INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Similar documents
Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

INSTALLATION AND MANINTENANCE INSTRUCTIONS

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

Rif Cod i220-0

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

GALATEA DOMUS. Dal 1901 COD

AUTOMATIC ICE-CUBE MAKER

Light oil burners. One stage operation

MODULAR AUTOMATIC GRANULAR ICE FLAKER

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Heat Exchanger Block Replacement Instructions

AUTOMATIC MODULAR ICE-CUBE MAKER

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

HEAT ONLY & COMBI BOILER

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

AGA 13 AMP RETRO-FIT WITH AIMS

Installation, operating and servicing instructions

MITICA. Dal 1901 COD

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

13-1. Temperature Regulator

Grinding mill MISTRAL 50L (art. 650P)

Light oil - kerosene burner

GV Series 4 Section Assembly

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

Heating Equipment. gas boilers RX GB. installation and servicing instructions

Contents. 1. Instructions for safety and use 20

Light oil / kerosene burner

Installation and maintenance instructions

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

Mod. ANBR9..G. CR DOC. NO. GAS-HEATED TILTING BRATT PAN. INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE...

Prextherm Rsw High efficiency steel pressurised boilers

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

AUTOMATIC GRANULAR ICE FLAKER

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

INSTALLER INSTRUCTIONS

51AKB / 51 AKC OWNER S MANUAL

HORIZONTAL COOKING SERIES: 700 / 900 S.A.V MAINTENANCE & AFTER SALES WORK PPS-3WE711911CH

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

NXR3. 70 / 290 kw HIGH-EFFICIENCY, PRESSURIZED, CAST IRON, OIL OR GAS BOILERS. 1. Standards - Regulations. 3. Assembly and installation

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

AD-236 Parts Manual. 24 VAC Phase 5

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Installation and maintenance instructions

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Single stage operation oil burner

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

FM1500 SERVICE PARTS

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

MATRIX 2 - COD REV.02

Forced draught gas burner

Hakki Pilke Raven spare parts manual

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

INSTALLATION INSTRUCTIONS

Wall hung combination boiler PROTHERM 23 BTVE

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

Type 300 Series Bench Electrode Stabilization Ovens

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

TC 222 TIRE CHANGER SPARE PART LIST 01

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

BMW E36 Thermostat Removal And Coolant Flush

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

Parts and Service Manual

STREBEL S-CB + Cascade Kits

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

Alpha CD13R,18R and 24R

CR A-F-A-E-HQQE 3x400/ HZ

TECHNICAL INFORMATION INSTALLATION and SERVICE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MATRIX 2 - COD REV.00

INSTRUCTIONS AND ADVICE FOR THE USE, INSTALLATION AND MAINTENANCE OF BUILT-IN ELECTRIC HOBS

CABINET PARTS For Models: ET18GKXBW00, ET18GKXBN00 (White) (Almond)

AUTOMATIC MODULAR ICE FLAKER

TECHNICAL MANUAL CODEX. THREE PASS CONDENSING BOILER WITH LOW NOx

Table Top Patio Heater

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

TECHNICAL MANUAL ASGX

MANUAL FOR ASSEMBLY OF BOILER VIADRUS G 300

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Installation Instructions Part No , Part No Part No

SIMPLICITY MODEL LVPB7200

Manual / Handbuch Spare parts list / Ersatzteilliste

ZEST HOOD. Instructions Manual.

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

INDEX 1. Technical information... page 3 2. Dimensional and technical characteristics... page 3 3. Packing and dispatch...... page 5. Boiler assembly... page 6 5. Shell assembly...... page 11 6. Installation... page 19 7. Inspections and adjustments... page 20 8. Maintenance... page 21 9. Boiler parts... page 22 2

Technical information 1.01 Introduction is a new high efficiency heat generator producing hot water for heating purposes. It can operate with either a liquid and/or gas fuel fired burner 1 or 2 stage. The boiler unit consists of cast iron parts assembled by steel rods and links, the shape of which has been particularly designed to achieve optimum fin distribution. This ensures high thermal efficiency and consequently high energy savings. The boiler is insulated by a thick layer of glass wool to reduce heat loss to the minimum. Key 1 Thermometer 2 Arrangement for automatic control 3 Mains switch Overheat cut-off thermostat 5 C.H. boiler thermostat 1.02 Function of the adjusting and safety devices Fig. 1 Manually reset safety thermostat 3 (fig. 1) This is activated when the temperature in the boiler during the heating phase reaches a value beyond which a dangerous condition could be created. Boiler regulating thermostat 5 (fig. 1) Used to adjust the temperature in the boiler by means of its adjuster knob. This thermostat controls the 1 or 2 stage burner. In the case of use of 1 stage burner, you must not connect the B2 block (2 stage burner). Ambient thermostat This is not standard supply, but can be mounted at the Installer s charge. It is connected in series with the regulating thermostat and contemporaneously controls both the burner and the plant circulator during the heating phase. It is advisable to install this thermostat for greater comfort and energy savings. 2. Dimensional and technical characteristics 2.01 Load loss characteristics (fig. 2) The load losses of the hydraulic circuit pertaining to each boiler model, are specified in the following diagram which refers to the water flow rates corresponding to temperatures between 10 and 20 C. p (mbar) Fig. 2 Q (m 3 /h) 3

0 60 120 C 30 60 0 90 2.02 Dimensional and technical brief (fig. 3 - table 1) A 600 a1 1086 Ø 8 867 B 726 375 a2 a3 Key a1 - PLANT DELIVERY ND 80-3" a2 - PLANT RETURN ND 80-3" a3-3/" BOILER DRAIN Table 1 Fig. 3 Model Heat and D.H.W. (gross) gas Max. Heat and D.H.W. (net) gas+oil Max. Heat and D.H.W. output Heat and D.H.W. (gross) gas Min. Heat and D.H.W. (net) gas+oil Min. Potenza termica Min. N element Water capacity dm 3 Combustion chamber lenght mm Combustion chamber dimension Ømm 05 06 07 08 09 10 11 12 13 1 128,8 153,3 177,7 202,2 226,6 251,1 275,5 300 32, 38,8 116 138 160 182 20 226 28 270 292 31 105 125 15 165 185 205 225 25 265 285 88,8 100 122,2 138,8 155,5 172,2 188,8 205,5 222,2 238,8 80 95 110 125 10 155 170 185 200 215 73 87 101 115 129 13 157 171 185 199 5 6 7 8 9 10 11 12 13 1 9 57 65 73 81 89 97 105 113 121 505 615 725 835 95 1055 1165 1275 1385 195 00 00 00 00 00 00 00 00 00 00 Model Working pressure bar A B Ø Combustion chamber load loss p mbar Combustion chamber volume dm 3 t 10 Water load losses t20 Weight of unit kg. 05 06 07 08 09 10 11 12 13 1 670 780 890 1000 1110 1220 1330 10 1550 1660 130 130 130 150 150 150 150 150 150 150 180 180 180 200 200 200 200 200 200 200 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 63 77 91 10 118 132 16 160 17 187 2,8 3,,8 6,5 8,5 11 13 16 19 23 0,5 0,8 1,8 2,2 2,6 3,2,5 310 361 12 63 51 565 616 670 725 780 NOTE: - The maximum operational temperature of the plant heating water is 90 C.

3. Packing and dispatch (fig. ) Boiler can be supplied in two versions, with the boiler unit either assembled or in parts. Three packs will be dispatched in the first case: 1. Boiler unit 2. Shell 3. Control panel In the second case, there will be the following packs: 2. Shell 3. Control panel. Kit of parts forming the boiler unit 5. Kit of accessories with which to mount the elements. 1. Boiler unit 2. Shell 3. Control panel. Elements 5. Accessory kit Fig. 5

. Boiler assembly Boiler unit Fig. 5 Fig. 7.03 (Fig. 7) Using the tin in the assembly kit, spread a thin layer of minium on the link and its housing, using a soft brush..01 (Fig. 5) Use a 12 mm strip of wood to shim the rear element. Now rest it on a second strip, checking that it remains stable throughout the assembly operations. Fig. 6 Fig. 8.02 (Fig. 6) Use fine glasspaper to thoroughly clean the housing of the link on the rear element and of all other elements forming the boiler unit. 6.0 (Fig. 8) Mount the link in its housing, tapping lightly with a wooden mallet.

Fig. 9.05 (Fig. 9) Using the tube of silicone in the assembly kit, spread a small amount of this product in the retention seal housing. Fig. 11 Fig. 10.06 (Fig. 10) Near the first intermediate element to the rear element. Fig. 12 7

Fig. 13.07 (Figs 11-12 - 13) Insert rod 1 between the two elements, mount nut 3 on the threaded end, place stop pin 2 on the hole of the rod near the pair of elements then clamp the unit together using a N wrench until the two elements have been perfectly joined together..08 Proceed as described in the previous paragraph until all the elements forming the boiler unit have been mounted. Fig. 15 Mounting the rods with the Belleville washers. NOTE: The Belleville washers must be mounted in an opposed way as shown in the diagram while the nuts must be fixed in order to prevent them from being crushed. For boilers with 12-13 - 1 elements, mount the rods with sleeve part 1, remembering to fully tighten the sleeve thread on both sides. ROD 12 ELEM. LG. TOT. 1290 ROD 12 ELEM. LG. TOT. 1290 Fig. 1.09 (Figs 1-15 - 16) Mount the four rods «1», the Belleville washers «2» as shown in fig. 15 and finally torque nuts «3». ROD 1 ELEM. LG. TOT. 1510 Fig. 16 8

Fig. 17.10 (Fig. 17) Using the relative pump, connect to coupling 1 and pump in water under pressure (8 bar). Wait a few minutes before checking that there are no leaks. Now check that smoke retention between the elements is correct. Industrie FER S.r.l. declines all responsibility for damage to persons or property caused by water or smoke leaks from the boiler due to incorrect assembly or failure to check retention. Fig. 19.11 (Fig. 19) Mount all parts on the front side as shown in the diagram..12 (Fig. 20) Assembly detail of the servicing door and burner hatch. Fig. 18 - Mount the following parts on the rear side of the boiler: - four stud bolts (1) - eight stud bolts (2) with their relative flanges (3) and seals () - Mount the collar (5) with the screws (6) and spread a small amount of silicone (included in the kit) around the retention seal housing on the rear end. Fig. 20 9

Fig. 21.13 (Fig. 21) Cover the boiler unit with the supplied mineral wool insulation..1 (Fig. 22) The boiler unit can also be supplied already assembled. It will be sent straight from the factory on a pallet. Remove bolts 1 fixing the boiler to the pallet and place the boiler itself in its final installation position. Now proceed by mounting the various panels. 1 Fig. 22 10

.15 (Fig. 23) When positioning the boiler unit, check that after burner assembly the front door is able to open without striking against the wall or any other nearby boiler, i.e. leave a space of at least 100 mm as shown in the figure. Fig. 23 5. Shell assembly 5.01 (Fig. 2) Mount rear panel 1 on stud bolts 2 without fixing it. 1 2 Fig. 2 11

5.02 (Fig. 25) Prepare the right and left sides, choosing the number of side panels according to the boiler dimensions (see table)(fig. 25). 1056 1026 30 A 0 L A 5 8 el. 9 12 el. 0 L 0 A 13 1 el. MODEL L A.05.06.07.08.09.10.11.12.13.1 580 690 800 910 1020 1130 120 1350 160 1570 580 690 800 910 580 690 800 910 580 690 Number element 5 6 7 8 9 10 11 12 13 1 Fig. 25 12

5.03 (Fig. 26) Connect the panels together using screws 1, washers 2 and nuts 3, reinforcing their lower part with strips fixed with screws 5. Fig. 26 5.0 (Fig. 27) Slacken nuts 1 on the right-hand side of the boiler. 1 Fig. 27 13

5.05 (Fig. 28) Insert the complete right side between rods 1 and the boiler unit, checking that the machined slots fit into their correct position. Now torque nuts 2. 2 1 Fig. 28 5.06 (Fig. 29) Fix the right-hand side to the rear panel using screws 1. 1 Fig. 29 1

5.07 (Fig. 30) Slacken nuts 1 on the left-hand side of the boiler and mount the left-hand side part, checking that the machined slots fit into their correct position. Now torque nuts 1. Fig. 30 5.08 Now fix the left-hand side to the rear panel using screws 1 in the same way as right side assembly (fig. 29). 5.09 (Fig. 31) Fix front lower panel 2 with the four self-threading screws 1. 1 Fig. 31 2 15

5.10 Overturn the capillary tube of water gauge 6 (fig. 1) and screw its union to the relative sheath on the front part of the boiler unit (fig. 32). Fig. 32 5.11 (Fig. 33) Fix the upper panel 1, according to the dimension of the boiler. Prepare the front lower pannel 2, fixing the grommet 3 for the cable of the burner. Fix angle on the both sides. Fix the safety wiring box 5 on upper angle. 16 Fig. 33

5.12 (Fig. 3) Overturn the capillary tubes and insert the 3 probes 1 into sheath 2 (- adjuster thermostat - safety thermostat - thermometer). 1 2 Fig. 3 5.13 (Fig. 35) Fix angle 1 (right-left), assemble the pannel 2 and the control pannel. Fix safety box 3 by self-threading screw inside the angles 1. Insert the board on the pannel 2 and fix sideways with the screw 5 Cover the board with the safety cap 6. NOTE: The electrical connections between the burner and boiler are at the charge of Qualified Personnel. Fig. 35 17

5.1 (Fig. 36) Overturn the electrical mains cable, allow it to pass under the boiler unit and fix it with the relative screws 2 on to core hitch 3 on the rear wall. 2 1 Fig. 36 5.15 (Fig. 37) Mount upper front panel 1. 1 A Fig. 37 18

6. Installation Boiler installation must only be carried out by Qualified Personnel in compliance with the Manufacturer s instructions and according to all laws and provisions in merit. You are particularly advised to comply with all safety regulations governing the construction and location of smoke stacks. 6.01 Electrical connection Connect the circulator, the burner and the ambient thermostat (if used) according to the indications applied to the relative cables and in compliance with the enclosed wiring diagram (fig. 38). Always install a bipolar circuit-breaker between the mains socket and the appliance. The opening between the contacts of this circuit-breaker should be at least 3 mm and it should be equipped with fuses. Always connect the appliance to a good grounding system. Industrie FERROLI S.p.A. declines all responsibility for damages to persons or property caused by failure to connect the appliance to a good grounding system. TS TR1 22 TR2 12 L 1 TS TR1 22 TR2 12 21 11 9 21 11 IL 230V 50Hz IL CA 8 6 10 11 2ST T8 1 2 3 5 6 7 8 9 10 11 12 7 12 T7 T6 B5 B2 B L N L1 N T1 T2 S3 B CA B5 T6 T7 T8 2ST N 2 5 S3 T2 T1 N B1 230V 50Hz B1 B2 3 L1 Fig. 38 Key IL = Main switch CA = Contact auxiliary TR1 = Boiler thermostat 1 stage TR2 = Boiler thermostat 2 stage TS = Safety thermostat B1 = Burner 1 stage B2 = Burner 2 stage 2ST = Contact 2 stage Remove the line if room thermostat is fitted 19

6.02 Connection to the water main Connect the appliance to the water main in compliance with the indications given near each coupling and according to those shown in figure 2 of this handbook. Connection must ensure that the pipes are free from tensions. It is essential to mount a safety valve on the heating circuit as near as possible to the boiler without any obstructions or on-off device between this and the valve itself. The appliance is not supplied with expansion tank. Connection to this device must therefore be carried out by the Installer. 6.03 Connection to the smoke stack Always connect the boiler to a good smoke stack built in compliance with the current provisions in merit. The duct between the boiler and the smoke stack must be made of a suitable material, i.e. able to withstand the temperatures and rust resistant. Always check that all joints are well sealed and thermally insulate the entire duct between the boiler and stack in order to prevent condensation from forming. 7. Inspections and adjustments 7.01 Before initial ignition Before switching on for the first time, it is advisable to check that: a) the system has been filled at the correct pressure and is well vented; b) there are no water or fuel leaks; c) the electric power supply is correct; d) the entire smoke duct has been correctly made and that it hasnot been installed too near orthroughinflammable parts; e) that there are no inflammable substances near the appliance; f) that the burner is proportional to the boiler rating; g) that the water on-off valves are open. 7.02 Initial ignition Having carried out the preliminary inspections, proceed with the following ignition manoeuvres: 1. Open the fuel on-off valve. 2. Adjust thermostat 5 (fig. 1) to the required value. 3. Close the switch upstream of the boiler and switch (fig. 1) on the control panel. The burner will start and the boiler begin to operate. 7.03 After initial ignition After having switched on the boiler for the first time, it is advisable to check that: a) the burner operates correctly. This inspection should be made with the relative instruments; b) the thermostats operate correctly; c) water circulates around the system; d) the fumes are completely disposed of through the stack. 7.0 Switching off the boiler For short periods at a standstill, just use switch (fig. 1) on the control panel. If the boiler is to remain inoperative for a long period, besides operating switch, it is also essential to shut the fuel onoff valve. When the boiler remains for long periods at a standstill during the winter period, prevent damage from freezing by pouring antifreeze fluid into the system or by completely emptying the boiler. The boiler should only be serviced by Qualified Personnel. It is advisable to have the appliance checked at least once a year, before the winter season. Besides the state of cleanliness of the boiler, this inspection should also include correct operation of all boiler control and safety devices plus the burner. 20

8. Maintenance 8.01 Cleaning the boiler Switch off the boiler. 8.02 (Fig. 39) open door 2 by unscrewing the relative knobs 1. 8.03 Remove panels 3 and (fig. 39) Now clean inside the boiler. Check the entire smoke duct and clean it if necessary. Consult the Manufacturer's instructions when cleaning the burner. Cleaning brush 2 1 3 1 Cleaning brush Fig. 39 21

9. Boiler parts 9.01 Boiler unit Key 1 3300770 FRONT ELEMENT 2 3300780 REAR ELEMENT 3 3300790 INTERMEDIATE ELEMENT 3300800 INTERMEDIATE ELEMENT PLUS FEET 5 3310070 SMOKEBOX COLLAR 6 3320211 UPPER SERVICING DOOR 7 33202150 TELLTALE 8a 33202170 BOILER BURNER DOOR 8b 33202190 BOILER BURNER DOOR 9 3300811 SHEATH 1"1/x235 (5 BULBS) 10 3000610 HEX PLUG 11 33601320 11/ FE00 HEX PLUG 12 383650 FLANGE O. 160x160 THICKNESS 16 13 3008930 PLUG M16 FOR DOOR HINGES 1 300890 PLUG 12x50 UNI 1713 15 3008950 BUSHING M16xM20 FOR SIDES 16 3008960 NUT M20 H7 FOR SIDE FIXING 17 3010230 PLUG M16x115 FOR HANDLE 18 3205080 LINK ID 9. ED 100.22 LENGTH 5 19 3300220 CLENCHING SPRING ISO WIRE D. 0.8 20 30370 ROD M12x500 20 30380 ROD M12x610 20 30390 ROD M12x720 20 303500 ROD M12x830 20 303510 ROD M12x90 20 303520 ROD M12x1050 20 303530 ROD M12x1180 20 30350 ROD M12x1290 20 303550 ROD M12x100 20 303560 ROD M12x1510 21 3531650 BURNER DOOR INSULATION D. 392x5 22 3531661 SERVICE DOOR INSULATION 23 3690110 1/2" NPT CHECK VALVE FOR WATER GAUGE 2 37511630 COMPLETE DOOR HANDLE 25 3010670 HANDLE M16 26a 38008670 COMPLETE BURNER DOOR 26b 38008680 COMPLETE BURNER DOOR 27 35100180 RUBBER SEAL ED 133 ID 90 THICKNESS 22

9-02 Shell Key 0 37025850 COMPLETE MODULAR SIDE PANEL 1a 37029020 COMPLETE RIGHT FRONT SIDE PANEL N 1 1b 37029030 COMPLETE RIGHT FRONT SIDE PANEL N 2 1c 3702900 COMPLETE RIGHT FRONT SIDE PANEL N 3 1d 37029050 COMPLETE RIGHT FRONT SIDE PANEL N 2a 37028980 COMPLETE LEFT FRONT SIDE PANEL N 1 2b 37028990 COMPLETE LEFT FRONT SIDE PANEL N 2 2c 37029000 COMPLETE LEFT FRONT SIDE PANEL N 3 2d 37029010 COMPLETE LEFT FRONT SIDE PANEL N 3a 37029060 COMPLETE MODULAR COVER N 1 3b 37029070 COMPLETE MODULAR COVER N 2 3c 37029080 COMPLETE MODULAR COVER N 3 3d 37029090 COMPLETE MODULAR COVER N 37025980 COMPLETE MODULAR COVER N 5 5 38509150 CONTROL PANEL WITH INSTRUMENTS 6 3500520 BOILER INSTRUMENT PANEL 7 37025820 COMPLETE REAR WALL 8 37025830 COMPLETE UPPER FRONT PANEL 9 3702580 COMPLETE LOWER FRONT PANEL 50 36503630 DUAL CORE HITCH FERROLI TYPE 51 31000210 MO/A3 PRONG COUPLING CLIP 52 3120770 SIDE FIXING BRACKET 53 3500220 DISK WITH GROUND SYMBOL 5 300060 FE00 COUPLING PRONG 56 35003390 JIG FOR GEARCASE 58 360150 SAFETY KEY LS 51572 C. 1500 110 C 59 3601880 C.H. BOILER THERMOSTAT 61 3600790 THEMOMANOMETER 62 36500200 RUBBER CORE HITCH ART. 302 QVA 63 36501900 TERMINAL STRIP OK 32/12-500K/12 6 36502651 TERMINAL 1-12 IND.PLATE 65 36100290 MAIN SWITCH 68 31135920 SPACER 69 32911030 SAFETY WIRING BOX 70 3291100 SAFETY WIRING CAP 23

cod. 350732/0 01/98 ALL SPECIFICATIONS SUBJECT TO CHANGE Stockton Close, Minworth Industrial Park, Minworth, Sutton Coldfield, West Midlands B76 IDH Sales: 021/3132030 Service: 021/3131030 Fax: 021/3132319