UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)-

Similar documents
UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)-

UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)-

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

1. Chemical Product and Company Identification

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Vibration tests on a TNAML Luminaire

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

DP86 Constant Voltage with Fitting

ENVIRONMENTAL TEST REPORT

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

/Mar/2014 Rev A

JUL 18 Rev A1

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

Product Tests Report

Mar11 Rev C

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

USB 3.0 Plug & Receptacle

Mar11 Rev B

Test Methods for Consideration Into Radio Standard

environmental chambers for Battery testing

Battery Design Considerations

PERMANENT DOCUMENT. Annex AD to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

environmental chambers for Battery testing

COMITÉ EUROPÉEN DES ASSURANCES

ABB. Modular contactors. Contents

Battery Design Considerations

Residual Current Devices

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

INTERNATIONAL STANDARD

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

M7100 Pressure Transducer

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

DRAFT TANZANIA STANDARD

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

KILOVAC K1K High-Voltage Contactor

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

D5100 Industrial Differential Pressure Transducer

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

APR 17 Rev A

Osram OT 40 OT 60 OT 90 4DIMLT2 E LED Drivers Conformity check to Synergrid C4/10

Vacuum suction nozzle OVEM-...-1P/1N

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Suction Controller SDR

SENTINEL A - Fault Passage Indicator

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

EAE/EAES «HEPHEA 248» Product Technical Instructions

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

INTERNATIONAL STANDARD

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

FIS30XXseries Gas sensor module SPECIFICATIONS

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Table 1. Serie of Digital Room Thermostats.

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Emergency Lighting Control Gear Combo Economy Version (2 in 1)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Part 3 Troubleshooting

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Specification , July 2015

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD

1 Appendix - Product Specifications

Environment Test Report

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Digital Heater Element Burnout Detector K8AC-H

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

D5100 Industrial Differential Pressure Transducer

Technical Data Sheet Opto Interrupter ITR

Event Monitoring Device (EMD)

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

Products for Secondary Battery Market

Installation Instructions for W2H Series Signals

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Qualification Test Report LC Duplex Adapter For LC Cutouts

MICROJET RECORDER (24-CHANNEL 180mm)

EVAPORATIVE AIR COOLER

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

AUR300C. Advanced Ultraviolet Burner Controller

Laser Collimated Beam Sensor

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

INSTRUCTIONS AK-CC 250A

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

Transcription:

문서번호 Prepared Reviewed Approved QAEEF02110122PKASM P/N 42T4946, 42T4956 김홍일안경봉남익현남대호최운기정준용 UN Test Report ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample Image 2011. 01. 22

1. UN Transportation Regulation Test Test Test 1. Altitude Simulation Test 2. Thermal Test Test 3. Vibration Test 4. Shock Test 5. External Short Circuit Test 6. Impact Condition Storing at (low pressure)11.6kpa for 6hr at 20+/5 [5± 2,6hr 40±2,6hr,interval max. 30min] x 10cycle Storing at 20± 5 for 24h [Hz 200Hz Hz, in 15min] x 12 times x 3 direction 1) sinusoidal waveform with a logarithmic sweep 2) Hz 18Hz (maintaining 1gn) app. 50Hz (until 8gn) 200Hz (maintaining 8gn), 1.6mm total excursion Half sine shock (peak acceleration : 150gn, pulse duration : 6msec) x 6 (± x, y, z) direction x 3 cycle 100mΩ ext. shortcircuit at 55± 2 1hr continue after returning at 55± 2 Φ=15.8mm bar, 9.1kg mass, 61± 2.5cm height s Measuring mass before/ after each test (If M>5g, less than 0.1%) Measuring voltage before/ after each test (more than 90%) No leakage, no venting, no disassembly, no rupture, no fire No disassembly, no rupture, no fire (after 6 hours) Temp. monitoring (max. 10 ) Test. Over Current = Manufacturer s recommended max. continuous current X 2 Voltage 1.If voltage 18V, V (min.) = 2 x (max. voltage) or V (min.) = 22V. 2.If voltage > 18V, V (min.) = 1.2 x (max. voltage) No disassembly, no fire (after days) Test 8. Forced Only for Cell, not battery. No disassembly, no fire (after days) * Tests through T1T5 shall be conducted in sequence with the same battery. * We declare that the abovementioned test is the result of being checked according to UN Test ( Manual of Test and Criteria ST/SG/AC.10/2/Add.2) QAEEF02110122PKASM P/N 42T4946, 42T4956 [UN] Test Report (DMNote 3cell, C2) 1 / 6

2. Test Procedure Sample Sample Preparation Preparation Forced dis test is required to cell level, not pack battery level. Test 1 Test 1 Altitude Altitude Simulation Simulation Test 2 Test 2 Thermal Test Thermal Test Test 3 Test 3 Vibration Vibration Test 4 Test 4 Shock Shock Test 5 Test 5 Ext. Ext. Short Short Circuit Circuit 4 ea 1 st cycle d 4 ea 1 st cycle d 4 ea 50 th cycle d 4 ea 50 th cycle d 10ea 1 st cycle 50% d 10ea 50 th cycle d For cylindrical cells, 5 test cells are required. Test 6 Test 6 Impact Impact Test Test Over Over 4 ea 1 st cycle d 4 ea 50 th cycle d Test 8 Forced * 10ea 1 st cycle d 10ea 50 th cycle d Report Report QAEEF02110122PKASM P/N 42T4946, 42T4956 [UN] Test Report (DMNote 3cell, C2) 2 / 6

31. T1T4 Test Before Altitude (T1) Thermal (T2) Vibration (T3) Shock (T4) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) A. 1st cycle fully state 1 12.001 11.993 11.986 11.980 11.93 2 12.049 12.042 12.034 12.02 12.019 3 12.049 184.51 12.043 12.03 12.032 99.96 12.026 4 12.041 12.033 12.025 12.018 12.011 12.035 12.028 12.021 12.014 12.00 5 10.134 185.30 6 8 10.13 10.110 10.09 184.52 186.08 184.30 184.51 186.08 184.30 184.51 184.29 184.29 184.29 10.120 185.05 185.05 185.04 185.04 185.03 B. 50th cycle fully state 9 12.081 12.06 99.96 12.069 12.061 186.53 12.053 186.53 10 12.065 12.058 12.050 12.041 12.033 185.26 11 12.012 12.006 11.99 11.990 11.983 184.48 12 12.098 12.090 12.084 12.08 186.05 12.02 186.05 12.064 12.058 12.050 12.043 185.58 12.035 185.58 13 10.084 185.26 185.26 185.25 185.25 14 15 16 10.118 10.089 10.086 184.26 184.25 186.05 184.25 184.48 186.04 184.24 184.48 186.04 184.24 10.094 185.02 185.01 185.01 185.00 185.00 Measuring mass before/after each test (If M>5g, less than 0.1%) Measuring voltage before/after each test (more than 90%, only d samples) No leakage, no venting, no disassembly, no rupture, no fire QAEEF02110122PKASM P/N 42T4946, 42T4956 [UN] Test Report (DMNote 3cell, C2) 3 / 6

32. T5/T Test A. 1st cycle fully state 1 2 3 4 5 6 8 EXT.Short Circuit (T5) 11.93 12.019 12.026 12.011 12.026 9.99 9.4 9.49 9.86 9.86 55.96 55.90 55.29 55.4 55.96 54.88 55.22 55.95 54.11 55.95 B. 50th cycle fully state 9 10 11 12 13 14 15 16 EXT.Short Circuit (T5) 12.053 12.033 11.983 12.02 12.02 9.981 9.861 9.812 9.96 55.9 56.08 55.29 54.98 56.08 54.2 55.30 55.09 55.23 55.30 100mΩ ext. shortcircuit at 55±2 Test Condition Temperature < 10 No disassembly, no rupture, no fire within 6 hours A. 1st cycle fully state 1 18 19 20 Over (T) 11.94 11.45 11.40 11.333 11.94 25.16 25.29 25.0 24.98 25.29 B. 50th cycle fully state 21 22 23 24 Over (T) 11.39 11.860 11.408 11.394 11.860 25.30 25.23 24.88 25.22 25.30 Max. Current : 2000 ma CC/CV 2Imax(4000mA) 22V cutoff 24Hr Test Condition No disassembly, no fire within day QAEEF02110122PKASM P/N 42T4946, 42T4956 [UN] Test Report (DMNote 3cell, C2) 4 / 6

33. T6 Test (ICR18650C2) Impact (T6) A. 1st cycle 50% state 21 3.80 25.43 22 3.80 108.50 23 3.806 24.36 24 3.806 24.9 25 3.806 114.39 3.80 114.39 B. 50th cycle fully dis state 26 3.351 24.83 2 3.362 46.43 28 3.38 49.26 29 3.369 49.90 30 3.353 4.55 3.38 49.90 Test Condition Φ=15.8mm bar, 9.1kg mass, 61±2.5cm height Temperature < 10 No disassembly, no rupture, no fire within 6 hours QAEEF02110122PKASM P/N 42T4946, 42T4956 [UN] Test Report (DMNote 3cell, C2) 5 / 6

4. Sample Image QAEEF02110122PKASM P/N 42T4946, 42T4956 [UN] Test Report (DMNote 3cell, C2) 6 / 6