS DUE TO THERMAL EXPANSION AND WEIGHT OF STEAM LEAD AND VALVES BOILER NO. Fx Fy Fz LB [Kg] LB [Kg] LB [Kg] FT LB [J] FT LB [J] FT LB [J] ------ --[--]--[--]--[--] --[--] --[--] --[--] Mx My Mz TABLE OF FORCES AND MOMENTS DUE TO SEISMIC ACTION OF THE STEAM LEAD AND VALVES BOILER NO. Fx Fy Fz LB [Kg] LB [Kg] LB [Kg] FT LB [J] FT LB [J] FT LB [J] ------ --[--]--[--]--[--] --[--] --[--] --[--] Mx My Mz NOTES: 1. BOILERS SHALL BE DESIGNED TO WITHSTAND THE FORCES AND MOMENTS SHOWN ABOVE. 2. ADD ANY Fy FORCE (500 LB [230 Kg] MINIMUM) AS AN ESTIMATION OF THE WEIGHT EFFECT OF THE STEAM LEAD AND VALVE ON THE BOILER. BOILER AND PIPE HANGER SUPPLIERS SHALL COORDINATE TO DETERMINE THE EXACT Fy FORCE WHICH WILL BE IMPOSED ON THE STEAM NOZZLES. 3. DELETE THE SEISMIC TABLE ON NON-SEISMIC AREAS. # FORCES AND MOMENTS ON BOILER STEAM NOZZLES NTS DETAIL TITLE / FORCES AND MOMENTS ON BOILER STEAM NOZZLES SCALE : NONE DATE ISSUED : FEBRUARY 2008 CADD DETAIL NO. : SD230511-34.DWG

TYPICAL STRUCTURAL STEEL MEMBER FOR EQUIPMENT MOTOR SHAFT DRIVEN EQUIPMENT TYPE"B" WELDED STEEL BASE NUMBER OF ISOLATION UNITS AS REQUIRED STRUCTURAL STEEL FRAME SLEEVE ANCHOR BOLT REINFORCING BARS SPRING ISOLATOR SECTION A-A ALL WELDED STEEL FRAMEWORK TYPICAL STRUCTURAL STEEL MEMBER FOR EQUIPMENT MOTOR SHAFT A DRIVEN EQUIPMENT A TYPE "1" CONCRETE INERTIA BASE NUMBER OF ISOLATION UNITS AS REQUIRED # VIBRATION ISOLATION BASES NTS DETAIL TITLE / VIBRATION ISOLATION BASES SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230541-01.DWG

FLEXIBLE DUCT CONNECTIONS FAN INLET FAN DISCHARGE FLEXIBLE DUCT CONNECTIONS FAN SECTION COIL SECTION OR DISCHARGE DUCT TYPE "THR" THRUST VIBRATORS ISOLATORS AS SCHEDULED OR SPECIFIED RESTRAINT NOTES: 1. ATTACH THRUST RESTRAINTS SYMMETRICALLY ON BOTH SIDES OF THE FAN DISCHARGE. 2. ADJUST RESTRAINT TO ALLOW 1/4" [6 mm] MOVEMENT OF FAN AT START AND STOP. # THRUST RESTRAINT FOR FANS NTS DESIGNER'S NOTE: ON THE VIBRATION ISOLATION SCHEDULE OR UNDER THE TITLE OF THIS DETAIL DESIGNATE FANS REQUIRING RESTRAINT. THIS IS USUALLY SEPARATELY MOUNTED FAN SECTIONS FOR STATIC PRESSURE OVER 4" [100 mm] AND POSSIBLY FOR AXIAL FLOW FANS FOR STATIC PRESSURE OVER 4" [100 mm]. DETAIL TITLE / THRUST RESTRAINT FOR FANS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230541-02.DWG

ANCHOR A L B B 5D D 2D BOLT (TYP) PIPE SLEEVE (5D, 3" [75mm] MIN.) 1" [25mm] W FLOOR A CONCRETE BASE 5D WELD HEAD TO PLATE OR BEND OVER END 5D PLAN SECTION B-B TYPICAL ANCHOR BOLT NUT & WASHER EQUIPMENT BASE PLATE PROVIDE DOUBLE SLAB REINFORCING IN BASE AREA TYPICAL 16" [400mm] SECTION A-A (BASE POURED WITH FLOOR SLAB) ANCHOR BOLT NUT & WASHER PROVIDE #3 BARS 12" [300mm] O.C. EACH WAY IN THE BASE & DOWEL BASE TO FLOOR SECTION A-A (BASE NOT POURED WITH SLAB) L/10 L/10 5" MIN. [125mm] EQUIPMENT BASE PLATE 5" MIN. [125mm] NOTE: L & W DIMENSIONS SHALL BE 6" [150mm] GREATER THAN THE EQUIPMENT BASE PLATE. # CONCRETE EQUIPMENT NTS BASES DESIGNER'S NOTE: THIS DETAIL IS PRIMARILY FOR PUMPS WITHOUT ISOLATORS. COORDINATE DETAIL WITH ARCHITECTURAL AND STRUCTURAL. DETAIL TITLE / CONCRETE EQUIPMENT BASES SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230541-03.DWG

CROSS BRACING RODS ALL FOUR SIDES EQUIPMENT ANCHOR BOLT BASE NEOPRENE WASHER & SLEEVE HANGER ROD (TYP) BONDED STEEL PLATE CLAMP FLOOR RESILIENT PAD EQUIPMENT WEIGHT 250 LBS. [114KG] OR LESS LOCK NUTS (TYP) FLOOR MOUNT EQUIPMENT RESTRAINED BY RESILIENT PADS (TYPE DS) SEISMIC BRACING FOR LIGHT SUSPENDED EQUIPMENT NOTE: NOT REQUIRED FOR AIR TERMINAL UNITS. # NTS SEISMIC BRACING FOR EQUIPMENT DETAIL TITLE / SEISMIC BRACING FOR LIGHT SUSPENDED EQUIPMENT/ EQUIPMENT RESTRAINED BY RESILIENT PADS (TYPE DS) SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230541-04.DWG

STEEL EXPANSION SHIELD FOR EXISTING CONSTRUCTION AND INSERTS FOR NEW CONSTRICTION THIS TYPE SHALL BE USED ONLY IN SLABS OR BEAMS OF 4" [100mm] MIN DEPTH CONCRETE FLOOR SLAB 3/8" [10mm] MIN DIA EXPANSION BOLTS FOR EXISTING CONSTRUCTION AND INSERTS FOR NEW CONSTRUCTION CLIP ANGLE 3/8" [10mm] MIN DIA INSERTS NEW CONSTRUCTION ONLY. NUTS & WASHERS TURNBUCKLE 3/8" [10mm] MIN DIA HANGER RODS 3/8" [10mm] MIN DIA HANGER RODS FOR PIPES UNDER 2" [50mm] IN SIZE USE 1 1/2"x1 1/2"x1/4" [40x40x6.4mm] ANGLE. ALL PIPES 2" [50mm] & LARGER USE 3"x3"x1/4" [75x75x6.4mm] ANGLE # SECURING HANGER RODS IN CONCRETE NTS DETAIL TITLE / SECURING HANGER RODS IN CONCRETE SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230541-05.DWG

COLLAR DIA. COLLAR DIA. WIDTH OR LENGTH WIDTH OR LENGTH 18" MIN. [450mm] 18" MIN. [450mm] 5/8" [18mm] MINERAL FIBER 6" MIN. [150mm] 6" MIN. [150mm] DUCT CEILING INSULATION AS SPECIFIED CEILING CEILING DIFFUSER OR REGISTER SIDE VIEW END VIEW INSULATED DUCT TYPE COLLAR DIA. WIDTH OR LENGTH 6" MIN. 6" MIN. 6" MIN. [150mm] [150mm] 1-1/4" [32mm] FIRE RESISTANT DUCT INSULATION [150mm] DUCT CEILING EXTEND FROM CEILING TO TOP OF DUCT CEILING CEILING DIFFUSER SIDE VIEW OR REGISTER END VIEW NON-INSULATED DUCT TYPE # FIRE NTS PROTECTION FOR CEILING OUTLETS DESIGNER NOTES: 1.SHOW LOCATION ON FLOOR PLANS DETAIL TITLE / FIRE PROTECTION FOR CEILING OUTLETS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230711-01.DWG

1/2" [15mm] STEEL PIPE OR STEEL TUBING TO SENSORS DIFFERENTIAL PRESSURE TRANSMITTER (FLOW, LEVEL) PT BLOWDOWN ELEVATION NOTES: 1. INSTALLATION OF SENSORS AND TRANSMITTERS SHALL CONFORM TO RECOMMENDATIONS OF MANUFACTURERS OF TRANSMITTERS. # PRESSURE TRANSMITTER INSTALLATION NTS DETAIL TITLE / PRESSURE TRANSMITTER INSTALLATION SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230911-01.DWG

BYPASS CW OR SW N.C. WATER METER 80 MESH STRAINER SUPPORT BRACKET ANCHORED TO WALL OR COLUMN 3'-6" [1.1M] FLOOR ELEVATION # WATER METER INSTALLATION NTS DETAIL TITLE / WATER METER INSTALLATION SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230911-02.DWG

EXHAUST ZC ZC MINIMUM OUTSIDE AIR OUTSIDE AIR AIR D-3 D-4 D-1 ZC FT AFMD ZC D-2 DPS PRE- FILTER DPS AFTER - FILTER RETURN TT T-5 MPS FAN COIL PREHEAT TT T4 COMM AIA TSL TSL-1 TRANSMITTER FAN STATUS SPD SUPPLY FAN TT CURRENT VFD COIL COOLING FOR,TYP. CS HS SST TT T-3 T-6 HT H-1 VFD AFMD FT DIFFUSER SECTION PRESSURE SWITCH LOW TO DISABLE RETURN FAN WHEN SMOKE DAMPER IN RETURN DUCT CLOSES CS IT HS PSL TT T-1 SD FINAL FILTER SST SD DPS RETURN AIR PRESSURE SWITCH HIGH TO DISABLE FAN WHEN HIGH PRESSURE LIMIT SETPOINT IS REACHED SD SMOKE DETECTOR PSH SD AFMD FT V-3 10' MIN. [3000mm] 2C SUPPLY AIR TO HT TERMINAL UNIT HHL SPS DETAIL TITLE / VARIABLE AIR VOLUME AIR HANDLING UNIT WITH MINIMUM OUTSIDE AIR CONTROL DIAGRAM NONE SCALE : DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD230923-04.DWG TT T-2 LOCATE SENSOR HOT GLYCOL WATER, HOT WATER OR ELECTRIC COILS ARE PERMISSIBLE V-2 V-1 SPD CHS CHR VARIABLE DRIVE, TYP. FREQUENCY ONLY WHERE REQUIRED 2C LPS STEAM HUMIDIFIER V-4 OUTSIDE UNDER SUBSTITUTES SHIELD # VARIABLE AIR VOLUME AIR HANDLING UNIT WITH MINIMUM OUTSIDE AIR CONTROL DIAGRAM NTS

ROOM EXHAUST FAN ELECTRIC UNIT HEATER D1 PLENUM T T T INTAKE LOUVER EXHAUST LOUVERS D2 FLEXIBLE T-1 CONNECTION T-2 T-3 EMERGENCY GENERATOR ACD NOTES: 1. EMERGENCY GENERATOR SHALL BE INTERLOCKED WITH D3. WHEN EMERGENCY GENERATOR IS ENERGIZED D3 SHALL OPEN. WHEN EMERGENCY GENERATOR IS DE-ENERGIZED D3 SHALL CLOSE, PROVIDED ROOM EXHAUST FAN IS OFF. 2. ROOM EXHAUST FAN SHALL BE INTERLOCKED WITH D3 & ROOM THERMOSTAT T1. WHEN ROOM THERMOSTAT RISES ABOVE 85 F [29 C] ROOM EXHAUST FAN SHALL RUN & D3 SHALL OPEN. WHEN ROOM THERMOSTAT DROPS BELOW 80 F [27 C] ROOM EXHAUST FAN SHALL STOP & D3 SHALL CLOSE, PROVIDED EMERGENCY GENERATOR IS DE-ENERGIZED. 3. POWER OPERATED, OPPOSED BLADE, DAMPERS D1 & D2 SHALL BE INTERLOCKED WITH ROOM THERMOSTAT T2 SET AT 60 F [16 C]. ON A RISE IN ROOM TEMPERATURE ABOVE 60 F [16 C] D1 SHALL MODULATE OPEN & D2 SHALL MODULATE CLOSED. ON A DROP IN ROOM TEMPERATURE BELOW 60 F [16 C], D1 SHALL MODULATE CLOSED & D2 SHALL MODULATE OPEN. 4. ELECTRIC UNIT HEATER SHALL BE INTERLOCKED WITH ROOM THERMOSTAT T3 SET AT 45 F [7.2 C]. ON A DROP IN ROOM TEMPERATURE BELOW 43 F [6.1 C] ELECTRIC UNIT HEATER SHALL BE ENERGIZED & ON A RISE IN ROOM TEMPERATURE ABOVE 47 F [8.3 C]. # EMERGENCY NTS GENERATOR ROOM CONTROLS DESIGNER'S NOTES: 1. IF THE PROJECT INVOLVES MULTIPLE EMERGENCY GENERATORS, EACH GENERATOR SHALL HAVE A DEDICATED SECTION OF THE OUTSIDE AIR INTAKE LOUVER & DAMPER MOTOR(S) ASSIGNED TO IT. THE DESIGNER SHALL SHOW A SCHEDULE OF THE EMERGENCY GENERATORS & THE SPECIFIC INTERLOCKED LOUVER/DAMPER SECTIONS ON THE FLOOR PLANS. 2. WHEN THE ROOM EXHAUST FAN IS RUNNING ALONE, WITHOUT ANY EMERGENCY GENERATOR, ONLY A DESIGNATED PORTION OF THE OUTSIDE AIR INTAKE LOUVER SHALL OPEN. THE DESIGNER SHALL SHOW THIS SECTION ON THE FLOOR PLANS. DETAIL TITLE / EMERGENCY GENERATOR ROOM CONTROLS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230923-07.DWG

2 POSITION M HOIST WAY VENT LOUVERS AT WALL OR ROOF HOIST WAY VENT DAMPER TWO POSITION, N.O. SPACE SMOKE DETECTOR* LOCATED AT TOP OF HOISTWAY TO LOCAL 120 V POWER TO FIRE ALARM CONTROL PANEL (FACP)* SD TO FIRE ALARM* & INITIATE PHASE 1 RECALL *BY ELECTRICAL ECC NOTES: 1. THE DAMPER SHALL REMAIN CLOSED DURING NORMAL OPERATION AND OPEN UPON LOSS OF POWER FROM A SIGNAL FROM THE SMOKE DETECTOR, LOCATED AT THE TOP OF THE HOISTWAY. COORDINATE NUMBER OF CONTACTS WITH THE ELECTRICAL AND FIRE PROTECTION DESIGNS. 2. SHOW DAMPER LOCATION AND SIZE ON THE DRAWINGS. 3. PROVIDE A BINARY DDC POINT TO SOUND AN ALARM AT ECC. 4. REMOTE ALARM SHALL BE ACTIVATED WHEN THE HOISTWAY SMOKE DETECTOR DETECTS SMOKE. HOISTWAY VENT DAMPER (HVD) # CONTROLS NTS DESIGNER'S NOTES: 1. THE AREA OF VENTS SHALL NOT BE LESS THAN 3.0% OF THE TOTAL HOISTWAY AREA OR 3 SQUARE FEET (0.28 SQUARE METERS) FOR EACH ELEVATOR CAR, WHICHEVER IS GREATER. DETAIL TITLE / HOISTWAY VENT DAMPER (HVD) CONTROLS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230923-08.DWG

SMOKE PARTITION DUCT TRANSITION AS REQUIRED SMOKE DAMPER (N.C.) SEE SCHEDULE SD AIRFLOW AIR DUCT AD TO FIRE ALARM CONTROL PANEL (FACP) PSH ZS M 2 POSITION BINARY POINT DAMPER POSITION FEEDBACK TO ECC 120V ELECTRICAL POWER PRESSURE SWITCH HIGH TO SHUT DOWN FAN UPON REACHING HIGH PRESSURE SETPOINT NOTE: UPON DETECTION OF SMOKE BY THE SMOKE DETECTOR, THE SMOKE DAMPER CLOSE & SEND AN ALARM TO THE ECC. SHALL # SMOKE DAMPER CONTROL DIAGRAM NTS DESIGNER'S NOTE: PROVIDE A DAMPER AND DETECTOR ONLY FOR PARTIALLY SPRINKLERED BUILDINGS WHEN EITHER SIDE OF SMOKE PARTITION IS NOT SPRINKLED AND PROTECTED BY QUICK RESPONSE SPRINKLER HEADS. DETAIL TITLE / SMOKE DAMPER CONTROL DIAGRAM SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD230923-09.DWG

NOTE: THIS DETAIL SHOWS BASIC REQUIREMENTS ONLY AND IS NOT INTENDED FOR USE ON PROJECT DRAWINGS. THE PROJECT ENGINEER MUST PROVIDE A COMPLETE DESIGN WHICH CONFORMS TO PROJECT VENT CAP GRADE 12" 12" [300mm] REQUIREMENTS. V [304mm] TANK 3" [76mm] MAXIMUM FOR HANGER WEAR SOIL PLATE 1/4" [6mm] THICK, 12" [304mm] SQ STEEL (TYP.) SEPARATOR ACCESS SOUNDING FOR COVER SEALED WATER TIGHT 42" [1067mm] DIA. MANWAY ENCLOSURE SEALED WATER TIGHT (TYP.) 2" [51mm] FILL CAP FOR SOUNDING TANK 22" [559mm] DIA. MANWAY (TYPICAL) ROD 12" [300mm] LADDER 6" [150mm] FOS GAGE FILL GRAVEL (ALL AROUND) CONCRETE (SQUARE) INTEGRAL DRAIN VALVE WITH FULL SIZE DISCHARGE CONNECTED TO FILL LINE FILL PIPE REINFORCED CONCRETE SLAB MANHOLE COVER LEAK DETECTOR SENSOR OVERFILL PREVENT VALVE FOOT 6" [150mm] 12" [300mm] ON VALVE ELEVATION FILL CAP 8" [200mm] GRADE 3" [75mm] #4 REBAR TOP AND BOTTOM FILL BOX - SPILL CONTAINER TYPE COMPRESSED FOAM BOARD SECONDARY CONTAINMENT TYPICAL PIPE HOLD-DOWN STRAPS TURN-BUCKLE DETAIL TITLE / UNDERGROUND FUEL OIL STORAGE TANK NONE SCALE : DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD231000-01.DWG BEDDING MATERIAL SIDE ELEVATION REINFORCED CONCRETE BALLAST PAD DESIGN FOR BUOYANCY OF EMPTY TANK WITH CREDIT FOR BACKFILL UNDERGROUND FUEL OIL LEAK DETECTOR SENSOR FOR - DOUBLE WALL TANK LADDER STEEL OR ALUMINUM 2 1/2" [64mm] WIDE STRINGERS 3/4" [19mm] DIA. RUNGS ANCHOR AT BOTTOM GUIDE AT TOP END ELEVATION 6" [150mm] 12" [300mm] # STORAGE TANK NTS

TYPICAL WATER PIPING REDUCER, IF REQUIRED 3/4" [20mm] BALL VALVE ADAPTER TO 3/4" [20mm] HOSE THREAD-PROVIDE HOSE CAP NUT ELEVATION THREADED PIPING ELEVATION WELDED PIPING TYPICAL CHILLED AND HOT WATER PIPING DRAIN VALVE CONNECTIONS NOTES: 1. DRAIN ALL LOW POINTS AS INDICATED ABOVE. 2. WHERE SCALE POCKETS ARE SHOWN ON PIPE RISER DIAGRAMS AND/OR PLANS LOCATE DRAIN AT BOTTOM OF SCALE POCKET. DESIGNER'S NOTE: SHOW SCALE POCKETS ON MAJOR CIRCULATING WATER PIPING RISER DIAGRAMS AND/OR PLANS. AIR VENT 1/2" [15mm] BALL VALVE MV OR AV 1/4" [8mm] COPPER TUBING 1/2" [15mm] x 4" [100mm] NIPPLE CIRCULATING WATER PIPING ELEVATION TYPICAL MANUAL AIR VENT NOTES: 1. VENT ALL HIGH POINTS INDICATED ABOVE. 2. IF AUTOMATIC AIR VENTS ARE USED, PIPE DISCHARGE TO DRAIN. # DRAIN VALVE AND AIR VENT CONNECTIONS (HYDRONIC SYSTEMS) NTS DETAIL TITLE / (HYDRONIC SYSTEMS) DRAIN VALVE AND AIR VENT CONNECTIONS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232113-07.DWG

DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN PIPING SHALL BE RIGID COPPER TYPE L OR TYPE M UNLESS NOTE BELOW IS MET PITCH DOWN TOWARD DRAIN CLEAN OUT A DRAIN PAN 1" [25mm] B DIELECTRIC FITTING FLOOR SINK NOTE: 1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY LOCAL VA AND IS INDOORS AND DOES NOT PASS THROUGH RATED BARRIERS. 2. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS ARE TO BE CONNECTED. UNIT TYPE A B DRAW THRU BLOW THRU 2" [50mm] PLUS X 1" [25mm] MINIMUM X 2X # AIR HANDLING UNIT DRAIN TRAP DETAIL NTS WHERE X = STATIC PRESSURE IN PAN DETAIL TITLE / AIR HANDLING UNIT DRAIN TRAP DETAIL SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD232113-08.DWG

W LONG RADIUS ELBOW (TYPICAL) PIPE ALIGNMENT GUIDES (TYPICAL) H SUPPLY W + 25 FT. [7.6m] APPROXIMATE MINIMUM RETURN PLAN EXPANSION LOOP LOOP NO. W H 100-ELI --- --- --- --- --- EXPANSION LOOP DETAIL # EXPANSION LOOP DETAIL NTS DETAIL TITLE / EXPANSION LOOP DETAIL SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232113-09.DWG

MANUAL AIR VENT TEST PLUG (TYP.) UNION CONNECTIONS (TYP.) MV REDUCER, IF REQUIRED SHUT OFF VALVE WATER RETURN MODULATION CONTROL VALVE COIL WATER SUPPLY DRAIN WITH HOSE CONNECTION # TERMINAL UNIT WATER COILS - PIPING CONNECTIONS NTS DESIGNER'S NOTE: 1. THIS DETAIL IS APPLICABLE TO: 2-PIPE FAN COIL UNITS (CHILLED OR HOT WATER) VAV/CV AIR TERMINAL UNITS ( REHEAT COIL) DUCT-MOUNTED REHEAT COIL CABINET UNIT HEATERS DETAIL TITLE / TERMINAL UNIT WATER COILS - PIPING CONNECTIONS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD232113-12.DWG

PLUG 1 1/2" [40mm] FULL PORT BALL VALVE 1 1/2" x2" LONG [40x50mm] PIPE 90 1 1/2" [40mm] FULL PORT BALL VALVE PLUG WELD (TYP) NOTE: 1. PROVIDE IN CHILLED WATER MAIN AND IN CONDENSER WATER MAIN. 2. LOCATE PILOT TUBE TAPS 20 PIPE DIAMETERS DOWNSTREAM AND 10 PIPE DIAMETERS UPSTREAM FROM THE NEAREST PIPE FITTING. EITHER TOP OR SIDE LOCATION. BOTH ARE NOT REQUIRED AT SAME LOCATION. # PITOT TEST CONNECTIONS NTS DESIGNER'S NOTE: SHOW LOCATION OF PILOT TEST CONNECTIONS ON FLOOR PLANS FOR CONDENSER WATER PIPING TO COOLING TOWER. THIS IS REQUIRED FOR FLOW MEASUREMENT BY ASME COOLING TOWERS TEST CODE. DETAIL TITLE / PITOT TEST CONNECTIONS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD232113-13.DWG

PIPE HANGERS - PROVIDE DOUBLE DEFLECTION NEOPRENE (TYPE HN) FOR FIRST TWO ON EACH SIDE OF PUMP (SEE NOTE NO. 1) PRESSURE GAGE BALANCING DEVICE 1/2" [15mm] FLEXIBLE CONNECTION STRAINER BALL OR BUTTERFLY TYP. NOTES: 1. SUPPORT PUMP FROM PIPING ONLY. DO NOT SUPPORT PUMP FROM MOTOR. # IN-LINE PUMPS - CONNECTIONS NTS DESIGNER'S NOTE: 1. CHECK VALVE IS OPTIONAL FOR SINGLE PUMP, EXCEPT FOR COOLING TOWER PUMP. 2. ELIMINATE BALANCING DEVICE WHEN PUMP CONTROLLED BY VARIABLE SPEED DRIVE. DETAIL TITLE / IN-LINE PUMPS - CONNECTIONS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232123-01.DWG

FIRST 3 HANGERS FOR EACH PIPE AND BRANCH SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 4" [100mm] DIA. PIPE & SMALLER. TYPE "H-P" FOR 5" [125mm] DIA. PIPE & LARGER. RIGID PIPE HANGER RIGID HANGER PIPE INSTALL HANGER AS CLOSE TO PIPE ELBOW AS POSSIBLE (TYPICAL) BUTTERFLY OR BALL SHUT OFF VALVE, TYP. OPTIONAL STRAINER CHECK VALVE 1/2" [15mm] PRESSURE GAUGE 1/2" [15mm] FLEXIBLE PUMP FLOOR CONNECTOR (TYPICAL) SUCTION DIFFUSER WITH BUILT IN STRAINER. OPTIONAL: LONG RADIUS ELBOW AND INLET STRAINER WITH 3XDIAM STRAIGHT INLET TO PUMP DRAIN VIBRATION (TYPICAL) ISOLATOR CONCRETE INERTIA BASE NOTES: SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION 1" [25mm] MIN. DIA. PIPE STAND SINGLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH FLEXIBLE CONNECTORS # NTS DESIGNER'S NOTE: CHECK VALVE IS OPTIONAL FOR SINGLE PUMP, EXCEPT FOR COOLING TOWER PUMP. DETAIL TITLE / SINGLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH FLEXIBLE CONNECTORS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232123-02.DWG

FIRST 3 HANGERS FOR EACH PIPE AND BRANCH SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 4" [100mm] DIA. PIPE & SMALLER. TYPE "H-P" FOR 5" [125mm] DIA. PIPE & LARGER. RIGID PIPE HANGER INSTALL HANGER AS CLOSE TO PIPE ELBOW AS POSSIBLE (TYPICAL) RIGID PIPE HANGER BUTTERFLY OR BALL SHUT OFF VALVE, TYP. OPTIONAL STRAINER PRESSURE GAGE 1/2" [15mm] MECHANICAL COUPLING (6" MIN.[150 MM] SPACING) (TYPICAL) PUMP FLOOR 1/2" [15mm] SUCTION WITH DRAIN DIFFUSER BUILT IN STRAINER. OPTIONAL: LONG ELBOW AND INLET 1" [25mm] MIN. DIA. PIPE STAND RADIUS STRAINER WITH 3XDIAM STRAIGHT INLET TO PUMP NOTES: SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION CONCRETE BASE (SEE DETAIL) # SINGLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH MECHANICAL COUPLINGS NTS DESIGNER'S NOTE: 1. CHECK VALVE IS OPTIONAL FOR SINGLE PUMP, EXCEPT FOR COOLING TOWER PUMP. USE THIS DETAIL ONLY FOR PUMPS IN A MECHANICAL BUILDING WHERE POSSIBLE VIBRATION WILL NOT BE OBJECTIONABLE AND WHERE APPROVED BY VA. 2. COUPLINGS SHALL NOT BE USED ON HOT WATER SYSTEMS. DETAIL TITLE / SINGLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH MECHANICAL COUPLINGS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232123-03.DWG

FIRST 3 HANGERS FOR EACH PIPE AND BRANCH SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 4" [100mm] DIA. PIPE AND SMALLER. TYPE "H-P" FOR 5" [125mm] DIA. PIPE AND LARGER. RIGID PIPE HANGER (TYPICAL) INSTALL HANGER AS CLOSE TO PIPE ELBOW AS POSSIBLE (TYPICAL) OPTIONAL STRAINER BUTTER OR BALL SHUT OFF VALVE, CHECK VALVE TYP. 1/2" [15mm] PRESSURE GAUGE FLEXIBLE CONNECTOR FLEXIBLE CONNECTOR SUCTION DIFFUSER WITH BUILT-IN STRAINER DRAIN PUMP 1" [25mm] MIN. DIA. PIPE STAND FLOOR 1" [25mm] MIN. DIA. PIPE STAND CONCRETE INERTIA BASE (SEE DETAIL) VIBRATION ISOLATOR (TYPICAL) NOTE: SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION. DESIGNER'S NOTE: CHECK VALVE IS OPTIONAL FOR SINGLE PUMPS, EXCEPT FOR COOLING TOWER PUMP. # DOUBLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH FLEXIBLE CONNECTORS NTS DETAIL TITLE / DOUBLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH FLEXIBLE CONNECTORS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232123-04.DWG

FIRST 3 HANGERS FOR EACH PIPE AND BRANCH SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 4" [100mm] DIA. PIPE AND SMALLER. TYPE "H-P" FOR 5" [125mm] DIA. PIPE AND LARGER. RIGID PIPE HANGER (TYPICAL) INSTALL HANGER AS CLOSE TO PIPE ELBOW AS POSSIBLE (TYPICAL) BUTTER OR BALL SHUT OFF VALVE, CHECK VALVE TYP. OPTIONAL STRAINER PRESSURE GAGE 1/2" [15mm] MECHANICAL COUPLINGS (6" [150mm] MIN. SPACING) (TYPICAL) SUCTION DIFFUSER WITH BUILT-IN STRAINER PUMP DRAIN FLOOR 1" [25mm] MIN. DIA. PIPE STAND CONCRETE BASE (SEE DETAIL) NOTES: SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION. # DOUBLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH MECHANICAL COUPLINGS NTS DESIGNER'S NOTE: 1. CHECK VALVE IS OPTIONAL FOR SINGLE PUMP EXCEPT FOR COOLING TOWER PUMP. USE THIS DETAIL ONLY FOR PUMPS IN A MECHANICAL BUILDING WHERE POSSIBLE VIBRATION WILL NOT BE OBJECTIONABLE AND WHERE APPROVED BY VA. 2. COUPLINGS SHALL NOT BE USED IN HOT WATER APPLICATIONS. DETAIL TITLE / DOUBLE SUCTION FLOOR-MOUNTED PUMPS - CONNECTIONS WITH MECHANICAL COUPLINGS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232123-05.DWG

FIRST 3 HANGERS FOR EACH PIPE AND BRANCH SHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR 4" [100mm] DIA. PIPE AND SMALLER. TYPE "H-P" FOR 5" [125mm] DIA. PIPE AND LARGER. RIGID PIPE HANGER (TYPICAL) AV AV INSTALL HANGER AS CLOSE TO PIPE ELBOW AS POSSIBLE (TYPICAL) STRAINER BUTTER OR BALL SHUT OFF VALVE, TYP. NON SLAM CHECK VALVE WITH COUNTER WEIGHT PRESSURE GAGE 1/2" [15mm] ECCENTRIC REDUCER INLET TO PUMP SHALL BE MINIMUM OF 3 PIPE DIAMETERS FLEXIBLE CONNECTOR TYP. PUMP NOTE 3 FLOOR 1" [25mm] MIN. DIA. PIPE STAND CONCRETE BASE (SEE 1. Y TYPE STRAINER BLOWDOWN HEIGHT SHALL ACCOMMODATE 55 GALLON DRUM. DETAIL) 2. PUMP INSTALLATION IS DIAGRAMMATIC AND INTENDED TO SHOW THE MAJOR COMPONENTS REQUIRED FOR INSTALLATION. THE INSTALLED PIPING CONFIGURATION SHALL BE BASED ON THE ACTUAL PUMP PROVIDED. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL A COORDINATION DRAWING SHOWING PUMP, PIPING, AND ACCESSORIES AS REQUIRED BY THIS INSTALLATION DETAIL. 3. ALL PAD, PUMP, AND PIPING DRAINS SHALL BE HARD PIPED TO NEAREST FLOOR DRAIN, TYPICAL. # HORIZONTAL SPLIT CASE PUMP - FLEXIBLE CONNECTORS NTS DESIGNER'S NOTE: CHECK VALVE IS OPTIONAL FOR SINGLE PUMP EXCEPT FOR COOLING TOWER PUMP. USE THIS DETAIL ONLY FOR PUMPS IN A MECHANICAL BUILDING WHERE POSSIBLE VIBRATION WILL NOT BE OBJECTIONABLE OR WHERE APPROVED BY VA. DETAIL TITLE / HORIZONTAL SPLIT CASE PUMP - FLEXIBLE CONNECTORS SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD232123-06.DWG

FROM PUMP DISCHARGE NOTE: 1. SIZE WATER FILTER FOR 5% OF TOTAL SYSTEM FLOW PRESSURE GAUGE 1/2" [15mm] TO PUMP SUCTION AUTOMATIC FLOW CONTROL DEVICE SEE NOTE 2 WATER FILTER LOW POINT DRAIN DRAIN CONNECTION # WATER FILTERS - CLOSED LOOP HYDRONIC SYSTEMS NTS DESIGNER'S NOTE: 1. PROVIDE SEDIMENT WATER FILTER ON EACH CHILLED WATER, HOT WATER AND GLYCOL WATER HEATING SYSTEM. CAPACITY SHALL BE APPROXIMATELY 5% OF THE TOTAL CIRCULATING FLOW. SHOW FILTER LOCATIONS ON THE DRAWINGS. INCLUDE THE FILTER FLOW RATE IN PUMP CAPACITIES. SIZE PIPES TO WATER FILTER. 2. SELECT PRESSURE RANGE PER PROJECT NEED. SPECIFY PRESSURE RANGE ON DRAWINGS. DETAIL TITLE / WATER FILTERS - CLOSED LOOP HYDRONIC SYSTEMS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD232500-01.DWG

AUTOMATIC FLOW CONTROL AND BALANCE DEVICE 1" [25mm] CHEMICAL POT FEEDER- MINIMUM CAPACITY 5 GALLONS [19L] FUNNEL 3/4" [20mm] 1" [25mm] TO DRAIN FROM PUMP DISCHARGE TO PUMP SUCTION NOTE: TOP OF CHEMICAL POT FEEDER TANK SHALL NOT BE MORE THAN 4'-0" [1200mm] ABOVE FINISHED FLOOR. # WATER TREATMENT - CLOSED SYSTEMS NTS DESIGNER'S NOTE: 1. SHOW LOCATION OF ALL CHEMICAL POT FEEDER TANKS ON PIPING DIAGRAMS FOR EACH CHILLED WATER AND HEATING HOT WATER SYSTEM. FEEDER MAY ALSO BE USED FOR MAKE-UP FOR SMALL GLYCOL-WATER SYSTEMS (UNDER 50 GPM [190 LPM] IN LIEU OF A TANK/PUMP MAKE-UP SYSTEM. DETAIL TITLE / WATER TREATMENT - CLOSED SYSTEMS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD232500-02.DWG

~ CHILLED WATER RETURN HEADER ~ LC WATER LEVEL TOWER TOWER TOWER SD232500-03.DWG CAD DETAIL NO.: REDUCED PRESSURE BACK FLOW CONDENSER WATER SUPPLY (FROM TOWER) PREVENTER SIDE STREAM SOLID RELIEF BYPASS VALVE TYP. ~ CHEMICAL FEED PUMP NO. 1 HS CHEMICAL FEED PUMP NO. 2 HS DCW SEE PLUMBING DWG MODULATING LEVEL CONTROL VALVE CHEMICAL FEED PUMP NO. 3 HS CT PHT CHEMICAL FEED CONTROLLER M MAKE METER UP PH TRANSMITTER SAMPLE CONDUCTIVITY TRANSMITTER OPTIONAL SIDE STREAM SEPARATOR TYP. SEPARATOR WITH PUMP CONDENSERS PUMP TYP. CONDENSERS TYP. DETAIL TITLE / WATER TREATMENT SYSTEM - COOLING TOWER NONE SCALE : DECEMBER 2008 DATE ISSUED: CONDENSER WATER RETURN (TO TOWER) STORAGE TANK NO. 1 CHILLED WATER SCALE AND CORROSION INHIBITOR STORAGE TANK NO. 2 TOWER BIOCIDE STORAGE TANK NO. 3 TOWER SCALE AND CORROSION INHIBITOR STORAGE TANK NO. 4 BROMINE FEEDER M DESIGNERS NOTES: 1.DESIGN WATER TREATMENT SYSTEM BASED ON THE AVAILABLE WATER SAMPLE ANALYSIS AND RECOMMENDATIONS OF THE WATER TREATMENT CONSULTANT. # WATER TREATMENT SYSTEM - COOLING NTS TOWER FLOOR SINK BLOW DOWN VALVE METER 2.PROVIDE INTERFACE BETWEEN CHEMICAL FEED CONTROLLER AND ECC. 3.CHILLED WATER WATER TREATMENT SYSTEM SHALL BE OPERATED MANUALLY. 4.ADDITIONAL STORAGE TANKS AND FEED PUMPS MAY BE REQUIRED BASED ON THE OUTCOME OF THE WATER SAMPLE ANALYSIS. 5.ENSURE CLOSE COORDINATION BETWEEN THE CONTRACT SPECIFICATIONS AND DETAILS.

CONDENSER WATER PUMP CONDENSER CWS SIDESTREAM SEPARATOR SOLIDS RECOVERY SEPARATOR CWS CWS SEE PUMP SCHEDULE AND DETAIL SIDESTREAM SEPARATOR SOLIDS RECOVERY SEPARATOR CWS FD FD SEPARATOR DETAIL WITHOUT SIDESTREAM PUMP SEPARATOR DETAIL WITH SIDESTREAM PUMP DESIGNER'S NOTE: 1. PROVIDE EITHER A COMMON SIDESTREAM SOLID SEPARATOR WITH PUMP OR A DEDICATED SEPARATOR FOR EACH CONDENSER WATER SYSTEM. 2. INCREASE CONDENSER WATER PUMP CAPACITY 5%-8% FOR A DEDICATED SIDESTREAM SEPARATOR. # SIDESTREAM SOLID SEPARATOR NTS DETAIL TITLE / SIDE STREAM SOLID SEPARATOR SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD232500-04.DWG

W2 W1 NOTE: 1. ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA. 2. WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE REGARDLESS OF W DIMENSION. TYPE 3. 4. ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE. WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE. # DUCTWORK SQUARE VANE ELBOWS NTS DETAIL TITLE / DUCTWORK SQUARE VANED ELBOWS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-01.DWG

# R SHALL EQUAL OR BE GREATER THAN W. VANE R SHALL EQUAL OR BE GREATER THAN 1/3W VANE W R R 2/3W 1/3W. 1/6W R SHALL EQUAL OR BE GREATER THAN 1/3W 1/2W R 1/6W. STANDARD RADIUS OR LONG RADIUS ELBOW W W NOTE: SHORT RADIUS ELBOW WITH ONE VANE SHORT RADIUS ELBOW WITH TWO VANES 1. THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND. 2. ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA. DUCTWORK RADIUS ELBOWS NTS DESIGNER'S NOTE: DO NOT SHOW MITERED ELBOWS AND MITERED OFFSETS (TRANSITIONS) GREATER THAN 15 DEGREES ON DRAWINGS. DETAIL TITLE / DUCTWORK RADIUS ELBOWS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-02.DWG

MAX. MAX. 30 EQUIPMENT 15 MAX. 15 AIR FLOW AIR FLOW MAX. 15 15 MAX. 30 MAX. TYPICAL DUCTWORK TRANSITION WITH EQUIPMENT MOUNTED IN DUCT PLAN OR SIDE VIEW TYPICAL DUCTWORK TRANSITION PLAN OR SIDE VIEW NOTE: UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY. # DUCTWORK TRANSITIONS (WITH EQUIPMENT MOUNTED IN DUCT) NTS DETAIL TITLE / DUCTWORK TRANSITIONS (WITH EQUIPMENT MOUNTED IN DUCT) SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-03.DWG

TURNING VANES SEE FLOOR PLAN FOR SPLIT DIMENSION VOLUME EXTRACTOR; ADJUSTABLE FROM FULLY CLOSED POSITION TO CFM NOTED ON FLOOR PLANS ADJUSTABLE METAL ROD OR LINKAGE MAIN SUPPLY DUCT AIR FLOW AIR FLOW AIR FLOW AIR FLOW PROVIDE VOLUME DAMPER MAIN SUPPLY DUCT TOP REGISTER AIR SUPPLY REGISTER TAKE-OFF PLAN VIEW FLOW SUPPLY REGISTER OR BRANCH DUCT AIR SPLIT DUCT TAKE-OFF PLAN VIEW AIR FLOW 1/4 W OR 4" [100mm] MIN. MAIN SUPPLY DUCT PROVIDE VOLUME AIR FLOW DAMPER W # SUPPLY DUCTWORK TAKE-OFFS NTS DESIGNER'S NOTES: BRANCH DUCT TAKE-OFF PLAN VIEW 1. THE SUPPLY REGISTER TAKE-OFF MAY BE USED FOR UP UP TO 25% OF THE MAIN DUCT CFM. THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15% OF THE MAIN DUCT CFM ANYTIME AND UP TO 40% WHEN THE MAIN DUCT VELOCITY IS 1000 FPM [5.1 M/S] OR LESS. THE AIR SPLIT DUCT TAKE-OFF SHALL BE USED IN ALL OTHER CASES AND MAY BE USED AT ANYTIME. 2. SHOW ALL VOLUME DAMPERS ON FLOOR PLANS. DETAIL TITLE / SUPPLY DUCTWORK TAKE-OFFS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-04.DWG

MAIN SUPPLY 45 MAX. "D" ROUND SHEET METAL DUCT. RIGID DUCT TO AIR TERMINAL UNIT. PLAN VIEW # SUPPLY DUCT NTS TAKEOFF - AIR TERMINAL UNIT DETAIL TITLE / SUPPLY DUCT TAKEOFF- AIR TERMINAL UNITS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-05.DWG

MAIN SUPPLY FLOW FLOW SMACNA FIGURE 4-6 45 LEED IN RIGID DUCT TO AIR TERMINAL UNIT. PLAN VIEW # ALTERNATE SUPPLY DUCT TAKEOFF - AIR TERMINAL UNITS NTS DETAIL TITLE / ALTERNATE SUPPLY DUCT TAKEOFF - AIR TERMINAL UNITS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-06.DWG

AIR FLOW MAIN EXHAUST OR RETURN AIR FLOW BRANCH DUCT VD 1/4W OR 4" [100mm] MIN. PROVIDE VOLUME DAMPER AT EACH BRANCH DUCT W PLAN VIEW # EXHAUST OR RETURN BRANCH DUCTWORK NTS DESIGNER'S NOTE: 1. SHOW ALL VOLUME DAMPERS ON FLOOR PLANS. DETAIL TITLE / EXHAUST OR RETURN BRANCH DUCTWORK SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-07.DWG

STIFFEN BLADE AS REQUIRED INSULATION SEE SPECIFICATION DUCT INSULATION STAND-OFF 1/2" [15mm] ROUND ROD PIN OUTSIDE END BEARING DAMPER BLADE HANDLE WITH LOCKING QUADRANT INSIDE END BEARING 1/8" [6mm] CLEARANCE SIDE ELEVATION ALL AROUND SECTION NOTE: 1. DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION. 2. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI-BLADE DAMPERS & ROUND DAMPERS. # VOLUME DAMPER DETAIL NTS DETAIL TITLE / VOLUME DAMPER DETAIL SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-08.DWG

"A" "A" INSULATION DUCT GASKET INSULATION SECTION "A-A" ACCESS PANEL CASING GASKET HANDLE INSIDE "B" "B" NOTES: 1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY. 2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS. 3. SEE SMACNA 2005, FIGURE 9-15 INSULATION ACCESS DOOR SECTION "B-B" FLEXIBLE WASHER FACTORY FABRICATED LATCH # ACCESS NTS PANEL AND DOOR DETAIL DESIGNERS NOTES: 1. USE ACCESS DOORS ON AIR HANDLING UNITS AND DUCTWORK INSTALLED IN EQUIPMENT ROOMS. 2. USE ACCESS PANELS ON ALL EQUIPMENT AND DUCTWORK INSTALLED ABOVE FINISHED CEILINGS. DETAIL TITLE / ACCESS PANEL AND DOOR DETAIL SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD233100-09.DWG

HOUSING WELDED TO DUCT SECTION ROUND OR FLAT OVAL DUCT SECTION COVER WITH HANDLE AND CHAIN RETAINER GASKETED AND PRESSURE SEALED # ACCESS SECTION FOR ROUND/OVAL DUCT NTS DETAIL TITLE / ACCESS SECTION FOR ROUND/OVAL DUCT SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-10.DWG

ALTERNATE POSITION 1" [25mm] FLANGE & HEM OF BOLT BOLT ON 4" [100mm] CENTERS 1 1/2" [40mm] 1"x1/8" [25x3mm] BAND IRON FLEXIBLE MATERIAL AS SPECIFIED SHEET METAL AS SPECIFIED FOR DUCTWORK. POCKET SLIP DUCT WASHER FLANGED CONNECTION ON FAN SIDE SHEET METAL AS SPECIFIED FOR DUCTWORK. 1 1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6" [150mm] NOMINAL WITH MATERIAL TAUT RECTANGULAR FLEXIBLE CONNECTION 5/16" [8mm] FLANGE BOLT ON 4" [100mm] CENTERS 1"x1/8" [25x3mm] BAND IRON 1"x1/8" [25x3mm] DRAW BAND SHEET METAL SCREWS ON 12" [300mm] CENTERS FLEXIBLE MATERIAL AS SPECIFIED RIVET ON 4" [100mm] CENTERS DUCT 1/2" [15mm] WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] FLANGED CONNECTION MAX. INSTALLED. 6" [150mm] NOMINAL WITH MATERIAL TAUT ON FAN SIDE 1/2" [15mm] 1 1/2" [40mm] ROUND FLEXIBLE CONNECTION # FLEXIBLE DUCT CONNECTIONS NTS DETAIL TITLE / FLEXIBLE DUCT CONNECTIONS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-11.DWG

FIRE BARRIER PARTITION OR CHASE NOTE 6 SLEEVE, NOTE 2 TYPICAL DUCT INSULATION 1" [25mm] DAMPER COLLAR EXTENSION INTEGRAL PART OF SLEEVE DAMPER, NOTE 1 ACCESS PANEL NOTE 5 DUCT CONNECTION NOTE 4 PERIMETER ANGLE, NOTE 3 (NOTE FASTENED TO PARTITION) SLEEVE, NOTE 2 NOTE: 1. A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR. FOLLOW DAMPER MANUFACTURER'S INSTRUCTIONS, INCLUDING FASTENER OPTIONS AND GAGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUST BE INSTALLED IN THE PARTITION OR FLOOR AND NOT OUTSIDE THE PENETRATION. 2. 3. 4. 5. 6. 7. GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO DAMPER FRAME AND TO PERIMETER ANGLES. PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2" [40x40mm], 14 GAGE, TO PROVIDE 1" [25mm] MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES. BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA. ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR LINKS. PROVIDE 1/4" TO 1/2" [6 TO 15mm] CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN SPACE WITH ROCK WOOL FIRESTOP FIBER. ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS AND MECHANICAL ROOM FLOORS, SHALL BE PROVIDED WITH 3" [75mm] HIGH CONCRETE CURB AROUND OPENING FOR DUCT. # SECTION THRU FIRE DAMPER INSTALLATION NTS DETAIL TITLE / SECTION THRU FIRE DAMPER INSTALLATION SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-12.DWG

ALL THREAD ROD. MINIMUM 3/8" [10mm] INSULATION GALVANIZED ANGLE IRON OR EQUIVALENT STRENGTH CHANNEL NOTE: 1. PROVIDE BRACING TO LIMIT THE AMPLITUDE OF WALL VIBRATION AND WALL DEFLECTION TO SPECIFIED MAXIMUMS. 2. MINIMUM BRACING REQUIREMENTS: MAXIMUM DUCT WIDTH IN. [mm] UP TO 26 [650] 27 [675] TO 40 [1000] 41 [1000] TO 60 [1500] 61 [1500] TO 72 [1800] MAXIMUM SIZE ANGLE IN. [mm] NONE 1-1/2x1-1/2x3/16 [40x40x7] 2x2x3/16 [50x50x7] 2x2x3/16 [50x50x7] MAXIMUM IN. [mm] 72 [1800] 48 [1200] 24 [600] SPACING 3. INSULATION: FOR COLD DUCTS INSULATE BRACES AND PROVIDE VAPOR BARRIER. # FLAT OVAL DUCT HANGERS/REINFORCEMENT NTS DETAIL TITLE / FLAT OVAL DUCT HANGERS/REINFORCEMENT SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-13.DWG

LOAD RATED FASTENERS HANGER STRAPS OR RODS BAND OF SAME SIZE AS HANGER STRAP 50" [1250mm] & UNDER HANGER RODS MAX. DUCT Ø QUANTITY/SIZE IN. [mm] IN. [mm] 26 [650] 36 [900] ONE 1 [25] x 22 GA STRAP ONE 1 [25] x 18 GA STRAP 260 [119] 420 [190] 50 [1250] ONE 1 [25] x 16 GA STRAP 700 [317] 60 [1500] TWO 3/8 [10]Ø. RODS 1320 [598] 84 [2100] TWO 1/2 [13]Ø RODS MAX. LOAD LBS. [kg] 2500 [1133] NOTE: TABULATED DATA FROM SMACNA ALLOWS FOR DUCT REINFORCING AND INSULATION, BUT NO EXTERNAL LOAD. BAND OVER 50" [1250mm] # ROUND DUCT HANGERS NTS DESIGNER'S NOTE: DESCRIBE OR DETAIL UPPER ATTACHMENTS APPLICABLE TO PARTICULAR PROJECTS. MAX. SPACING IN. [mm] 144 [3600] 144 [3600] 144 [3600] 144 [3600] 144 [3600] DETAIL TITLE / ROUND DUCT HANGERS SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-14.DWG

DUCT RISER - SEE FLOOR PLANS FOR SIZES SHEET METAL SCREWS 4" EXTEND ANGLE 3" [75mm] BEYOND DUCT FLOOR [100mm] ON CENTER 1 1/2"x1 1/2"x1/8" [40x40x3mm] ANGLE INSTALL ON BOTH LONG DIMENSION SIDES OF DUCT. FOR DUCTS OVER 60" [1500mm] USE 2"x2"x1/8" [50x50x3mm] ANGLE. SEAL HOLE WITH FIREPROOFING MATERIAL AFTER DUCT INSTALLATION HOLE IN STRUCTURAL FLOOR DUCT RISER 0.5 INCH WG [125Pa] TO 2 INCHES WG [500Pa] DUCT RISER SUPPORT DUCT RISER - SEE FLOOR PLANS FOR DETAILS 2"x2"x1/4" [50x50x6mm] ANGLE INSTALL ON BOTH LONG DIMENSION SIDES OF DUCT. ARRANGE RISER SO REINFORCER TRANSVERSE JOINT IS AT RISER SUPPORT POINT FLOOR SEAL HOLE WITH FIREPROOFING MATERIAL AFTER DUCT INSTALLATION HOLE IN STRUCTURAL FLOOR DUCT RISER 2 INCHES WG [500Pa] TO 4 INCHES WG [1000Pa] DUCT RISER SUPPORT NOTE: ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS AND FAN ROOM FLOORS SHALL BE PROVIDED WITH A 3" [75mm] HIGH CONCRETE CURB AROUND OPENING FOR DUCT. # DUCT RISER SUPPORTS NTS DESIGNER'S NOTE: INDICATE ON DRAWING THE DUCT PRESSURE CLASS 2" WG [500Pa] WG, 3" [750Pa] OR 4" WG [100OPa]. DETAIL TITLE / DUCT RISER SUPPORTS WG SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-15.DWG

SIZE TO MAINTAIN 3500 FPM [17.8 M/S] OUTLET VELOCITY 15 WELDED STAINLESS STEEL EXHAUST 1" [25mm] GALVANIZED STEEL STRAP SECURED TO EXHAUST STACK GUY WIRE (4 REQUIRED) DRIP LIP STACK WELDED JOINT AS REQUIRED TRANSITION (AS REQUIRED) F.C. EXHAUST FAN DRAIN, 1/2" [15mm] WELDED 10'-0" MIN. [3000mm] COUPLING ROOF SECURE STACK TO ROOF (TYP.) BLANK PLATE SECURE GUY WIRE TO ROOF (TYP.) # EXHAUST STACK DETAIL NTS DESIGNER'S NOTE: 1. 10 FEET MINIMUM HEIGHT IS SHOWN. INCREASE THE HEIGHT, AS REQUIRED, TO COMPLY WITH THE RECOMMENDATIONS OF THE DISPERSION ANALYSIS. 2. USE THIS DETAIL FOR FUME HOODS,BIOLOGICAL SAFETY CABINETS, ISOLATION ROOM EXHAUST AND ANY OTHER APPLICABLE AREA. DETAIL TITLE / EXHAUST STACK DETAIL SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-16.DWG

CONNECT TO GENERAL EXHAUST EXHAUST DUCT CEILING CEILING REGISTER 2" [50mm] 50 CFM, 4" [100mm] DIA. STAINLESS STEEL DUCT PER MANUFACTURER'S RECOMMENDATION FILM PROCESSOR PROVIDE DUCT TRANSITION FITTING IF REQUIRED BETWEEN 4" AND FILM PROCESSOR NOTE: 1. USE THIS DETAIL ONLY IF THE FILM PROCESSING INVOLVES USE OF CHEMICALS. # DUCTWORK CONNECTION - FILM PROCESSOR NTS DETAIL TITLE / DUCTWORK CONNECTION - FILM PROCESSOR SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD233100-18.DWG

SUPPORT ANGLES OR STANDING "A" EXHAUST DUCT SEAMS SECURE TO STRUCTURE TO ABOVE AS RECOMMENDED BY SMACNA WIDTH SEE NOTE 1 "A" LENGTH PLAN HIGH CLG. - SEE NOTE 4 CLG. SUPPORT ANGLE-SEE ARCHITECTURAL SPECIFICATIONS "B" - NORMAL 9'-0" [2740mm] CLG. 32" [800mm] MIN. "B" SEE NOTE 2 FRONT ELEVATION 1" [25mm] 3/4" [20mm] LAP ALL AROUND MITER AND WELD CORNERS SEE NOTE 3 SECTION "A-A" CONTINUOUS WELD 1/2" [12.71mm] NOTES: 1. HOODS SHALL BE STAINLESS STEEL, SEE SPECIFICATIONS. FOR HOOD SIZE & LOCATION SEE EQUIPMENT SCHEDULE. FOR EXHAUST DUCT CONNECTIONS - SEE FLOOR PLANS. 1"x1/8"[25x6mm] STIFFENING BAR- SEE NOTE 3 SECTION "B-B" 3/4" [20mm] 2. ALL HOODS SHALL BE 6'-6" [2m] ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. HOODS OVER URNS SHALL BE 7'-6" [2.3m] MINIMUM ABOVE FINISHED FLOOR. 3. HOODS OVER 6'-0" [1.9m] LONG WITH 2 OR MORE SECTIONS, SHALL HAVE INSIDE STANDING SEAM AND 1"x1/8" [25x6mm] STIFFENING BAR - SEE SECTION "B-B". 4. EXTEND SIDE & END SHEET TO SUIT HIGH CEILING WHEN REQUIRED. 5. DETAIL SHOWS HOOD IN OPEN SPACE. WHEN HOOD IS INSTALLED AT WALL OR PARTITION SECURE TO WALL OR PARTITION WITH EXPANSION BOLTS. # HOOD TYPE "A" NTS DESIGNER'S NOTE: VERIFY ALL DIMENSIONS. SEE ARCHITECTURAL FLOOR PLANS FOR REQUIRED HOOD LOCATIONS. DETAIL TITLE / HOOD TYPE "A" SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD233100-19.DWG

TO DEDICATED EXHAUST SYSTEM "WET" EXHAUST DUCT (STAINLESS STEEL) MANUAL VOLUME DAMPER CEILING UNDUCTED WASHER EXHAUST VENT OPENING EXHAUST HOOD (TYPE "A") WALL 1'-0" [300mm] MIN. FRONT AND 6" [150mm] MIN. CLEARANCE ON BOTH SIDES WASHER DOOR GLASSWARE WASHER (SEE ARCHITECTURAL FLOOR PLANS) FLOOR 6'-0" [1800mm] MINIMUM-EXACT HEIGHT SHALL BE BASED ON EQUIPMENT FURNISHED # EXHAUST DUCTWORK- GLASSWARE WASHER NTS DESIGNER'S NOTES: 1. SEE VA STANDARD DETAIL 23 31 00-20 FOR CONSTRUCTION & INSTALLATION DETAILS. 2. COORDINATE HOOD DIMENSIONS AND EXHAUST AIR VOLUME SHOWN ON THE EQUIPMENT DRAWINGS. EXHAUST AIR VOLUME SHALL BE BASED ON THE 100 FPM [.5 M/sec] VELOCITY THRU THE FACE AREA OF THE HOOD. DETAIL TITLE / EXHAUST DUCTWORK - GLASSWARE WASHER SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD233100-21.DWG

OUTSIDE AIR LOUVER NOTE 2 NOTE:1 EXTERIOR WALL CMU WALL 4'-8" [1400mm] 24"x24" [600mmx600mm] BOLTED 1/2" [15mm] STEEL ACCESS PANEL FLOOR DRAIN (TYP.) OUTSIDE AIR DAMPER ACCESS (WALK-IN) SECTION DETAIL KEYNOTES: 1. THE DESIGN AND SUPPORTING DOCUMENTATION FOR THE BLAST RESISTANT CONCRETE WALL SHALL BE COORDINATED AND APPROVED BY A REGISTERED PROFESSIONAL STRUCTURAL ENGINEER SPECIALIZING IN BLAST RESISTANT CONSTRUCTION. 2. LIMIT AIR VELOCITY TO 800 FPM [4.0 m/s] THRU PLENUM. OUTSIDE AIR INTAKE FOR AIR HANDLER # UNIT FOR MISSION CRITICAL FACILITY NTS DETAIL TITLE / OUTSIDE AIR INTAKE FOR AIR HANDLER UNIT FOR MISSION CRITICAL FACILITY SCALE : NONE DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD233100-23.DWG

SEE SPECIFICATIONS FOR CLAMPS AND SEALANT (TYP.) SUPPORT SADDLE FROM STRUCTURE FLEXIBLE DUCT SIZE SAME AS DIFFUSER INLET: 5'-0" MAX LENGTH. THERMAL INSULATION SEE SPECIFICATIONS CONICAL OUTLET BRANCH DUCT USE RIGID ELBOWS FOR CHANGE OF DIRECTION GREATER THAN 45 12" [300mm] SHEET METAL SADDLE VOLUME DAMPER W/ LOCKING QUAD TYPICAL DIFFUSER OR REGISTER IN LAY-IN CLG. CEILING NOTE: THE USE OF FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FOR THE DEDICATED AHU SERVING THE SURGICAL SUITE. # FLEXIBLE AIR DUCT CONNECTOR NTS DETAIL TITLE / FLEXIBLE AIR DUCT CONNECTOR SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD233100-24.DWG

LOCATED IN OPERATING ROOM SURGICAL SUITE SUPPLY DIFFUSER SYSTEM ACCESS DOOR MIN.24x36 ELBOW HEPA FILTRATION AIR VELOCITY MAX. 400 FPM [2.0 M/sec] 4'-0" [1200mm] MIN. TU 2-POSITION TERMINAL UNIT WITH REHEAT S.S. DUCT WELDED S.S. DRAIN PAN RH HWS HWR ~ ~ STEAM HUMIDIFIER ~ LPS ~ LPR D LOCATED IN CORRIDOR ~ INDIRECT WASTE TO FLOOR DRAIN NOTES: 1.ALL DUCTWORK IS STAINLESS STEEL # SUPPLY DUCT DETAIL - OPERATING ROOM NTS DESIGNERS NOTES: 1.PROVIDE 2 FULL CROSS SECTIONS THRU EACH OR. DETAIL TITLE / SUPPLY DUCT TAKEOFF DETAIL - OPERATING ROOM SCALE : NONE DATE ISSUED : DECEMBER 2008 CADD DETAIL NO. : SD233100-25.DWG