Detailed operating instructions

Similar documents
Detailed operating instructions

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

OPERATING INSTRUCTIONS

Operating instructions

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

, ,

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

SCS motion sensors Surface/wall mounting - PIR

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

Integrated PIR detectors

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

compact office 24V compact office 24V Lux

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

compact office 24V compact office 24V Lux

Automatic switch attachment Standard Installation Instructions

1. Basic safety information 3 2. Proper use 3

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

KNX/EIB - Product database - Application description

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Remote alarm unit Art. Nr.:

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

LPCMPIRM65 & LPCMPIRDSI65

Detector switch - Dual Tech SCS

Ceiling PIR HS presence detector. Product Guide. Overview. Features

System 2000 Automatic control switch 2 Standard. 1 Safety instructions. 2 Device components. 3 Function. Order-No. : Operating instructions

Product and Applications Description

2. Safety. 4. Function

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

LUXOMAT PD4/M PD4/S. SM Surface mount. FC Ceiling mount. FM Flush mount

User Manual 120/240/300 Outdoor Motion Detector

FLAT IS ESY, BECAUSE IT REPRESENTS MAXIMUM PERFORMANCE WITH SLIM DESIGN

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Presence detector Komfort attachment Installation Instructions

Unpack, connect, done - no further work required

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Apollo Intelligent Auto Aligning Beam Detector. User Guide

EBMHS (standard & slim-line PSU)

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

IP65 High Bay Dual Sense Sensor

1. Basic safety information 3 2. Proper use 3

LPC3BSP65 & LPC3BDP65

360º Surface Mount Ceiling PIR Light Controller

1126 Series Ceiling Mount PIR Motion Detector

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

IMR IX176 Portable Gas Detector User Manual

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

FR-A180 FR-A360. Occupancy detector. Use

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

EBDSPIR-PRM-LV Product Guide

LUXOMAT Application examples for electricians and planners

UP 258E11 OPTISENS OFFICE

LUX Hardwired - Installation Notes

11,1 30. Ordering data

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Detector switch - Dual Tech

60W Multi PIR Bulkhead

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

18W Round LED Wall/Ceiling Light with Microwave Sensor

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

IP65 High Bay Dual Sense Sensor

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Analogue Dimming Microwave Presence/Absence Detector

Alarm System SECURE AS 302

System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard

Direct Dim Microwave Presence/Absence Detector

Installation Instructions

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Data sheet. Function description. Benefits

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Compact Movement Activated Sensor Installation Instructions

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Transcription:

MA00744002 Detailed operating instructions MD-FLAT 360i/8 RW EP10427886 MD-FLAT 360i/8 SW EP10427893 MD-FLAT 360i/8 RB EP10428074 MD-FLAT 360i/8 SB EP10428081 MD-FLAT-E 360i/8 RW GST EP10427862 MD-FLAT-E 360i/8 RW EP10428548 MD-FLAT-L 360i/8 RW EP10428609 ESYLUX GmbH An der Strusbek 40 22926 Ahrensburg Germany info@esylux.com www.esylux.com 1

Table of contents 1 Description 3 2 Safety instructions 3 3 Operation / functionality 4 3.1 Conditions in which the lighting is switched on 4 3.2 Conditions in which the lighting is switched off 4 3.3 Switching delay not in pulse mode 4 4 Installation / connection 5 4.1 Masking the field of detection 7 5 Activation 7 5.1 Overview of factory settings 7 6 Settings 8 6.1 Control via external S button 8 6.2 Configuring parameters via remote control 8 6.3 Mobil-PDi/MDi 8 6.4 Mobil-PDi/MDi temporary settings 9 6.5 Programming the Mobil-PDi/MDi 10 6.6 Mobil-PDi/MDi-universal 12 6.7 Mobil-PDi/MDi-universal temporary settings 12 6.8 Programming the Mobil-PDi/MDi-universal 13 7 Technical data 16 8 Troubleshooting 16 8.1 Maintenance 17 8.2 Cleaning 17 9 ESYLUX Manufacturer s guarantee 18 2 / 18

1 Description The ESYLUX ceiling-mounted motion detector is a passive infrared presence detector that responds to moving heat sources, such as people walking. The motion detector is designed for areas with low levels of natural light, such as hallways, cellars, staircases, changing rooms, toilets, garages etc. Parameters can be configured using the ESYLUX Mobil-PDi/MDi and Mobil-PDi/MDiuniversal remote controls as well as via the manual setting elements. Note: Use this product only as intended (as described in the user instructions). The device must not be changed, modified or painted doing so will void any warranty claims. You must check the device for damage immediately after unpacking it. If there is any damage, you should not install the device under any circumstances. If you suspect that safe operation of the device cannot be guaranteed, you should turn the device off immediately and make sure that it cannot be operated unintentionally. 2 Safety instructions Work on the 230-V power system must be carried out by authorised personnel only, with due regard to the applicable installation regulations/standards Switch off the power supply before installing the system On the input side, the device is to be protected against short circuits with a 10-A circuit breaker Protection type IP 20 for interior use 3 / 18

3 Operation / functionality 360 field of detection, 8-m range at an installation height of 2.5 m Automatically controls light channels depending on presence and daylight With zero-cross switching The setting options can vary depending on the remote control used; please see Configuring parameters via remote control 3.1 Conditions in which the lighting is switched on The lighting is switched on if the target brightness value is below the preset lux value and movement is detected in the field of detection. Further movement is acknowledged by the sensor with two short flashes of the red LED (the LED can be switched off; see Configuring parameters via remote control ). 3.2 Conditions in which the lighting is switched off The lighting is switched off if no movement is detected in the field of detection and the preset switch-off delay time has elapsed. 3.3 Switching delay not in pulse mode When persons are present, in order to avoid sudden changes in brightness caused by undesired switching on/off of the lighting, the detector will only be triggered after a time delay. Example: a passing cloud could potentially cause unnecessary switching. Time delay from light to dark: 30 sec. = red LED lights up during this period. Time delay from dark to light: 5 min. = red LED flashes during this period. 4 / 18

4 Installation / connection Note: Switch off the power supply before installing the system. The detectors can be flush mounted and are also suitable for recessed ceiling mounting using accessories Recessed mounting Recessed ceiling mounting (see accessories) for suspended ceilings 5 / 18

Specifications regarding the range of the detector relate to an ambient temperature of approx. 20 C Movement crossways to the detector is optimal for triggering the detector; head-on approaches to the detector are more difficult to detect and therefore the range of the detector is significantly reduced 6 m 8 m The detector should be positioned depending on the available space and usage requirements Make sure that the detector has a clear line of sight, as infrared beams cannot penetrate solid objects Connect the detector in accordance with the circuit diagram Single connection Parallel connection L Phase, 230 V Lighting Neutral conductor Push button 6 / 18

4.1 Masking the field of detection Use the lens mask provided to mask out specific areas of detection. 5 Activation Connect the power supply. A warm-up phase of 25 seconds is initiated. The red LED and the blue LED flash alternately. During this time, the lighting is switched on. 5.1 Overview of factory settings Factory settings Light value approx. 100 lux Switch-off delay time 5 min. Sensitivity 100% Remote control active 7 / 18

6 Settings 6.1 Control via external S button The ceiling-mounted motion detector is equipped with a connection for an external button (S terminal). This can be used to switch the lighting on and off manually. Modes activated by pressing the external button: Press button for approx. 1 second: The lighting is switched on or off (for the duration of the switch-off delay time) Further parameters can be configured via remote control. These can be purchased as accessories. 6.2 Configuring parameters via remote control Note: For optimum reception, when programming the settings, point the remote control at the detector. Please note that if the sensor is exposed to direct sunlight, the standard detection range of approx. 8 m may be dramatically reduced due to the sun's infrared rays. 6.3 Mobil-PDi/MDi (EM10425509) 8 / 18

6.4 Mobil-PDi/MDi temporary settings Parameter configurations are only temporarily applied. Function Customised setting ON / OFF Switching the lighting ON/OFF manually. Note: The ON / OFF mode can be cancelled by pressing the button. ON acknowledgement: Movement detected in the field of detection is acknowledged with two short flashes of the red LED. OFF acknowledgement: Movement detected in the field of detection is acknowledged with one short flash of the red LED. / settings Temporarily set values are cleared and the detector returns to the manually preset operating mode. 4h ON / OFF The lighting is switched on or off continuously for approx. 4 hours. If no movement is detected in the field of detection and the preset switch-off delay time has elapsed, the detector returns to the previous operating mode. Note: The 4h ON / OFF mode can be cancelled by pressing the button. Test Checking the range/detection using the test mode. Connected lighting turns on for clear inspection/pacing out of a detector s field of detection. Real-time, load-free indication of movement given by two flashes of the blue LED. Note: Exit test mode by pressing the TEST or RESET button again. 9 / 18

6.5 Programming the Mobil-PDi/MDi Alterations to parameters are applied permanently. Function Customised setting Enter programming mode The detector goes into programming mode. Acknowledgement: The blue LED lights up permanently and the lighting is switched on continuously. Exit programming mode The set parameters are stored on the detector. Acknowledgement: The blue LED is switched off. Set the brightness switching value, max. 2000 lux The detector switches the lighting on if the target brightness value is below the preset lux value and movement is detected in the field of detection. Acknowledgement: The red and blue LEDs flash alternately three times. The detector operates in daytime mode Light measurement is no longer active. Acknowledgement: The red and blue LEDs flash alternately three times. Take a reading of the current ambient light value The current ambient lighting level (between 5-2000 lux) is entered as the switch-on value. The connected lighting and the blue LED switch OFF. Once the input process has been successfully completed, the lighting switches ON and the blue LED lights up continuously. Fully automatic/semi-automatic mode The lighting can be controlled in fully automatic and semi-automatic modes. Fully automatic: The lighting is switched on depending on the set lux value and movement being detected. If movement is no longer detected, the preset switch-off delay time will start. The relevant active status can be optionally overridden using the external S button. Acknowledgement: The blue LED flashes three times. Semi-automatic: Control (activation of the lighting) via the external S button. The lighting remains switched on as long as movement is detected and the target brightness value is greater than the preset lux value. Acknowledgement: The blue LED is switched off for approx. 3 seconds. 10 / 18

Function Customised setting Short pulse As soon as movement has been detected in the field of detection, the detector switches the lighting on for approx. 5 second and off for approx. 5 seconds. This function can be used to control automatic stairwell lights, for example. Acknowledgement: The red and blue LEDs flash alternately three times. 30 min Switch-off delay time The switch-off delay time starts once movement is no longer detected in the field of detection. Acknowledgement: The red LED flashes three times. PIR sensitivity Settings: maximum (100%), 75%, 50%, minimum (25%) The sensitivity of the detector for the purpose of detecting movement can be set. Acknowledgement: The red and blue LEDs flash three times. Detector LEDs ON / OFF The LEDs in the detector can be switched on or off. Acknowledgement: LEDs OFF: The blue LED is switched off for approx. 2 seconds. LEDs ON: The blue LED flashes three times. 3 x 1 x Light level switching Pressing the Programming button three times and then pressing the Eye button once allows the light level measurement to be switched between ceiling mounting level and wall mounting level. Feedback from ceiling mounting level: The red LED in the detector lights up (factory setting). Feedback from wall mounting level: The green LED in the detector lights up. 11 / 18

6.6 Mobil-PDi/MDi-universal (EP10433993) 6.7 Mobil-PDi/MDi-universal temporary settings Parameter configurations are only temporarily applied. Function Customised setting PDi/MDi Remote control Functions Channel 2 System Selecting remote control: PDi/MDi Remote control Functions Channel 2 System To configure temporary settings, select the sub-item Functions in the PDi/MDi menu. Functions ON/OFF Test 4 h ON/OFF ON / OFF Manual switching on/off of lighting. Note: The 4h ON / OFF mode cannot be interrupted using the ON / OFF function; it can only be interrupted using the function. ON acknowledgement: Movement detected in the field of detection is acknowledged with one short flash of the red LED. OFF acknowledgement: Movement detected in the field of detection is not acknowledged. 12 / 18

Function Customised setting Functions ON/OFF Test 4 h ON/OFF / settings Temporarily set values are cleared. The detector returns to the preset operating mode. Functions ON/OFF Test 4 h ON/OFF 4h ON / OFF The lighting is switched on or off continuously for approx. 4 hours. If no movement is detected in the field of detection and the preset switch-off delay time has elapsed, the detector returns to the previous operating mode. Note: The 4h ON / OFF mode can be temporarily exited using the function. 6.8 Programming the Mobil-PDi/MDi-universal Programmed values are applied permanently. 1. Select the sub-item in the PDi/MDi menu. PDi/MDi Remote control Functions Channel 2 System 2. Then press the button to enter programming mode. Acknowledgement: The red LED lights up permanently and the lighting is switched on continuously. 3. Press the button to exit programming mode. Acknowledgement: The red LED is switched off. 13 / 18

Function Customised setting Read-in Light Time LEDs ON/OFF Fully/semi-automatic Take a reading of the current ambient light value The detector switches the lighting on if the target brightness value is below the preset lux value and movement is detected in the field of detection. Acknowledgement: The blue LED and the lighting are switched off for approx. 5 seconds while the reading is taken. Read-in Light Time LEDs ON/OFF Fully/semi-automatic Set the brightness switching value Setting values: 10, 100, 250, 400, 600, 800, 2000 lux The detector switches the lighting on if the target brightness value is below the preset lux value and movement is detected in the field of detection. Acknowledgement: The red LED flashes three times in cycles if the selected brightness switching value has been confirmed using the button. Light 400 lux Read-in Light Time LEDs ON/OFF Fully/semi-automatic Time 5 min Read-in Light Time LEDs ON/OFF Fully/semi-automatic Switch-off delay time Setting values: Short pulse, 1, 2, 5, 10, 15, 30 min. Short pulse As soon as movement has been detected in the field of detection, the detector switches the lighting on for approx. 5 second and off for approx. 5 seconds. This function can be used for operating automatic stairwell lights, for example. Acknowledgement: The red LED is switched on for 5 seconds and off for 5 seconds. Switch-off delay time: 1, 2, 5, 10, 15, 30 min. The switch-off delay time starts once movement is no longer detected in the field of detection. Acknowledgement: The red LED flashes three times in cycles. / factory settings The settings for the remote control are reset to the factory settings. Acknowledgement: The red LED flashes three times. 14 / 18

Function Customised setting Read-in Light Time LEDs ON/OFF Fully/semi-automatic Detector LEDs ON / OFF The LEDs in the detector can be switched on or off by pressing the Acknowledgement: LEDs OFF: The blue LED is switched off for approx. 2 seconds. LEDs ON: The blue LED flashes three times. button. Read-in Light Time LEDs ON/OFF Fully/semi-automatic Read-in Light Time LEDs ON/OFF Fully/semi-automatic Fully automatic / semi-automatic mode The lighting can be controlled in fully automatic and semi-automatic modes by pressing the button. Fully automatic: The lighting is switched on depending on the set lux value and movement being detected. If movement is no longer detected, the preset switch-off delay time will start. This mode can be optionally switched on or off using the external S button. Acknowledgement: The blue LED flashes three times. Semi-automatic: The lighting is controlled using the external S button. The lighting remains switched on as long as movement is detected and the target brightness value is greater than the preset lux value. Acknowledgement: The blue LED is switched off for approx. 2 seconds. Light level switching Pressing the key three times and then pressing the button once allows the light level measurement to be switched between ceiling mounting level and wall mounting level. Feedback from ceiling mounting level: The red LED in the detector lights up (factory setting). Feedback from wall mounting level: The green LED in the detector lights up. 15 / 18

7 Technical data Operating voltage 230 V AC µ = contact opening width 1.2 mm Target brightness value approx. 5-2000 lux Switching capacity 2300 W / 10 A (cos phi = 1) 1150 VA / 5A (cos phi = 0.5) Switch-off delay time Protection type/protection class Operating temperature range Short pulse/approx. 15 sec. 30 min. IP 20/II 0 C to +50 C 8 Troubleshooting Fault Cause Lighting does not switch on. Lighting is switched off during the hours of darkness despite the presence of persons Lighting does not switch off or lighting switches on spontaneously when no persons are present. Button does not work. Lighting switches on and off in warm-up phase. Detector does not respond. - Ambient light level is above the preset target brightness value - Lighting has been switched off manually - There are people in the field of detection - There are sources of thermal interference in the field of detection, such as heating, air-conditioning or moving objects (e.g. curtains by open windows) - The switch-off delay time has been set too short - Ambient light level is above the preset target brightness value - Lighting has been switched off manually - The switch-off delay time has not yet elapsed - There are sources of thermal interference in the field of detection, such as heating, air-conditioning or moving objects (e.g. curtains by open windows) - Device is still in the start-up phase - Illuminated button has been used without a neutral wire connection - Button is not routed to the S terminal - Detector exposed to too much artificial light - Check the power supply 16 / 18

8.1 Maintenance The ceiling-mounted motion detector does not contain any components that require maintenance. The device can only be replaced as a complete unit. Note: This device must not be disposed of as unsorted household waste. Used devices must be disposed of correctly. Contact your local town council for more information. 8.2 Cleaning No corrosive cleaning agents or solvents may be used for cleaning and care of the device. Please use a lint-free cloth that is either dry or dampened only with water. 17 / 18

9 ESYLUX manufacturer's guarantee ESYLUX products are tested in accordance with applicable regulations and manufactured with the utmost care. The guarantor, ESYLUX Deutschland GmbH, Postfach 1840, 22908 Ahrensburg, Germany (for Germany) or the relevant ESYLUX distributor in your country (visit www.esylux.com for a complete overview) provides a guarantee against manufacturing/material defects in ESYLUX devices for a period of three years from the date of manufacture. This guarantee is independent of your legal rights with respect to the seller of the device. The guarantee does not apply to natural wear and tear, changes/interference caused by environmental factors or damage in transit, nor to damage caused as a result of failure to follow the user or maintenance instructions and/or as a result of improper installation. Any illuminants or batteries supplied with the device are not covered by the guarantee. The guarantee can only be honoured if the device is sent back with the invoice/ receipt, unchanged, packed and with sufficient postage to the guarantor, along with a brief description of the fault, as soon as a defect has been identified. If the guarantee claim proves justified, the guarantor will, within a reasonable period, either repair the device or replace it. The guarantee does not cover further claims; in particular, the guarantor will not be liable for damages resulting from the device s defectiveness. If the claim is unfounded (e.g. because the guarantee has expired or the fault is not covered by the guarantee), then the guarantor may attempt to repair the device for you for a fee, keeping costs to a minimum. 18 / 18